Loading...
HomeMy WebLinkAboutI-1-Cover-061118 OSTERMAN COMMERCIAL CONDOS PLAN INDEX MASTER SITE PLAN SUBMITTAL SHEET DESCRIPTION DATE 1-1 COVER SHEET&NOTES 6-11-18 760 & 770 OSTERMAN DRIVE C-1 LAYOUT&UTILITIES 6-11-18 C-2 GRADING PLAN 6-11-18 B OZEMAN MONTANA C-3 DETAILS 6-11-18 C-4 DETAILS 6-11-18 C-5 STORM INFILTRATOR 6-11-18 E-1 LIGHT PLAN/PHOTOMETRICS 6-11-18 1/7 FRONT&RIGHT ELEVATIONS 4-10-18 2/7 BACK&LEFT ELEVATIONS 4-10-18 3/7 FOUNDATION PLAN 4-10-18 4/7 MAIN FLOOR PLAN 4-10-18 5/7 ELECTRICAL PLAN 4-10-18 6/7 SECOND FLOOR PLAN 4-10-18 7/7 BUILDING SECTION&DETAILS 4-10-18 L-1 LANDSCAPE PLAN 6-11-18 VICINITY MAP L-2 IRRIGATION PLAN 6-11-18 / - LOT 1A-5A,MINOR SUBDIVISION 41-C SECTION 9,TOWNSHIP 2 SOUTH,RANGE 6 EAST r fi_ CITY OF BOZEMAN,GALLATIN COUNTY,MT �- LOT AREA=1.623(70,698 SQ FT) ZONED M-1 OWNER/DEVELOPER: LONGSHOT EQUITY, LLC PARKING REQUIRED D&R WAREHOUSE: 510 WEST HEMLOCK (WAREHOUSE)=6,912 SF`0.85-(1.0 STALLS/1,000SF)=5.9 STALLS 1 BOZEMAN' MT 59718 p a. , --., „ ❑ (SUPPORTING OFFICE)=3,888*0.85*(1 STALU350 SF)=9.4 STALLS TOTAL PARKING REQUIRED=15 STALLS ESTIMATED REQUIRED PARKING FOR FUTURE BUILDING: 18,000 SQUARE FOOT AT AVERAGE OF 1 SPACE PER 500 SF=36 GENESISENGINEERINGINC. SPACES.THIS WILL ALLOW AMIX OF USES SIMILAR TO THE D&R CIVIL ENGINEER P BUILDING.1 SPACE PER 500 SF WAS USED AS A WEIGHTED AVERAGE PREPARER: 204 NORTH 11TH AVE. IS .'AR `- Y OF RETAIL(%3oo),WAREHOUSE(%000),OFFICE(%250)PARKING BOZEMAN MT 59715 NGINEERING,INC • ;� ��' REQUIREMENTS. 406-581-5730 PARKING PROPOSED: " 55 STALLS OFF-STREET 4 STALLS IN D&R WAREHOUSE /�"'�+� TOTAL PARKING PROPOSED=59 STALLS. THE EXCESS STALLS(44) ARE FOR THE FUTURE SOUTH BUILDING THAT WILL GO THROUGH K ADDITIONAL SITE PLAN REVIEW. BUILDING DESIGNER: IMPACT DRAFTING *5 -� NOTES: 1195 STONERIDGE DRIVE, SUITE 3D "'`',► � d ♦ I 1.NO PARKLAND REQUIRED BOZEMAN, MT 59718 2 NO WETLAND AREA INCLUDED IN LOT 1A-5A R-O 406-552-5382 AREA NOTES: TOTAL FLOOR AREA(D&R)= 10,800 SF TOTAL FLOOR AREA(EST.FUTURE)=18,000 SF FOOTPRINT(D&R)=8,640SF LANDSCAPE DESIGNER: DYLAN MCDOWELL FOOTPRINT(EST.FUTURE)=12,450 SF. •. GROUND FLOOR AREA RATIO= CASHMAN NURSERY FOOTPRINT/70,698 SF=(21,090)/70,698=30% PO BOX 10242 TOTAL FLOOR AREA RATIO= FLOOR BOZEMAN MT 59715 AREA/70,698 SF=28,800/70,698=41% EXISTING BUILDING AREA=N/A 406-587-3406 #n PROPOSED PARKING AREA=22,400 SF PROPOSED BUILDING FOOTPRINT=21,090 SF PROPOSED LANDSCAPE AREA=24,500 SF PUBLIC STREET RIGHT OF WAY=N/A VERIFY SCALE REVISIONS DRAWN BY:JRM PROJECT NUMBER THESE RRwrs MAY BE NO. DESCRIPTION DATE BY CHK'D.BY:CMW OSTERMAN COMMERCIAL CONDOS 1086.010 REDUCED ONE INCH GN 1 UPDATED PER DRC COMMENTS 06-11-18 JRM MASTER SITE PLAN SUBMITTAL SHEET NUMBER ORIGINAL DRAWING. J Engineering APPR.BY: BOZEMAN MT Consulting 204 N.11th Ave. Bozeman,MT 59715 DATE:4/10/18 DRAWING NUMBER Design phone:(406)581-3319 MODIFY SCALE ACCORDINGLY NGINEERING' INC Planning Q.A.REVIEW BY: COVER SHEET I-1 H:\1086\010WCAD\SHEETS\MASTER SITEPLAN\COVER.dwg Plotted by christopher wasia on 6/8/2018 7:40 AM 7Ce Be innin o a New Standard a Commitment COPYRIGHT®GENESIS ENGINEERING,INC.2018 DATE: