Loading...
HomeMy WebLinkAboutA2.6_Main Floor Plan - Office Suite 2 03-16-187 9 10 11 12 13 A B C D E F G H I J L K 8 7 9 10 11 12 138 Bo z e m a n M o n t a n a A C O M M E R C I A L / M I X E D U S E P R O J E C T F O R : TH E M O N A R C H Lo t 1 - A - 2 10-11-17 17.115ev2 Job #: CONCEPT REVIEW 11-21-17SITE PLAN REVIEW T.B.D.95% PERMIT SET 1535 liberty lane suite 110b missoula, montana 59808 phone: 406.540.4437 design inc A2.61,194 NET SQ FT SCALE :1 Office Suite 2 1/4" = 1'-0" NN 1 A2.8 Keyed Notes - Floor Plan EXTERIOR FLOOR DRAIN, COORDINATE WITH MECHANICAL & CIVIL. CONSTRUCTION DESIGNATION Legend - Building Plans SYMBOL DESIGNATION 6" DIM. FROM FACE OF STUD TO INSIDE OF FINISH FRAME, TYP. AT ALL DOORS, U.N.O. CLEAR FLOOR SPACE REQUIRED FOR ACCESSIBILITY 1 HOUR FIRE BARRIER CONSTRUCTION 1 HOUR FIRE BARRIER ASSEMBLY NEW CONSTRUCTION NOT REQUIRE TO BE FIRE BARRIER RATED DOOR & FRAME, SEE DOOR SCHEDULE ROOM NAME ROOM NUMBER DOOR TAG - SEE SCHEDULE (SEE OVERALL FLOOR PLANS) WINDOW TAG - SEE SCHEDULE (SEE OVERALL FLOOR PLANS) WALL TYPES - SEE A0.2 A5.1 1 2 3 4 SHEET NUMBER INTERIOR ELEVATION NUMBER CPT#RF FLOORING DESIGNATION, SEE FINISH PLANS FLOOR DRAIN, SEE MECHFD SLAB JOINT PROVIDE SELANTSJ SECTION CUT INDICATES ACCESSIBLE SPACE GRID LINE CONCRETE METAL AWNING BELOW, SEE AWNING PLANS ONA2.12 42" GUARD RAIL SEE DETAILS ON A8.4 ## A#.# # ROOM RM# I-A EGRESS WINDOW, SEE WINDOW SCHEDULE(E) TEMPERED GLASS, SEE WINDOW SCHEDULE(T) EXTERIOR RATED WALL - SEE A0.2 FOR WALL ASSEMBLY, SEE ELEVATIONS FOR SIDING TYPE E-# 24" DEEP SHELF W/ CLOSET ROD, SEE SPEC. FURRED OUT WALL, SEE A0.2 ASSEMBLIES TYPICAL CONSTRUCTION FOUNDATION WALL, SEE STRUCTURAL FLOOR DRAIN, SEE MECHANICAL 0.5 HOUR FIRE BARRIER CONSTRUCTION 0.5 HOUR FIRE BARRIER ASSEMBLY NEW CONSTRUCTION NOT REQUIRE TO BE FIRE BARRIER RATED DOOR & FRAME, SEE DOOR SCHEDULE EXT. FIRE BARRIER WALL SUPPORTING CONSTRUCTION, SEE A0.2 ASSEMBLIES HATCH DESIGNATION GRAVEL AT BOTTOM OF WINDOW WELL METAL AWNING ABOVE, SEE AWNING PLANS ON A2.12 T.S. COLUMN AND INTEGRATED DOWN SPOUT, SEE AWNING PLANS AND STRUCTURAL T.S. COLUMN AND INTEGRATED DOWN SPOUT, SEE AWNING PLANS AND CIVIL FOR DRAINAGE 1.USE WRITTEN DIMENSIONS, DO NOT SCALE DRAWINGS. USE WRITTEN DIMENSIONS. DO NOT SCALE DRAWINGS. WHERE NO DIMENSION IS PROVIDED, CONSULT ENCOMPASS FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR SHALL BE COGNIZANT THAT THIS IS A REMODEL PROJECT AND AS SUCH CERTAIN ITEMS CANNOT BE FULLY SHOWN OR EXPLAINED WITHOUT FIELD OBSERVATION & VERIFICATION. THEREFORE PRIOR TO SUBMITTING THE PROPOSAL THE CONTRACTOR & SUBCONTRACTORS SHALL VISIT & EXAMINE THE SITE & BLDG IN DETAIL & MAKE ALLOWANCES FOR ALL CONDITIONS THAT EFFECT WORK. 2.DIMENSIONS ARE FROM EITHER; FACE OF STUD AT NEW WALLS, OR FACE OF GWB AT EXISTING WALLS. SEE WALL TYPES FOR ADDITIONAL WALL ASSEMBLY INFORMATION. 3.SET DOOR ROUGH OPENINGS 6" FROM F.O.S., TYP. U.N.O. 4.NOT USED. 5.PROVIDE 2x6 BLOCKING FOR ALL CABINETRY, GRAB BARS, TOILET ACCESSORIES, TRAVERSE RODS, ETC. 6.SEE RCP & MECHANICAL PLANS FOR ALL SOFFIT LOCATIONS & DUCT RUNS, TYP. 7.COORDINATE LIGHTING LAYOUT, SEE RCP AND ELECTRICAL DRAWINGS. 8.DASHED LINES AT DOORS, KITCHENS AND BATHROOMS INDICATE CODE REQUIRED CLEAR FLOOR SPACE FOR ACCESSIBILITY. CONTRACTOR TO COORDINATE. SEE CODE PLANS. 9.WHERE RATED ASSEMBLIES ABUT OTHER ASSEMBLIES, CONTRACTOR TO PROVIDE ADDITIONAL LAYERS OF SHEATHING, SOUND CHANNEL, GWB, ETC. TO PROVIDE A SMOOTH, UNIFORM FINISHED SURFACE FOR ENTIRE LENGTH OF WALL. 10.SHELF MOUNTING HEIGHTS THAT ARE ADA COMPATIBLE TO BE MAX 48" A.F.F. HEIGHT. 11.ALL EXPOSED STRUCTURE, HVAC, CONDUIT, ECT. TO BE PAINTED, VERIFY COLOR W/ ARCH. 12.GWB TO TRIM & FINISH AROUND BEAMS & JOISTS THAT PENETRATE ASSEMBLIES, TYP. 13.USE WATER RESISTANT GWB IN ALL WET ROOMS. (EI. BATHROOMS, LAUNDRY ROOMS, WATER HEATER ROOMS, ETC) 14.SEE A5.1 & A5.2 FOR ADA DETAILS. 15.SEE A7.1 FOR INTERIOR FLOOR BASE & FLOORING TRANSITION DETAILS. 16.SEE A7.1 FOR DOOR AND WINDOW DETAILS. 17.ALL DOORS, WINDOWS, PLUMBING, ETC TO REMAIN SHALL BE PROTECTED AS REQUIRED DURING CONSTRUCTION. 18.VERIFY ALL HARDWARE WITH OWNER, PROVIDE ALLOWANCES. General Notes - Building Plans 1 A4.4 1 SIM A4.3 2 SIM A4.3 1 A2.11 6 A8.5 10 A8.1 7 SIM A8.2 6 A8.5 MA T C H L I N E , S E E A 2 . 5 MA T C H L I N E , S E E A 2 . 5 EL E C T R I C A L ME T E R S , SE E E L E C GA S ME T E R S , SE E M E C H OFFICE 2 102 MENS 105 MECH 106 BREAK ROOM 103 STAIRS 107 DECK EXT103 DECK EXT102 ℄ I-E I-E I-E I-C*I-C* 6'-0" 26 ' - 0 " 9'- 0 " 17 ' - 0 " 20'-0" 9'- 0 " 14'-0" 5'- 0 " 5' - 6 1 / 2 " 8' - 6 " 11 ' - 6 " 9' - 6 1 / 2 " 11'-0"11'-6 1/2"20'-0" 35 ' - 1 " 15'-5 1/2"16'-1" 25 ' - 6 1 / 2 " 31 ' - 1 " 4'- 0 " 10 ' - 0 " 1' - 0 " T Y P 6'- 0 " 4'- 0 " 5'- 0 " 20 ' - 0 " 5'- 0 " E-1*E-1* E-1*E-1* E-1* E-1* E-1*E-1*E-1* E-1* THIS SHEET IS INTENDED TO BE PRINTED IN COLOR TO FULLY UNDERSTAND THE INFORMATION BEING PRESENTED. CONCEALED BEAM WITHIN FLOOR ASSEMBLY, SEE SECTIONS AND STRUCTURAL. ADJACENT ROOM, INFORMATION NOT SHOWN FOR CLARITY ON THIS PLAN SC1 WD1 T1 INTERIOR CONCRETE - SEALED NOTE: EXTERIOR CONCRETE NOT SEALED WOOD LOOK FLOORING - TAS FLOORING : TANDEM TILE : NORWICH CW1 5/4 P.T. WOOD DECKING, STAIN. CERAMIC TILE FLOORING NOTE: OFFICE ONLY CONC = WD = TILE = GWB CW = GYPSUM WALL BOARD - SEE ASSEMBLIES SHEET A0.2 WM WALK-OFF MATT NOTE: STAIR ONLYWM =T2 CERAMIC TILE FLOORING NOTE: OFFICE ONLY TILE = RF1 RESILIENT FLOORINGRF = CPT1 CARPETCPT = Legend - Finish Plan T3 CERAMIC TILE FLOORING NOTE: RESIDENTIAL ONLY TILE = ROOM # 101 AREA NAME FLOOR WALLS TRIM, WINDOWS & DOORS CEILINGBASE 102 103 104 105 106 107 OFFICE 1 OFFICE 2 Break Room Mens Stair Mech Womens WD1 WM / CPT1 B-2/ P-2 B-1 P-1 P-1 TR-1/ P-2 MILLWORK CB-1/ CT-1 P-1 P-1 P-1 P-1 P-1 P-1 P-1 B-2/ P-2 P-1 NOTES TR-1/ P-2 TR-1/ P-2 TR-1/ P-2 TR-1/ P-2 TR-1/ P-2 TR-1/ P-2 P-1 P-1 P-1 P-1 WD1 T2 T1 T1 RF1 ** SEE INTERIOR FINISH NOTES ON A5.3Finish Schedule - Main Floor Offices B-3 B-3 B-3 1 1 NOTES: 1. PAINT ALL EXPOSED DUCTWORK WITH DRY FALL FLAT PAINT, 2 COATS MINIMUM. EXT101 Deck CW1 --- SEE ELEVS SEE ELEVATIONS SEE ELEVS EXT102 Deck CW1 --- SEE ELEVS SEE ELEVATIONS SEE ELEVS EXT103 Deck CW1 --- SEE ELEVS SEE ELEVATIONS SEE ELEVS B-2/ P-2 CHASE FOR HOSE BIB, SEE MECHANICAL. PROVIDE INTERIOR CHASE DIMENSIONS OF 6" CLR x 8" CLR.10 A7.1 HOSE BIB, SEE MECHHB X 1' - 0 " T Y P FD 1 2 3 LANDING LANDING LANDING DN 1194 NET SQ FT FD FDC DN DN DN DN DN WINDOW WELL BELOW WINDOW WELL BELOW FD SEE CIVIL FOR FULL EXTENT OF SIDEWALKS & LANDSCAPING SEE CIVIL FOR FULL EXTENT OF PARKING LOT, SIDEWALKS & LANDSCAPING 340 NET SQ FT SEE 2 HB FD 3 FD 3 BASEMENT ENTRANCE BELOW AWNING ROOF D.S. D.S. 2'-0" 2'-0" 43'-0" 6'-0"12'-0"3'-0" 43'-0" 6'-0"12'-0"3'-0"17'-0" 4'- 0 " 5'- 0 " 4'- 0 " 3' - 0 " 15 ' - 0 " 4'- 0 " 2'- 0 " 3'- 0 " 2'- 0 " 56 ' - 0 " 17'-0" 9'-0" 11 ' - 0 " 3'- 0 " 9'-0" 11'-0"32'-0" 40 ' - 0 " 11'-0"32'-0" MDF, PAINTED. RUBBER BASE. MDF WALL BASE, PAINTED. TR-1 = B-1 = B-2 = PAINT - WALLS & CEILINGS, V.W.O.P-1 = PAINT - FLOOR BASE, WINDOWS AND DOOR TRIM, V.W.O.P-2 = CABINETS - BELMONT 1600 SERIES: TERRA: CARBON. V.W.O.CB-1 = COUNTERTOPS - QUARTZ: WHITE. V.W.O.CT-1 =TILE WALL BASE, TO MATCH FLOOR TILE.B-3 = HOLD EXPOSED DUCTWORK TIGHT TO CEILING. PAINT ALL EXPOSED DUCTWORK WITH DRY FALL FLAT PAINT, 2 COATS MINIMUM. SEE MECHANICAL 4 LIGHTING, SEE ELECTRICAL ELECTRICAL EQUIPMENT, SEE ELECTRICAL 12 SIM A7.1 13 SIM A7.1 14 SIM A7.1 SCALE :2 Office Suite 2 - RCP 1/8" = 1'-0" NN 2 A2.8 RCP INFORMATION OF ADJACENT ROOMS NOT SHOWN FOR CLARITY, SEE 2/A2.8 OFFICE 2 102 MENS 105 MECH 106 BREAK ROOM 103 STAIRS 107 B.O. EXPOSED DUCTWORK 10'-10" ± A.F.F. V.I.F. B.O. FLAT CEILING 12'-9 1/2" ± A.F.F. B.O. EXPOSED DUCTWORK 11'-0" ± A.F.F. V.I.F. B.O. EXPOSED DUCTWORK 11'-2 1/2" ± A.F.F. V.I.F.1 4 3 A2.8 FINISH INFORMATION OF ADJACENT ROOMS NOT SHOWN FOR CLARITY, SEE 3/A2.8 SCALE :3 Office Suite 2 - Finish Foor Plan 1/8" = 1'-0" NN EL E C T R I C A L ME T E R S , SE E E L E C GA S ME T E R S , SE E M E C H OFFICE 2 102 MENS 105 MECH 106 BREAK ROOM 103 STAIRS 107 DECK EXT103 DECK EXT102 FDC DN DN WINDOW WELL BELOW WINDOW WELL BELOW SEE BUILDING FLOOR PLAN ON A2.1 FOR FULL EXTENT OF DECK BASEMENT ENTRANCE BELOW AWNING ROOF 3FD 3 FD