HomeMy WebLinkAboutC2.0-MSP MASTER SITE GRADING & UTILITY PLAN - 04 03 2019 MARK A.
CHANDLER
No. 951SES o?
CONNECT PROPOSED
CONNECT NEW UTILITIES TO EXISITNG SIDEWALK TO EXISTING TRAIL 911MEER \�
JUNCTION CAN.CONTRACTOR TO
N COORDINATE UTILITY HOOKUP WITH INSTALL(1)STEP WITH (2)
UTILITY COMPANY. 6"RISES AND HANDRAIL.
AINDER OF TRACT 2A, DRAINAGE AREA 2 CONTECH STORMWATER CHAMBERS SEE DETAIL Sheet 2 Of 3
0
COS NO. 2202A III INSTALL CONCRETE SLAB DRAIN 8/C3.0.REQUIRED STORAGE VOLUME 1,099 CF.SYSTEM PROVIDED
' �p .75�TO STER LE SEE SHEET A402
FOR DUMPSTER ENCLOSURE DETAILS STORAGE VOLUME 1,172 CF.CONTRACTOR SHALL EXCAVATE TO
- NA'E
GRAVELS AND BACK FILL WITH WELL DRAINING PIT RUN - - - - C m E
"COMPACT PARKING
INSTALL PRIVACY FENCE AND DENSE LANDSCAPING FOR umi m
DUMPSTER ENCLOSURE SCREENING.SEE ARCH PLANS FOR ONLY SIGNS OF c
FENCE DETAILS AND LANDSCAPE PLANS FOR PLANTING DETAILS. EACH COMPACT SPACE .W
' 24'ACCESS RISER AND D 1 STALL CONNECT PROPOSED I I
PER C3.0 AND i6/C3.0. SIDEWALK TO EXISTING TRAIL
BLI PAR K_E (� m
CONNECT TO EXISTING 4"SANITARY - • -
SEWER SERVICE STUB(TYP.OF 2) ,s 3J( [589'0�3'Ef (O INSTALL(4)STEPS WITH(5)6" I ` C o Scale In Feet w 33 I 6 S .47 p 1'17'(R) '`j I m o „
20 0 20 2 Tn 1.1.
KIMBERWICKE STREET INSTALL 24' RESIDENTIAL "°E �E UGe UGe UGE (SW) C
6 0 6 INSTALL 6"X8"TAPPING SLEEVE AND DRIVE APPROACH PER - MECHANICAL SCREENING FENCE,SEE I c
DETAIL 6/C3.0 �' ARCH PLANS FOR FENCE DETAILS. N
Sole In Meters THRUST BLOCK SEE APPROVED WATER ss '-
MAN I EXTENSION PLANS FOR DETAILS C
n is ;4 Sy11 1,31 �m
s `s, C rM Contour lnte ¢la: 1 Foot (ENTRANCE)
W<'ss_ R, � �„ (.t 1 ( ) �a
4701.32 I
�?MINI M 5.5 M"8 ss 7. (3.31)
E ARATION 2 ST A�H 2(4"X3") ,L yB ( ) B
--� ENTRANCE
1)(TBC) < TBC:4701.66 ,4 I B
BI RACK SEE AR, a. L S:469 6(1 ' tik4
A403 BOR DETAI ,4 a, ti� 4703.32
- C STALL) i) "WAT c.o. ,y. c \
ucE 3 D 1 4"FIRE SERVICE PER <"s5 I TFt
INSTALL(1)2"WATER SERVICE PROVED FIRE LINE PLANS (3.31) F.F.BUILELEVDING VARIES
SAWCUT AND DEMO AREA OF EXISTING \ ?46 RAMP HASE 1 (ENTRANCE)- - I ^AND(1)4"FIRE SERVICE PER aT
ASPHALT,CURB,AND SIDEWALK. APPROVED FIRE LINE PLANS ��� Sa L{�-
- 2j2) r P ASE 2
F.F.ELEV. =4703.09 ( O) MOUNTABLE CU!B F.F.ELEV.=4703.32 I I
(3.08)
MECHANICAL SCREENING FENCE.SEE (ENTRANCE) I ADA RAMP `� ECORATIVE OSSWALK CONCR (3.31)
DT 4 LOT 5 ARCH PLANS FOR FENCE DETAILS. CATC URB (ENTRANCE)
3.05)( C) V
INSTALL(11.5'OF NE_�I'OIE
EWALK: J ?'J
ACROSS BOULEVARD.Mq� XISTINP
J TOP S OF CURB ADEWALK (3 29) LI HC P KIN SIGN w (ENTRANCE) -
ELEVATION (ENTRANCE) PER D AI$�..,�2& 13 Rl
IN
4'X4'TREE GRATE PER ?9 ? m w s
DETAIL 11/C3.0(TYP.OF 4). 6 3.19)( Q) STALL(1_)2 WATER SERVI E k' N) 5Y1 6)(SW)
/ TREE SPECIES PER LANDSCAPE PLAN. (� F.F.ELEV. 4703.30 ND(1)4" E SERVICE P R T 3 l I
(3,29) uPPROVED FI LINE PLANS (3.26)(TBC) °
(ENTRANCE) (3.36) .0 73 271' 1.48 I F.61
\ m CONCRETE VALLEY G R PER (ENTRANCE) 4'4 [I]
I DETAIL 10/C3.0(TYP OF 2) ADA RAMP MECHANICAL SCREENING 1.6 67
_ Z J 3_ BUILDING A FENCE.SEE ARCH PLANS s
F.F. ELEV.=VARIES -_ 3.19)(7IBC) M ABLE CURB (3.36) FOR FENCE DETAILS.
CONNECT BUILDING A PLUMBING
TO EXISTING 4"SANITARY L (ENTRANCE) s CONNECT PROPOSED I
�/ vJ SEWER SERVICE STUB - SIBEWALIL.10 EXISTING TRRRggqIIIL
(3A [[SPILL CURB
(ENTRANCE) r1
\ 1 ABANDON EXISTING WATER SERVICE AT [L� F.F.ELEV. =4703.50 3 o o / / /
MAIN PER CITY OF BOZEMAN=ANDARD J HARDLINE DOWNSPOUTS TOGETHER,
y m ' 3 (3.49) 9 ! 2.54) (3.36) a a / DISCHARGE TO EXISTING STORM POND.
LOT F I -m (� - (ENTRANCE) (ENTRANCE) I may/
vJ __ III I W
,S;y P POSED FIRE HY RANT TO
''/^� INSTALLED P R PPROVED
v! w n W TER MAIN EX N ION PLANS
- - - ��
3.36)
- - I III I
(
(3.70)
I- o = Z ss� (ENTRANCE) 3.60) a(BC T (ENTRANCE)l
®Q (TB 7 �1 BUILDING C n� OPEN SP F.F.ELEV. -4703.71 I�} T., PUBLIC AC�ELSS
SAWCUT AND DEMO AREA 0 �I,,�TTING Q� __ 6y,090 Sq.Ft. F.F.ELEV.=4703.37 an / I
ASPHALT,CURB,AND WALK. J�^ (3.70) 1 3 Acres \ /
LL Q (ENTRANCE) (3.36) y I I I I z
LOT 7 00 W IN CC IN ASSON PER PLAN PROVED WO RE AST MH 1 (24"36•(ENTRANCE) O
1�1
F- E 3.81) C) TBC:4702.52
x (3.91) F.F.ELEV.=4703.92 1 FL OUT(SE):4 99. 0(12")
(ENTRANCE) MOU BILE CUR (ENTTRANCE)l I. III I O
- TCH CURB Ll I ' I FFFSIII
2.25
INSTALL 8"X8"TAPPING SLEEVE AND Rry� �Rl
MAIN
BLOCK SEE APPROVED WATER----____ O by P ASE 2 MAIN EXTENSION PLANS FOR DETAILS � �ti' (3.36)
m 1 .0'MIN 15 ',1!- (ENTRANCE) III �I, rTl
4w
w
LOT 8 g.. g.. SE ERATIONg..w "�
INSTAL (1)2"WATER SERVICE (3 07 6 (3.36)
INSTALL NEW 4"SANITARY SEWER Rl L AND(1 4"FIRE SERVICE PER '¢y o-\ (ENTRANCE)
SERVICE.CONNECT TO EXISTING-
SANITARY
SANITARY SEWER MAIN IN GALLATIN 5
GREEN BOULEVARD. r w
¢ (3.54) � (3.54) (3.54) (3.54) ( 4)
OF EKI�f(NG-CSP
(ENTRANCE) (ENTRANCE) (ENTRANCE) (ENTRANCE) J 29 / ^° .81
SAWCUT AND DEMO AREA O /
CURB,AND SIDEWALK.TRENCHES SHALL B
BACKFILLED WITH FLOWABLE FlLL. MATCH EXISTIN INSTALL 24'RESIDENTIAL /
ASPHALT THICKNESS WITH BITUMINOUS ASPHAL DRIVE APPROACH PER
PATCH,REPLACE ANY CURB AND SIDEWALK DAMAGE DETAIL 6/C3.0 / 3M4, U
f�URING CONSTRUCTION (TYP.OF 3 SAW CUT AREAS. I BUILDING B El E]
03.55 /
F.F.ELEV. =47 Oh /
/ a CONNECT PROPOSED
LOT 9
/ SIDEWALK TO EXISTING TWdL
24" CESS RISER AND MANHOLE INSTALL PER
DET LS 15/C3.0 AND 16/C3.0.
13&33 27031'17' .26 D GE AR 1 CONTECH STORMWATER CHAMBERS �O
sr (R) •60 S DETAIL /C3.0.REQUIRED STORAGE VO JME 1,535�
i ' F.SYS PROVIDED STORAGE VOLUME 1 76 CF.
NTRA R SHALL EXCAVATE TO NATIVE RAVELS
PUBLIC PARK D AI�
F MECHANICAL SCREENING FENCE.SEE CKFI WITH WELL DRAINING PIT RUN. /y�
I n O ARCH PLANS FOR FENCE DETAILS. -� /EXISTING TREE(TYP.) / � `�(/Q
- _Cl PUBLIC PARK E (TYP
PROPOSED TRANSFORMER/�wON / \
x 7'CONCRETE PAD .) / �r`� /S87.Le Date: 0410312019
ON CT NEW UTILITIES TO EXISITNG ry P V
Sf JUN ION CAN.CONTRACTOR TO / O ry
Oti I \ CO RDINATE UTILITY HOOKUP WITH Uj Q U LITY COMPANY. / QTQ' ���
LOT 1 0 MASTER SITE GRADING & UTILITY PLAN i i / �Q' CIO
C SCALE:1"=20' n` Q
gn128t