HomeMy WebLinkAboutA-003 - SITE PLAN - ENLARGED - AREA B - 12-17-20199 9 9 9 11 6 7 11 2 BOZEMAN PUBLIC SAFETY CENTER NORTH ROUSE AVE -ARTERIAL (ADJACENT M-1 ZONING) SNOW-MELT SYSTEM COVERED TRASH/RECYCLING ENTER EXIT CONVAULT (2000 GAL.) - ON 10" CONC. PAD FUTURE NWE SUPER CAPACITOR U.G. 2000 GAL. PROPANE TANK - PER MECH. 8'-0" STEEL SLAT AND TWO RAIL WITH PRIVACY SLATS - MANUFACTURER FINISH. 3'-0" CONCRETE BASE - TYP. NWE ELECTRICAL TRANSFORMER SECURE PARKING 94 PARKING SPACES 9 PARKING CANOPY WITH PV FI R E W A T E R WA T E R SA N . S E W E R FUTURE GAS DIESEL GENERATOR - ON CONC. PAD PER CIVIL FFL = 4763.2 FFL = 4762.2 SN O W S T O R A G E 13'-0" VERTICAL PIVOT GATE T Y P . 18 ' - 0 " FUTURE 10'x8' FACILITIES STORAGE COMMUNICATIONS PROPERTY LINE LANDSCAPE SETBACK AND UTILITY EASEMENT BUILDING SETBACK 4 SERVICE ACCESS SERVICE ACCESS UP ELECTRICAL GAS 11 CHILLER - PER MECH. - ON CONC. PAD PER CIVIL TYP. 11' - 0" UTILITY EASEMENT FUTURE EV CHARGING STATION - TYP. ELECT. METER TY P . 9' - 0 " 50' - 0" REFUSE APPROACH GATE ACCESS SYSTEM BENCH - PER LANDSCAPING DERO HOOP RACK HEAVY DUTY - STAINLESS IN-GROUND - PER LANDSCAPE. - TYP PARKING CANOPY ABOVE ASPHALT PAVING - PER CIVIL - TYP. H.C. SIGNAGE - TYP. - PER CIVIL CONCRETE APRON - PER CIVIL - TYP. CONC. CURB AND GUTTER - PER CIVIL - TYP. SAND/OIL SEPERATOR - PER CIVIL SNOW-MELT SYSTEM V I SION TRIAN G LE ROCKS - PER LANDSCAPE - TYP. FLAG POLE CONC. WALK - PER CIVIL - TYP. 6' - 0" 5' - 0" AREA OF FUTURE EXPANSION SNOW STORAGE 6" CONCRETE BOLLARD - PAINT - TYP. CONCRETE APRON - PER CIVIL - TYP. PATIO PATIO 5' - 0 " 6" CONC. FILLED STL. BOLLARD - PAINT - TYP. A-008 1 A-008 1 A-010 1 A-005 3 FACILITIES STORAGE GAS METER IRRIGATION WELL - PER LANDSCAPE PRESSURE SENSOR TRENCH DRAIN - PER CIVIL SITE LIGHT - PER ELECT. - TYP. 26 ' - 0 " 5' - 0 " TRENCH DRAIN PER CIVIL TY P . 8' - 0 " 12 ' - 0 " TYP. 8' - 0" 18' - 0" TYP 26' - 0" 26 ' - 0 " 26 ' - 0 " 7' - 0" 9' - 0 " 8' - 0 " 9' - 0 " 5' - 0 " TYP. 99' - 0" 8' - 0" 7' - 0" 14 ' - 0 " 20' - 0" 16 ' - 0 " 8' - 0 " 14' - 6" 19 ' - 4 " A-006 1 Project Number: Drawn By: Reviewed By: Approved By: Issue Date ThinkOne Architects 101 E Main St. Studio 1 Bozeman, MT, 59715 T: 406-586-7020 Architect MEP Engineer Associate Architect Landscape Architect Information Technology Civil Engineer Seal Project Number Acoustical Engineer TCA Architecture + Planning 6211 Roosevelt Way Ne Seattle, WA 58115 T: 206-522-3830 Associated Construction Engineering Inc. 12 N Broadway Belgrade, MT, 59714 T: 406-388-3320 Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 Design 5 Landscape Architecture 37 E Main St Bozeman, MT, 59715 T: 406-587-4873 BCER Engineering 10807 New Allegiance Dr., Suite 400 Colorado Springs, CO 80921 T: 719-533-1112 Big Sky Acoustics PO BOX 27 Helena, MT 59624 T: 406-457-0407 City of Bozeman 121 N Rouse Ave. Bozeman, MT 59715 T: 406-582-2300 F: 406-582-2301 901 N. ROUSE AVE. & 300 E. OAK ST., BOZEMAN MT AndersonMasonDale Architects, P.C. 3198 Speer Boulevard Denver, CO 80211 T: 303-294-9448 Associate Architect Structural Engineer Morrison-Maierle, Inc. 2880 Technology Blvd. Bozeman, MT 59715 T: 406-587-0721 SITE PLAN APPLICATION DECEMBER 17, 2019 12 / 2 6 / 2 0 1 9 1 : 2 4 : 1 3 P M A-003 SITE PLAN - ENLARGED - AREA B 1825 Author Checker Approver BOZEMAN PUBLIC SAFETY CENTER 1825 CITY OF BOZEMAN 32" 128" 16" 64" A-003 1" = 20'-0" 1SITE PLAN - ENLARGED - AREA B TRUE NORTH