Loading...
HomeMy WebLinkAboutSht A2.1 - Warbler 1st & 2nd Floor Plans 05-24-19 ?SRO ARc� t� GENERAL NOTES a TRP M ER ON 1 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND JOB SITE ARC CT CONDITIONS BEFORE COMMENCING WORK AND SHALL REPORT ANY N 9 Q DISCREPANCIES TO THE ARCHITECT. 2. GENERAL CONTRACTOR TO COORDINATE ARCHITECTURAL DRAWINGS WTFH MECHANICAL,ELECTRICAL,AND PLUMBING. APPLICABLE CODES: 2012 INTERNATIONAL RESIDENTIAL CODE 2012 UNIFORM PLUMBING CODE 2012 INTERNATIONAL MECHANICAL CODE 2014 NATIONAL ELECTRIC CODE 2012 INTERNATIONAL FUEL GAS CODEui 2012 INTERNATIONAL ENERGY CONSERVATION CODE ui DESIGN CRITERIA 30'-0" SEISMIC ZONE DO 6'-6' T-10" 5'-1T 9-10' 115MPHWIND PLAN NOTES Q UNCOVERED FRE RESISTANTCONSTRUCTION REOUIREMENTS B CONCRETE PATIO DOORISI BETWEEN GARAGE&HOUSE SHALL BE 20-MINUTE&EQUIPPED S1.2 16 O X 9-0 WITH A SELF-CLOSING DEVICE. ' w 30'-0' 2. INSTALL 1/2"GWB@ WALLS&UNDER-STAIR SURFACE IN ENCLOSED Z ACCESSIBLE SPACE UNDER STAIRS 6-8. 4'-0" 3'-8' 4'-0' 3' 11' 2'-S' 5'-4"1 3. 1/2"GWB SHALL BE INSTALLED ON ALL WALLS SEPARATING THE N} 42 X42 SLIDE GARAGE FROM THE DWELLJNG. LL V 4. WHERE HABITABLE ROOMS ARE ABOVE A GARAGE,APPLY 5/8'TYPE'X' W lJ pp (T-6"I HEADR GA ON GARAGE CEILING&1/2"GWB ON WALLS SUPPORTING FLOOR Q Q A80VE 72'x 60' '0'X30' .- Rz 5. FOAM INSULATION SHALL BE SEPARATED FROM THE INTERIOR OF A o [r w SINGLE HUNG 28'xnu AWNING �`1{ --J �I �Yy- �•wJ CpP•C`JSi O F� BUILDING BY AN APPROVEDTHERMAL BARRIER OF MINIMUM I/21NCH O FV EGRESS W.I.C. (6'-71"1 HEAD l`yl ll "�, LL ;,p�QC 3� GWB OR A MATERIAL THAT IS TESTED IN ACCORDANCE NFPA 275. w Z C) (6'-11")HEAD - 3-0X49 r '� POWDER , g1 m 6. &OVIDE FIRE RIZOTALLY CKING AT LLYNOT AT EXCEEDING FT. FLOOR LEVELS J [105 co I 14CKING � 14,____� &HORIZONTALLY AT INTERVALS NOTE%CEEDING 10 FT. C 5-0%5-0 - rC BATH KITCHEN MECHANICAL EGRESS WINDOWS J yyyF'''q a. ❑ 3C x 80"9-4 X 5-0 BED 2 _C7 6-11 X 8-6 �0 13-9 X 11-0 30"x 80" ALL SLEEPING ROOMS SHALL HAVE A MEANS Of EGRESS HLLMDIRECTLY TO THE 10.2 X 11-3 32'x 80" - POCKET REQU REMENTSOUTSIDE VIA A OF IK 012OR OR 1 SEC ION R3101W.EGRESS WINDOWS SHALL MEET THE _ `---J MECHANICAL O n ^ e L2�11�10k30"x80"_ 7-OLINEN ISLAND 1. CONTRACO1/2'CONFIB GA,GALTYPE OFWEEL PA DRAINETtj4.3X5-5HEATER INII/2'DEEP 24 GA.GALVANIZED STEEL PAN DRAINEDw/ _ 3/4'INDIRECT WASTE PIPE.WATER HEATERS SHALL BE ANCHORED DN .. 3 ——J a OR STRAPPED TO PREVENT HORIZONTAL MOVEMENT 30'x BO" 51.2 b 2. ELEVATE WATER HEATER 18"MINIMUM ABOVE GARAGE SLAB TO ANY UJI _8'CLG. — 60" AO" zr b �$ `------ a ELEMENT OR SWITCH THAT MAY SPARK a ° -- x pANTgy - 3. A PERMANENT CRAWL SPACE LADDER OR ATTIC SPACE PULL DOWN w - LADDER IS TO BE INSTALLED TO ACCESS THE HEATING UNIT OR 3 13'-101/2' ��_4'-1__ 11'-01/2' � BOILER. 30"x80" 4. THE MAXIMUM CLEAR TRAVEL PATH FROM THE CRAWL SPACE OR 512 r, BATH � � Q ATTIC ACCESS OPENING TO THE HEATING UNIT OR BOILER IS 20 FEET. b - 10-2X5-8 b $, � ------ q 5. PROVIDE LIGHT FIXTURE CONTROLLED BY A SWITCH LOCATED AT o > W `}'F ------ 1 CAR GARAGE ?,A = '9' THE CRAWL SPACE ACCESS HATCH&A RECEPTACLE OUTLET SHALL ,,, REINSTALLED AT NEAR THE FURNACE = 11-0%23-6 SAFEtt GLAZING AEQUR EMENTS O BCLG. BED TFMPERGLAZING AT LOCATIONS SPECIFIED IN IRC 2012 R308.4 11-2X71-9 -- HANDRAIL ON AT LEAST ONE SIDE OF THE STAIRS. m , ^ 34-38'IN HEIGHT WITH A 1 e LIVING/DINING GRIPPING SURFACE PER 1 13-9X180 k _"""-_______________ ENERGY REQUIREMENTS Er�I _-- 721X24' b 3 ` FIXED - ^ - (6'-1 1 HEAD '^ m 2012 INTERNATIONAL ENERGY CONSERVATION CODE ry o= BED � M MONTANA CLIMATE ZONE 6B J°x 13-11 X 11-5 ----- - ` ^ INSULATION&FENESTRATION REQUIRMENTS BY COMPONENT �' 1° UP CEILING FLAT; FLAT Rig F g I VAULTED R-38 72'x 60" WALLS; BAASSEMENTSD R-19CAVITY/R-15 CONT. SINGLE HUNG I 72"x60' ��� 9'-0"W%8'-0"H EGRESS SINGLE HUNG v OVERHEAD DOOR CRAWLS A-19 CAVltt/A-iSCONT. ' t t.1 HEAD (7'-6')HEADLL J k' FLOORS: OVER UNHEATED SPACES R-30 PERIMETER SLAB FOR 4 FT. R-10 e -- EXTERIOR DOORS R-3 WINDOWS NFRC UNIT RAT114G 8 5'-3' 9'-3' 5'-6' 6'-0" WATER 32 HEATER ENERGY FACTOR RATING 0.58 T�1 912 LORAG i HEATING SYSTEM ENERGY EFFICIENCYRATING 78%T-6' T-p 1'-0' S'-9" 5'-9' 1? COVERED PORCH (AFUE FOR GAS;HSPF HEAT PUMP) W % 6' 14-6X 5-0 30'-0" ----ROOF BEAM ABOVE FRAMING NOTES 4'-0' 1tl-6' 4'-0" 11'-6' 1. USE 13)2X6 POSTS U.N.O. P� 30,0, 2. USE 12)2X10 HEADERS U.N.O. 2ND FLOOR PLAN 1 ST FLOOR PLAN 1/4"=1'0" 1 1/4"=i'O" LLI V1 H W d FLOOR AREAS 15TFLOOR GROSS: 643 SF GROSS 2NDFLOOR GROSS: 790 SF GROSS TOTALGROSSAREA: 1,433 SFGROSS 1 ST FLOOR LIVEABLE: 526 SF NET -- 2NDFLOORLIVEABLE; 114 SF NET FLOOR LIVEABLE: 734 SF NET TOTAL LIVEABLE AREA: 1,260 SF NET 1ST&2ND GARAGE 260 SFNET FLOOR PLANS a All MAY 24,2019