HomeMy WebLinkAboutL3.2 Irrigation Details 2020-02-26 _��•"••LENE• /�
RIEC
4
'3M'DBY WATERPROOF '
FINISH GRADE CONNECTORS OR EQUAL
RECTANGULAR VALVE BOX (
3"MIN FINISH GRADE/TOP OF PVC SCH 40 ELL
- 6"POP-UP SPRAY HEAD, MULCH PVC SCH 80 NIPPLE SINGLE OUTLET PRESSURE
PRS30 SPRAY BODY WITH FINISHED GRADE LAMINATED TAG W/ZONE NUMBER PVC SCH 40 COUPLING COMPENSATING EMITTER GNL a
FACTORY-INSTALLED
—_ DRAIN CHECK VALVE \ WATERPROOF CONNECTIONS Z
W/NOZZLE AS SPECIFIED DISTRIBUTION TUBING DESIGNED BY RECTANGULAR VALVE BOX y4 9
REMOTE CONTROL VALVE TOP OF MULCH OR FINISH GRADE 1/q"TUBING STAKE;DO NOT GNL
PENETRATE ROOT NJ
MP ROTATOR NOZZLE �
LATERAL TEE OR ELL PVC SCH 80 NIPPLE(CLOSE) LAMINATED TAG W/ZONE NUMBER DRAWN BY 0
PRS40 SPRAY BODY WITH PVC SCH 40 ELL PVC SCH 80 NIPPLE MULCH BALL co
NPT X.490INCH JJR z BARB ELBOW FACTORY-INSTALLED DRAIN z PVC SCH 80 UNION FOR SERVICING _
EL
CHECK VALVE PVC SCH 80 NIPPLE(LENGTH AS ABBY. CHECKED BY g
REQUIRED) - PVC SCH 40 MALE ADAPTER 12/9/19 O
BLOCK(1 OF 4) WEED BARRIER FABRIC
CO o Qp �OOoO��ooO 3'MI DEPTH OF 3/a"MINUS WASHED DRIP LATERAL PIPE, -III DATE
1/2"MALE INLET X 1/2"BARBED ELBOW PVC SCH 80 NIPPLE(2-INCH ROCK STAPLE EVERY 36"
FUNNY PIPE;12-INCH LENGTH LENGTH,HIDDEN)AND SCH 40 ELL BLOCK(1 OF 4) SELF-PIERCING - 18057
Lu
°$�° - - 0-
12"LENGTH FUNNY PIPE INLINE PRESSURE REGULATOR BARB CONNECTOR ° PROJECT NO.III 18057 L3.DWG p
PVC SCH 40 TEE OR ELL REMOTE CONTROL VALVE
PVC SCH 40 MALE ADAPTER INLINE WYE FILTER NOTES: FILE NO. N
LATERAL TEE OR ELL PVC LATERAL PIPE BALL VALVE 1.EVENLY SPACE MULTIPLE EMITTERS AROUND THE U
MALE NPT X.49�'NCH PVC LATERAL PIPE PERIMETER OF THE ROOTBALL.
PVC MAINLINE PIPE PVC MAINLINE
BARB ELBOW LATERAL PIPE 2.REFER TO THE SCHEDULE FOR EMITTER COUNTS AND FLOW.
3"DEPTH,3/q"WASHED ROCK PVC SCH 40 TEE OR ELL
'* PVC SCH 80 NIPPLE(2-INCH LENGTH HIDDEN)
*'USE OF THE SIDE INLET IS NOT PERMITTED x
"'USE OF THE SIDE INLET IS NOT PERMITTED".. AND PVC SCH 40 ELL B ^<
W wot0
A s�;au
1 6-INCH POP-UP SPRAYHEAD MP ROTATOR HEAD ELECTRIC CONTROL VALVE (��DRIPZQ�NEONTROL DRIP EMITTER PLACEMENT
NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE _NOT TO SCALE z o
E ? �
F <�p?v�P 3
VZmN�
°v
s
MULCH p"
10" (25.4 CM) KEY UP TO 800' MAX. ` ON-SURFACE DRIPLINE T 11
PEN DOOR WIDTH LINE-OF-SIGHT �•/
1. IRRIGATION CONTROL 4
SUBTERRANEAN EMITTER BOX WIRE IN CONDUIT SIZE �` r
AND TYPE PER PLUG IN 5 1 ^
WEED FABRIC OVER FINISH GRADE O LOCAL CODES FINISH GRADE F-I
SCH 40 PVC ELJN� a�®® 2. PLUG IN TRANSFORMER
FINISH GRADE OPERATION INDICATOR
FINISH GRADE BARB X MALE g eDaom RAINBIRD MODEL:OPERIND
FITTING QUICK COUPLING VALVE IN A ROUND OR
DRIP RECTANGULAR VALVE BOX - ®
DISTRIBUTION SCHEDULE 80 PVC THREADED 3 h+-I
TUBING O U
BARB X MALE NIPPLES;LENGTH AS REQUIRED
FITTING �- —III—
SCHEDULE 40PVC III III- 6
FITTINGS,TYPICAL - Z
HUNTER MAINLINE III III I� J
PLD LOC CAP PIPE -III III III _17-7r 7/2"PE TUBING j11 ° - - zQ� _ -- - OTE: KEY NOTE: W
MOUNT CONTROLLER 1. MODEL:WIRELESS SOLAR SYNC SENSOR UP TO 800'FROM RECEIVER 1. USE TOOL TO INSERT BARB TRANSFER FITTING DIRECTLY INTO DRIPLINE O O
00° - 2. SUITABLE POST,POLE,BUILDING OR GUTTER MOUNT.MOUNT IN LOCATION WHERE SENSOR
BRICK(1 OF 2) LED SCREEN AT EYE TUBING.
LEVEL. CAN RECEIVE FULL SUN,IS OPEN TO RAINFALL AND OUT WALL
SPRINKLER SPRAY PATTERN 2. VAN NOZZLE MAY BE SET TO CLOSED,OR IF IT IS DESIRED TO SEE SPRAY U
3-INCH MIN.DEPTH OF 3/4" 3. WIRELESS SOLAR SYNC RECEIVER MOUNTED ON THE WALL NEXT TO THE CONTROLLER FROM THE NOZZLE,SET THE ARC TO 1/4 PATTERN.THE FLOW FROM THE
4. MODEL:SOLAR SYNC MODULE MOUNTED INSIDE OF HUNTER PCC CONTROLLER
WASHED GRAVEL 5. HUNTER PCC CONTROLLER NOZZLE,0.3 GPM,SHOULD BE ACCOUNTED FOR IN THE SYSTEM DESIGN.
NOTE: �C1
1.ALLOW A MINIMUM OF 6-INCHES OF DRIPLINE TUBING IN VALVE BOX IN ORDER TO DIRECT 6. VALVE CONTROL WIRE
lu
FLUSHED WATER OUTSIDE VALVE BOX. 7. POWERSOURCE H-
H
DRIP LINE FLUSH POINT QUICK COUPLING VALVE Q CONTROLLER Q SENSOR DRIP OPERATION W
6 NOT TO SCALE 0"ROUND NOT TO SCALE V NOT TO SCALE NOT TO SCALE 0 INDICATOR NOT TO SCALE a
VALVE BOX
z_
� pr�XJlBd01)1 \ II.JuYd16
3"MIN.
FINISH GRADE
TAPE&BUNDLE ALL WIRING AT 10 FT.INTERVALS. � WqS ED
MAKE
ASEBUILT P ALL LICES LANS.ITIE ALVE BOXES LOOSE 20 FT.LOOPN 'i ® /�� AGGREGATE
WIRING AT ALL CHANGES IN DIRECTION GREATER �
CONDUIT THAT 30 DEGREES.UNTIE ALL LOOPS AFTER DIRECT BURY Al
SECTION MAKING CONNECTIONS. SECTION COMPACTEDINSTALL ALL 121V.W RING IN ��
NDUIT.PLACE ALL
WIRING UNDER PA EME T AND OTHROUGH SLEEVES J TIES 4"PVC,RISER '
MAIN LINE WIT n
IN CONDUIT. LOOP LENGTH AS j���� ��/ F--+
REQUIRED THREADED TEE ON
CONTRACTOR HAS THE OPTION TO TRENCH ��/\j\ BOTTOM
C IT OR PUA MINIMUM COVER OF LL P.E.DRIP LATERAL 110"CAN BEVIDED BURY PL CLOTH,TURN
PLAN DIRECT AN /\����j\
GUARANTEED. DOWN AT ENDS
FINISH GRADE FINIS GRADE
°> \41 \ LATERAL SCH 80 Lu
H V
MAINLINE ' N �� �� o � FITTINGS&SCH 80
-�� BEDDING y, A � � 0� � THREADED NIPPLES W
LATERAL \�� v q'T / H
120V WIRE SECTIONSOQ� (�'v '/��� 1"GATE VALVE W n/
IN CONDUIT LSNAKE ATE RALLPIPE �✓\�\�roO oOg000 ooY/�\\\ F�-I
IN TRENCH � ��j O��O \�/�� DRY WELL W/MIN.1 CY
PLANS W Q�°�'Q��o ������ OF 1-1/2"WASHED
AGGREGATE SHEET
11 TRENCH & BEDDING MAIN LINE DRAIN
NOT TO SCALE NOT TO SCALE T 3•2