HomeMy WebLinkAboutA-6-Second Floor Plan-041018O
F
F
I
C
E
8
'
w
a
l
l
s
O
F
F
I
C
E
8
'
w
a
l
l
s
O
F
F
I
C
E
8
'
w
a
l
l
s
O
F
F
I
C
E
8
'
w
a
l
l
s
O
F
F
I
C
E
8
'
w
a
l
l
s
O
F
F
I
C
E
8
'
w
a
l
l
s
M
E
C
H
.
8
'
w
a
l
l
s
A
D
A
B
A
T
H
8
'
w
a
l
l
s
H
A
L
L
8
'
w
a
l
l
s
A
D
A
B
A
T
H
8
'
w
a
l
l
s
R
E
C
E
P
T
I
O
N
8
'
w
a
l
l
s
R
E
C
E
P
T
I
O
N
8
'
w
a
l
l
s
S
e
c
o
n
d
F
l
o
o
r
=
2
1
6
0
S
Q
.
F
T
.
Second Floor System
c
D
a
t
e
:
mobile #:
phone #:
Project No.
D
r
a
w
n
b
y
:
D
a
t
e
:
Scale:
GENERAL CONTRACTOR:
R
e
v
i
s
e
d
b
y
:
D
r
a
f
t
i
n
g
&
D
e
s
i
g
n
,
I
n
c
.
MOUNTAIN HIGH HOMES
DAN BARNES
2285 VIRGINIA CITT ST,
BOZEMAN MT 59715
B18-0202-2D & R Warehouse
700 OSTERMAN DRIVE
BOZEMAN, MONTANA
BRET FORDER & SCOTT LEPROWSE B.406-539-0396
----
406-581-0667
D
.
J
o
h
n
s
t
o
n
2
8
M
a
r
1
8
D
.
J
o
h
n
s
t
o
n
3
1
M
a
r
1
8
T
h
e
s
e
d
r
a
w
i
n
g
s
a
r
e
l
i
c
e
n
s
e
d
f
o
r
O
N
E
U
S
E
O
N
L
Y
.
D
.
J
o
h
n
s
t
o
n
1
3
F
e
b
1
8
D
.
J
o
h
n
s
t
o
n
1
6
M
a
r
1
8
D
.
J
o
h
n
s
t
o
n
1
0
A
p
r
1
8
IMPACT
DRAFTING & DESIGN, inc.
www.impactdrafting.com
2
0
1
8
Brentwood Professional Center
1195 Stoneridge Dr., Suite 3D
Bozeman, MT. 59718
406-522-5382
A
l
l
r
i
g
h
t
s
r
e
s
e
r
v
e
d
.
A
l
l
d
e
s
i
g
n
s
,
d
r
a
w
i
n
g
s
,
i
d
e
a
s
,
a
n
d
w
r
i
t
t
e
n
m
a
t
e
r
i
a
l
c
o
n
t
a
i
n
e
d
o
r
d
e
s
c
r
i
b
e
d
h
e
r
e
i
n
a
r
e
t
h
e
s
o
l
e
p
r
o
p
e
r
t
y
o
f
I
M
P
A
C
T
D
r
a
f
t
i
n
g
&
D
e
s
i
g
n
I
n
c
.
a
n
d
a
s
s
u
c
h
m
a
y
n
o
t
b
e
a
l
t
e
r
e
d
,
d
u
p
l
i
c
a
t
e
d
,
u
s
e
d
o
r
d
i
s
c
l
o
s
e
d
w
i
t
h
o
u
t
w
r
i
t
t
e
n
c
o
n
s
e
n
t
f
r
o
m
I
M
P
A
C
T
D
r
a
f
t
i
n
g
&
D
e
s
i
g
n
I
n
c
.
scale is correct if
printed on D-Size paper
by IMPACT Drafting
Note: IMPACT Drafting & Design Inc. is not responsible for engineering or
construction. Individual contractors are responsible for meeting codes.
I
M
P
A
C
T
6
7
3/16" = 1'
F
l
o
o
r
P
l
a
n
S
e
c
o
n
d
F
l
o
o
r
3/16" = 1'
s
c
a
l
e
:
3
/
1
6
"
=
1
'
F
l
o
o
r
F
r
a
m
i
n
g
N
o
t
e
s
:
-
d
o
u
b
l
e
j
o
i
s
t
s
o
r
b
e
a
m
u
n
d
e
r
p
a
r
a
l
l
e
l
b
e
a
r
i
n
g
w
a
l
l
s
-
l
a
t
e
r
a
l
r
e
s
t
r
a
i
n
t
a
t
a
l
l
i
n
t
e
r
m
e
d
i
a
t
e
s
u
p
p
o
r
t
l
o
c
a
t
i
o
n
s
S
e
c
o
n
d
F
l
o
o
r
E
l
e
c
t
r
i
c
a
l
s
c
a
l
e
:
3
/
1
6
"
=
1
'
= arc fault ci
r
c
u
i
t
i
n
t
e
r
r
u
p
t
e
d
o
u
t
l
e
t
= Smoke det
e
c
t
o
r
= wall mount
e
d
d
o
o
r
b
e
l
l
= garage doo
r
o
p
e
n
e
r
= ceiling mo
u
n
t
e
d
f
a
n
f
i
x
t
u
r
e
w
/
l
i
g
h
t
= duplex outl
e
t
,
1
1
0
v
.
ELECTRIC
A
L
L
E
G
E
N
D
= 220 outlet= switch = ground fau
l
t
i
n
t
e
r
r
u
p
t
i
n
g
o
u
t
l
e
t
(
G
F
C
I
)
= ceiling mo
u
n
t
e
d
l
i
g
h
t
f
i
x
t
u
r
e
= 3-way swit
c
h
= 4-way swit
c
h
= dimmer sw
i
t
c
h
= wall mount
e
d
l
i
g
h
t
f
i
x
t
u
r
e
= waterproof
o
u
t
l
e
t
(
G
F
C
I
)
= switched d
u
p
l
e
x
o
u
t
l
e
t
,
1
1
0
v
.
= in floor du
p
l
e
x
o
u
t
l
e
t
,
1
1
0
v
.
= phone / sa
t
e
l
l
i
t
e
j
a
c
k
(
R
J
1
1
)
= thermostat = flush, wall
m
o
u
n
t
e
d
,
s
t
a
i
r
w
a
s
h
= recessed, c
e
i
l
i
n
g
m
o
u
n
t
e
d
l
i
g
h
t
f
i
x
t
u
r
e
= ceiling mo
u
n
t
e
d
f
a
n
f
i
x
t
u
r
e
= computer
d
a
t
a
p
o
r
t
(
R
J
4
5
)
= exhaust fa
n
w
/
l
i
g
h
t
= troffer ligh
t
f
i
x
t
u
r
e
(
l
e
d
/
f
l
u
o
r
e
s
c
e
n
t
/
e
t
c
.
)
= stereo / so
u
n
d
s
y
s
t
e
m
j
a
c
k
= television c
a
b
l
e
j
a
c
k
= doorbell bu
t
t
o
n
= garage doo
r
s
w
i
t
c
h
= track lighti
n
g
= over / und
e
r
c
a
b
i
n
e
t
l
i
g
h
t
i
n
g
General Electrical N
o
t
e
s
- Smoke detectors t
o
b
e
interconnected- All Smoke Detecto
r
s
o
u
t
s
i
d
e
Sleeping Rooms and
a
t
t
h
e
t
o
p
a
n
d
bottom of stairs mu
s
t
a
l
s
o
b
e
a
combination carbon
m
o
n
o
x
i
d
e
detector (R315)- Electrical outlets i
n
k
i
t
c
h
e
n
,
g
a
r
a
g
e
and laundry to be 4
8
"
a
b
o
v
e
f
l
o
o
r
level- All interior outlets
t
o
b
e
A
F
C
I
&
tamper resistant- All interior recesse
d
l
i
g
h
t
s
t
o
b
e
o
n
dimmer switches- All Exterior Lights
t
o
b
e
d
a
r
k
-
s
k
y
compliant- Electrical plans ma
y
n
e
e
d
t
o
b
e
deviated from by el
e
c
t
r
i
c
i
a
n
t
o
m
e
e
t
building specific nee
d
s
e
i
t
h
e
r
b
y
design or code, how
e
v
e
r
t
h
o
s
e
deviations must be
d
i
s
c
u
s
s
e
d
w
i
t
h
IMPACT Drafting, B
u
i
l
d
e
r
,
o
r
C
l
i
e
n
t
prior to being made
.
N
o
d
e
v
i
a
t
i
o
n
s
may violate electric
a
l
c
o
d
e
s
.
- IRC Section 303.4
-
W
h
e
r
e
t
h
e
a
i
r
infiltration rate of a
d
w
e
l
l
i
n
g
u
n
i
t
i
s
less than 5 air chan
g
e
s
p
e
r
h
o
u
r
when tested with a
b
l
o
w
e
r
d
o
o
r
a
t
a
pressure of 0.2 inch
w
.
c
.
(
5
0
P
a
)
i
n
accordance with Se
c
t
i
o
n
N1102.4.1.2, the d
w
e
l
l
i
n
g
u
n
i
t
s
h
a
l
l
be provide with who
l
e
-
h
o
u
s
e
ventilation in accord
a
n
c
e
w
i
t
h
Section M1507.3- Per NEC 210.11(C
)
3
b
a
t
h
r
o
o
m
circutting shall eithe
r
b
e
:
a
)
a
2
0
amp dedicated circu
i
t
f
o
r
e
a
c
h
bathroom or b) at le
a
s
t
o
n
e
2
0
A
M
P
circuit supplying onl
y
b
a
t
h
r
o
o
m
outlets
R
e
v
i
s
e
d
b
y
:
D
a
t
e
:
A
d
d
i
t
i
o
n
a
l
R
e
v
i
s
i
o
n
s
D
.
J
o
h
n
s
t
o
n
1
1
A
p
r
1
8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-