Loading...
HomeMy WebLinkAboutA-3-Foundation Plan-041018c D a t e : mobile #: phone #: Project No. D r a w n b y : D a t e : Scale: GENERAL CONTRACTOR: R e v i s e d b y : D r a f t i n g & D e s i g n , I n c . MOUNTAIN HIGH HOMES DAN BARNES 2285 VIRGINIA CITT ST, BOZEMAN MT 59715 B18-0202-2D & R Warehouse 700 OSTERMAN DRIVE BOZEMAN, MONTANA BRET FORDER & SCOTT LEPROWSE B.406-539-0396 ---- 406-581-0667 D . J o h n s t o n 2 8 M a r 1 8 D . J o h n s t o n 3 1 M a r 1 8 T h e s e d r a w i n g s a r e l i c e n s e d f o r O N E U S E O N L Y . D . J o h n s t o n 1 3 F e b 1 8 D . J o h n s t o n 1 6 M a r 1 8 D . J o h n s t o n 1 0 A p r 1 8 IMPACT DRAFTING & DESIGN, inc. www.impactdrafting.com 2 0 1 8 Brentwood Professional Center 1195 Stoneridge Dr., Suite 3D Bozeman, MT. 59718 406-522-5382 A l l r i g h t s r e s e r v e d . A l l d e s i g n s , d r a w i n g s , i d e a s , a n d w r i t t e n m a t e r i a l c o n t a i n e d o r d e s c r i b e d h e r e i n a r e t h e s o l e p r o p e r t y o f I M P A C T D r a f t i n g & D e s i g n I n c . a n d a s s u c h m a y n o t b e a l t e r e d , d u p l i c a t e d , u s e d o r d i s c l o s e d w i t h o u t w r i t t e n c o n s e n t f r o m I M P A C T D r a f t i n g & D e s i g n I n c . scale is correct if printed on D-Size paper by IMPACT Drafting Note: IMPACT Drafting & Design Inc. is not responsible for engineering or construction. Individual contractors are responsible for meeting codes. I M P A C T 3 7 3/16" = 1' F o u n d a t i o n F i r s t F l o o r F r a m i n g s c a l e : 3 / 1 6 " = 1 ' S l a b F o u n d a t i o n a l l b e l o w - g r a d e c o n c r e t e m u s t h a v e w a t e r p r o o f c o a t i n g GENERAL NOTES:- All below grade level concrete to be covered withapproved foundation coating.- IMPACT recommends top of concrete to be12"-18" above top of curb, min.FLOOR FRAMING NOTES: - double joists or beam under parallel bearing walls - lateral restraint (blocking) at all intermediate supportlocations (cripple walls) - solid blocking at any cantilever and under braced walllinesCLOTHES DRYER VENTING:(IMC 504.6.7) - max. length shall not exceed 35' from dryer locationto outlet terminal - length reduced by 2'6" for each 45° bend - length reduced by 5' for each 90° bendexception: where make and model clothes dryer isknown and of manufacturer's installation instructionsprovided to code official, manufacturer's spec.s may beused.ANCHOR BOLTS: to go 7" into concrete and locatedwithin 12", but not less than 7 bolt diameters, from theends of each plate, with a max. spacing of 6' O.C. (4'O.C. for buildings over 2 stories); min. 2 bolts per plate,w. 3"x3"x.229" sq. washer (per IRC R403.1.6, 602.11.1) R e v i s e d b y : D a t e : A d d i t i o n a l R e v i s i o n s D . J o h n s t o n 1 1 A p r 1 8 - - - - - - - - - - - - - - - -