HomeMy WebLinkAbout008.2-A1-01 - TRIPLEX MAIN LEVEL PLAN 4-1-2019UP
UP
UP
RE
F
.
RE
F
.
RE
F
.
DW
DW
DW
WH
WH
WH
6"8"6’ − 10"11’ − 10"4’ − 2 1/2"1’ − 11 1/2"2’ − 4 1/2"3’ − 11 1/2"4’ − 0"8’ − 6"3’ − 8"48’ − 6"
13
D
C
B
A
25
’
−
0
"
25
’
−
0
"
25
’
−
0
"
1−
1
0
0
1−
1
0
2
LI
V
I
N
G
CE
I
L
I
N
G
:
9’
−
1
1
/
8
"
KI
T
C
H
E
N
CE
I
L
I
N
G
:
9
’
−
1
1
/
8
"
LI
V
I
N
G
CE
I
L
I
N
G
:
9’
−
1
1
/
8
"
KI
T
C
H
E
N
CE
I
L
I
N
G
:
9
’
−
1
1
/
8
"
LI
V
I
N
G
CE
I
L
I
N
G
:
9’
−
1
1
/
8
"
KI
T
C
H
E
N
CE
I
L
I
N
G
:
9
’
−
1
1
/
8
"
2’
−
1
0
"
11
"
7’
−
4
"
6’
−
9
1
/
2
"
7’
−
0
3
/
8
"
2
1
/
4
"
2’
−
8
"
11
"
7’
−
4
"
6’
−
9
1
/
2
"
7’
−
1
1
/
4
"
2
1
/
4
"
7’
−
0
3
/
8
"
6’
−
9
1
/
2
"
7’
−
4
"
11"2’ − 10"
MU
D
R
O
O
M
CE
I
L
I
N
G
:
9’
−
1
1
/
8
"
MU
D
R
O
O
M
CE
I
L
I
N
G
:
9’
−
1
1
/
8
"
MU
D
R
O
O
M
CE
I
L
I
N
G
:
9’
−
1
1
/
8
"
DI
N
I
N
G
CE
I
L
I
N
G
:
9’
−
1
1
/
8
"
DI
N
I
N
G
CE
I
L
I
N
G
:
9’
−
1
1
/
8
"
DI
N
I
N
G
CE
I
L
I
N
G
:
9’
−
1
1
/
8
"
PO
W
D
E
R
RO
O
M
PO
W
D
E
R
RO
O
M
PO
W
D
E
R
RO
O
M
1’
−
8
"
8’
−
8
"
1’
−
8
"
3’
−
6
"
3’
−
0
"
3’
−
0
"
3’
−
6
"
1’
−
8
"
8’
−
8
"
1’
−
8
"
3’
−
6
"
3’
−
0
"
3’
−
0
"
3’
−
4
7
/
8
"
2
1
/
4
"
3’
−
4
7
/
8
"
3’
−
0
"
3’
−
0
"
3’
−
6
"
1’
−
8
"
8’
−
8
"
1’ − 8"
PO
R
C
H
PORCH
PO
R
C
H
2
C
A
R
GA
R
A
G
E
2
C
A
R
GA
R
A
G
E
2
C
A
R
GA
R
A
G
E
ME
C
H
.
CH
A
S
E
MECH.CHASE
ME
C
H
.
CH
A
S
E
75
’
−
0
"
6
"
8
"
6
’
−
1
0
"
1
1
’
−
1
0
"
4
’
−
2
1
/
2
"
1
’
−
1
1
1
/
2
"
2
’
−
4
1
/
2
"
3
’
−
1
1
1
/
2
"
4
’
−
0
"
8
’
−
6
"
3
’
−
8
"
8
’
−
0
"
1
8
’
−
0
"
2
2
’
−
6
"
75
’
−
0
"
4 2
12
’
−
6
"
12
’
−
4
7
/
8
"
2
1
/
4
"
12
’
−
4
7
/
8
"
12
’
−
4
7
/
8
"
2
1
/
4
"
12
’
−
4
7
/
8
"
12
’
−
6
"
SL
O
P
E
D
W
A
L
L
W/
O
P
E
N
RA
I
L
I
N
G
SL
O
P
E
D
W
A
L
L
W/
O
P
E
N
RA
I
L
I
N
G
SL
O
P
E
D
W
A
L
L
W/
O
P
E
N
RA
I
L
I
N
G
4
8
’
−
6
"
2−
−
1
0
0
3−
1
0
0
2−
1
0
2
3−
1
0
2
1
−
1
0
1
3−
1
0
6
3−
1
0
5
3
−
1
0
4
CR
A
W
L
S
P
A
C
E
AC
C
E
S
S
30
"
x
2
2
"
M
I
N
.
CR
A
W
L
S
P
A
C
E
AC
C
E
S
S
30
"
x
2
2
"
M
I
N
.
CR
A
W
L
S
P
A
C
E
AC
C
E
S
S
30
"
x
2
2
"
M
I
N
.
1−
1
0
6
1−
1
0
5
2−
1
0
6
2−
1
0
5
1−104
2
−
1
0
4
3−
1
0
3
1−103
2−
1
0
3
6’
−
3
"
5’
−
9
"
4
’
−
8
"
2
’
−
1
0
"
6’ − 3"
5’
−
9
"
4
’
−
8
"
2
’
−
1
0
"
6’
−
3
"
5’
−
9
"
8
"
4
’
−
0
"
2
’
−
1
0
"
METERS
UN
I
T
1
UN
I
T
2
UN
I
T
3
1
A3
.
0
1
2
’
−
0
"
2
’
−
0
"
2
−
1
0
1
3
−
1
0
1
1
10
8
12
9
11
6
5
7
3
4
2
1
1
’
−
1
0
"
4
’
−
2
1
/
2
"
1
’
−
1
1
1
/
2
"
7
’
−
3
"
7
’
−
3
"
7
’
−
3
"
4
’
−
0
1
/
2
"
4
’
−
0
1
/
2
"
3
’
−
3
"
3
’
−
3
"
3
’
−
3
"
7’
−
7
"
7’ − 7"
FI
R
O
U
T
W
A
L
L
TO
B
E
F
L
U
S
H
W/
E
X
T
E
R
I
O
R
WA
L
L
7’
−
7
"
TH
I
C
K
E
N
E
D
WA
L
L
,
R
E
F
.
TO
P
L
A
N
NO
T
E
#
1
2
TH
I
C
K
E
N
E
D
WA
L
L
S
,
R
E
F
.
TO
P
L
A
N
NO
T
E
#
1
2
THICKENED WALL, REF. TO PLAN NOTE #12THICKENED WALLS, REF. TO PLAN NOTE #12
4
A5
.
0
1
6
A5
.
0
1
dzyn2architectscopyright 2018 dzyn2 architects, pllc drawings shall not be modified, copied, or used for purposes other than their intended use, without prior written consent from dzyn2 architects, pllc verify scale noted on drawings, as size reduction will affect scale of drawings REV:PROJECT NAME:Michael E. Pentecost, AIA P.O. Box 10866 Bozeman, mt. 59719 Ph −406 −586 −5896 Fax −406 −566 −5782ADDRESS:OWNER:LEGAL:A1.01MAIN LEVEL PLAN2310, 2320, 2338 GALLATIN GREEN BLVD BAXTER MEADOWS GALLATIN GREEN TRIPLEX − BLDG. 2 DESIGN REVIEWDUCK CREEK, LLC & TJ HOLDINGS, LLC BAXTER MEADOWS SUB., BLOCK14, LOTS 3 & 4, PHASE 2C 8−20−18 TRIPLEXAREA SCHEDULE NAME AREA UNIT 1 GARAGE 560 SF UNIT 1 MAIN LEVEL 554 SF UNIT 1 PORCH 90 SF UNIT 1 UPPER LEVEL 993 SF UNIT 2 GARAGE 557 SF UNIT 2 MAIN LEVEL 554 SF UNIT 2 PORCH 90 SF UNIT 2 UPPER LEVEL 990 SF UNIT 3 GARAGE 560 SF UNIT 3 MAIN LEVEL 554 SF UNIT 3 PORCH 90 SF UNIT 3 UPPER LEVEL 993 SF
1/
4
"
=
1
’
−
0
"
1
MA
I
N
L
E
V
E
L
P
L
A
N
PLAN NOTES:1. ALL WALLS AT THE MAIN LEVEL ARE 9’−1 1/8", U.N.O. ALL WALLS AT THE UPPER LEVEL ARE 8’−1 1/8", U.N.O.2. ALL DIMENSIONS SHOWN ARE TO FACE OF FRAMING.3. ALL WINDOWS TO BE TAPE SEALED AND FOAM FILLED SPACE BETWEEN WINDOW AND FRAMING.4. PROVIDE 1−1/2" GRIPPABLE HANDRAIL 34" ABOVE NOSING AT ALL STAIRS WITH MORE THAN ONE RISER 5. ALL INTERIOR DOORS ARE TO BE CENTERED IN OPENINGS OR LOCATED AS DIMENSIONED.6. PROVIDE 1/2" TYPE X GYP BOARD AT COMMON WALLS AND 5/8" TYPE X GYP AT CEILING AND UNDER STAIR.7. ALL WINDOW HEAD HEIGHTS ARE AS NOTED, REFER TO WINDOW SCHEDULE.8. PROVIDE EXHAUST VENT FOR WATER HEATER OF CPVC OR OTHER HIGH TEMPERATURE MATERIAL AS REQ. BY MANUFACTURER.9. ALL WATER HEATERS WITH PAN & STRAP.10. IF MECHANICAL ROOM IS ACCESSED FROM GARAGE, WATER HEATER SHALL BE 18" ABOVE GARAGE FLOOR ON METAL STANDS W/ SECURING STRAPS.11. DOOR AT GARAGE/HOUSE COMMON WALL TO BE SELF CLOSING AND RATED 20 MINUTES.12. AT THICKENED WALLS, PROVIDE 2x10 FRAMING AT 16" O.C. W/ 9−1/2" BATT INSULATION AND /16" OSB SHEATHING, TYVEK AND SIDING IN DICATED ON ELEVATIONS.13. STRUCTURE MUST COMPLY WITH 2012 INTERNATIONAL ENERGY CONSERVATION CODE AND IBC 2012 BUILDING CODE.