Loading...
HomeMy WebLinkAboutA-104 - FLOOR PLAN - OVERALL - ROOF - 12-17-20193 1245 A1 A2 A3 A4 A5 A6 A7 A8 A9 678910 11 3.5 B3 B1 12 13 14 15 C1 C2 C3 16 17 18 19 20 21 27 28 22 29 D8 D7 D4 D3 D2 D1 B2 C5 C6 C7 C4 23 24 25 26 D5 E1 E2 E4 E5 E7 E10 E11 E6 E3 D6 E8 E9 3/ 8 " / 1 2 " 3/ 8 " / 1 2 " 3/ 8 " / 1 2 " 1/ 2 " / 1 2 " 1/ 2 " / 1 2 " 3/8" / 12" 3/8" / 12" 3/8" / 12" 3/8" / 12" 3/ 8 " / 1 2 " 3/ 8 " / 1 2 " 3/8" / 12" 3/ 8 " / 1 2 " 1/ 2 " / 1 2 " 3/8" / 12" 3/8" / 12" 3/8" / 12" 3/8" / 12" 3/8" / 12" 3/ 8 " / 1 2 " 3/ 8 " / 1 2 " 3/8" / 12" 2301 504 1/ 4 " / 1 2 " RA1 RA1 RA1 RA1 RA1 RA1 RA1 RA1 711 303 303 711 303 303 303 303 303 303 303 3/ 8 " / 1 2 " 3/ 8 " / 1 2 " 1401 1401 2608 2606 2607 2302 2607 A-206 32 5 6 820 819 819 819 819 GENERAL NOTES 1. PROVIDE MINIMUM VALLEY SLOPES OF 1/8" PER FOOT 2. PROVIDE TEXTURED WALKWAY FROM STAIR ACCESS TO ALL MAINTAINABLE EQUIPMENT 3. ROUTE OVERLOW DRAINS TO LAMBS TONGUES 2'-0" ABOVE GRADE. ROUTE ROOF DRAINS TO STORM SEWER PIPE WORK NOTES FULLY ADHERED TPO ROOF ASSEMBLY (SLOPED STRUCTURE) ROOF SUMP WITH ROOF DRAIN AND OVERFLOW DRAIN. SLOPE AT 1/2" / 12" U.N.O. TAPERED INSULATION. SLOPE AT 1/2" / 12" LEGEND Project Number: Drawn By: Reviewed By: Approved By: Issue Date ThinkOne Architects 101 E Main St. Studio 1 Bozeman, MT, 59715 T: 406-586-7020 Architect MEP Engineer Associate Architect Landscape Architect Information Technology Civil Engineer Seal Project Number Acoustical Engineer TCA Architecture + Planning 6211 Roosevelt Way Ne Seattle, WA 58115 T: 206-522-3830 Associated Construction Engineering Inc. 12 N Broadway Belgrade, MT, 59714 T: 406-388-3320 Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Design 5 Landscape Architecture 37 E Main St Bozeman, MT, 59715 T: 406-587-4873 BCER Engineering 10807 New Allegiance Dr., Suite 400 Colorado Springs, CO 80921 T: 719-533-1112 Big Sky Acoustics PO BOX 27 Helena, MT 59624 T: 406-457-0407 City of Bozeman 121 N Rouse Ave. Bozeman, MT 59715 T: 406-582-2300 F: 406-582-2301 901 N. ROUSE AVE. & 300 E. OAK ST., BOZEMAN MT AndersonMasonDale Architects, P.C. 3198 Speer Boulevard Denver, CO 80211 T: 303-294-9448 Associate Architect Structural Engineer Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 SITE PLAN APPLICATION DECEMBER 17, 2019 12 / 1 0 / 2 0 1 9 1 1 : 4 4 : 2 5 A M A-104 FLOOR PLAN - OVERALL - ROOF 1825 AMD SH JT BOZEMAN PUBLIC SAFETY CENTER 1825 CITY OF BOZEMAN 8'32'4' 16' 1/16" = 1'-0" FLOOR PLAN - OVERALL - ROOF TRUE NORTH 2607 FUTURE BALLASTED PV ARRAY LOCATION, LAYOUT TBD, RE: ELECTRICAL 2608 HEAT TRACE TO BE PROVIDED AT GUTTER, RE: ELECTRICAL 303 PRE-CAST SPLASH BLOCK 504 SCREEN WALL. METAL PANEL CLADDING ON GALV. PAINTED HSS STEEL STRUCTURE, RE: ELEVATIONS 711 CONDUCTOR HEAD AND DOWNSPOUT 819 SOLATUBE, 21" 820 GLASS ENTRY CANOPY 1/2" PER FOOT SLOPE ONTO FD CANOPY 1401 ELEVATOR OVERRUN 2301 MECHANICAL UNIT ON PRE-FABRICATED CURB, RE: MECH 2302 SOLAR WALL, RE:MECH 2606 BALLASTED PV ARRAY, APPROX. 50KW, RE: ELECTRICAL