HomeMy WebLinkAboutC1.0 Overall Site Plan 10-01-2019 LEGEND x EXISTING SPOT ELEVATION LP LOW-POINT x(100.00) PROPOSED SPOT ELEVATION FL FLOWLINE © EXISTING UG POWER BOX TBC TOP BACK OF CURB Q EXISTING TELEPHONE BOX SW SIDEWALK ❑U EXISTING UTILITY BOX FF FINISH FLOOR LS LANDSCAPE I N ® EXISTING SANITARY SEWER MANHOLE TOW TOP OF WALL I © EXISTING STORM SEWER MANHOLE EP EDGE OF O PAVEMENT O°0 EXISTING SANITARY SEWER CLEANOUT BOW BOTTOM F WALL EXISTING FIRE HYDRANT LOT 1, KAGY PARCEL A, COS 1 328A Sheet 1 of 7 CROSSROADS SUBD EVANGELICAL CHURCH OF BOZEMAN EXISTING WATER VALVE /� DEED REF.: BK. 166, PG. 1328 U m EXISTING CURB STOP ` y� KAGY CROSSROADS LLC v C EXISTING POWER POLE DEED REF.: BK. zns.Pc. 3z ° xxt: EXISTING LIGHT POLE ----T 12.2 2 m O _ _ _ _ _ _ _ _ _ _ R-3 w EXISTING WATER WELL R—� I m ® 01 PROPOSED SANITARY SEWER MANHOLE - - - - — — — — — — — — — — — — — — — — — — — — F E"L ® PROPOSED STORM SEWER MANHOLE Scale In Feet m LL e••w e•'w 8"w��e•'w e•'w 8•' e•w 8•w 8"w 8"w 8"w Ww W.w 50 0 50 C c ® PROPOSED STORM SEWER INLET Co PROPOSED SANITARY SEWER CLEANOUT -e•ss e•ss-g-- a•'s e'SS 8"ss 8"ss 8"ss B"ss B"ss— 15 0 15 8 5'BOULEVARD IDEW PROPOSED FIRE HYDRANT 5'SIDEWAL P.) S Scale In cetera C PROPOSED WATER VALVE ' �QCACINTERSECrtQNSs7►RRE - Contour Interuala: f FootPROPOSED CURB STOP o ® PROPOSED LIGHT POLE - SINGLE ARM.z5'-3Q'MQUNTINc Elc - ..- ep J I� C t I - ❑0�'e. o ------ B C�a PROPOSED WATER WELL - N 1 'D� 219M 1� ® — INSTALL PER C.O.B.LIGHTING STA DAR W TRAFFIC FLOW REMIN AY 6o y I ?q 0 cH Ha VISION TRIANGLE PROPERTY BOUNDARY LINE I`r ''`. un oJr AN P -_ __ ___ - J ... SURROUNDING PROPERTY LINE m rI m OT 2, KAGY SETBACK LINE _ J y I < —EASEMENT LINE (n m h of THE BLUE conlDo MASTER z... N kSSROADS SUBD —x—x—x EXISTING FENCE Q � L _ I I �I /`.`. [ rE zeANo a�,� I 1 T oNe EXISTING OVERHEAD ELECTRIC LINE c KAGY BLVD Y(/) I LU I L� uce EXISTING UNDERGROUND ELECTRIC LINE SITE I`7 O Y z I I ( -- -he "Q 16, 26'DRIVE AISLE 10' Qy cns EXISTING GAS LINE F a I I I uWr EXISTING UNDERGROUND PHONE LINE 0) OJ �' I I I Q EXISTING WATER MAIN O a I I to8,9oo LOT sq.'I Fe. - I—I ss EXISTING SANITARY SEWER MAIN " I _ I -` 8 TYR) s EXISTING STORM SEWER � - - Ch 0']z k9''I->� SIDEWA 2.5000 Acres I ` 1 VICINITY MAP - PROPOSED BUILDING I 11 PROPOSED 8" WATER MAIN I ` — 1�1 > I 1ST FLOOR FOOTPRINT=43,652 SF e••ss PROPOSED 8" SANITARY SEWER MAIN C1.0 SCALE:NTS I m NORTH WING FF ELEV.=4912.00 30'WIDE ACCESS AND UTILITY EASEMENT PROPOSED STORM SEWER 122 APT.UNITS I� PER(PLAT J-328 AND J-328-Al sr �(^�] ..... - -V — 3 LQ�J >..... .. o uce PROPOSED UNDERGROUND ELECTRIC LINE = 'E P 9'(TYP.) 7 LOT 3, KAGY cAs PROPOSED GAS LINE ucr PROPOSED UNDERGROUND PHONE LINE ---BIKE AR (TYP) SSROADS SUBD — — —PROPOSED SWALE/RETENTION POND CONTOUR m I I 7�[n�' B�TMP• DRIVE AISLE oo N NO.:2377160 LLc PROPOSED CURB AND GUTTER W 7 1.II 0.1 TYR• :: "'TTT a t O m� Q e PROPOSED WELL BENCHMARK 1ti SET NAIL(C&H CP.50) O o' I I N k9. [N 0'00"W] m ELEVATION=4919.15 FEET(NAVD83) 4 ] 00'00" �Rtl M� LEGAL DESCRIPTION a I I I b C$ IDEW - LOT 1 AND LOT 6,BLOCK 1,KAGY CROSSROADS Q z SUBDIVISION,LOCATED IN SE 1/4,SEC.14,T.1 S.,R.5 E. Y QN I I II u� OF P.M.M.,CITY OF BOZEMAN,GALLATIN COUNTY,MONTANA �j1 _Q O x� SPECIFICATIONS o m I I 26' v- O DRIVE ALL CONSTRUCTION SHALL CONFORM THE FOLLOWING SPECIFICATIONS WHICH ARE O 5' I : U AISLE /--- LOT 4, KAGY ~� HEREBY INCORPORATED BY REFERENCE: _ S AL U 1. MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS,SIXTH EDITION(APRIL 2010) J O}� 1YP) --- o ��n , BROADS SUBD 2. CITY OF BOZEMAN MODIFICATIONS TO MPWSS SIXTH EDITION INCLUDING c�o O 9 �').5j (TYP. IpTOC MAN BALK OF MONTANA ADDENDUMS(2017) (�=^ I I I;:..:: U F DEEDKREF.: BK 2127, PGT968 OWNER _ J--� ---- D&S AMERLIA PROPERTIES INC — LOT 6 NEW uo B-2 3 Z 4300 S FLETCHER AVE O AMELIA ISLAND,FL 32034 O 111,896 Sq.Ft DEVELOPMENT ADDRESS ' � 2.5688 ACRES I'EASE ;� m m w� I I ':: � DRIVE�� 1 N L ________- � 1753 S 22ND AVENUE,BOZEMAN, MT 59718 N ` m GENERAL NOTES Q 2 Be� A D y(TYP) Y WI oa"' VISION TRIANGLE 1. CHANGE OR MODIFICATION OF THE APPROVED PLANS AND SPECIFICATIONS SHALL BE MADE N e y WITHOUT THE PRIOR WRITTEN APPROVAL OF THE ENGINEER AND THE CITY OF BOZEMAN �' ... ENGINEERING DEPARTMENT. FTC O m I ® SIR A K(TYP.) O 2. PRIOR TO THE PRECONSTRUCTION MEETING,THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER AND THE CITY OF BOZEMAN,WORKING DRAWINGS,SPECIFICATION SHEETS,ETC.FOR ALL EQUIPMENT (n 5w I HANDICAP PARKING SIGN PER 03 ,,/ AND MATERIALS TO BE USED ON THE PROJECT. INSTALLATION SHALL NOT BE MADE WITHOUT O(n w rr ..:::` DETAIL C4.0/11 (TYP.) THE PRIOR WRITTEN APPROVAL OF ALL EQUIPMENT AND MATERIALS BY THE ENGINEER. J ' LOT rJ, KAGY T/� T/� .. .......... y 6� m OSSROADS SUBD 3. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL BURIED UTILITIES PRIOR TO THE BEGINNING "w PROPOSED BUILDING F5 0 OF CONSTRUCTION. < I `:.`.:I: NEW..1 ------1ST FLOOR SOUTH WING FFRELEV.491652 700 F 1 Y .; O YYYY k�' TOCKMAN BANK OF MONTANA 4. THE ENGINEER AND THE CITY OF BOZEMAN SHALL BE NOTIFIED AT LEAST 24 HOURS PRIOR TO REF BK 2127 G 968 BEGINNING CONSTRUCTION. ✓$0 I "' LI 122 APT. UNITS PROPOSED SIGN EED P ::t ENE T 5. TRENCH BACKFILL SHALL BE TYPE A FOR ALL AREAS TO BE PAVED. 9 , 9 I 4 6. SITE WORK TO BE PERFORMED ACCORDING TO THE RECOMMENDATIONS OUTLINED IN THE J "-" _ P 'F �l 'P "" m NT- ' � t�q "GEOTECHNICAL INVESTIGATION REPORT"PREPARED BY C&H ENGINEERING,DATED MARCH 2O12. OR�,1� - - 7. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ENSURING THAT THE PROJECT MEETS ALL OSHA \ SIDE _ '�.'?�. ! k9�0 �'. — REQUIREMENTS AND THAT THE SITE MEETS ALL APPLICABLE SAFETY REQUIREMENTS FOR HIS ' _ 50 EMPLOYEES AND ANY SITE INSPECTION WORK PERFORMED BY THE ENGINEER. •'w s"w NO PARK SIGN PROPOSED PROPERTY LINE s w,�—s w 8. PROPOSED GAS,ELECTRICAL AND COMMUNICATION LINE LOCATIONS ARE APPROXIMATE.FINAL EXISTING PROPERTY LINE FUTURE CURB LINE SERVICE LINE LOCATIONS ARE TO BE COORDINATED WITH SERVICE PROVIDER AT THE TIME OF APPLICATION FOR SERVICE. y CAGY BOULEVARD PROPOSED ARTERIAL STREET LIGHT(TYP.) ACKNOWLEDGEMENT OF ACCESS REQUIREMENTS UNDER FEDERAI AND STATE 18'BOULEVARD LONG KAGY SINGLE ARM,40'MOUNT HEIGHT DISCRIMINATION LAWS fARM 24301"9021 a INSTALL PER C.O.B.LIGHTING STANDARDS THIS ACKNOWLEDGES THAT THE FOLLOWING PROJECT WAS DESIGNED WITH FULL KNOWLEDGE THAT THE CITY OF BOZEMAN BUILDING DIVISION WILL NOT REVIEW FOR �_CIT1'-NMIT?r--EITY--LINT COMPLIANCE WITH, NOR IS RESPONSIBLE FOR ENFORCEMENT OF THE FEDERAL ITS---CITY--LiMIT�--CITY-NMITSI7Y--NMI AMERICANS WITH DISABILITIES ACT OF 1990,THE REHABILITATION ACT OF 1973,THE FAIR HOUSING AMENDMENTS ACT OF 1988,TITLE 49,CHAPTER 2,COMMONLY KNOWN —/] AS THE MONTANA HUMAN RIGHTS ACT,OR OTHER SIMILAR FEDERAL,STATE,OR LOCAL ¢ L LAWS THAT MANDATE ACCESSIBILITY TO COMMERCIAL CONSTRUCTION OR MULTIFAMILY vTI3 HOUSING. AFFORDABLE HOUSING Issue Date:101112019 NO AFFORDABLE HOUSING PER SECTION 17.02 OF THE BOZEMAN MUNICIPAL CODE IS PROPOSED FOR THIS DEVELOPMENT WATER RIGHTS(CASH-IN-LIEUI WATER RIGHTS HAVE BEEN PROVIDED BY THE UNDERLYING SUBDIVISION. PRIOR TO INITIATING CONSTRUCTION,AN EROSION AND SEDIMENT CONTROL PLAN ciso SHALL BE APPROVED BY THE CITY OF BOZEMAN. GROUND MOUNTED MECHANICAL EQUIPMENT OVERALL SITE NO GROUND MOUNTED MECHANICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO 01.0 UTILITIES,AIR EXCHANGE/CONDITIONING UNITS,TRANSFORMERS,OR METERS SHALL SCALE:1"=50' ENCROACH INTO THE REQUIRED YARD SETBACKS AND WILL BE PROPERTY SCREENED WITH AN OPAQUE SOLID WALL AND/OR ADEQUATE LANDSCAPE FEATURES. #190360