HomeMy WebLinkAbout005 404 ElectricalS
e
c
o
n
d
F
l
o
o
r
S
y
s
t
e
m
c
D
a
t
e
:
mobile #:
phone #:
Project No.
D
r
a
w
n
b
y
:
D
a
t
e
:
Scale:
GENERAL CONTRACTOR:
R
e
v
i
s
e
d
b
y
:
D
r
a
f
t
i
n
g
&
D
e
s
i
g
n
,
I
n
c
.
B19-0109-1-3McLay Project
330 AND 404 NO. ROUSE
BOZEMAN, MONTANA
CHRIS MCLAY 608-774-2678
Tracts 1 & 2
D
.
J
o
h
n
s
t
o
n
2
8
J
a
n
1
9
D
.
J
o
h
n
s
t
o
n
0
4
F
e
b
1
9
T
h
e
s
e
d
r
a
w
i
n
g
s
a
r
e
l
i
c
e
n
s
e
d
f
o
r
O
N
E
U
S
E
O
N
L
Y
.
D
.
J
o
h
n
s
t
o
n
1
6
J
a
n
1
9
D
.
J
o
h
n
s
t
o
n
2
5
J
a
n
1
9
D
.
J
o
h
n
s
t
o
n
0
8
M
a
r
1
9
IMPACT
DRAFTING & DESIGN, inc.
www.impactdrafting.com
2
0
1
9
Brentwood Professional Center
1195 Stoneridge Dr., Suite 3D
Bozeman, MT. 59718
406-522-5382
A
l
l
r
i
g
h
t
s
r
e
s
e
r
v
e
d
.
A
l
l
d
e
s
i
g
n
s
,
d
r
a
w
i
n
g
s
,
i
d
e
a
s
,
a
n
d
w
r
i
t
t
e
n
m
a
t
e
r
i
a
l
c
o
n
t
a
i
n
e
d
o
r
d
e
s
c
r
i
b
e
d
h
e
r
e
i
n
a
r
e
t
h
e
s
o
l
e
p
r
o
p
e
r
t
y
o
f
I
M
P
A
C
T
D
r
a
f
t
i
n
g
&
D
e
s
i
g
n
I
n
c
.
a
n
d
a
s
s
u
c
h
m
a
y
n
o
t
b
e
a
l
t
e
r
e
d
,
d
u
p
l
i
c
a
t
e
d
,
u
s
e
d
o
r
d
i
s
c
l
o
s
e
d
w
i
t
h
o
u
t
w
r
i
t
t
e
n
c
o
n
s
e
n
t
f
r
o
m
I
M
P
A
C
T
D
r
a
f
t
i
n
g
&
D
e
s
i
g
n
I
n
c
.
scale is correct if
printed on D-Size paper
by IMPACT Drafting
Note: IMPACT Drafting & Design Inc. is not responsible for engineering or
construction. Individual contractors are responsible for meeting codes.
I
M
P
A
C
T
5
1
6
1/4" = 1'
F
l
o
o
r
P
l
a
n
S
e
c
o
n
d
F
l
o
o
r
1
/
8
"
=
1
'
s
c
a
l
e
:
1
/
4
"
=
1
'
F
l
o
o
r
F
r
a
m
i
n
g
N
o
t
e
s
:
-
d
o
u
b
l
e
j
o
i
s
t
s
o
r
b
e
a
m
u
n
d
e
r
p
a
r
a
l
l
e
l
b
e
a
r
i
n
g
w
a
l
l
s
-
l
a
t
e
r
a
l
r
e
s
t
r
a
i
n
t
a
t
a
l
l
i
n
t
e
r
m
e
d
i
a
t
e
s
u
p
p
o
r
t
l
o
c
a
t
i
o
n
s
Second Floor Electric
a
l
scale: 1/4" = 1'
S
e
c
o
n
d
F
l
o
o
r
E
l
e
c
t
r
i
c
a
l
R
e
v
i
s
e
d
b
y
:
D
a
t
e
:
A
d
d
i
t
i
o
n
a
l
R
e
v
i
s
i
o
n
s
D
.
J
o
h
n
s
t
o
n
2
8
J
u
n
1
9
D
.
J
o
h
n
s
t
o
n
0
3
A
p
r
1
9
D
.
J
o
h
n
s
t
o
n
1
5
J
u
l
1
9
-
-
-
-
-
-
-
-
General Electrical Notes- Smoke detectors to beinterconnected- All Smoke Detectors outsideSleeping Rooms and at the top andbottom of stairs must also be acombination carbon monoxidedetector (R315)- Electrical outlets in kitchen, garageand laundry to be 48" above floorlevel- All interior outlets to be AFCI &tamper resistant- All interior recessed lights to be ondimmer switches- All Exterior Lights to be dark-skycompliant- Electrical plans may need to bedeviated from by electrician to meetbuilding specific needs either bydesign or code, however thosedeviations must be discussed withIMPACT Drafting, Builder, or Clientprior to being made. No deviationsmay violate electrical codes.- IRC Section 303.4 - Where the airinfiltration rate of a dwelling unit isless than 5 air changes per hourwhen tested with a blower door at apressure of 0.2 inch w.c. (50Pa) inaccordance with SectionN1102.4.1.2, the dwelling unit shallbe provide with whole-houseventilation in accordance withSection M1507.3- Per NEC 210.11(C)3 bathroomcircutting shall either be: a) a 20amp dedicated circuit for eachbathroom or b) at least one 20 AMPcircuit supplying only bathroomoutlets = arc fault circuit interrupted outlet= smoke detector= wall mounted doorbell = garage door opener = ceiling mounted fan fixture w/ light = duplex outlet, 110 v.ELECTRICAL LEGEND = 220 outlet= switch = ground fault interrupting outlet (GFCI)= ceiling mounted light fixture = 3-way switch= 4-way switch= dimmer switch= wall mounted light fixture = waterproof outlet (GFCI)= switched duplex outlet, 110 v.= in floor duplex outlet, 110 v.= phone / satellite jack (RJ11)= thermostat = flush, wall mounted, stair wash= ceiling mounted fan fixture= computer data port (RJ45)= exhaust fan w/ light = troffer light fixture (led/fluorescent/etc.)= stereo / sound system jack = television cable jack= doorbell button = garage door button or keypad = track lighting= over / under cabinet lighting= carbon monoxide & smoke detector = recessed, ceiling mounted light fixture(led recommended)