HomeMy WebLinkAbout90- City Hall Basement Fire Sprinkler System +\,.',:, Y' . j~ f-7 1::' CE . , . - M,"~'( I I :)~'':- I ASSOCIATED CONSTRUCTION ENGINEERING. INC. p.O. BOX "'26 'P.o.80X SS1 BlWNGs, M()N1j\NA 519toot fB,.GRADE. MON'f.lI.NA 5971i.osSot 2020 GRAND AVEM.E. ~ 20S GAUATlNREID 8UUlING '34.SlDTE 105 8I1JNGS. ~ 59102 BElGRADE. MON"n\NA 59714-3SOI 4H)6.6S2-630S 106-388-3320 R\X 406652-517) R\X 4Q6.38s.1887 May 15, 1990 city of Bozeman Po 0_ Box 640 Bozeman, MT 59715, Attention: Mr. Dan Figgins . Fire Marshall RE: city Hall Basement Fire Sprinkler System Dear Dan: . \ After our meeting this morning 'pertaining to the fire sprinkler system for the basement of the City Hall, I submit to you the following conditions.' for the sprinkler system: 1- The sprinkler system shall be hydraulically designed for the operation of four sprinkler heads using the water service that is presently in the basement of the city Hall. You will note that this hydraulic calculation will have a source in the existing janitor's room which is 3/4" copper coming directly off of the main water line in the str.eeto We are also considering a parallel connection to the existing 1-1/4" copper domestic water line located nearby. 2. An additional set of hydraulic calculations will be made to adequately size this system and comply with NFPA 13 requirements for a light hazard occupancy 0 This calculation,~ill assume a future connection to the city water supply in the basement of the fire station in the main mechanical room. This connection will be made ahead of the domestic water line val~es. ~',-.... -. . 3. The worst set of hydraulics will be used to size the system 0 , 4. Materials for this system will be CPVC pipe and fittings. The system will have a combination of exposed and concealed pipes. . a:CITYHALL.OOl ., """"","..,;..,.. '^"'.,:J.. .."". '....,.. ., .-." .,..'~ .,., .0...:_. .,. ,'."1 " ,:..., ,~ ". ,,~,.. - ~, ,... ,.'wO'. , .., '- ."......~.,,,':I~.- I'"~ ".. .. lL' :.". 7 ., . . ~ .. , ,~ , Based upon the above criteria, we will expect that the probable cost of the system will be below $10,000.00. Associated Construction Engineering, Inco will design a system which complies with the above design criteria. We will issue the contract drawings and specifications to fire protection contractors for estimates, and we will inspect the completed installation for compliance to the contract documents for a fee of lOt of the fire sprinkler contract. Your signature at the bottom of this letter will signify to us your acceptance of the conditions, and we will proceed for a timely completion of this project upon receipt of a signed copy of this letter. Very truly yours, ASSOCIATED CONSTRUCTION ENGINEERING, INCo JOHN E. PETERSON Fire Protection Engineer JEP:kes CITY OF BOZEMAN BY: ~~J~ t,-I(-~o ~ }-n tI . DATE . a:CITYHALL.OOl I.\';';'~:"q "4""