Loading...
HomeMy WebLinkAboutB. 2019-03-12 Sundance Park Landscape Plan SetGALLOWAY STREETEQUESTRIAN LANECABALLO AVENUE CASPIAN AVENUE LAWNLAWNTRAIL CENTER LINE,TYP.SIDEWALKSIDEWALKCURB & GUTTERCURB &GUTTERCURB & GUTTERPHASE 2: BENCH, TYP.PAVILIONLAWNLAWNLAWNLAWNLAWNLAWNLAWNLAWNLAWNPROPOSED SIDEWALKBY OTHERS, SEE CIVILPLANSPROPOSED SIDEWALKBY OTHERS, SEE CIVILPLANSL1.0COVER SHEETL1.1IRRIGATION PLANL1.2IRRIGATION DETAILSL2.1HARDSCAPE LAYOUT PLANL3.1PLANTING PLAN & PHASINGL3.2PLANTING DETAILSLANDSCAPE SHEET INDEXDEVELOPMENT DATAADDRESS: 3605 BAXTER LANE BOZEMAN, MT 59718LEGAL DESCRIPTION: SUNDANCE MINOR SUBDIVISION, PH A, SEC 32, T1S,R5E, LOT 2PROPOSED USE:MIXED-USE DEVELOPMENTZONING:B-2PHASE A TOTAL SITE:9.189 ACRESDEDICATED PARKLAND DATAPARKLAND REQUIRED: 3.31 AC.12 DWELLING UNITS/AC. X 0.03 AC./UNIT = 0.36 AC. OF PARKLAND/ACRE0.36 AC. PARKLAND X 9.189 AC. = 3.31 AC. PARKLAND REQUIREDPARKLAND PROVIDED:2.83 AC.3.31 AC. REQUIRED - 2.83 AC. PROVIDED = 0.48 AC. PARKLAND REMAININGREMAINING PARKLAND:0.48 AC.REMAINING PARKLAND TO BE PROVIDED THROUGH PHASE 2 PARK AMENITIES.SEE PARK MASTER PLAN DOCUMENT.PEDESTRIAN ACCESS:PEDESTRIANS TO CROSS CASPIAN AVE, EQUESTRIAN LANE, CABALLO AVENUEAND GALLOWAY STREETS AT DESIGNATED CROSSWALKS LOCATED MID-BLOCKON GALLOWAY STREET AND AT INTERSECTIONS. PEDESTRIANS CAN CONNECTFROM SUNDANCE PARK TO EXISTING PARKLAND TO THE NORTH EAST ALONGGALLOWAY STREET SIDEWALKS.OWNER / DEVELOPERBAXTER MEADOWS LAND PARTNERS, LLCC/O 1181 WEST DICKERSON STE 17BOZEMAN, MT 59715406-539-0397LANDSCAPE ARCHITECTWGM GROUP109 E MAIN ST STE BBOZEMAN, MT 59715406-728-4611CIVIL ENGINEERTD&H ENGINEERING234 EAST BABCOCK ST STE 3BOZEMAN, MT 59715406-586-0277CONTACT INFORMATION S TA T E OF MONTANA LANDSCAPE ARCH ITECT LESSA R.RACOW274 LICENSE D WGMGROUPWWW.WGMGROUP.COMNOT FORCONSTRUCTIONFOR REVIEWSUNDANCE PARK SUNDANCE MINOR SUBDIVISION 3605 BAXTER LANE, BOZEMAN, MT 59718MARCH 12, 2019L1.0PRELIMINARYPLOTTED:SAVED:3/14/193/14/19PLANTING PLAN1PLANN0SCALE - FEET303060PARKLOCATIONPHASE APHASE BGALLOWAY STEQUESTRIAN LNCABALLO AVE CASPIAN AVE DAVIS LNBAXTER LNEXISTINGPARKEXISTINGAPARTMENTSNTSVICINITY MAP2PLANNPHASE C GALLOWAY STREETEQUESTRIAN LANECABALLO AVENUE CASPIAN AVENUEPOINT OF CONNECTIONPOC IS PROPOSED WELL. TEST WELL TO ASSURENECESSARY PRESSURE FOR THE SYSTEM ASDESIGNED. TAP LINE AND SET WATER METER. IFNECESSARY, IMPLEMENT A PRESSURE REDUCINGVALVE. THIS SYSTEM IS DESIGNED FOR A 1-1/2"WATER METER WITH 35 GPM DESIGN CAPACITYAND MAXIMUM WORKING PRESSURE OF 45 PSI.C15' TYP66666666666666666666666666666666 66666666666661.51.531.566STUB FOR FUTUREPHASE 2 DRIPLINESTUB FOR FUTUREPHASE 2 DRIPLINESTUB FOR FUTUREPH2 DRIPLINESTUB FOR FUTUREPHASE 2 DRIPLINE28.131.5"1151.5"2241.5"329.621.5"4N/A1"527.201.5"817.961.5"791"619.51.5"9241.5"10131.5"11241.5"12241.5"1325.381.5"14N/A1"1528.031.5"1622.911.5"1721.301.5"18241.5"19241.5"2023.981.5"21111"22N/A1"23241.5"24241.5"25241.5"2616.921.5"28241.5"29241.5"30N/A1"3123.981.5"3230.682"27STUB FOR FUTUREPHASE 2 DRIPLINESTUB FOR FUTUREPHASE 2 DRIPLINE1.25"1"1.25"1.25"1.25"1.5"1"1"1.25"1"1.25"1.25"1.25"1"1"1.5"1.25"1.25"1.25"1.25"1"1"1.25"1.25"1"1.5"1"1"1.25"1.25"1"1"1"1"1"1.25"1"1"1"1"1.25"1"1"1"1.25"1"1"1"1"1"1"1.25"1.25"1"1"1"1.25"1"1"1.25"1.25"1"STUB FOR FUTUREPH2 TREESTUB FOR FUTUREPH2 TREESTUB FOR FUTUREPH2 TREESTUB FOR FUTUREPH2 TREEZONE 11, INSTALLVALVE & PIPE,STUB FOR PH2TREESEQUIPMENTIRRIGATION NOTES1.IRRIGATION PLAN SHOWN IS FOR PHASE 1 & 2 PLANTINGS. INSTALL AND STUB ALL PIPE FORPHASE 2.2.CONTRACTOR RESPONSIBLE FOR PROVIDING IRRIGATION AS-BUILTS TO OWNER AT COMPLETIONOF INSTALLATION.3.CONTRACTOR RESPONSIBLE TO INFORM LANDSCAPE ARCHITECT OF ANY DISCREPANCIES ORCHANGES NEEDED TO THE IRRIGATION DESIGN. IF CONTRACTOR MAKES CHANGES TO THEIRRIGATION DESIGN WITHOUT NOTIFYING THE LANDSCAPE ARCHITECT, CONTRACTOR ASSUMESFULL RESPONSIBILITY OF THE IRRIGATION SYSTEM DESIGN AND FUNCTIONALITY.4.OWNER'S REPRESENTATIVE TO SUBMIT TO THE CITY OF BOZEMAN A CERTIFIED WELL LOGSHOWING DEPTH OF WELL, GPM, PUMP TYPE AND SIZE, VOLTAGE AND WATER RIGHTS.5.CONTRACTOR TO VERIFY STATIC PRESSURE IN THE FIELD PRIOR TO BIDDING AND CONSTRUCTION.IN THE EVENT OF A DISCREPANCY, CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT INWRITING OF ANY CHANGES NECESSARY TO PROVIDE THE REQUIRED OPERATIONAL PRESSUREAND FLOW. IF NOTIFICATION IS NOT RECEIVED, CONTRACTOR ASSUMES FULL RESPONSIBILITY FORSYSTEM OPERABILITY.6.PROVIDE PRESSURE REDUCING VALVE IF PRESSURE EXCEEDS 80 PSI. REDUCE TO 60PSI STATICPRESSURE.7.INSTALLED SYSTEM TO BE FULLY WINTERIZEABLE. CONTRACTOR TO PROVIDE OWNER'SREPRESENTATIVE WITH WINTERIZATION PLAN.8.CONTRACTOR SHALL COORDINATE PLANTING WITH IRRIGATION INSTALLATION.9.THE CONTRACTOR SHALL INSPECT THE SITE AND VERIFY CONDITIONS AND DIMENSIONS PRIOR TOCONSTRUCTION.10.IRRIGATION PLANS ARE SCHEMATIC REPRESENTATIONS ONLY. PLACE LINES IN A COMMONTRENCH WHENEVER POSSIBLE. FIELD ADJUST LINES TO AVOID CONFLICT WITH UTILITIES.11.IRRIGATION IS COORDINATED WITH THE PLANTING PLAN AND SITE IMPROVEMENTS AND ISDESIGNED WITH RECTANGULAR SPACING GIVING HEAD TO HEAD COVERAGE. COORDINATEIRRIGATION HEAD LAYOUT WITH NEW PLANT MATERIALS, LOCATE SPRAY HEADS 30" FROM BASEOF TREE. DO NOT ALTER HEAD LOCATION, PIPE LAYOUT, OR VALVE LOCATION WITHOUT WRITTENAPPROVAL FROM THE CONSTRUCTION MANAGER. NOTIFY OWNER'S REPRESENTATIVE IFDISCREPANCIES OCCUR BETWEEN THE PLANS AND FIELD CONDITIONS.12.ALL COMPONENTS OF IRRIGATION SYSTEM SHALL BE INSTALLED AND PROPERLY ADJUSTED TOPROVIDE ADEQUATE HEAD TO HEAD COVERAGE AND MINIMIZATION OF OVER SPRAY ONTO WALKS,BUILDINGS, PARKING AREAS, ETC.13.ALL PIPE SIZES INDICATED ARE MINIMUMS. CONTRACTOR MAY NOT DECREASE PIPE SIZE.LARGER PIPE SIZES MAY BE USED AT NO ADDITIONAL COST TO OWNER. PIPE SIZES INCREASE INSIZE DOWNSTREAM OF NEXT SPRAY HEAD, AS SHOWN.14.INSTALL ALL IRRIGATION PIPE AND CONTROL WIRES IN MINIMUM 4" PVC SLEEVE BELOW ALL PAVEDSURFACES UNLESS OTHERWISE INDICATED ON THE PLANS. INSTALL SLEEVES PRIOR TOPLACEMENT OF PAVEMENTS AND PAVEMENT SUB-BASE. WHERE PAVEMENT EXISTS BORE ANDPLACE SLEEVES.15.COORDINATE IRRIGATION POINTS OF CONNECTION AND LOCATION OF AUTOMATIC CONTROL VALVESWITH PROJECT MANAGER. COORDINATE ALL WORK WITH OTHER TRADES, I.E. ELECTRICAL,MASONRY, ETC.16.CONTRACTOR TO PROGRAM AUTOMATIC CONTROLLER TO ALLOW FOR THE EQUIVALENT OF 1" OFWATER PER WEEK, FROM EITHER RAIN OR IRRIGATION, FOR TREES AND SHRUBS BEDS AND 0.75"PER WEEK FOR LAWN AREAS. ASSURE 6" DEPTH OF WET SOIL FOLLOWING EACH WATERING. TWODEEP WATERINGS PER WEEK ARE RECOMMENDED FOR LAWN AREAS. ADJUST WATERING NEEDSPER SITE AND PLANTING NEEDS FOR BEST PLANT HEALTH TO PREVENT WILT. WHEN POSSIBLE,THE IRRIGATION SYSTEM SHALL RUN BETWEEN THE HOURS OF 6AM-10AM AND/OR 4PM AND6PM.17.ALL PIPES SHALL BE TRENCHED. PROVIDE POSITIVE DRAINAGE OF MAINLINE. PLACE MANUALDRAIN AT LOW POINTS IN MAINLINE. IDENTIFY LOCATIONS ON AS-BUILTS.18.USE 45-DEG. ELLS INSTEAD OF 90-DEG. ELLS ON ALL MAINLINES 2-1/2" AND LARGER. INSTALLCMU THRUST BLOCKS AT ALL MAINLINE CHANGES IN DIRECTION.19.CONTRACTOR TO INSTALL CONTROLLER AND ACCESSORIES AS REQUIRED. CONTRACTOR TOFURNISH CONTROL WIRES FROM VALVES TO CONTROLLER. CONTRACTOR SHALL BE RESPONSIBLEFOR COORDINATING 110 VOLT SERVICE FROM EXISTING ELECTRICAL SERVICE AND CONNECTION TOCONTROLLER SERVICE.20.INSTALL ONE (1) ADDITIONAL RED CONTROL WIRE AND ONE (1) ADDITIONAL WHITE CONTROL WIREFROM CONTROLLER TO END OF MAINLINE.IRRIGATION LEGENDPOINT OF CONNECTIONBACKFLOW PREVENTERFEBCO MODEL LF767FR, 2" OR APPROVED EQUALINSTALL 12" ABOVE GROUND IN MANF. APPROVEDHOUSING INSULATE PER MANUFACTURERRECOMMENDATIONSBALL VALVENIBCO T-560 OR APPROVED EQUALCLOSED IN WINTER AND FOR MAINTENANCESLEEVING2X PIPE DIAMETER AS SHOWN (MIN. 4"DIA) SCH. 40PVC PIPEMAINLINE2" SCH. 40 PVC PIPECONTROLLERHUNTER I-CORE (IC-600-PP) CONTROLLER WITHPLASTIC PEDESTAL MOUNT, DUAL DECODER(DUAL49M), AND SOLAR SYNC WIRELESS SENSOR(WSS WITH MOUNTING ARM). VERIFY ELECTRICALCONNECTIONS ON SITE. LOCATION TO BE APPROVEDBY OWNER.CLATERAL LINESIZE AS SHOWN,SCH. 40 PVC PIPEREMOTE CONTROL VALVEHUNTER PGV OR APPROVED EQUAL, SIZE AS SHOWN.QUICK COUPLERHUNTER HQ-44LRC, OR APPROVED EQUAL. INSTALL IN6" VALVE BOXDETAILREF.HUNTER SPRINKLER/ROTOR HEADSMP SIDE STRIP - ADJUSTABLE 25%455'X30'0.47MP LEFT/RIGHT STRIP - ADJUSTABLE 25%CONTRACTOR TO ADJUST ALL ROTORS/SPRINKLER HEAD ARC ANDRADIUS TO FIT SITE. DO NOT ALLOW OVERSPRAY ON HARDSCAPESURFACES.PSIRADIUSGPMPSIGPMWIDTH XLENGTH408-14'0.214531'1.5455'X15'0.23RZWS-18-25-CV - ROOT ZONE WATERINGSYSTEM. SYMBOL INDICATES TWO(2) PER TREE. INSTALL FOR PHASE 1TREES, PROVIDE VALVES, PIPE, ANDSTUB FOR PHASE 2 TREES AS SHOWN. SEE PLANTING PLAN.453" DIA X 18"0.5(2x0.25)PRESSURE REDUCING VALVE(IF 80 PSI OR GREATER)VALVE NUMBERGALLONS PER MINUTEPIPE SIZEVALVE ZONE KEYSTOP AND WASTE VALVEWATTS SERIES B6300/B6301 , OR APPROVED EQUAL4538'3.04543'6.0WELL LOCATION63301.5"11L1.23L1.24L1.22L1.27L1.210L1.26L1.29L1.211L1.2MP1000-90 - ADJUSTABLE ARC 90-210I-20-06-PRB-1.5 - ADJST. ARC 50-360I-20-04-PRB-3.0 - ADJST. ARC 50-360I-20-04-PRB-6.0 - ADJST. ARC 50-360MP1000-180 - ADJUSTABLE ARC 90-210MP1000-360 - ADJUSTABLE ARC 45-100408-14'0.42408-14'0.84DRIPLINE AREAAREA OF FUTURE PHASE 2 DRIP LINE. PROVIDE VALVEAND RUN PIPE TO GARDEN BED, STUB FOR DRIPLINE. HUNTER ICZ-101-LF DRIP CONTROL ZONE KIT.PLD-06-12 DRIPLINE TUBING 0.6 GPH EMITTERS WITHCHECK VALVE AT 12" ON CENTER EMITTER SPACING -ALL TUBING SHALL BE INSTALLED ON GRADE W/ 6" WIRESTAKES FOUR (4) FEET ON CENTER; VERIFY THE LAYOUT AND 12" ON CENTER SPACING IN THE FIELD PRIOR TO STARTING WORK. INSTALL ON GRADE DRIPIRRIGATION SYSTEM PER MAN\F.'S SPECIFICATIONS.1.5MP2000-90 - ADJUSTABLE ARC 90-210MP2000-180 - ADJUSTABLE ARC 45-1004013-20'0.434013-19'0.77MP2000-360 - ADJUSTABLE ARC 45-1004013-19'1.48MP3000-90 - ADJUSTABLE ARC 90-210MP3000-180 - ADJUSTABLE ARC 45-1004022-30'0.864022-30'1.82MP3000-360 - ADJUSTABLE ARC 45-1004022-30'3.64408-14'0.39MP CORNER - ADJUSTABLE ARC 45-105°WGMGROUPWWW.WGMGROUP.COMNOT FORCONSTRUCTIONFOR REVIEWSUNDANCE PARK SUNDANCE MINOR SUBDIVISION 3605 BAXTER LANE, BOZEMAN, MT 59718MARCH 12, 2019L1.1PRELIMINARYPLOTTED:SAVED:3/14/193/14/19PIPE SIZING CHARTPVC SCHEDULE 4034" 0-8 GPM1"8-13 GPM1 14"13-22 GPM1 12" 22-30 GPM2"30-50 GPMIRRIGATION PLAN1PLANN0SCALE - FEET303060 S TAT E OF MONTANA LANDSCAPE ARCH ITECT LESSA R.RACOW274 LICENSE D WGMGROUPWWW.WGMGROUP.COMNOT FORCONSTRUCTIONFOR REVIEWSUNDANCE PARK SUNDANCE MINOR SUBDIVISION 3605 BAXTER LANE, BOZEMAN, MT 59718MARCH 12, 2019L1.2PRELIMINARYPLOTTED:SAVED:3/14/193/14/19NOTE:1.INSTALL BACKFLOW PREVENTER PER CODE ANDREQUIREMENTS OF PREVAILING JURISDICTION2.INSULATE PER MANF. RECOMMENDATION.3.INSTALL IN MANF. RECOMMENDED HOUSING.NTSBACKFLOW PREVENTER1DETAIL4" SCH. 80 NIPPLE1 12 CUBIC FEET OF 34"WASHED GRAVEL12"18"FINISH GRADE2" TYP4" TYP 2'-0"NOTE:1.FURNISH FITTINGS AND PIPING NOMINALLYSIZED IDENTICAL TO NOMINAL QUICKCOUPLING VALVE INLET SIZE.SPECIFIED TOP SOILTOP OF BOX 12" ABOVE FINISHGRADE IN TURF. 1" ABOVE FINISHGRADE IN GROUNDCOVER AREAS10"∅ ROUND PLASTIC VALVEBOX WITH LOCKING LIDQUICK COUPLING VALVEPVC SCH. 80 NIPPLE (LENGTHAS REQ.)4" MIN DEPTH OF 34" WASHEDGRAVELPVC SCH. 40 TEE OR ELLMAINLINEPVC SCH. 40 ELLPVC SCH. 40 STREET ELLNO. 4 GALVANIZED STEEL REINFORCINGBAR (DEFORMED) WITH 2 STAINLESSSTEEL GEAR CLAMPS SECURED TO QUICKCOUPLER ASSEMBLY AS SHOWN.NTSQUICK COUPLER2DETAIL3"3"PVC SCH. 80 NIPPLE (LENGTHAS REQ.)NTSBALL VALVE3DETAILFINISH GRADE3"2" TYP4" TYP 1'-6"SPECIFIED TOP SOILTOP OF BOX 1/2" ABOVE FINISHGRADE IN TURF. 1" ABOVEFINISH GRADE IN GROUNDCOVERAREAS10" DIA ROUND PLASTIC VALVEBOX WITH LOCKING LID8" DIA PVC VERTICAL ACCESSRISER, NOTCHED TO FIT OVERMAINLINESPECIFIED GATE VALVEMAINLINEPVC SCH 80 ADAPTER4" MIN DEPTH OF 34" WASHEDGRAVELCOMMON BRICK, 2 REQUIRED180-DEG. APART2"TYPFINISH GRADE1'-6" 1'-0" 8" MIN VALVE BOX WITH LOCKING LID, TOP OF BOX 12" ABOVEFINISH GRADE IN TURF. 1" ABOVE FINISH GRADE INGROUNDCOVER AREASCONTROLLERVALVE IDENTIFICATION TAGREMOTE CONTROL VALVESCH. 80 NIPPLE TYPICAL OF 2PVC UNION TYPICAL OF 2LATERAL LINESPECIFIED TOP SOILCOMMON BRICK, ONE REQUIRED AT EACH CORNER OFVALVE BOX34" WASHED GRAVELBALL VALVE, LINE-SIZED TOMATCH REMOTE CONTROL VALVESCH. 40 45-DEG. ELLSCH. 40 TEE AT MAINLINEMAINLINENTSREMOTE CONTROL VALVE4DETAILFINISH GRADE6" 1'-0" 1'-6"3"TYP3"MIN3"SPECIFIED TOPSOILDETECTABLE METALLIC UNDERGROUNDWARNING TAPE CENTERED OVERHORIZONTAL LOCATIONS OF MAIN ANDLATERAL LINESLATERAL LINESPECIFIED TRENCHBACKFILLMAINLINECONTROL WIRES,BUNDLE BELOW TOPOF MAINLINEUNDISTURBEDSUBGRADENTSTYPICAL TRENCHING5DETAIL18" MIN. LENGTH OF FLEXIBLEPOLYETHYLENE PIPE TOCORRESPOND WITH MNF. OF HEAD.ALL FITTINGS TO BE BY SAMEMNF.TOP OF HEAD TO BE 12" - 1" ABOVE GRADEIN TURF AREAS.SPECIFIED MULCH1'-0"LATERAL LINEBARB ELLSCH. 40 PVC - TEEOR ELL AT LAT. LINEPOP-UP SPRAY SPRINKLERSPECIFIED TOPSOILPVC SCH. 40 - 90-DEG. STREET ELLBARB ELL2"NTS12" POP-UP SPRINKLER6DETAIL2'-0" 1'-0"PAVEMENT SECTIONDETECTABLE METALLICUNDERGROUND WARNINGTAPE CENTERED OVERHORIZONTAL LOCATIONSOF MAIN AND LATERALLINESSPECIFIED TRENCH BACKFILLSPECIFIED SLEEVEMAIN OR LATERAL LINEUNDISTURBED SUBGRADEPAVEMENT FINISH GRADENTSSLEEVING7DETAILFINISH GRADE3"2" TYP4" TYP 1'-6"1'-6"1'-0"SPECIFIED TOP SOILTOP OF BOX 12" ABOVE FINISHGRADE IN TURF. 1" ABOVEFINISH GRADE INGROUNDCOVER AREAS10"∅ ROUND PLASTIC VALVEBOX WITH LOCKING LID8"∅ PVC VERTICAL ACCESSRISER, NOTCHED TO FITOVER MAINLINECOMMON BRICK, 2 REQUIRED180-DEG. APARTSPECIFIED DRAIN VALVEMAINLINEPVC SCH. 80 ADAPTER4" SCH. 80 NIPPLE1 12 CUBIC FEET OF 34"WASHED GRAVELNTSMANUAL DRAIN VALVE8DETAILNTS18" ROOT ZONE WATERING SYSTEM9DETAILNTSI-CORE DECODER METAL CONTROLLER11DETAIL114"NTSI-CORE PLASTIC PEDESTAL CONTROLLER10DETAIL S TAT E OF MONTANA LANDSCAPE ARCH ITECT LESSA R.RACOW274 LICENSE D GALLOWAY STREETEQUESTRIAN LANECABALLO AVENUE CASPIAN AVENUE 23' 23'23'73'LAWNLAWNWPWPWPWPWPWPWPTRAIL CENTER LINE,TYP.13'13'13'13'13'13'13'13'CLR70' R50' R8'TYP R8'R8'R20'R20'R8'R8'R5'TYPR100'R262' R177'R100'R70'R50'R8'R8'R 8 ' T Y P R35'R55'R8'R8'R5'TYPR55'R35'R3'TYPR3'TYPR3'TYPR5'R5'TYPR 8 ' T Y P CL 23'SIDEWALKSIDEWALKCURB & GUTTERCURB &GUTTERCURB & GUTTERPHASE 2: BENCH, TYP.R20'1'TYPR17'R8'4'- 6 "4'-6"6' 4'-6"4'-6"4'-6"4'-6"6'6'6'6'6'6'6'6'6' 6' R20'5'PAVILIONLAWNLAWNLAWNLAWNLAWNLAWNLAWNLAWNLAWN23'PROPOSED SIDEWALKBY OTHERS, SEE CIVILPLANSPROPOSED SIDEWALKBY OTHERS, SEE CIVILPLANS1.THIS SHEET PERTAINS TO HARDSCAPE ELEMENTS TO BE INSTALLEDAS FUTURE PHASE 2.2.ALL PARK AREAS SHALL BE GRADED LEVEL. TOPSOIL SHALL BEIMPORTED AS NECESSARY TO FILL AND LEVEL ANY EXISTINGDEPRESSIONS. GRADE PARKLAND TO ENSURE THAT STORMWATERRUNOFF REMAINS ON SITE. SEE GENERAL NOTES.3.SIDEWALK AND BACK OF CURB LOCATIONS APPROXIMATE. VERIFY INFIELD.4.STUB ELECTRICAL AND IRRIGATION LINES FOR FUTURE PHASE 2EXPANSION.NOTES S TA T E OF MONTANA LANDSCAPE ARCH ITECT LESSA R.RACOW274 LICENSE D WGMGROUPWWW.WGMGROUP.COMNOT FORCONSTRUCTIONFOR REVIEWSUNDANCE PARK SUNDANCE MINOR SUBDIVISION 3605 BAXTER LANE, BOZEMAN, MT 59718MARCH 12, 2019L2.1PRELIMINARYPLOTTED:SAVED:3/14/193/14/19HARDSCAPE LAYOUT PLAN1PLANN0SCALE - FEET3030606'-0"SLOPE MIN. 2%FOR 2"-0"NOTE:REFER AND COMPLY WITH DESIGN GUIDELINES FOR CITYOF BOZEMAN PARKS, TRAIL IIB CLASSIFICATIONS.NTSGRAVEL TRAIL - 6' WIDTH1SECTIONWATER AND ROLL SURFACETO A SMOOTH SEAL3" DEPTH NATURAL FINES3" DEPTH 1" ROAD MIX,COMPACTED.UNDISTURBED SUB-GRADEFILLS COMPACTED TO 95%PROCTOR DENSITY2% CROSS SLOPE STREET VISIONTRIANGLE, TYP.EXISTING UTILITY VAULT. LOCATIONAPPROXIMATE. VERIFY IN FIELD ANDCOORDINATE TRAIL DESIGN WITHOWNER'S REPRESENTATIVEGALLOWAY STREETEQUESTRIAN LANECABALLO AVENUE CASPIAN AVENUE TRAIL, TYP.PHASE 2: BBQ GRILLPHASE 2: PAVILION25' X 25', BY OTHERSPHASE 1: GRAVEL & PHASE 2: CONCRETE PADPHASE 2: PARK SIGN,BY OTHERSPHASE 2: LITTERRECEPTACLE AND PETWASTE STATIONPHASE 2: (4) BIKE RACKSLAWNLAWNIRRIGATION CONTROLLER,WEATHER STATION, ANDWELL LOCATION. SEE L1.1WPPHASE 2: PROVIDE (1) DUAL50-AMP AND (2) 120VWEATHERPROOF OUTLETSWPWPWPWPPHASE 2: LITTERRECEPTACLE AND PETWASTE STATIONPHASE 2: LITTERRECEPTACLE AND PETWASTE STATIONEXISTING UTILITY VAULT. LOCATIONAPPROXIMATE. VERIFY IN FIELD ANDCOORDINATE TRAIL DESIGN WITHOWNER'S REPRESENTATIVEPHASE 2: LITTERRECEPTACLE AND PETWASTE STATIONPHASE 2: LITTER RECEPTACLEPHASE 2: LITTERRECEPTACLEWPWPTRAIL CENTER LINE,TYP.SIDEWALKSIDEWALKCURB & GUTTERCURB &GUTTERCURB & GUTTERCURB &GUTTERPHASE 2: BENCH, TYP.PAVILIONLAWNLAWNLAWNLAWNLAWNLAWNLAWNLAWNLAWNPROPOSED SIDEWALKBY OTHERS, SEE CIVILPLANSPROPOSED SIDEWALKBY OTHERS, SEE CIVILPLANSTREESGRASSESOTHER MATERIALPLANT SCHEDULEB&B OR GROW BAG, LIMB UP 6'HT, SPACING AS SHOWN2" CAL15PRAIRIE EXPEDITION ELM; MATURE SIZE 60'H X 40'WUlmus americana 'Lewis & Clark'B&B OR GROW BAG, LIMB UP 6'HT, SPACING AS SHOWN2" CAL15SHADEMASTER HONEYLOCUST; MATURE SIZE 45'H x 45'WGleditsia triacanthos var. inermis 'Shademaster'SEED AT A RATE OF 8LB/1000SFSEED117,290SFWATER SAVER TURF TYPE FESCUE BLENDLAWNRECOMMENDATIONSTO RUST WITH 15" STAKES; INSTALL PER MAN'F 338LFTREE CIRCLES & AS SHOWN; 3/16" MILLED STEEL EDGINGROUND LANDSCAPE GRAVEL OF LOCAL ORIGIN551SFTREE CIRCLES & AS SHOWN; 1-1/2" WASHED MULCHGENERAL NOTES1.APPROVAL OF THE FINAL PARK PLAN BY THE REVIEW AUTHORITY WITH ARECOMMENDATION FROM THE CITY RECREATION AND PARKS ADVISORYBOARD PRIOR TO ANY SITE WORK IS REQUIRED.2.A PRECONSTRUCTION MEETING IS REQUIRED PRIOR TO ANY SITE WORK.3.A PHASE 1 ENVIRONMENTAL ASSESSMENT OF THE AREA IS REQUIREDTO BE TRANSFERRED TO THE CITY OR PROPERTY OWNERSASSOCIATION.4.ALL CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITHCURRENT CITY OF BOZEMAN STANDARDS, THE STATE OF MONTANABUILDING AND SPECIALTY CODES, AND BAXTER MEADOWS DESIGNGUIDELINES.5.INSTALL EROSION CONTROL SYSTEMS IN ACCORDANCE WITH CITY OFBOZEMAN STANDARDS PRIOR TO SITE WORK AND LANDSCAPEINSTALLATION.6.MARK AND PROTECT ALL UTILITIES, SITE FEATURES, AND VEGETATIONTO BE RETAINED.7.CONTRACTOR TO COORDINATE WITH OWNER'S REPRESENTATIVE ANDUTILITY COMPANIES, LOCATION OF ALL UTILITIES PRIOR TO COMMENCINGWORK. CONTRACTOR IS RESPONSIBLE TO REPAIR DAMAGES TOEXISTING UTILITIES, HARDSCAPES AND STRUCTURES AS A RESULT OFTHE CONTRACTORS ACTIVITIES.8.PRIOR TO PLANTING, ON-SITE TOPSOIL SHALL BE TESTED FOR SOILFERTILITY BY A CERTIFIED TESTING LAB. IF NECESSARY, TOPSOIL FORTREE PITS, SHRUB PITS, AND GROUND COVER BEDS SHALL BE AMENDEDAS RECOMMENDED BY THE SOIL FERTILITY REPORT. TOPSOIL DEPTHSHALL BE A MINIMUM DEPTH OF 6" FOR LAWN AREAS AND 12" FORSHRUB BEDS.9.MATCH GRADES OF LAWNS TO CURBS, SIDEWALKS, AND TRAILS AT A5% MAXIMUM SLOPE AND A 2% MINIMUM SLOPE. TAPER TO EXISTINGGRADES.10.EDGING AS SPECIFIED. INSTALL EDGING AFTER INSTALLATION OFIRRIGATION AND PRIOR TO PLANTING. RE-STAKE EDGING IF NECESSARYAS DIRECTED BY OWNER'S REPRESENTATIVE. EDGE ALL TREE CIRCLES.11.MULCH AS SPECIFIED. MULCH ALL GARDEN BED AND TREE CIRCLES.12.TYPAR PROFESSIONAL LANDSCAPE FABRIC, OR APPROVED EQUAL, TOBE INSTALLED IN ALL GARDEN BEDS AND TREE CIRCLES.PLANTING NOTES1.PRIOR TO PLANTING, CONTRACTOR IS RESPONSIBLE FOR CONTACTINGCITY OF BOZEMAN TO SCHEDULE PRE-CONSTRUCTION MEETING AND TOOBTAIN PROPER TREE PLANTING PERMITS.2.PLANT MATERIAL SHALL CONFORM TO THE CURRENT AMERICANSTANDARD FOR NURSERY STOCK, BY THE AMERICAN NURSERY ANDLANDSCAPE ASSOCIATION. ALL PLANTS TO BE NURSERY GROWN.3.NO SUBSTITUTIONS ALLOWED WITHOUT PRIOR WRITTEN CONSENT FROMTHE OWNER'S REPRESENTATIVE. ANY PLANT OR MATERIAL NOT MEETINGTHE REQUIREMENTS SHALL BE REJECTED, REMOVED, DISPOSED OF ANDREPLACED BY AND AT THE CONTRACTOR'S EXPENSE.4.PLANTS SHALL BE INSPECTED AND APPROVED ON-SITE PRIOR TOPLANTING BY OWNER'S REPRESENTATIVE.5.PLANTS SHALL BE LOCATED BY THE CONTRACTOR AND OWNER'SREPRESENTATIVE SHALL GIVE DIRECTION, MAKE ADJUSTMENTS, ANDAPPROVE LOCATION PRIOR TO INSTALLATION.6.VERIFY ALL QUANTITIES. PLANT QUANTITIES IN THE PLANT SCHEDULEARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TOCOMPLETE THEIR OWN QUANTITY TAKE-OFFS FOR ALL PLANS AND SIZESSHOWN ON THE PLAN. IN CASE OF A DISCREPANCY THE PLANTING PLANSHALL DICTATE QUANTITY.7.SEED/SOD ALL DISTURBED EXISTING LAWN AREAS TOPRE-DISTURBANCE CONDITION.8.BACKFILL TO BE LOOSENED NATIVE SOIL UNLESS AMENDMENT ISNECESSARY AS DICTATED BY SOIL TEST.9.LANDSCAPE CONTRACTOR SHALL WATER PLANTINGS UNTIL IRRIGATIONSYSTEM IS FULLY FUNCTIONAL AND PROVIDE A 1-YEAR WARRANTYPERIOD AFTER INSTALLATION AND GUARANTEE ALL PLANTINGS TO BEALIVE AND IN SATISFACTORY HEALTH.3L3.2TREESSHRUBSGROUND COVEROTHER MATERIALPLANT SCHEDULE - FUTURE PHASE 2B&B OR GROW BAG, SPACING AS SHOWN2" CAL6PRAIRIE EXPEDITION ELM; MATURE SIZE 60'H X 40'WUlmus americana 'Lewis & Clark'FULLY BRANCHED, SPACING AS SHOWNB&B OR GROW BAG, SYMMETRICAL SHAPE6-8'HT10NORWAY SPRUCE; MATURE SIZE 60'H x 30'WPicea abiesMATURE SIZE 25'H x 20'W; B&B OR GROW BAG1.75" CAL20SPRING SNOW FLOWERING CRABAPPLEMalus 'Spring Snow'SYMMETRICAL; FULLY BRANCHED; SPACING AS SHOWN5-GAL8Dwarf Globe Blue Spruce; MATURE SIZE 5'H x 6'WPicea pungens 'Globosa'TRIANGULAR SPACING 30" O.C.4" POT70Walker's Low Catmint; MATURE SIZE 18"H x 30"WNepeta racemosa 'Walker's Low'TRIANGULAR SPACING 30" O.C.4" POT115Moonshine Yarrow; MATURE SIZE 24"H x 30"WAchillea x 'Moonshine'TRIANGULAR SPACING 24" O.C.4" POT51May Night Meadow Sage; 24"H X 24"WSalvia nemorosa 'Rosenwein'INDICATES DROUGHT TOLERANT PLANT SPECIESNOTSHOWN1.THIS SHEET CONTAINS PLANTING PLAN INFORMATION ONLY.2.SEE SHEET L1.1 FOR IRRIGATION PLAN3.SEE SHEET L2.1 FOR HARDSCAPE LAYOUT PLAN4.ALL PARK AREAS SHALL BE GRADED LEVEL. TOPSOIL SHALL BEIMPORTED AS NECESSARY TO FILL AND LEVEL ANY EXISTINGDEPRESSIONS. GRADE PARKLAND TO ENSURE THAT STORMWATERRUNOFF REMAINS ON SITE. SEE GENERAL NOTES.5.SIDEWALK AND BACK OF CURB LOCATIONS APPROXIMATE. VERIFY INFIELD.6.STUB ELECTRICAL AND DRIP IRRIGATION LINES FOR FUTURE PHASE 2EXPANSION.ELECTRICAL KEY - FUTURE PHASE 2WP15" STAKES; INSTALL PER MAN'F RECOMMENDATIONS342LFTREE CIRCLES; 3/16" MILLED STEEL TO RUST WITH EDGINGGRAVEL OF LOCAL ORIGIN, 3" DEPTH252SFTREE CIRCLES; 1-1/2" WASHED ROUND LANDSCAPEMULCHINDICATES DROUGHT TOLERANT PLANT SPECIES50 AMP1WEATHER PROOFDUAL OUTLET120V2WEATHER PROOFOUTLETGRASSESNOTESSEED ALL DISTURBED AREASSEED AT A RATE OF 8LB/1000SFSEEDN/AWATER SAVER TURF TYPE FESCUE BLENDLAWNNOTSHOWNWP3" DEPTH1600SFSHRUB BEDS; ORGANIC COMPOST MULCHMULCHELECTRICAL KEY50 AMP4WEATHER PROOFDUAL OUTLETWPOR APPROVED EQUALLITTER RECEPTACLE, SIDE OPENING, BRONZE POWDER COAT6LANDSCAPE FORMS (800) 521.2546, CHASE PARKLITTER RECEPTACLEGREEN, OR APPROVED EQUAL4ZEROWASTEUSA.COM; THE SENTRY DOG WASTE STATIONPET WASTE STATIONFURNITURE SCHEDULE - FUTURE PHASE 2OR APPROVED EQUAL50" LENGTH, NO ARMS, EMBED MOUNT, BRONZE POWDER COAT6LANDSCAPE FORMS (800) 521.2546, CHASE PARK BENCHBENCHFREE STANDING, OR APPROVED EQUAL; PLACE IN PAVILIONREDWOOD TIMBERS, BRONZE POWDER COAT LEGS,2LANDSCAPE FORMS (800) 521.2546, GRETCHEN PICNIC TABLEPICNIC TABLENOTSHOWNNOTSHOWNOR APPROVED EQUAL4LANDSCAPE FORMS (800) 521.2546, BOLA BIKE RACK ECB-26 WARMING BASKETS SWIVEL SHELF, B2 EMBEDDED MOUNT1PILOT ROCK (800) 762-500; 2EC-26/S GRILLBBQ GRILL6' WIDE2381LFCITY OF BOZEMAN CLASS IIB NATURAL FINES TRAILTRAIL1L3.23L3.23L3.23L3.21L3.23L3.22L3.23L3.22L3.23L3.23L3.23L3.21L2.14L3.2NOTSHOWNNOTSHOWNNOTSHOWNORGANIC COMPOST MULCH, 1" DEPTH OR AS NEEDED1600SFAMEND EXISTING SHRUB BEDS; MULCH3L3.2 S TA T E OF MONTANA LANDSCAPE ARCH ITECT LESSA R.RACOW274 LICENSE D WGMGROUPWWW.WGMGROUP.COMNOT FORCONSTRUCTIONFOR REVIEWSUNDANCE PARK SUNDANCE MINOR SUBDIVISION 3605 BAXTER LANE, BOZEMAN, MT 59718MARCH 12, 2019L3.1PRELIMINARYPLOTTED:SAVED:3/14/193/14/19PLANTING PLAN1PLANN0SCALE - FEET303060 S TA T E OF MONTANA LANDSCAPE ARCH ITECT LESSA R.RACOW274 LICENSE D WGMGROUPWWW.WGMGROUP.COMNOT FORCONSTRUCTIONFOR REVIEWSUNDANCE PARK SUNDANCE MINOR SUBDIVISION 3605 BAXTER LANE, BOZEMAN, MT 59718MARCH 12, 2019L3.2PRELIMINARYPLOTTED:SAVED:3/14/193/14/19NTSTRIANGULAR SPACING4DETAILGARDEN BEDEDGE2/3 ON CENTER SPACING ON CENTERSPACINGON CENTERSPACINGON C E N T E R SP A C I N G NOTE:ON CENTER SPACING SHALL BE ASINDICATED IN THE PLANT SCHEDULE.NTSSHRUB & GROUND COVER PLANTING2DETAILNOTES:1.ALL SHRUBS TO BE PLANTED SHALLHAVE THE SAME RELATIONSHIP TO FINISHGRADE AS ORIGINALLY GROWN IN THENURSERY.PULL MULCH 3" AWAY FROM TRUNK.FINISH GRADEREMOVE ROOT CONTAINMENTMATERIALS, TAGS, LABELS, ANDSTRINGS.BACKFILL AS SHOWN. PLANTING SOILMIX AS SPECIFIED. PLANTING DEPTH TOMATCH FINISH GRADE.EXCAVATE SLOPING SHALLOW PITTWICE THE DIAMETER OF THE ROOTBALL. DEPTH OF PIT TO BE NO GREATERTHAN THE HEIGHT OF THE ROOT BALL.ALL WALLS TO BE FRACTURED ANDUNGLAZED.MULCH AND WEED BARRIER FABRIC. SEEEDGING , MULCH & FABRIC DETAIL.NTSEDGING, MULCH & WEED BARRIER3DETAIL 1/2 "DEPTH OF MULCH VARIES BY TYPE.INSTALL TO DEPTH AS SPECIFIED.FINISHGRADEEDGING AS SPECIFIED. INSTALLACCORDING TO MFG.'S SPECIFICATIONS.WEED BARRIER FABRIC AS SPECIFIED. LAP6" AT JOINTS.8" STAPLES TO ANCHOR WEED BARRIER,TRIANGULAR SPACING 3' O.C. AND 1' O.C.LINEAR SPACING AT JOINTS.NTSTREE PLANTING1DETAILPRUNE TREE AS SPECIFIED TO RETAINNATURAL FORM AND TO REMOVE DEADOR DAMAGED LIMBS OR BRANCHES.ROUND WOOD TREE STAKES AND FLATGROMMET TREE STRAPS AS SHOWN.STAKES SHALL NOT PENETRATE ROOTBALL. STAKES SHALL BE REMOVEDAFTER TWO YEARS.NOTES:1.TREE STAKING IS MANDATORY.2.ALL TREES TO BE PLANTED SHALL HAVE THE SAME RELATIONSHIP TO FINISH GRADEAS ORIGINALLY GROWN IN THE NURSERY.3.PROVIDE A 18" MULCH AND EDGING RADIUS AROUND TREES IN TURF AREA. SEEEDGING, MULCH & FABRIC DETAIL.FINISHGRADEEXCAVATE SLOPING SHALLOW PITTWICE THE DIAMETER OF THE ROOTBALL. DEPTH OF PIT TO BE NOGREATER THAN THE HEIGHT OFTHE ROOT BALL. ALL WALLS TO BEFRACTURED AND UNGLAZED.PULL MULCH 3" AWAY FROM TRUNK.PROVIDE ORGANIC COMPOST MULCH FORFIRST 12" DIAMETER. ROCK MULCHTHEREAFTER. MULCH AND WEEDBARRIER FABRIC AS SPECIFIED.18"REMOVE BURLAP, WIRE BASKET, TAGS,LABELS, AND STRINGS.BACKFILL AS SHOWN. PLANTINGSOIL MIX AS SPECIFIED.TRUNK PROTECTION WRAP. INSTALL INTHE FALL AND REMOVE IN SPRINGANNUALLY.12"