Loading...
HomeMy WebLinkAboutL702 Landscape Irrigation Details 08-09-18RAINBIRD SJ127575 PRE-FAB SWING JOINT OR EQUIVALENT LATERAL PIPE LATERAL TEE OR ELL FINISH GRADEMODEL I20-04 ROTOR HEAD OR EQUIVALENTT CHRISTY ID. TAG MODEL PROS-04 OR EQUIVALENT LATERAL PIPE FINISH GRADE LATERAL TEE OR ELL SWING JOINT: RAINBIRD SA125050 OR EQUIVALENT REMOTE CONTROL VALVE SCH 80 PVC SOLVENT WELDED UNIONS SDR 21 PVC LATERAL PIPE NIBCO T-113 BRONZE GATE VALVE OR EQUIVALENT SCH 40 MALE ADAPTOR FINISH GRADE 10" VALVE BOX W/LOCKING LID SCH 40 PVC MAIN LINE 18" 12"18"12"18" 18" INTERIOR OR EXTERIOR WALL 15 1/2" CONTROLLER MODEL PER PLAN MINIMUM CLEARANCE FOR DOOR OPENING CONTROL WIRE CONDUIT, UP TO 2 1/2" SIZE. 3/4" POWER SUPPLY CONDUIT J-BOX INSIDE CONTROLLER CONNECT PER LOCAL CODE ADDITIONAL CONTROL WIRE CONDUIT, UP TO 2" SIZE. SUPPLEMENTAL GROUND WIRE INSTALL PER ASIC GUIDELINES SUPER JUMBO VALVE BOX FINISH GRADE -SEE NOTE 18-24" COILED WIRE WATERPROOF CONNECTORS (2) BRICK SUPPORTS (7) SCH 80 T.O.E. NIPPLE MAIN LINE PIPE & FITTINGS 3/4" MINUS WASHED GRAVEL DRIP ZONE KIT LATERAL PIPE AND FITTINGS PVC SLIP UNIONS (2) NOTE: FOR MOST ACCURATE TEMPERATURE SENSING, ROTATE THE MWS SO THAT THE THERMOSTAT PORTION POINTS SOUTH. THE MWS IS DESIGNED TO MOUNT ON A POST OF 2" PIPE, ANY COMBINATION OF PIPE AND FITTINGS MAY BE USED. 2" PIPE MOUNT TO POST OR WALL WITH CONDUIT CLAMPS MODEL MWS-FR OR SIMILAR OPTIMUM MOUNTING HEIGHT 6' ABOVE GRADE RUN LEAD WIRES TO CONTROLLER 1 L701 NTS Irrigation Controller Detail 9 L701 NTS Irrigation Control Valve - TURF VALVE BOX WITH LOCKING LID FINISH GRADE - SEE NOTE WATERPROOF CONNECTIONS (2) 18-24" COILED WIRE SCH. 80 TOE NIPPLE SCH. 40 FITTINGS BRICK SUPPORTS (4) 3 4" MINUS WASHED GRAVEL 10 L701 NTS Irrigation Control Valve - DRIP 3 L701 NTS Mini Weather Station - Hunter or Equivalent 11 L701 NTS Hunter Pro Spray or Equivalent 12 L701 NTS Rotor Detail 4 L702 NTS Quick Coupler 8 L701 NTS Isolation Valve 2 L701 NTS Backflow Preventer 5 L701 NTS Trenching Details FINISH GRADE LATERAL LATERAL MAIN LINE BEDDING LOW VOLTAGE WIRE LOW VOLTAGE WIRE SECTIONS PLANS SNAKE ALL LATERAL PIPE IN TRENCH TAPE AND BUNDLE ALL WIRING AT 10' INTERVALS. USE 6" WIDE MARKING TAPE 6" ABOVE ALL DIRECT BURIAL WIRING. ALL SPLICES SHALL BE MADE IN VALVE BOXES AND LOCATED ON AS-BUILT PLANS. ALL 120V. WIRING SHALL BE IN CONDUIT WITH MARKER TAPE AS ABOVE. ALL WIRING UNDER PAVEMENT AND THROUGH SLEEVES SHALL BE IN CONDUIT. TIE A LOOSE 20" LOOP IN WIRING AT ALL CHANGES IN DIRECTION GREATER THAN 30 DEGREES. UNTIE ALL LOOPS AFTER MAKING CONNECTIONS FINISH GRADE MARKING TAPE TIES LOOP DIRECT BURY SECTION CONDUIT SECTION DIRECT BURY PLAN CONDUIT PLAN NOTE: FINISH GRADES AT VALVE BOXES MUST BE AT A LEVEL SUCH THAT THE ESTABLISHED TURF OR MULCH SURFACE WILL FLUSH WITH THE TOP OF THE BOX.NOTE: FINISH GRADES AT VALVE BOXES MUST BE AT A LEVEL SUCH THAT THE ESTABLISHED TURF OR MULCH SURFACE WILL FLUSH WITH THE TOP OF THE BOX. NOTE: FINISH GRADES AT VALVE BOXES MUST BE AT A LEVEL SUCH THAT THE ESTABLISHED TURF OR MULCH SURFACE WILL FLUSH WITH THE TOP OF THE BOX. NOTE: FINISH GRADES AT VALVE BOXES MUST BE AT A LEVEL SUCH THAT THE ESTABLISHED TURF OR MULCH SURFACE WILL FLUSH WITH THE TOP OF THE BOX. NOTE: FINISH GRADES AT VALVE BOXES MUST BE AT A LEVEL SUCH THAT THE ESTABLISHED TURF OR MULCH SURFACE WILL FLUSH WITH THE TOP OF THE BOX. NOTE: FINISH GRADES AT VALVE BOXES MUST BE AT A LEVEL SUCH THAT THE ESTABLISHED TURF OR MULCH SURFACE WILL FLUSH WITH THE TOP OF THE BOX. QUICK COUPLING VALVE: RAINBIRD HQ44-RC OR EQUIVALENT 34" ROUND VALVE BOX WITH LOCKING LID 3 INCH MINIMUM DEPTH OF 34" WASHED GRAVEL BRICK (1 OF 2) PVC SCH. 80 NIPPLE PVC 1X1 TXT COUPLING LASCO G132212 SWING JOINT PVC OR POLY MAINLINE PIPE PER PLAN 36" #4 REBAR WITH STAINLESS STEEL GEAR CLAMPS FINISH GRADE. EQ.EQ. 7 L701 NTS Valve Box Layout IRRIGATION CONTROL VALVE BOX PROVIDE EQUAL SPACING BETWEEN BOXES EDGE OF PAVEMENT ALIGN BOXES PARALLEL TO THE EDGE OF PAVEMENT PLACE BOXES A MINIMUM OF ONE (1) FOOT FROM EDGE OF PAVEMENT (1) FINISHED GRADE NOTES 1.1 12" BACKFLOW ASSEMBLY, PER LOCAL CODES AND ORDINANCES 2.PRESSURE VACUUM BREAKERS MUST BE INSTALLED AT LEAST 12" ABOVE DOWNSTREAM PIPING 3.ALL NIPPLES AND VALVES TO BE COPPER OR BRASS MANUAL BRASS SHUTOFF BALL VALVE MANUAL BRASS SHUTOFF BALL VALVE WINTERIZATION ASSEMBLY TO BE INSTALLED AS CLOSE TO BACKFLOW PREVENTER AS POSSIBLE. 1"x4" CEDAR PANEL BACKFLOW ENCLOSURE NOTE: GROUP SIMILAR BOX TYPES AND SIZES TOGETHER, I.E. PLACE RECTANGULAR OR ROUND BOXES TOGETHER. FINISH GRADE SCH. 40 PVC SLEEVE - 4" MIN. OR 2X THE O.D. OF THE IRRIGATION PIPING WRAP 12 GAUGE WIRE AROUND EACH END OF THE SLEEVE AND EXTEND TO THE SURFACE WASHED AND GRADED MORTAR SAND BACKFILL IN ROCKY SOIL. PAVEMENT EDGE 6 L701 NTS Irrigation Sleeve NOTE: 1.CAP SLEEVES UNTIL USE. 2.4" MIN. HORIZONTAL SEPARATION REQUIRED BETWEEN SLEEVES IN THE SAME TRENCH. 3.IRRIGATION PIPE AND CONTROL WIRES SHALL BE SLEEVED SEPARATELY. 4.SOIL AROUND SLEEVE BACKFILLED AND COMPACTED TO THE SAME DENSITY AS THE SURROUNDING SOIL. 1' MIN. DEPTH PER TRENCHING DETAIL Irrigation Details L 702 design5la.com 406.587.4873 date issue dr a w n b y : ch e c k e d b y : fi l e n a m e : z: \ b g m i l l \ a u t o c a d \ 0 1 _ s h e e t s \ l 7 0 1 _ b g m i l l _ i r r i g a t i o n d e t a i l s . d w g BG M i l l Bo z e m a n , M o n t a n a KH M TM S COB Submittal04/05/17 COB Submittal04/12/17 COB Submittal05/24/17 COB Submittal/REV 301/08/18 COB Submittal/REV 406/03/18 COB Submittal/REV 508/08/18