Loading...
HomeMy WebLinkAboutA101-Floor PLan Level 2_2019-08-01DN UP HS K P 21 4 PO O L & S P A 24 3 FI T N E S S 24 5 PO O L M E C H . 24 1 PO O L E Q U I P . 24 0 PO O L B A T H 24 2 CH E M I C A L C L O S E T EY E W A S H PB X 21 4 . 1 ST A I R # 2 ST -2 ST A I R # 1 ST -1 CO R R I D O R 20 0 ST O R . 22 5 EL E V . L O B B Y 21 2 2B L 20 1 1B A R I S 20 2 SU Q Q T C R 20 3 SU K C L 20 4 SU Q Q S R 20 5 SU K L 20 6 SU K 2 L 20 8 SU Q Q S L 20 9 SU K 2 R 21 0 SU Q Q T C L 21 1 SU K 2 C R 21 3SU K 2 L 21 5 SU K 2 A T 21 6 SU K 2 R 21 7 SU K 2 L 21 8 SU K 2 L 21 9 SU K 2 R 22 0 SU K 2 R 22 1 SU K 2 L 22 2 SU K L W 22 3 SU K 2 R 22 4 SU K 2 R 1 22 6 SU K A R I S B 22 8 SU K 2 R B 23 0 SU Q Q S L 23 1 SU Q Q S R 23 2 SU Q Q S R 23 3 SU Q Q S L 23 4 SU Q Q S L 23 5 SU Q Q S R 23 6 SU Q Q S R 23 7 SU Q Q S L 23 8 ST O R . 22 0 . 1 CO R R I D O R 24 4 TR A S H 25 1 ST O . 25 2 DS DS DS ME C H . 24 5 . 1 1 4 ' - 8 " 2 6 8 ' - 1 1 / 4 " 54 ' - 3 " 6 5 ' - 3 " 20 1 ' - 1 1 " 1" / 1 2 " 1" / 1 2 " 1 " / 1 2 " PLAN LEGEND & NOTES SEE SHEET A007 SHEETS FOR FIRE -RESISTIVE ASSEMBLIES SEE ENLARGED PLANS FOR WALL TAGS NOT SHOWN1.2.DOOR TYPE --SEE SCHEDULE SHT A600 WINDOW TYPE --SEE WINDOW ELEVATIONS ON SHT A610 3.SEE SHEETS A430 -A442 FOR ENLARGED GUESTROOM AND COMMONS ROOM PLANSSEE SHEETS A400 FOR ENLARGED PLANS 4.SEE ENLARGED PLANS FOR DOORS & WINDOWS NOT SHOWN RECESSED 2 -A/10BC FIRE EXTINGUISHER CABINET -SEE 14/A510 -LOCATE PER IFC5.INDICATES ADA ACCESSIBLE UNIT WITH MOBILITY FEATURESSURFACE MOUNTED 2 -A/10BC FIRE EXTINGUISHER F.E.XX 01 1i F.E.C.ALL DIMENSIONS ARE TO FACE OF STUD U.N.O. DO NOT SCALE DRAWINGS.SEE ELECTRICAL DRAWINGS FOR LOCATION OF EXIT SIGNS AND SMOKE DETECTORS SEE MECHANICAL SHEETS FOR LOCATION OF FIRE DAMPERS AND COMBINATION FIRE/SMOKE DAMPERS8.REFER TO PROJECT MANUAL FOR INTERIOR FINISH SCHEDULE9.WALL AND CEILING MATERAILS SHALL MEET THE FLAME SPREAD CLASSIFICATION IN IBC TABLE 803.510.ALL AUDIBLE AND VISUAL ALARMS SHALL COMPLY WITH THE PROVISIONS OF NFPA 7211.BEARING FRAMING MEMBER SIZES PER STRUCTURAL12.SEE A462 FOR STAIR IDENTIFICATION SIGNAGE13.ALL INTERIOR FLOOR AND FINISH COVERINGS TO BE CLASS 1 PER IBC 804.214.INDICATES ADA ACCESSIBLE UNIT WITH COMMUNICATION FEATURES REFER TO SHEETS A005 -A006A FOR WALL ASSEMBLIES.15.DOORS TO BE 4" FROM ADJACENT WALL U.N.O.16.TO MAXIMUM EXTENT POSSIBLE, FLOOR CLEAN OUTS ARE TO BE LOCATED IN INCONSPICUOUS PLACES AND NOT IN GUESTROOMS. ALL FLOOR CLEAN OUTS LOCATED IN CARPETED AREAS ARE TO BE FITTED WITH CARPET INSERTS. ALL CLEANOUTS TO BE FLUSH TO FLOOR/WALLS.17.ALIGN FINISHES WHERE DISSIMLAR WALL TYPES MEET, U.N.O.18.6.7.19.20.FIRE SPRINKLER AND FIRE ALARM SYSTEM DRAWINGS ARE TO BE COORDINATED BY FIRE ENGINEER/CONTRACTOR TO BE CLMPLIANT WITH ALL LOCAL CODES/JURISDICTIONS, AND MARRIOTT DESIGN MODULE 14.21.INSTALL CONTINUOS 2X BLOCKING IN ALL STUD WALLS @ 4'-0" O.C. VERTICAL (MAX.).22.PROVIDE FULL HEIGHT CORNER GUARD AT ALL WALL RETURNS IN PUBLIC SPACE AND GUESTROOM CORRIDORS.23.PLAN VIEW -HEAVY; ELEMENTS CUT THROUGH PLAN VIEW -LIGHT; ELEMENTS NOT CUT THROUGH OVERHEAD; ELEMENTS ABOVE THE CUT PLAN HIDDEN -ELEMENTS BELOW OR BENEATH CENTERLINE -ANNOTATIVE ELEMENTS SUCH AS SECTIONS, GRID LINES, ETC.LINE TYPE LEGENDARCHITECT15200 52nd Ave. South Suite 300 Seattle, WA 98188 Phone 206.766.8300JEFFREY A.AIA WILLIAMS PROJECT #:DRAWN BY:CHECKED BY: F I L E N A M E : THESE DRAWINGS WERE PREPARED FOR THE PROJECT IN . © JOHNSON BRAUND, INC. THEY ARE NOT INTENDED FOR USE ON ANY OTHER PROJECT.Rev.DateDescription OWNER/APPLICANTSTAMPSET NO.DATEDESCRIPTION 110.17.2018SITE PLAN SUBMITTAL C : \ U s e r s \ B r e n d a n S \ D o c u m e n t s \ 1 8 2 1 _ M R I B o z e m a n M T _ 1 8 0 6 0 7 _ B r e n d a n J B S m i t h . r v t 6 / 6 / 2 0 1 9 9 : 4 6 : 2 5 A M A101FLOOR PLAN -LEVEL 2BOZEMAN HOTEL GROUP, LLC SITE ADDRESS : 815 E. MAIN STREET BOZEMAN, MONTANA 59715 CheckerRESIDENCE INN BOZEMAN MT Author1821RESIDENCE INN BOZEMAN MT 1735 S 19TH AVENUE, SUITE B BOZEMAN, MT 59718 1/ 1 6 " = 1 ' - 0 " 1 LE V E L 2 11.31.2019SITE PLAN CYCLE 1 RESUBMITTAL 24.19.2019SITE PLAN CYCLE 2 RESUBMITTAL 306.07.2019SITE PLAN CYCLE 3 RESUBMITTAL