HomeMy WebLinkAboutC2.2 BG Storm Water Details 09-06-18STORMTECH ENDCAP, TYP. OF 2 WRAP WITH GEOTEX 601 NON-WOVEN FABRIC OR EQUIVALENT CONNECT CHAMBERS, TYP. CHAMBER 1 CHAMBER 3 18" ADS N-12 CORRUGATED PIPE, BOTTOM OF PIPE FLUSH WITH BOTTOM OF CHAMBER SOLID TRAFFIC RATED LID 90.7" ACTUAL LENGTH 85.4" INSTALLED NOMINAL CHAMBER SPECIFICATIONS SIZE (W x H x INSTALLED LENGTH) - CHAMBER STORAGE - MINIMUM INSTALLED STORAGE - WEIGHT - 30.0" 51.0" x 30.0" x 85.4" 45.9 CUBIC FEET 74.9 CUBIC FEET 74 LBS.51" A B A C MATERIAL LOCATION DESCRIPTION C FILL MATERIAL FOR 6" TO 18" ELEVATION ABOVE CHAMBERS (24" FOR UNPAVED INSTALLATIONS) EMBEDMENT STONE SURROUNDING AND TO A 6" ELEVATION ABOVE CHAMBERS B GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES. CLEAN ANGULAR STONE WITH THE MAJORITY OF PARTICLES BETWEEN ¾ - 2 INCH FOUNDATION STONE BELOW CHAMBERS A CLEAN ANGULAR STONE WITH THE MAJORITY OF PARTICLES BETWEEN ¾ - 2 INCH AASHTO M43 DESIGNATION 3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10 3, 357, 4, 467, 5, 56, 57 3, 357, 4, 467, 5, 56, 57 N/A N/A A-1 A-2 A-3 AASHTO M145 DESIGNATION COMPACTION/DENSITY REQUIREMENT COMPACT IN 6" LIFTS TO A MINIMUM 95% STANDARD PROCTOR DENSITY. ROLLER GROSS VEHICLE WEIGHT NOT TO EXCEED 12,000 LBS. DYNAMIC FORCE NOT TO EXCEED 20,000 LBS. NO COMPACTION REQUIRED PLATE COMPACT OR ROLL TO ACHIEVE A 95% STANDARD PROCTOR DENSITY ACCEPTABLE FILL MATERIALS STORMTECH SC-740 CHAMBER SYSTEMS NOTE: THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN CRUSHED ANGULAR. INSTALL 3 ROWS OF 3 CHAMBERS (9 CHAMBERS TOTAL) 36" I.D. STANDARD STRAIGHT MANHOLE PER COB STD DTL 02720-4 18" ADS N-12 CORRUGATED PIPE, BOTTOM OF PIPE FLUSH w/ BOTTOM OF CHAMBER GEOTEX 601 NON-WOVEN FABRIC ALL AROUND ANGULAR STONE ISOLATOR ROW GEOTEX 601 NON-WOVEN FABRIC ALL AROUND ISOLATOR ROW BETWEEN CHAMBER & ANGULAR STONE 3 ROWS OF (3) SC-740 CHAMBERS (9 CHAMBERS TOTAL) MIN. 6" 12" 30" 12" MIN. TYP.51" 11' 18" Ø ISOLATOR ROW INLET NON-ISOLATION ROW COVER ENTIRE ISOLATOR ROW WITH ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE 8' (2.4 m) MIN WIDE TWO LAYERS OF ADS GEOSYNTHETICS 315WTK WOVEN GEOTEXTILE BETWEEN FOUNDATION STONE AND CHAMBERS 5' (1.5 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS AT BOTTOM OF CHAMBER 6" DTL 4/C2.2 ± 30" WELL DRAINING GRAVEL AS REQUIRED TO REACH NATIVE GRAVEL BELOW ± 30" 4" PERVIOUS PAVERS MIRAGRID 5XT GEOGRID 4" OF COMPACTED BEDDING STONE 3 4" TO 1", CLEAN, ANGULAR, NO FINES COMPACTED WELL-DRAINING GRAVEL NATIVE SUBGRADE 12" SUMP ELEV. 4786.00' 8.0' (96") 36" I.D CONCRETE STANDARD STRAIGHT MANHOLE PER COB STD DTL 02720-4 6" PRECAST BASE DTL 3/C2.2 18"Ø ISOLATOR ROW OUTLET 4.0' (48") EL. 4778.0' 12" 4"Ø HDPE INV. IN EL. 4780.5' 6" INV. OUT EL. 4779.5' ±10" PAVEDRAIN PERVIOUS PAVERS MIRAGRID 5XT GEOGRID COMPACTED BEDDING STONE 3 4" TO 1", CLEAN, ANGULAR, NO FINES COMPACTED STONE 2" TO 3", CLEAN, ANGULAR, NO FINES 20" 4" 5.65" VARIES (12" TYP.) CONCRETE BORDER MIRIFI 580iRS GEOFABRIC 1% NATIVE SUBGRADE NOTE: INSTALL PAVEDRAIN PERVIOUS PAVERS ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. 4' BOULEVARD 2% CONCRETE SIDEWALK PER CITY STANDARDS PAVEDRAIN PERVIOUS PAVERS, INSTALL PER MANUF. RECOMMENDATIONS 6" OF COMPACTED BEDDING STONE 3 4" TO 1", CLEAN, ANGULAR, NO FINES MIRIFI 580iRS GEOFABRIC INTEGRAL CURB & GUTTER PER CITY STANDARDS ISSUE DATE REVISION SCHEDULE NUMBER DATE SHEET NUMBER WARNING IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE 0 1/2"1" DRAWN BY: DESIGNED BY: CHECKED BY: 21 5 0 A n a l y s i s D r i v e , S t e . B Bo z e m a n , M T 5 9 7 1 8 Ph o n e : ( 4 0 6 ) 5 8 5 - 0 5 9 0 Fa x : ( 4 0 6 ) 5 8 2 - 1 0 5 7 in f o @ b r i d g e r e n g i n e e r s . c o m BR I D G E R E N G I N E E R S , I N C . CI V I L a n d S T R U C T U R A L EN G I N E E R I N G PR O J E C T M A N A G E M E N T BE I 71 4 E . M E N D E N H A L L S T R E E T , B O Z E M A N , M T P:\ P r o j e c t s \ P e a r s o n D e s i g n G r o u p \ B G M i l l P r o p e r t y \ C A D \ B G M I L L - C I V I L D E T A I L S . d w g BG M I L L MD MD ST O R M W A T E R D E T A I L S 04.05.2017 1 2 3 06.08.2018 08.08.2018 09.06.2018 C2.2