Loading...
HomeMy WebLinkAboutSht A2.4 - Warbler Sections 05-24-19 w�stio A r c�+ • 30 YR.ASPHALT SHINGLES(PRE-FINISHED METAL ROOFING ATSOME LOCATIONS,SEE j TR Pi NP. C"1 ."7 E RS ON "1 ELEVATIONS) • SYNTHEnCROOFINGUNDERLAYMENTover ARC CT 5/8'OSB Over rn 2 Q • ENGINEERED WOODTRHIEL w/12'ENERGY ROMTHEINSIDE o.c.w/XTERIO INSULATION LLA • PROVIDE ICE&WATER SHIELD2FEET FROM THE INSIDE OF THE EXTERIOR WALL AT ALL 9� •L� EAVES&18"EACH SIDE OF EACH VALLEY E' O M0 '- BAFFLE TO MAINTAIN I"MIN.CLEAR VENT@ UNDERSIDE OF SHEATHING 2X BLOCKING EA TRUSS BAY, HOLD DOWN 2"FOR ATTIC I VENTILATION--J 1x6TOP CHORD PRE-FINISHED METAL DRIP 1 Xe MIRATEC FASCIA W/ 1 X4 SHADOW BOARD,TYP. a SEISMIC CLIP(SIMPSON HI,H2.5A, w or SIM)AT EA TRUSS-TYP Z z � (2)2%10 HEADERS,U.N.O. Lli m J 1l2'GWBover p-0" 30'0" 2'-0' ui Q c Q W LD co VAPOR BARRIER se 5 U O N WINDOW,SEE FLOOR PLAN FOR TYPE&OPERATION, OctLLJ Z Q OWNER TO SELECT WINDOW BRAND&MATERIALS � J OO q n $ J d e. O 3/4"PLYWOOD SU8FLOOR GLUED&NAILED TO 11-7/8'I-JOISTS @ 16"o.c:TYP tj SPRAY FOAM URETHANE INSULATION AT PREFABRICATED ROOF TRUSSES RIM JOISTS,TYPICAL ALL FLOORS,31/4" ui MAX.THICKNESS -- — T.O.UPPER WAL 1PE-2AL 11 7/8"AIM BOARD NOTE:FOR MATERIALS AND ASSEMBLIES,SEE DEWL NAM BED 2 0-2 X 11-3 BED 1 - 1212X10 HEADERS,U.N.O. 11-2%11-9 WINDOWTRIM-TYP UPPER LEVEL /l — 1111-1 3/4" 1 r WALL 1�•�•l, 1/2"GWB 110'-11/e" 9 S a , 8 w Q/ E m g WINDOW,SEE FLOOR PLAN FOR TYPE&OPERATION, KITCHEN 1 CAR GARAGE W t 13-9X 11-0 11-0X23-6 LL w OWNER TO SELECT WINDOWBRAND&MATERIALS MAIN LEVEL $ 1/2'GWB over 100')) S VAPOR BARRIER _ w $ SIDI14G(SEE EXT.ELEVATIONS)on —III III III III—III—III III III III 7v `q AIRINFILTRATION BARRIER on —_III— CRAWL SPACE -I I -I I —I I I—I I I—III I—I I I-I 1••+•—1 e /2'OSB SHEATHING on -III III -III-III-III-III- III-III T Q �r R1 IWN ULA ONS @ 16'o.c wl - - T.O.FOOTING n `/ 25 — — — — — V _ =1t1 t 1=1 I_I -1 1-1 I-1 1=111-1 1=1 -1 -1 II 11=1 -1 t d 3/4'PLYWOOD SUBfL00fl GLUED&NAILED — T011-7/8"I-JOISTS @ 16"o.c-TYP u 2X P.T.SILL PLATE W/SILL SEAL n BUILDINGSECTION IT dIl.ANCHOR BOLT w/3x3x1/4 PLATE :%?� WASHER @48"o.c:TYP(BOLTS TO BE LOCATED NOT MORE THAN 12"OR LESS THAN W 'I� 7 BOLT DIAMETERS FROM PLATE SECnONS} .•T'. I-III—III_ EMBED 7"MIN •I" — BTNMINOUS DAMPPROOFING TO GRADE C�C _ I I-_ 6'CONC.WALLw/44HORI2.& C ,I.. I— — VERT.@18"o.c-TYP R-15 MIN.INSULATION w/CONT.VAPOR W F _ BARRIER NOTE: d ��.1 I-III—III VERTICAL 1 "FROM TOP OF WALL. X4 REBAA @ 48'O.C.UP T .p III—III- FOOTING TO WALL JOINT REINFORCEMENT:x4 REBAR@24' 1? — EXTENDS UP INTO STEM WALL I4'MIN. 'I — EVERY OTHER JOINT REINFORCEMENT BAR MAY BE F^ III—III REPLACED BY THE LONGER WALL VERTICAL REBAR, VAPOR BARRIER, I' _ RESULTING IN VERFS EVERY 24'FOR PONT REINFORCEMENT. OVERLAP JOINTS 6' 'j i—_ I —_ MAINTAIN SUPPORT AND COVER PER IRC R404.11.3.7A. MIN.&SEAL,EXTEND •t:.• REINFORCEMENTS HALL BE SECURED IN PLACE TO PREVENT UPWALL6'AND _'; I:. - —III- DISPLACEMENT DURING CONCRETE PLACEMENT, ATTACH TO WALL ..0,:1' d; 16'x8"CONC FOOTING w/121 ft4 CONT.-TYP,VERIFY SECTIONS —III- WITH GEOTECHNICAL REPORT —III—III COMPACTED STRUCTURAL FILL UNDER FOOTINGS PEP GEOTECHNICAL RECOMMENDATIONS&REQUIREMENTS A WALL SECTION-2-STORY L 3/4"_1'-0" A2s4 1