HomeMy WebLinkAbout404 Door Fire RatingsLISTING INFORMATION OF Therma Tru 20 Min (with hose) Fiberglass Fire Door PP Model
20PPFFD
SPEC ID: 25358
Therma Tru Corporation
1750 Indian Wood Circle
Maumee, OH 43537
This report is for the exclusive use of Intertek’s Client and is provided pursuant to the agreement between Intertek and its Client.
Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party,
other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only
the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one
of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The
observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material,
product, or service is or has ever been under an Intertek certification program.
Report prepared for: Jesse Peterson (Intertek) on 5/20/2011 3:57:48 PM
Therma Tru Corporation | 25358 | Rev: May 16 2011 11:02AM | Uncontrolled Copy | DRAFT - NOT APPROVED Page 1 of 3
Fiberglass Reinforced Faced (Proprietary Core) (Simulated Panel Type or Flush) Swinging Door for installation in
up to 20 minute locations (with or without hose stream-see table below). For use in any "Category C - Standard"
frames. These doors may also be installed in frames listed in "Category C - Proprietary" in accordance with the
frame manufacturer's individual listing. A fire rated compression weather strip is required.
Limitations
Cylindrical/Mortise/Deadbolt/Latches with maximum 2-3/4" backset/Card Reader/Surface Mounted Vertical
Rod Fire Exit Devices/Rim-Type Fire Exit Devices/Viewers/Protection Plates/Surface Mounted
Closers/Surface or Kerf Mounted Door Bottom/ Arch Top and Round Top Door Configurations.
Maximum Size of Openings
Single Swing (with hose stream) 3'0" wide x 6'8" high
Standard and Double Egress Pairs - Not Allowed
Testing Standard
UL-10C (Positive Pressure) (2009)
NFPA 252 (2008)
CAN4 S104 (1985)
All assemblies are identified by a label or marking bearing the wording, "Listed (Product)", a time interval,
temperature rise (if applicable), a serial number and the WHI Certification Mark.
(Unless otherwise specified, all Fire Doors have a nominal thickness of 1-3/4".)
Attribute Value
CSI Code 08 10 00 Doors and Frames
CSI Code 08 15 00 Plastic Doors
Fire Resistance 20 Min w/Hose Stream PP Cat A Door
Swing Single Swing
Listed or Inspected LISTED
Report Number 100354358MID-001
Criteria CAN4 S104 (1985)
Criteria NFPA 252 (2008)
Criteria UL 10(c) (2009)
Intertek Services Certification
Listing Section CATEGORY A - DOORS - NO ADDITIONAL EDGE-
SEALING SYSTEM REQUIRED
Report prepared for: Jesse Peterson (Intertek) on 5/20/2011 3:57:48 PM
Therma Tru Corporation | 25358 | Rev: May 16 2011 11:02AM | Uncontrolled Copy | DRAFT - NOT APPROVED Page 2 of 3
Report prepared for: Jesse Peterson (Intertek) on 5/20/2011 3:57:48 PM