HomeMy WebLinkAboutA-3-Foundation Plan-041018c
D
a
t
e
:
mobile #:
phone #:
Project No.
D
r
a
w
n
b
y
:
D
a
t
e
:
Scale:
GENERAL CONTRACTOR:
R
e
v
i
s
e
d
b
y
:
D
r
a
f
t
i
n
g
&
D
e
s
i
g
n
,
I
n
c
.
MOUNTAIN HIGH HOMES
DAN BARNES
2285 VIRGINIA CITT ST,
BOZEMAN MT 59715
B18-0202-2D & R Warehouse
700 OSTERMAN DRIVE
BOZEMAN, MONTANA
BRET FORDER & SCOTT LEPROWSE B.406-539-0396
----
406-581-0667
D
.
J
o
h
n
s
t
o
n
2
8
M
a
r
1
8
D
.
J
o
h
n
s
t
o
n
3
1
M
a
r
1
8
T
h
e
s
e
d
r
a
w
i
n
g
s
a
r
e
l
i
c
e
n
s
e
d
f
o
r
O
N
E
U
S
E
O
N
L
Y
.
D
.
J
o
h
n
s
t
o
n
1
3
F
e
b
1
8
D
.
J
o
h
n
s
t
o
n
1
6
M
a
r
1
8
D
.
J
o
h
n
s
t
o
n
1
0
A
p
r
1
8
IMPACT
DRAFTING & DESIGN, inc.
www.impactdrafting.com
2
0
1
8
Brentwood Professional Center
1195 Stoneridge Dr., Suite 3D
Bozeman, MT. 59718
406-522-5382
A
l
l
r
i
g
h
t
s
r
e
s
e
r
v
e
d
.
A
l
l
d
e
s
i
g
n
s
,
d
r
a
w
i
n
g
s
,
i
d
e
a
s
,
a
n
d
w
r
i
t
t
e
n
m
a
t
e
r
i
a
l
c
o
n
t
a
i
n
e
d
o
r
d
e
s
c
r
i
b
e
d
h
e
r
e
i
n
a
r
e
t
h
e
s
o
l
e
p
r
o
p
e
r
t
y
o
f
I
M
P
A
C
T
D
r
a
f
t
i
n
g
&
D
e
s
i
g
n
I
n
c
.
a
n
d
a
s
s
u
c
h
m
a
y
n
o
t
b
e
a
l
t
e
r
e
d
,
d
u
p
l
i
c
a
t
e
d
,
u
s
e
d
o
r
d
i
s
c
l
o
s
e
d
w
i
t
h
o
u
t
w
r
i
t
t
e
n
c
o
n
s
e
n
t
f
r
o
m
I
M
P
A
C
T
D
r
a
f
t
i
n
g
&
D
e
s
i
g
n
I
n
c
.
scale is correct if
printed on D-Size paper
by IMPACT Drafting
Note: IMPACT Drafting & Design Inc. is not responsible for engineering or
construction. Individual contractors are responsible for meeting codes.
I
M
P
A
C
T
3
7
3/16" = 1'
F
o
u
n
d
a
t
i
o
n
F
i
r
s
t
F
l
o
o
r
F
r
a
m
i
n
g
s
c
a
l
e
:
3
/
1
6
"
=
1
'
S
l
a
b
F
o
u
n
d
a
t
i
o
n
a
l
l
b
e
l
o
w
-
g
r
a
d
e
c
o
n
c
r
e
t
e
m
u
s
t
h
a
v
e
w
a
t
e
r
p
r
o
o
f
c
o
a
t
i
n
g
GENERAL NOTES:- All below grade level concrete to be covered withapproved foundation coating.- IMPACT recommends top of concrete to be12"-18" above top of curb, min.FLOOR FRAMING NOTES: - double joists or beam under parallel bearing walls - lateral restraint (blocking) at all intermediate supportlocations (cripple walls) - solid blocking at any cantilever and under braced walllinesCLOTHES DRYER VENTING:(IMC 504.6.7) - max. length shall not exceed 35' from dryer locationto outlet terminal - length reduced by 2'6" for each 45° bend - length reduced by 5' for each 90° bendexception: where make and model clothes dryer isknown and of manufacturer's installation instructionsprovided to code official, manufacturer's spec.s may beused.ANCHOR BOLTS: to go 7" into concrete and locatedwithin 12", but not less than 7 bolt diameters, from theends of each plate, with a max. spacing of 6' O.C. (4'O.C. for buildings over 2 stories); min. 2 bolts per plate,w. 3"x3"x.229" sq. washer (per IRC R403.1.6, 602.11.1)
R
e
v
i
s
e
d
b
y
:
D
a
t
e
:
A
d
d
i
t
i
o
n
a
l
R
e
v
i
s
i
o
n
s
D
.
J
o
h
n
s
t
o
n
1
1
A
p
r
1
8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-