Loading...
HomeMy WebLinkAbout04 Stadium Center Landscape Plan 07-08-2019 Plants Materials r I E I � EXISTING 4"0 SANITARY , Helena I _ Maplele 2 5-3o' SEWER SERVICE LOT welded Steel Ed in g Welded 5teelEdging N89 41 24•E EXISTING BUILDING Ncer plats ides 'Helena' Z02IS. Plantino ize:_. EV=4918.73 116 61' (A EXTENTS ASHOWN) R x 7 Lawn LawnFIFE=4919.55 -T- W-1- —1 0_11r� MISTING OTABLE l o Fine Line®gjuckthorn 4-6' Mack E)asalt Chip ERVICE 6 ()$ Rhamus Frongula 'Ron Williams' E)ed Material Plantingsize•.Sgal. 10 eU.y s. DING * x 12 OUTER 3: w )W N) M C Landscape Irrigation Plumb-Qut LOT 11 o M Ozo ` 69 c� PROPOSED FINISH FLOOR ELEV=4919.10 +V' 0 0 o Z ^�. rn C F)lue Fescue 6-10- 0 II 49A9 0 _ Festaca g/auca 'Elijah Blue' ^ u IJ I II black basalt Chir bed Material �: Plano Drought gal. 116.61' S890 41'24"W Karl Forester}teed Grass V tall,2'wide ��.. Calamagrostis x acutiFlora 'Karl Forester' t Planting5ize:i gallon STADIUM CENTER SUB. Drought Tolerant O} COMMON AREA x57 ! 4onduit c� i� �5 Cc� eFlan Scale: 1/8" = t ' Per-formance Poit�ts01 June 9, 20 i 9 Tabulation of performance points earned by the plan per section 38.26.060 BMC Section 13.1.a 3 points Con ui Irrigation Notes Estimated Water(1se Main line and valve boxes w Note:Estimations based on the hottest day of the year Section B.1.b 3 points Landscape Irrigation FI-6-put r_OT 11 ��—^+• All trees and shrubs are to be watered via high efficiancy drip irrigation emmitters. Drip \ PROPOSED FINISH FLOOR ELEV=4919.10 N tube is to be subsurface and secured to the ground with landscape staples. Trees: 3 gallons/tree/day x 7 trees = 21 gallons Section B.2 10 points Controller Lawn area is to be watered utilizing a automatic underground irrigation system consisting Shrubs: .5 gallon/shrub/day x 12 shrubs = 6 gallons of high efficiency MP Rotators layed out in a fashion to provide turf with adequate water Section B.4 2 points and minimal to no runoff. Grasses:.25 gallon/grass/day x 116 grasses=29 gallons 409 0 Bluegrass Lawn: .2"Iday x1,300s.f =20gallons �,kE-1,C6r.�dM—W �L Designed 6y: Scott Samson TOTAL=76GALLONS/DAY Total: 18 points — # L fond "�•�, „ i jao F.(406)581-3986 1410 LoYan Trident Rd. Owner: Rtse & Grind Points Needed: 15 points ,.81 Landsca e Designer Three Forks,MT J 1958 Stadium ViewDrive 58741'24W Certifie�Flant professional 59752 Bozeman,MT 5971 8 � *Zone 1 MP Rotator 1000's zone 1 MP Rotator 1000's • Zone 1 MP Rotator 1000's L 1 •zone 2 MP Rotator I 000's 9 Zone i MP Rotator 1 000's Irri�atioc� Flan ' HOME RANG. LANDSCAP�.5 Drip P