Loading...
HomeMy WebLinkAbout404 performance-windows-patiodoors-performancegrade-airinfiltration-soundtransmissionratings--100seriesPRODUCT PERFORMANCE Performance Standards The Window and Door Manufacturers Association (WDMA), The American Architectural Manufacturers Association (AAMA) and the Canadian Standards Association (CSA) have jointly released AAMA/WDMA/CSA 101/I.S.2/A440-11; North American Fenestration Standard/ Specification for Windows, Doors and Skylights, which calls for using “Performance Grade" as the new rating to describe products that comply to the standard. This new version dated “-11” has been adopted by the 2015 International Building Code (IBC) and the International Residential Code (IRC). Performance Grade ratings are being used to replace Design Pressure Ratings as the preferred method of measuring product performance throughout the window, door and skylight industry to define products that comply with all of the requirements of the 101/I.S.2/A440 standard. A product only achieves a “Performance Grade” or “PG” rating if that product complies with not only the structural loading requirement, but all other performance requirements such as air infiltration resistance, water penetration resistance, ease of operation and resistance to forced entry. A “Design Pressure Rating” or “DP” rating will now describe a product rating that has only been tested to structural loading and not air infiltration, water testing or other requirements for Performance Grade. Performance Classes This Standard/Specification defines requirements for four performance classes. The performance classes are designated R, LC, CW, and AW. This classification system provides for several levels of performance. Product selection is always based on the performance requirements of the particular project. Elements of Performance Grade (PG) Designations In order to qualify for a given performance grade (PG), test specimens need to pass all required performance tests for the following, in addition to all required auxiliary (durability) tests (not shown here) for the applicable product type and desired performance class: (a) Operating force (if applicable): minimum and maximum operating force vary by product type and performance class. (b) Air leakage resistance: tested in accordance with ASTM E283 at a test pressure of 1.57 PSF. The allowable air infiltration for R, LC & CW is 0.3 cubic feet per minute per square foot of frame (cfm/ft2). (c) Water penetration resistance: tested in accordance with ASTM E547 with the specified test pressure applied per AAMA/WDMA/CSA 101/I.S.2/A440-11. The test consists of four cycles. Each cycle consists of five minutes with pressure applied and one minute with the pressure released, during which the water spray is continuously applied. The water spray shall be uniformly applied at a constant rate of 5.0 U.S. gal/ft2 • hr. (d) Uniform load deflection test: tested in accordance with ASTM E330 for both positive and negative pressure (pressure defined by AAMA/WDMA/CSA 101/I.S.2/A440-11) with the load maintained for a period of 60 seconds. After loads are removed there shall be no more permanent deformation in excess of 0.4% of its span and no damage to the unit which would make it inoperable. Starting with the 2008 specification, design pressure (DP) will only represent the “uniform load deflection test.” (e) Uniform load structural test: tested in accordance with ASTM E330 for both positive and negative pressure (pressure defined by AAMA/WDMA/CSA 101/I.S.2/A440-11) with the load maintained for a period of 10 seconds. After loads are removed there shall be no damage to the unit which would make it inoperable. (f) Forced-entry resistance (if applicable): tested in accordance with ASTM F588 (Windows), F476 (Swinging Doors) and F842 (Sliding Doors) at a performance level 10 rating. Maximum Size Tested (MST) Test size is a factor in determining compliance with this Standard/Specification. Each product type and class has a defined minimum set of requirements. The minimum test size increases with each class (i.e. R, LC, CW or AW). Minimum Requirements The minimum requirements to obtain a Performance Grade (PG) are listed below: Product Performance Class MinimumPerformanceGrade (PG)(PSF) Minimum Design Pressure (DP) (PSF) Minimum Structural Test Pressure (STP) (PSF) Minimum Water Penetration Test Pressure (WTP)(PSF) Windows and Doors R 15 15 22.5 2.90 LC 25 25 37.5 3.75 CW 30 30 45.0 4.50 AW 40 40 60.0 6.00 • "Structural Test Pressure (STP)" is 150% of the Performance Grade (PG) for windows and doors. • "Water Penetration Test Pressure (WTP)" is 15% of the Performance Grade (PG). Optional Higher Performance Grades (PG) & Corresponding Test Pressures (PSF) PG20 PG25 PG30 PG35 PG40 PG45 PG50 PG55 PG60 WTP 3.00 3.75 4.50 5.25 6.00 6.75 7.50 8.25 9.00 DP 20 25 30 35 40 45 50 55 60 STP 30.0 37.5 45.0 52.5 60.0 67.5 75.0 82.5 90.0 Air 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 • Forced Entry Resistance (FER) is always a performance level 10 regardless of Performance Grade (PG). • Minimum and maximum Operating Force varies by product type. Hallmark Certification The Window and Door Manufacturers Association (WDMA) sponsored Hallmark Certification Program is designed to provide builders, architects, specifiers and consumers with an easily recognizable means of identifying products that have been manufactured in accordance with the appropriate WDMA and other referenced performance standards. Conformance is determined by periodic in-plant inspections by a third-party administrator. The inspections include auditing licensee quality control procedures and processes, and a review to confirm products are manufactured in accordance with the appropriate performance standards. Periodic testing of representative product constructions and components by a third-party testing laboratory is also required. When all of the program requirements are met, the licensee is authorized to use the WDMA Hallmark registered logo on the Certification Label as a means of identifying products. Products successfully obtaining Hallmark Certification will be labeled with a 3-part code, which includes performance class, performance grade and maximum size tested. Below is a sample certification label: (1) – Performance Class (2) – Performance Grade (3) – Size Tested (4) – Design Pressure In the example above, the performance class is LC, the performance grade (PG) is 40 PSF and the size tested is 71" x 71". What this means to the specifier is, based on the optional higher performance grade chart, the laboratory tested air infiltration was less than 0.3 cfm/ft2 (test pressure is always 1.57 PSF and the allowable airflow is 0.3 cfm/ft2), the product tested successfully resisted a laboratory water penetration test at a test pressure of 6.0 PSF (test pressure equals 15% of PG), the product tested successfully withstood a laboratory positive and negative structural test at a pressure of 60 PSF (test pressure equals 150% of performance grade) in both the positive and negative directions and the product tested passed the laboratory requirements for operational force and forced entry resistance. Based on this test, all products smaller in both width and height can be labeled with this product performance rating. Important Building codes prescribe Performance Grade (PG) based on a variety of criteria (i.e. windspeed zone, building height, etc.), therefore structural test pressures should not be used for code compliance. In the example above, a PG 40 performance grade rating, which passes a 40 PSF design pressure, should be used for determining code compliance, not the structural test pressure of 60 PSF. If you need further details about how Andersen® products perform to this standard, contact your Andersen supplier. If you need further information about the AAMA/WDMA/CSA 101/I.S.2/A440-11 standard or the Hallmark Certification Program please contact: WDMA, 330 N. Wabash Avenue Suite 2000 Chicago, IL 60611 Phone: 312-673-4828 Web: wdma.com Where designated, Andersen products are tested, certified and labeled to the requirements of the Hallmark Certification Program. Actual performance may vary based on variations in manufacturing, shipping, installation, environmental conditions and conditions of use. Hallmark Certified www.wdma.com Andersen Corporation 100 SERIES CASEMENT WINDOW Manufacturer Stipulates Conformance as indicated below CLASS LC(1) – PG40(2) – SIZE TESTED 71 X 71 in.(3) DP+40/-40(4) CLASS LC(1) – PG40(2) – SIZE TESTED 71 X 71 in.(3) DP+40/-40(4) STANDARD RATING AAMA/WDMA/CSA 101/I.S.2/A440-11 AAMA/WDMA/CSA 101/I.S.2/A440-08 2016 100 Series Product Guide - Revised 12/2017 Page 1 of 2 Performance Grade, Air Infiltration and Sound Transmission Ratings — 100 Series Windows and Patio Doors STANDARD GLASS STC UPGRADE GLASS Andersen® Product AAMA/WDMA/CSA 101/I.S.2/A440Performance Grade (PG) +/-Corresponding Design Pressure (DP) Sound TransmissionClass (STC) Outdoor/Indoor Transmission Class (OITC) Sound TransmissionClass (STC) Outdoor/Indoor Transmission Class (OITC)Air InfiltrationCFM/FT2 Casement Windows Single & Twin (venting/stationary)Class LC-PG40 Size Tested 71.5" x 71.5"+40/-40 30 25 33 28 < 0.2 Picture with Flanking Casements Class LC-PG40 Size Tested 143.5" x 71.5"+40/-40 ----< 0.2 Awning Windows Single & Twin (venting/stationary)Class LC-PG40 Size Tested 47.5" x 95.5"+40/-40 30 25 33 28 < 0.2 Picture over Awning Class LC-PG40 Size Tested 47.5" x 95.5"+40/-40 ----< 0.2 Single-Hung Windows Arch Single-Hung Class LC-PG30 Size Tested 41.5" x 95.0"+30/-30 ----< 0.2 Single-Hung Class LC-PG30 Size Tested 47.5" x 89.5"+30/-30 25 21 32 26 < 0.2 Twin & Triple Single-Hung Class LC-PG30 Size Tested 143.5" x 71.5"+30/-30 ----< 0.2 Transom over Single-Hung Class LC-PG30 Size Tested 47.5" x 95.5"+30/-30 ----< 0.2 Picture with Flanking Single-Hungs Class LC-PG30 Size Tested 143.5" x 71.5"+30/-30 ----< 0.2 Gliding Windows Gliding - XO/OX (active-stationary or stationary-active)Class LC-PG30 Size Tested 71.5" x 71.5"+30/-30 25 21 32 27 < 0.2 Picture over Gliding - XO/OX Class LC-PG30 Size Tested 143.5" x 71.5"+30/-30 ----< 0.2 Gliding - XOX (active-stationary-active)Class LC-PG30 Size Tested 107.5" x 83.5"+30/-30 ----< 0.2 Picture over Gliding - XOX Class LC-PG30 Size Tested 59.5" x 83.5"+30/-30 ----< 0.2 Picture, Transom & Specialty Windows Class LC-PG40 Size Tested 95.5" x 84.3"+40/-40 26 21 31 26 < 0.2 Gliding Patio Doors Class LC-PG30 Size Tested 95.3" x 95.5"+30/-30 28 23 29 26 < 0.2 Patio Door Transoms Class LC-PG30 Size Tested 95.3" x 23.3"+30/-30 29 24 31 26 < 0.2 Patio Door Sidelights Class LC-PG30 Size Tested 47.3" x 95.3"+30/-30 29 24 31 26 < 0.2 For current performance information please visit andersenwindows.com. • "Performance Grade (PG)" ratings may vary from tested performance rating for larger or smaller units of a particular type.• "Sound Transmission Class (STC)" & "Outdoor/Indoor Transmission Class (OITC)" ratings are for individual units based on independent tests and represent entire unit.• This data is accurate as of August 2015. Due to ongoing product changes, updated test results, or new industry standards, this data may change over time. • Where designated, Andersen products are certified and labeled to the requirements of the Hallmark Certification Program. Actual performance may vary based on variations in manufacturing, shipping, installation, environmental conditions and conditions of use.• Contact your Andersen supplier for more information. • "Low-E SmartSun" is an Andersen trademark for a type of "Low-E" glass. • Based on NFRC testing/simulation conditions using Windows v7.3.4.0 and NFRC validated spectral data. 0°F outside temperature, 70°F inside temperature and a 15 mph wind. 1) Visible Transmittance (VT) measures how much light comes through the glass. The higher the value, from 0 to 1, the more daylight the glass lets in. Visible Transmittance is measured over the 380 to 760 nanometer portion of the solar spectrum. 2) Shading Coefficient defines the amount of heat gain through the glass compared to a single lite of clear 1/8" (3 mm) glass. 3) Solar Heat Gain Coefficient (SHGC) defines the fraction of solar radiation admitted through the glass both directly transmitted and absorbed and subsequently released inward. The lower the value, the less heat is transmitted through the glass. 4) Relative Heat Gain is the amount of heat gain through a glazing incorporating U-Factor and Solar Heat Gain Coefficient. 5) Transmission Ultra-Violet Energy (TUV). The transmission of short-wave energy in the 300-380 nanometer portion of the solar spectrum. The energy can cause fabric fading. 6) Transmission Damage Function (TDW). The transmission of UV and visible light energy in the 300-600 nanometer portion of the solar spectrum. The value includes both the UV and visible light energy that can cause fabric fading. This rating has also been referred to as the Krochmann Damage Function. This rating better predicts fading potential than UV transmission alone. The lower the Damage Function rating, the less transmission of short-wave energy through the glass that can potentially cause fabric fading. Fabric type is also a key component of fading potential. 7) Percent relative humidity before condensation occurs at the center of glass, taken using center of glass temperature. 8) Inside glass surface temperatures are taken at the center of glass. • This data is accurate as of August 2015. Due to ongoing product changes, updated test results, or new industry standards, this data may change over time. Contact your Andersen supplier for current performance information or upgrade options. • Contact your Andersen supplier or visit andersenwindows.com/nfrc for center of glass performance data on windows with laminated glass, patterned glass, tempered glass and products ordered with capillary breather tubes. Center of Glass Performance Data — 100 Series Windows and Patio Doors For current performance information please visit andersenwindows.com. Andersen® Product and Glass Type Visible Light1 SC2 SHGC3 RHG4 Fading %RH @ center7 IGST8Tuv5Tdw6 High-Performance Low-E Glass Casement, Awning, Single-Hung and Gliding Windows 73%0.48 0.42 98.7 17%34%60%55.4 Picture, Transom & Specialty Windows 72%0.47 0.41 97.5 16%33%60%55.3 Gliding Patio Doors 72%0.47 0.41 97.5 16%33%60%55.3 Patio Door Sidelights & Transoms 72%0.47 0.41 97.5 16%33%60%55.3 High-Performance Low-E SmartSun™ Glass Casement, Awning, Single-Hung and Gliding Windows 66%0.31 0.27 65.3 5%21%61%55.9 Picture, Transom & Specialty Windows 65%0.31 0.27 64.9 5%21%61%55.7 Gliding Patio Doors 65%0.31 0.27 64.9 5%21%61%55.7 Patio Door Sidelights & Transoms 65%0.31 0.27 64.9 5%21%61%55.7 Dual-Pane Glass Casement, Awning, Single-Hung and Gliding Windows 83%0.91 0.79 189 63%65%39%43.6 Picture, Transom & Specialty Windows 82%0.89 0.78 186 58%61%39%43.6 Gliding Patio Doors 82%0.89 0.78 186 58%61%39%43.6 Patio Door Sidelights & Transoms 82%0.89 0.78 186 58%61%39%43.6 2016 100 Series Product Guide - Revised 12/2017 Page 2 of 2