HomeMy WebLinkAboutSht A2.1 - Heron 1st & 2nd Floor Plans 05-23-19 ARC,
5 �
GENERAL NOTES
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND JOB SITE ♦ TREVORP.M. n
CONDITIONS BEFORE COMMENCING WORK AND SHALL REPORT ANY -j PIERSON ^1
DISCREPANCIES TO THE ARCHITECT, ARC CT
2. GENERAL CONTRAC70A TO COORDINATE ARCHITECTURAL N Q
DRAWINGS WITH MECHANICAL,ELECTRICAL,AND PLUMBING.
APPLICABLE CODES•
20;2 INTERNATIONAL RESIDENTIAL CODE O MOB
202 UNIFORM PLUMBING CODE
20121NTERNATIONAL MECHANICAL CODE
2014 NATIONAL ELECTRIC CODE
30'-0" 20121NTERNATIONAL FUEL GAS CODE
2012INTERNATIONAL ENERGY CONSERVATION CODE
DESIGN CRITERIA
SEISMIC ZONE DO O
115 MPH WIND
PLAN NOTES W
30,-0" FIRE RESISTANT CONSTRUCTO REQUIREMENTS
CONCRETE PATIO 1. DOOR(S)BETWEEN GARAGE&HOUSE SHALL BE 20-MINUTE&EQUIPPED
5'-4" 2'-5" 3'-11" 1'-10, 4'-2' 2'-2- 4'-10' 5 4" b 18-0X 10-0 b
_ WITH ASELF-CLOSING DEVICE.
11 2. INSTALL I/2'GWB@ WALLS&UNDER-STAIR SURFACE IN ENCLOSED W
512 9'-10, 6'-4' 4'-7' 5'-5" 3'-10'Q ACCESSIBLE SPACE UNDER STAIRS z
- 3. 112"GWBSHALLBE INSTALLED ON ALL WALLS SEPARATING THE Q
GARAGEFROM INE DWELLING. J xp
-- - 4. WHERE HABITABLE ROOMS ARE ABOVE A GARAGE APPLY 5/8'TYPE'X' W V'
36"X24" 24'X24" 72"x6C' GWBON GARAGE CEILING&1/2'GWB ON WALLS SUPPORTING FLOOR L7 m Z
72'x 96" 36,X 60, ABOVE Q ZD Q
AWNING v AWNING SINGLE HUNG -- 'y SLIDER SINGLE HUNG 5. FOAM INSULATION SHALL BE SEPARATED FROM THE INTERIOR OF A
(6'-11'1 HEAD 16'-11'1 HEAD 16'-11')HEAD ,� O C�L(`'S1 ❑ FULL LITE I8-0"I HEAD BUILDING BY AN gPPROVEDTHERMAL BARRIER OF MINIMUM 1/21NCH Q W
1 LAUNDRY hP,P' o TEMPERED GWB OR MATERIAL ISTESTED IN ACCORDANCE NFPA 275 U 0 IV
Y'�Y POWDER �+ FUR DOWN CEILING IN 6, PROVIDE FIRE BLOCKING VERTICALLY AT THE CEILING AND FLOOR LEVELS W Z O
b 6-0 x 5-2
N
MECH.-4X5- x�-- o❑ 5-7 X 5-0 POWDER ROOM AS &HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FT. m
9-4 X 5-0 36'x 80" AEQ'D FOR DUCT MOAN
b o BATH X7
9A 30"x 80' EGRESS WINDOW5
32'x Bo'- OFFICE 2aMIN. O
7-0X9-0 - POCKET - -- ALL SLEEPING ROOMS SHALL HAVE A MEANS OF EGRESS DIRECTLY TO THE
POCKET 9-B X 11-3
RN DOOR OPTION LLTCTAICAL PANEL OUTSIDE VIA A DOOR OR WINDOW.EGRESS WINDOWS SHALL MEETTHE
32'x80" S'-0" 4'-10' 1'-8' T-2' -01/2" 13'-41/2' v REQUIREMENTSOF IRC 2012 SECTION R310.1
3'-11" 4'-4" 3'.10' 9-8112" 'v
�LINEN
80" M_Fru.ANICAL
$ 20MIN. 1. CONTRACTOR TO CONFIRM SIZE&TYPE OF WATER HEATER,SET
� DN 'd HEATERINI IR"DEEP 24 GA.GALVANIZED STEEL PAN DRAINED w/ ki
POCKET ' -1e- _-- --. LIVING/DINING INDIRECT WASTE PIPE.WATER HEATERS SHALL BEANCHORED
_ 134 X 230 OR STRAPPED TO PREVENT HORIZONTAL MOVEMENT
n<ii o 12 a ,"STORAGE ><� 2. ELEVATE WATER HEATER IB'MINIMUMABOVE GARAGE SLAB TO ANY
SL2 W.I.C. „+ UNDER STAIR
ELEMENTOR SWITCH THAT MAY SPARK
b a 7-0 X 4-0 c I m 3. A PERMANENT CRAWL SPACE LADDER OR ATTIC SPACE PULL DOWN
t3 } LADDER IS TO BE INSTALLED TO ACCESS THE HEATING UNIT OR
_ 81CLG. _ 1 j 51.2 w. _-_____- Xo=
v F BOILER.
_ _ 4. THE MAXIMUM CLEAR TRAVEL PATH FROM THE CRAWL SPACE OR
9�X NB _ ______ ATTIC ACCESS OPENING TO THE HEATING UNIT OR BOILER IS 20 FEET.
b 5. PROVIDE LIGHT FIXTURE CONTROLLED BY A SWITCH LOCATED AT
t, 30"x 80' -' o THE CRAWL SPACE ACCESS HATCH&A RECEPTACLE OUTLET SHALL
8'CL O _ ti n s GARAGE -------- �, ow b m b BE INSTALLED AT OR NEAR THE FURNACE _
11-0 X 23-6
c, bLL a SAFEttGLAZING REQUIREMENTS
wb 1.TEMPER GLAZING AT LOCATIONS SPECIFED IN IRC 2012 A308.4
x 8_ BED 1 b 7-61/T T-3-
11-2X 11-3 > x z
3 7 ENERGY REQUIREMENTS Q
o
BED d ry ®' 2012 INTERNATIONAL ENERGY CONSERVATION CODE
72"x80" 13.6X 11-4 x8_ 4'-0-
SLIDER '< x�^ MONTANA CLIMATE ZONE 68
TEMPERED $
e w INSULATION BFENESTMTION REOUIRMENTS BY COMPONENT
F I UP KITCHEN I
jI 13-4X 11-0 CEILING FLAT: FLAT R49
36%60' 36')g60" 36'X60' HANDRAIL ON AT LEAST VAULTED R-38
b COVERED DECK SINGLE HUNG SINGLE UNG SINGLE HUNG ONE SIDE OF THE STAIRS
LOV-ERHWEAXD
'-0'H WALLS: ABOVEGRADE A-21
11-6X4-0 EGRESS EGR SS EGRESS 34"-38"IN HEIGHT WTMA BASEMENTS R-19 CAVITY/A-15 CONT.
6%8 DF 41 ABOVE 16'-1I'IHEADI6'-11'HEAD 16'-11'I HEAD DOOR GAIPPINGSURFACE PER ��-
R311.7.G � CRAWL SPACE R-19 CAVITY/R-15 CONT. �
FLOORS: OVER UNHEATED SPACES R-30 rT,
11 A O O EXTERIOR DOORS PERIMETER SLAB FORT FT. A3
S 1.2 WINDOWS NFAC UNIT RATING U-0.32 �!y
b WATER HEATER ENERGY FACTOR RATING 705
8
-6" 4'-11' 7" 4'•6' 3'-31/4' 3'-6' 3'-6" 3'-83/4" �;� HEATING SYSTEM ENERGY EFFICIENCY RATING 78%
11'-6' 18'•6'
' Z. T l C----I- (AFUE FOR GAS;HSDF HEAT PUMP) lJ U
39-T LL V z_4 1
1
5'6" WX54` 7-3'_ �4
SLIDER
COVERED CONCRETE I&'-01HEAD
1
b F�1
PORCH ham"166 X 6-0 h�"h
2N9
FLOOR PLAN
ROOF BEAM ABOVE
6-0' S'-6' 4'-0'
1V-6"
3tl-0'
W
N
F—
W
1 1 ST FLOOR PLAN �
FLOOR AREAS
IST FLOORGAOSS: 690 SF GROSS 1ST&2ND
2NDFLOORGROSS; B10 SF GROSS
TDTALGROSSAREA: 1,500 SF GROSS FLOOR PLAN
1ST FLOOR LIVEABLE 6" IF NET
2ND FLOOR LIVEABLE: 755 SF NET
TOTAL LIVEABLE AREA: 1,357 SF NET
A
GARAGE: 257 SF NET
All
MAY 23,2019