Loading...
HomeMy WebLinkAboutLS4.1-Irrigation Details_2019-08-01TH I S D R A W I N G I S T H E I N T E L L E C T U A L P R O P E R T Y O F I N - S I T E D E S I G N G R O U P . D O N O T C O P Y O R R E P R O D U C E I N A N Y W A Y W I T H O U T T H E E X P R E S S W R I T T E N P E R M I S S I O N O F I N - S I T E D E S I G N G R O U P . C O P Y R I G H T © 2 0 0 6 ar c h i t e c t s @ i n - s i t e d e s i g n g r o u p . c o m 17 N o r t h 4 7 0 W e s t A m e r i c a n F o r k , U t a h 8 4 0 0 3 80 1 . 7 5 6 . 5 0 4 3 w w w . i n - s i t e d e s i g n g r o u p . c o m BI D A N D P E R M I T S E T TS E TA O T N F O M CETIHCRA EPACSDN A L D E S N E C I L T Co r y B . Wh i t i n g # 1 0 6 2 9 A N A 8- 1 - 1 9 BO Z E M A N - M T 81 5 E . M A I N S T . RE S I D E N C E I N N IR R I G A T I O N D E T A I L S LS4.1 18-142 ---- ---- ---- 08-01-2019 CBW JEV CONDUIT, FITTINGS AND SWEEP ELL OUT TO RAINBIRD RAIN SENSOR. CONDUIT, FITTINGS AND SWEEP ELL TO POWER SUPPLY WALL MOUNTED RAINBIRD CONTROLLER. CONDUIT, FITTINGS AND SWEEP ELL OUT TO ADJACENT LAWN OR PLANTER AREA FOR VALVE CONNECTIONS. NOTES: 1.MOUNT CONTROLLER PER MANUFACTURER'S WRITTEN INSTRUCTIONS AND IN ACCORDANCE WITH ALL LOCAL CODES. EXACT LOCATION TO BE APPROVED BY OWNER. GROUND CONTROLLER PER MANUFACTURERS RECOMMENDATION AND SPECIFICATIONS. ELECTRICAL CONTRACTOR SHALL GROUND CONTROLLER. LANDSCAPE CONTRACTOR SHALL PROVIDE SLEEVING FROM ADJACENT PLANTER AREA TO CONTROLLER LOCATION. 2.CONNECT CONTROLLER TO POWER AND VALVES. 3.REFER TO SPECS FOR ADDITIONAL INFORMATION. 4.MOUNT SENSOR WITH IN 25 FEET OF CONTROLLER IN FULL SUN POSITION. CONTROLLER WITH SENSOR SCALE: NTS1 1" RPZ BACK FLOW PREVENTION DEVICE AND MISC FITTINGS AS NECESSARY. SEE DETAIL: 1" STOP AND WASTE VALVE AND MISC. FITTINGS AS REQUIRED BURIED AT OR BELOW FROST DEPTH TO AVOID FREEZING. INSTALL GRAVEL DRAIN SUMP FOR WATER TO DRAIN OUT OF THE SERVICE LINE AT TIME OF WINTERIZATION. WATER METER OR CONNECTION INSIDE BUILDING (COORDINATE WITH PLUMBING AND MECHANICAL). SEE CIVIL DRAWINGS FOR MORE INFORMATION. A MIN. OF 23 GPM IS REQUIRED FOR IRRIGATION SYSTEM WITH 1-1/4" STUB. THE GENERAL CONTRACTOR TO INSTALL WATER LINE FROM THE BUILDING TO THE ADJACENT LANDSCAPE AREA. 4" THICK CONCRETE PAD FOR RPZ. SIZE PAD AS NECESSARY WITH MIN. 6" CLEARANCE FROM EDGE OF BACKFLOW ENCLOSURE TO EDGE OF CONCRETE PAD. INSTALL MANUAL DRAIN VALVE PER DETAIL: IF NO LOW POINT EXISTS AT THE P.O.C. AND THE LINES CAN BE ADEQUATELY DRAINED, NO DRAIN WILL BE REQUIRED. 1 1/4" GALVANIZED PIPE (OR 150 PSI HIGH DENSITY POLY PIPE) FROM WELL TO STOP AND WASTE VALVE BURIED AT FROST DEPTH OR BELOW TO AVOID FREEZING. FIELD VERIFY EXACT LOCATION. 1 1/4" SCH 40 PVC MAINLINE PIPE. WM 1 1/4" GALVANIZED PIPE FROM 2' BEFORE RPZ TO 2' DOWNSTREAM OF RPZ. NOTES: 1.USE A DIELECTRIC UNION WHEREVER A COPPER-BASED METAL (COPPER, BRASS, BRONZE) IS JOINED TO AN IRON-BASED METAL (IRON, GALVANIZED STEEL, STAINLESS STEEL). 2.MODIFY THIS DETAIL AS NECESSARY FOR BUILDING CONNECTION VS. MATER METER CONNECTION. THE CONTACTOR SHALL ENSURE THAT THE MAINLINE CAN BE TURNED OFF AND WINTERIZED PROPERLY. 1 1/4" POINT OF CONNECTION SCALE: NTS2 10 LS4.1 3 LS4.1 GALV. ELL WITH REDUCER FITTING PVC SLEEVE GALV. ELL OPTIONAL MANUAL DRAIN VALVE INSTALLED AT THE LOW POINT. SEE DETAIL: 1 14" SCHEDULE 40 PVC MAINLINE. SEALANT 4" CONC. SLAB FROM WATER SOURCE SEALANT FINISH GRADE BACKFLOW PREVENTOR ASSEMBLY GALV. ELL WITH REDUCER FITTING LOCKING DEVICE HINGE OR LOCK GALV. NIPPLE 1 14"GALV. NIPPLE (LENGTH AS REQ.) 1 14 " GALV. NIPPLE, 24" LENGTH. GALV. NIPPLE (LENGTH AS REQ.) GALV. NIPPLE (LENGTH AS REQ.) GALV. FTP COUPLER WITH GALV. NIPPLES, LENGTH AS REQ. (IF REQ.)WYE STRAINER LINE SIZE. 'OPTIONAL' NETAFIM 2" HYDROMETER INSTALL PER MANUFACTURERS RECOMMENDATIONS. CONNECT TO IRRIGATION CONTROLLER AND FLOW COMPUTER. FLOW1 14 " GALVANIZED PIPE BACKFLOW PREVENTOR NOTES: 1.BACKFLOW ENCLOSURE IS REQUIRED TO BE SECURED WITH A LOCK. SIZE ENCLOSURE AS NECESSARY. 2.EQUIPMENT TO BE INSTALLED AT A MINIMUM OF 24" FROM ANY STRUCTURES OR HARDSCAPING. 3.WHEN UNIT IS NEXT TO STRUCTURE (i.e. WALL BUILDING, ETC.) MOUNT TEST COCKS ON SIDE AWAY FROM STRUCTURE. 4.CONTRACTOR SHALL PROVIDE ALL MATERIALS NECESSARY FOR PROPER RPZ INSTALLATION. 5.ALL FITTINGS, NIPPLES, ETC FOR RPZ CONSTRUCTION TO BE LINE SIZED. INSTALL ADDITIONAL MISC. FITTINGS AS NECESSARY. 6.RPZ TO BE WINTERIZED AS NECESSARY TO PREVENT FREEZING. INSULATION IS REQUIRED TO PREVENT RPZ FROM FREEZING TEMPERATURES BEFORE SYSTEM IS BLOWN OUT FOR THE SEASON. CONTRACTOR SHALL PROVIDE INSULATION BLANKET FOR RPZ. 7.SLOPE CONCRETE PAD AT 2% TO ENSURE PROPER DRAINAGE OFF OF PAD. CONCRETE SHALL BE MIN. 3000 PSI. SUBMIT DESIGN MIX TO OWNER FOR APPROVAL. INSTALL 4" DEPTH OF 34" WASHED GRAVEL BASEUNDER CONCRETE PAD. 8.CARE SHALL BE TAKEN WHEN BLOWING AIR THROUGH SYSTEM FOR WINTERIZATION. WINTERIZE THE RPZ AND IRRIGATION SYSTEM PER MANUFACTURER SPECS. 1" WILKINS RPZ BACKFLOW PREVENTOR MODEL 375S WITH RK112 BOF TO BE INSTALLED PER LOCAL CODE. 1" BACKFLOW PREVENTOR SCALE: NTS3 GUARDSHACK BACKFLOW ENCLOSURE (SIZE AS NECESSARY). INSTALL PER MANUFACTURER'S RECOMMENDATIONS. SEE WWW.BPDI.COM FOR INSTALLATION PROCEDURES. GALV. TO PVC CONNECTION.. 1 14" SCH. 40 PVC (LENGTH AS REQ.) 1 14" CULINARY WATER LINE FROMMETER. SEE CIVIL PLANS. 3/4" MINUS GRAVEL SUMP: (2) 5 GAL. BUCKETS. DRAIN SUMP TO BE LINED ON ALL SIDES WITH FILTER FABRIC. 1" STOP AND WASTE VALVE WITH REDUCER FITTING 1 14" PVC STOP & WASTE RISER PIPE WITH CAP.EXACT LOCATION TO BE APPROVED BY OWNER AND CITY. 10 LS4.1 1 14 " GALV. NIPPLE, 24" LENGTH. TRENCH SECTION SCALE: NTS PLAN VIEW WIRE W/O CONDUIT SECTION VIEW TIE A 24-INCH LOOP IN ALL WIRING AT CHANGES OF DIRECTION OF 30° OR GREATER. UNTIE AFTER ALL CONNECTIONS HAVE BEEN MADE. ALL SOLVENT WELD PLASTIC PIPING TO BE SNAKED IN TRENCH AS SHOWN. RUN WIRING BENEATH AND BESIDE MAINLINE. TAPE AND BUNDLE AT 10-FOOT INTERVALS. NOTES: 1.SLEEVE BELOW ALL HARDSCAPE ELEMENTS (WITH CLASS 200 OR SCH. 40 OR SCH. 80 PER SPECS.) TWICE THE DIAMETER OF THE PIPE OR WIRE BUNDLE WITHIN. 2.FOR PIPE AND WIRE BURIAL DEPTHS, SEE NOTES AND SPECS. 3.NO LINE VOLTAGE WIRING SHALL BE ALLOWED IN IRRIGATION TRENCHES. MAINLINE, LATERAL, AND WIRING IN THE SAME TRENCH MAINLINE PIPE LATERAL PIPE WIRING IN CONDUIT LATERAL LINE MAIN LINE WIRE PIPE, WIRE, AND TRENCH SCALE: NTS5 PVC CAP(TYP.) PAVING PAVING DITCH PVC CAP (TYPICAL) PAINT ENDS PINK AND LABEL AS 'IRR. SLEEVE' CLASS 200 SLEEVES OR GREEN ABS PIPE SIDE BY SIDE NOTE: 1.WHERE THERE IS MORE THAN ONE SLEEVE, EXTEND THE SMALLER SLEEVE TO 24-INCHES MINIMUM ABOVE FINISH GRADE. 2.ALL SLEEVES INSTALLED SHALL BE DUCT TAPED TO PREVENT DIRT OR OTHER DEBRIS ENTERING PIPE. ALL SLEEVES SHALL BE IDENTIFIED BY WOOD OR PVC STAKES AND BE SPRAY PAINTED WITH MARKING PAINT. REMOVE STAKES ONCE IRRIGATION SYSTEM IS COMPLETE. 18" MIN 24" MIN. TO FINISH GRADE 24" MIN. 30" MAX. SLEEVING SCALE: NTS6 RAINBIRD 44LRC QUICK COUPLER VALVE NOTES: 1.FLUSH ALL PIPING PRIOR TO INSTALLING VALVE. 2.WRAP ALL THREADS WITH TEFLON TAPE. 1.1/2 TO 2 WRAPS MAXIMUM. 3.COMPACT SOILS AROUND VALVE BOX TO 80% OF ORIGINAL DRY DENSITY. 4.INSTALL GEOFABRIC UNDER VALVE BOXES AND TAPE TO PIPE NIPPLES AND VALVE BOX. 5.BOX COLOR - GREEN IN TURF AND TAN IN PLANTER AREAS. 6.IRRIGATION SYSTEM TO BE BLOWN OUT WITH AIR COMPRESSOR THROUGH THE RPZ AND QUICK COUPLERS BEFORE FREEZING TEMPERATURES OCCUR, TYP. 7.SCH 80 PVC TEE OR ELL'S CAN BE USED ON ALL QUICK COUPLERS EXCEPT AT POINT OF CONNECTION (IF QUICK COUPLER(S) ARE INSTALLED AT THE POINT OF CONNECTION). ALL QUICK COUPLER FITTINGS AND NIPPLES AT P.O.C. QUICK COUPLER(S) TO BE GALVANIZED. VALVE BOX (SIZE AS REQUIRED) WITH EXTENSIONS IF NECESSARY INSTALL TOP OF VALVE BOX 1/2" ABOVE FINISH GRADE IN LAWN AREAS AND FLUSH WITH TOP OF MULCH IN PLANTERS. HEAVY DUTY GALVANIZED FASTENERS (2 REQUIRED) SCH. 80 NIPPLES 3/4" MIN GRAVEL BASE SCH. 80 STREET ELL MANIFOLD SCH. 80 TEE. SCH. 80 ELL AND STREET ELL 30" X 1" GALVANIZED ANGLE IRON STAKE QUICK COUPLER VALVE SCALE: NTS BRICK (1 OF 3). NOT REQUIRED IF RAINBIRD VALVE BOX IS USED. 7 LATERAL LINE SCH.40 PVC LATERAL PIPE PER PLAN. SIZE PER PLAN. VALVE & FITTINGS, VALVE BOX PER PLAN. 1" SCH. 80 TEE OR ELBOW. 1" X 1" SCH 80 TEE WITH QUICK COUPLER PER PLAN, QUICK COUPLER IN 10" ROUND VALVE BOX. 1" SCHEDULE 80 PVC, TYPICAL (LENGTH AS REQ.) SCHEDULE 80 PVC TEE OR ELL, SIZE AS REQUIRED. LATERAL LINE LATERAL LINE NOTES: 1.ALL VALVE MANIFOLD PIPING AND FITTINGS TO BE 2" SCH. 80 FITTINGS, UNLESS THERE IS A DRIP ZONE ALL BY ITSELF IN WHICH CASE THE PIPING SHALL BE SIZED PER THE FLOW OF THE DRIP ZONE. 2.MODIFY MANIFOLD AS NECESSARY DEPENDING ON HOW MANY VALVES ARE IN A CLUSTER. 3.MODIFY AS REQUIRED DEPENDING ON WHETHER THE VALVES ARE PARALLEL OR PERPENDICULAR TO MAINLINE. MAINLINE 1" VALVE MANIFOLD SCALE: NTS SEE DETAIL: SEE DETAIL: AND: 8 9 LS4.1 11 LS4.1 10 LS4.1 MANIFOLD PIPING, SIZE PER PLAN) MANIFOLD SEE DETAIL: NOTES: 1.MAXIMUM 2 VALVES PER VALVE BOX. 2.MODIFY AS REQUIRED DEPENDING ON WHETHER THE VALVES ARE PARALLEL OR PERPENDICULAR TO MAINLINE. 3.USE GREEN BOXES IN LAWN AREAS & TAN BOXES IN PLANTER AREAS. 4.BOXES WITH 2-VALVES SHALL BE A JUMBO SIZED BOX OR BIGGER PER LANDSCAPE ARCHITECTS DIRECTION. 30" LINEAR LENGTH OF WIRE, COILED WATER PROOF CONNECTION (1 OF 2) VALVE BOX WITH COVER: SIZE AS NECESSARY FINISH GRADE/TOP OF MULCH REMOTE CONTROL VALVE. SEE LEGEND FOR MODEL PVC SCH 80 UNION (LINE SIZE) PVC SCH 80 NIPPLE PVC SCH 80 NIPPLE (LENGTH AS REQUIRED) BRICK (1 OF 4) REQUIRED IF RAINBIRD VALVE BOX IS NOT USED SCH 80 NIPPLE (2" LENGTH, HIDDEN) AND SCH 80 ELL. PVC SCH 80 UNION (PVC COUPLER NOT SHOWN) PVC LATERAL PIPE 3" MINIMUM DEPTH OF 3/4" MINUS WASHED GRAVEL PVC SCH 80 ELL 3" MIN. PRE-PRINTED CHRISTY VALVE ID TAG, TYP. A1 CONTROL VALVE SCALE: NTS NOTES: 1.THE PRS OPTION FOR CONTROL VALVES CAN BE DELETED IF THE STATIC PRESSURE AT THE VALVE IS LESS THAN 70PSI ON SPRAY ZONES, AND LESS THAN 75PSI ON 5000 SERIES ROTOR ZONES. 2.PRS OPTION IS REQUIRED FOR FALCON ZONES. 8 LS4.1 9 SCH. 40 PVC COUPLER 30" COILED WIRE RECTANGULAR VALVE BOX MAIN SUPPLY LINE 18" DEEP MINIMUM SCH. 80 ST ELL SCH. 80 PVC "ACTION" UNION 3" DEPTH OF 34" MINUSWASHED GRAVEL LIMIT 2 VALVES PER VALVE BOX SCH. 40 PVC LATERAL LINE 12" DEEP MINIMUM SCH. 80 PVC "ACTION" UNION 12" MAXIMUM FROM CONCRETE WALK OR MOWSTRIP NOTE: 1.ADD PRE-PRINTED CHRISTY I.D. TAGS TO ALL NEW CONTROL VALVES AND CONTROL ZONE KITS. COORDINATE AND LABEL ALL CONTROL WIRE AT CONTROLLER WITH EACH VALVE IN THE FIELD, TYP. VALVE ASSEMBLY SCALE: NTS11MANUAL DRAIN SCALE: NTS10 PVC MAINLINE. COMPACTED BACKFILL LATERAL PVC LINE TOPSOIL, SEE LANDSCAPE PLAN AND DETAILS FOR DEPTHS FINISH GRADE MULCH IN PLANTER AREA (WITH WEED BARRIER) OR SOD IN LAWN AREAS. SEE LANDSCAPE PLAN AND DETAILS FOR DEPTHS CONTROL WIRE. INSTALL BESIDE & BELOW TOP OF MAINLINE. INSTALL IN CONDUIT WHEN WIRE LEAVES MAINLINE TRENCH. SCALE: NTS NOTES: 1.PROVIDE SLACK IN CONTROL WIRES AT ALL CHANGES IN DIRECTION. 2.MAINLINE DEPTH SHALL BE 18" DEEP EXCEPT UNDER ASPHALT & CONCRETE PAVING AND AT P.O.C. SHALL BE MIN OF 24" & MAX OF 30". INSTALL ADDITIONAL FITTINGS & RESTRAINTS AS REQUIRED. 3.MAINLINE AND LATERAL LINES SHALL BE KEPT MIN. 12" FROM ALL SIDEWALKS AND CURBS. 4 NOTES: 1.MODIFY THIS DETAIL AS NECESSARY FOR BUILDING CONNECTION VS. WATER METER CONNECTION. THE OWNER MAY REQUEST THE RPZ TO BE INSTALLED INSIDE THE HOTEL. NOT USED 4 SITE PLAN REVISION #4 08/01/2019