HomeMy WebLinkAboutSanitary Sewer Calculations-10-15-2019 00 m Mountain Vista Site Plan 180334 Sewer Calculations Engineering and surveying Inc. 10/10/2019 #of Dwelling Units (DUs) 25 DU #of people per dwelling 2.11 persons/DU** population 53 people peaking factor* 4.30 assumed infiltration rate** 150 gallons/acre/day lot area 2.4346 acres infiltration rate 365 gpd wastewater generation rate* 89 gal/day/person Average Wastewater Flow Rate 4 gpm Average Wastewater Flow Rate 211 gallons per hour Peak Wastewater Flow Rate 14 gpm Peak Wastewater Flow Rate 856 gallons per hour *Calculated Per Harmon Formula **Based on City of Bozeman Design Standards and Specifications Policy Harmon Formula: Peaking Factor=(18 +PO.5)/(4+PD.�) where:P=Population�n thousands ATTHEW •.° HAUSAUER s ; No. 3838,2P ;War