Loading...
HomeMy WebLinkAbout06-17-19 City Commission Packet Materials - A4. Lot 11 Gallatin Center Subsequent Minor Subdivision Preliminary PlatPage 1 of 14 17483, Staff Report for the Lot 11 Gallatin Center Minor Subdivision Public Hearing Date: Planning Board, June 4 2019 at 6:00 pm in the City Commission Room 121 N. Rouse Avenue, Bozeman, Montana City Commission, July 17, 2019 at 6:00 pm in the City Commission Room 121 N. Rouse Avenue, Bozeman, Montana Project Description: A development review application was submitted to the Department of Community Development requesting a second or subsequent minor subdivision from a tract of record (8.615 acres) to create two lots. Project Location: The property is zoned B-2 (Community Business District). The property is addressed as 3155 Cattail Street and is legally described as Lot 11, Phase 1, Gallatin Center Subdivision & PUD Phase 4, situated in Northeast One-Quarter (NE ¼), Section 35, TIS, R5E, P.M.M., City of Bozeman, Gallatin County, Montana. Recommendation: Approval with conditions and code requirements Recommended Motion: Having reviewed and considered the application materials, public comment, and all the information presented, I hereby adopt the findings presented in the staff report for application 17483 and move to approve the subdivision with conditions and subject to all applicable code provisions. Report Date: May 31, 2019 Staff Contact: Danielle Garber, Assistant Planner Griffin Nielsen, Development Review Engineer Agenda Item Type: Action (Quasi-judicial) EXECUTIVE SUMMARY Unresolved Issues 1) None Project Summary The applicant, Gallatin TR LP is proposing to subdivide the 8.615-acre lot 11 in phase 1 of phase 4 of the Gallatin Center Subdivision into two commercially zoned lots. This subdivision is bound on three sides by existing Gallatin Center Subdivision lots, Opportunity Subdivision is further to the south and North 19th to the east. Lot 11A on the corner of Max Avenue and Cattail Street is proposed to be 4.746 acres, and 11B to be 3.869 acres. Catron Creek runs along the west edge of the proposed 11A. A 100-foot wide stream corridor reviewed and approved with the original 416 17483 Staff Report – Lot 11 Gallatin Center Subdivision Page 2 of 14 subdivision will be maintained. No regulated activities are proposed in the watercourse setback or delineated wetlands with this application. All required right-of-way has been dedicated with the original subdivision. There are existing utility easements within the proposed lots and along the perimeter. A public water line easement containing an existing water main runs through lot 11B, and water and wastewater mains run through the northern portion of both lots. Mutual access between the lots is maintained through existing protective covenants. Cash-in-lieu of water rights for this subdivision will be deferred until future development per Section 38.410.130.C.5. The City of Bozeman Department of Community Development received a preliminary plat application on October 04, 2017, requesting a second or subsequent minor subdivision. The project was deemed inadequate for review and review halted until revised materials were provided. Revised materials were submitted on November 13, 2018 and the application was again deemed inadequate on December 19, 2018. Revised materials were received between January and March. The application was deemed inadequate on March 7, 2019. Revised materials were received between March and May. The application was deemed adequate on May 7, 2019 and review continued. The final decision for a second or subsequent minor subdivision must be made within 60 working days of the date it was deemed adequate, or in this case, by July 6, 2019. The City Commission is scheduled to review the preliminary plat and make a decision at their June 17, 2019 public hearing. The Planning Board considered this project at their June 4, 2019 meeting and voted 8-0 unanimously to recommend approval. Board discussion centered around nearby transportation infrastructure needs and regulatory timing with this project and future site development. A full video of the board meeting can be viewed here: https://media.avcaptureall.com/session.html?sessionid=9baabf69-49ea-47a5-bbc8- 396c63d1997b&prefilter=654,3835 Alternatives 1. Approval of the application with the recommended conditions; 2. Approval the application with modifications to the recommended conditions; 3. Denial of the application based on the Commission’s findings of non-compliance with the applicable criteria contained within the staff report; or 4. Open and continue the public hearing on the application, with specific direction to staff or the applicant to supply additional information or to address specific items. 417 17483 Staff Report – Lot 11 Gallatin Center Subdivision Page 3 of 14 TABLE OF CONTENTS EXECUTIVE SUMMARY ............................................................................................................ 1 Unresolved Issues ............................................................................................................... 1 Project Summary ................................................................................................................. 1 Alternatives ......................................................................................................................... 2 SECTION 1 - MAP SERIES .......................................................................................................... 4 SECTION 2 - RECOMMENDED CONDITIONS OF APPROVAL ............................................ 6 SECTION 3 - CODE REQUIREMENTS REQUIRING PLAT CORRECTIONS ........................ 7 SECTION 4 - RECOMMENDATIONS AND FUTURE ACTIONS ............................................ 8 SECTION 5 - STAFF ANALYSIS AND FINDINGS ................................................................... 8 Applicable Subdivision Review Criteria, Section 38.240.130, BMC................................. 8 Primary Subdivision Review Criteria, Section 76-3-608 ................................................. 10 Preliminary Plat Supplements ........................................................................................... 11 APPENDIX A –PROJECT SITE ZONING AND GROWTH POLICY...................................... 13 APPENDIX B – NOTICING AND PUBLIC COMMENT ........................................................ 14 APPENDIX C - OWNER INFORMATION ................................................................................ 14 FISCAL EFFECTS ....................................................................................................................... 14 ATTACHMENTS ......................................................................................................................... 14 418 17483 Staff Report – Lot 11 Gallatin Center Subdivision Page 4 of 14 SECTION 1 - MAP SERIES Figure 1 Vicinity and Zoning Map 419 17483 Staff Report – Lot 11 Gallatin Center Subdivision Page 5 of 14 Figure 2 Growth Policy Map 420 17483 Staff Report – Lot 11 Gallatin Center Subdivision Page 6 of 14 Figure 3 Preliminary Plat SECTION 2 - RECOMMENDED CONDITIONS OF APPROVAL Please note that these conditions are in addition to any required code provisions identified in this report. Recommended Conditions of Approval: 1. The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman Municipal Code or state law. 2. The plat shall conform to all requirements of the Bozeman Municipal Code and the Uniform Standards for Subdivision Plats (Uniform Standards for Certificates of Survey and Subdivision Plats (24.183.1104 ARM) and shall be accompanied by all required documents, including certification from the City Engineer that as-built drawings for 421 17483 Staff Report – Lot 11 Gallatin Center Subdivision Page 7 of 14 public improvements were received, a platting certificate, and all required and corrected certificates. The Final Plat application shall include three (3) signed reproducible copies on a 3 mil or heavier stable base polyester film (or equivalent); two (2) digital copies; one (1) PDF copy; and five (5) paper prints. The Gallatin County Clerk & Recorder’s office has elected to continue the existing medium requirements of 2 mylars with a 1½” binding margin on one side for both plats and COS’s. The Clerk and Recorder will file the new Conditions of Approval sheet as the last same sized mylar sheet in the plat set. 3. The applicant shall submit with the application for Final Plat review and approval, a written narrative stating how each of the conditions of preliminary plat approval and noted code provisions have been satisfactorily addressed, and shall include a digital copy (pdf) of the entire Final Plat submittal. This narrative shall be in sufficient detail to direct the reviewer to the appropriate plat, plan, sheet, note, covenant, etc. in the submittal. 4. The final plat must provide all necessary utility easements and must be described, dimensioned and shown on each subdivision block of the final plat in their true and correct location. 5. Subdivision lighting SILD information shall be submitted to the Clerk of Commission after Preliminary Plat approval in hard copy and digital form. The initial adoption of the special improvement lighting district shall include the entire area of the preliminary plat. At the time the SILD is created both lots 11A and 11B must be a part of the district. SECTION 3 - CODE REQUIREMENTS REQUIRING PLAT CORRECTIONS The following are procedural requirements not yet demonstrated by the plat. 1. The final plat must contain updated references to the newest version of the Unified Development Code, Chapter 38 of the Bozeman Municipal Code, effective March 31, 2018. Specifically the water rights note should reference Section 38.410.130. 2. The final plat must contain updated dates. 3. Revise the Certificate of Exclusion from Montana DEQ Review to site the correct MCA exclusion reference to be MCA 76-4-125(1)(d). The recently revised reference from the last state legislative session cited on the plat does not go into effect until October 1, 2019. 4. Section 38.240.450 requires a certificate of completion of improvements. Certificate must specifically list all installed improvements and financially guaranteed improvements, specifically street lights along Cattail Street from North 19th to Max Avenue. 5. Section 38.550.070. In accordance with the requirements of this section, installation by the developer of vegetative ground cover, boulevard trees, and irrigation system in the public right-of-way boulevard strips and adjacent to public parks or other open space 422 17483 Staff Report – Lot 11 Gallatin Center Subdivision Page 8 of 14 areas is required prior to the final plat application of that phase. Applies to any boulevard landscaping needing repaired or not already existing. SECTION 4 - RECOMMENDATIONS AND FUTURE ACTIONS The DRC determined that the application is adequate for continued review and recommended approval with conditions on May 7, 2019. The Planning Board conducted a public hearing to review the preliminary plat and make a recommendation to the City Commission on June 4, 2019 and voted 8-0 to recommend approval. The public hearing date for the City Commission is June 17, 2019. The hearing will be held in the City Commission chamber, 121 N Rouse Avenue at 6 pm. SECTION 5 - STAFF ANALYSIS AND FINDINGS Analysis and resulting recommendations are based on the entirety of the application materials, municipal codes, standards, and plans, public comment, and all other materials available during the review period. Collectively this information is the record of the review. The analysis is a summary of the completed review. Applicable Subdivision Review Criteria, Section 38.240.130, BMC. In considering applications for subdivision approval under this title, the advisory boards and City Commission shall consider the following: 1) Compliance with the survey requirements of Part 4 of the Montana Subdivision and Platting Act The preliminary plat has been prepared in accordance with the survey requirements of the Montana Subdivision and Platting Act by a Professional Engineer registered in the State of Montana. As noted in recommended Condition of Approval No. 2, the final plat must comply with State statute, Administrative Rules of Montana, and the Bozeman Municipal Code. 2) Compliance with the local subdivision regulations provided for in Part 5 of the Montana Subdivision and Platting Act The final plat shall comply with the standards identified and referenced in the Unified Development Code (UDC). The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as a condition of approval, does not, in any way, create a waiver or other relaxation of the lawful requirements of the Bozeman Municipal Code or State law. Sections 2 and 3 of this report identify conditions and code corrections necessary to meet all regulatory standards. Therefore, upon satisfaction of all conditions and code corrections the subdivision will comply with the local subdivision regulations. 423 17483 Staff Report – Lot 11 Gallatin Center Subdivision Page 9 of 14 3) Compliance with the local subdivision review procedures provided for in Part 6 of the Montana Subdivision and Platting Act The City of Bozeman Department of Community Development received a preliminary plat application on October 04, 2017, requesting a second or subsequent minor subdivision. The project was deemed inadequate for review and review halted until revised materials were provided. Revised materials were submitted on November 13, 2018 and the application was again deemed inadequate on December 19, 2018. Revised materials were received between January and March. The application was deemed inadequate on March 7, 2019. Revised materials were received between March and May. The application was deemed adequate on May 7, 2019 and public hearings were scheduled. The hearings before the Planning Board and City Commission have been properly noticed as required by the Bozeman UDC. Based on the recommendation of the DRC and other applicable review agencies, as well as any public testimony received on the matter, the Planning Board shall forward a recommendation to the City Commission who will make the final decision on the applicant’s request. The final decision for a second or subsequent minor subdivision preliminary plat must be made within 60 working days of the date it was deemed adequate. Pursuant to Section 38.240.130.A.5.a(3), BMC, the City Commission shall approve, conditionally approve or deny the subdivision application by June 17, 2019, unless there is a written extension from the developer, not to exceed one year. Public notice for this application was given as described in Appendix C. 4) Compliance with Chapter 38, BMC and other relevant regulations Based on review of the DRC and the Department of Community Development all applicable regulations appear to be met if all code requirements are satisfied. Pertinent code provisions and site specific requirements are included in this report for consideration in Sections 2 and 3. 5) The provision of easements to and within the subdivision for the location and installation of any necessary utilities All easements, existing and proposed, must be accurately depicted and addressed on the final plat and in the final plat application. Therefore, all utilities and necessary utility easements will be provided and depicted accordingly on the final plat. 6) The provision of legal and physical access to each parcel within the subdivision and the notation of that access on the applicable plat and any instrument transferring the parcel All of the proposed lots have frontage to proposed public streets required to be constructed to City standards per 38.400 and associated design standards. In addition, pursuant to Section 38.400.090.A, BMC, plats shall contain a statement requiring lot accesses to be built to the 424 17483 Staff Report – Lot 11 Gallatin Center Subdivision Page 10 of 14 standard contained in this section, the city design standards and specifications policy, and the city modifications to state public works standard specifications. Primary Subdivision Review Criteria, Section 76-3-608 1) The effect on agriculture The subject property is designated as regional commercial and services according to the City of Bozeman Community Plan. The area is zoned for commercial development and has largely already been developed. The subdivision is entirely surround by urban conditions, this subdivision will not have adverse effects on agriculture. 2) The effect on Agricultural water user facilities No agricultural water user facilities exist on the property. The area is zoned for commercial development, and has developed in all directions. 3) The effect on Local services Water/Sewer – Municipal water and sewer can be provided to this site. Adequate sewer and water capacity exists to serve the development. Internal water and sewer mains already exist. Cash-in-lieu of water rights is required to provide long-term water to the project. A note on page 1 of the plat notes that this payment has been deferred until future development occurs within this subdivision. Water rights or cash-in-lieu of water rights must be provided prior to final site plan approval or the issuance of any building permit. Streets – The Growth Policy and subdivision standards require adequate connectivity of the street grid to ensure sufficient infrastructure to serve the needs of the public and alleviate congestion. The preliminary plat shows access from North 19th and Cattail Street, both existing streets. The mutual access between lots is maintained by the Gallatin Center Covenants. A deviation request to Engineering allowing an additional access across the Cattail St. no-access strip was denied. Street lighting is a component of the required street improvements. A special improvement lighting district is proposed to maintain these facilities. Condition 5 ensures that the SILD will be formed and effective. The requirement for a single SILD will simplify long-term maintenance of the streetlights and provide a cost that is more equitably shared. Code Requirement 4 requires the street lights along Cattail Street to be installed or financially guaranteed prior to final plat. Maintenance and use of public streets is subject to the terms of the municipal code. Police/Fire – The area of the subdivision is within the service area of both these departments. No concerns on service availability have been identified. The necessary addresses will be provided to enable 911 response prior to recording of the final plat. Stormwater - The subdivision will utilize existing on-site stormwater collection systems. A stormwater design report was provided and reviewed by the Engineering Division and a draft 425 17483 Staff Report – Lot 11 Gallatin Center Subdivision Page 11 of 14 stormwater management plan was provided. A note on page 1 of the plat states that all on-site stormwater infrastructure is to be maintained by the POA. 4) The effect on the Natural environment Wetlands exist along the property boundary to the west, which are related to the adjacent creek. The watercourse setback for this watercourse and wetland is contained in lot 11A and noted on the plat. No regulated activities are proposed in these setbacks beyond existing improvements. 5) The effect on Wildlife and wildlife habitat No known effects to wildlife or habitat have been provided. The proposed subdivision is in an urban environment and FWP was not contacted since this requirement was waived during pre- application review. 6) The effect on Public health and safety The intent of the regulations in Chapter 38 of the Bozeman Municipal Code is to protect the public health, safety and general welfare. The subdivision has been reviewed by the DRC which has determined that it is in general compliance with the title. Conditions deemed necessary to ensure compliance are noted throughout this staff report. All subdivisions must be reviewed against the criteria listed in 76-3-608.3.b-d, Mont Code Annotated. The Department of Community Development has reviewed this application against the listed criteria and provides the following summary for submittal materials and requirements. Preliminary Plat Supplements A subdivision pre-application plan review was completed by the DRC on July 25, 2017. With the pre-application plan review application, waivers were requested from the materials required in Section 38.220.060 “Additional Subdivision Preliminary Plat Supplements.” Some items were not waived and all required material has been addressed. Staff offers the following summary comments on the supplemental information required with Article 38.220, BMC. 38.220.060.A.1 Surface Water Surface waters on the property include the East Catron Creek, which runs along the west property boundary. Mitigation and buffers to this watercourse and any associated wetlands were reviewed and approved with the original subdivision. No impacts to surface waters are identified with this application. Improvements to watercourse setback landscaping and rehabilitation will be reviewed with subsequent development applications. 38.220.060.A.2 Floodplains Material Waived. The hydrologic analysis completed in 1998 for waterways traversing the Gallatin Center Subdivision was deemed acceptable and no new analysis was required. No impacts to flood plains are identified. 426 17483 Staff Report – Lot 11 Gallatin Center Subdivision Page 12 of 14 38.220.060.A.3 Groundwater This requirement was reviewed by the Engineering Division. A letter certifying that the groundwater depths were not of concern was provided by Madison Engineering with their November 2018 re-submittal and this was found to be acceptable by City Engineers. This letter can be found in the project documents accompanying this report. 38.220.060.A.4 Geology, Soils and Slopes No unusual geological features are present. A NRCS web soil survey conducted in 2017 is provided with the application documents. 38.220.060.A.5 Vegetation Material waived. The subdivision area is largely already developed and no impacts to vegetation identified. 38.220.060.A.6 Wildlife Material waived. No critical wildlife species or habitat are known to be found on the property. 38.220.060.A.7 Historical Features Material waived. No notable features are on the site. 38.220.060.A.8 Agriculture Material waived. No agriculture resources present. 38.220.060.A.9 Agricultural Water User Facilities Material waived. No agricultural water user facilities identified. 38.220.060.A.10 Water and Sewer The proposed lots will be serviced by existing water and wastewater mains that run through the property. A water design report was reviewed by the Engineering Division and no issues identified. 38.220.060.A.11 Stormwater Management A stormwater design report and draft maintenance plan were reviewed by the Engineering Division. This subdivision proposes to utilize existing facilities for drainage. 38.220.060.A.12 Streets, Roads and Alleys See discussion above under primary review criteria. 38.220.060.A.13 Utilities All private utilities servicing the subdivision already exist or will be reviewed during subsequent development. See discussion above under primary review criteria regarding extension of water and sewer. All private utilities are available in the area. 427 17483 Staff Report – Lot 11 Gallatin Center Subdivision Page 13 of 14 38.220.060.A.14 Educational Facilities Material waived. This is a commercial development. 38.220.060.A.15 Land Use Material waived. The use proposed is exclusively commercial which conforms to the future land use designation and zoning purposes. 38.220.060.A.16 Parks and Recreation Facilities Material waived. This is a commercial development. 38.220.060.A.17 Neighborhood Center Plan Material waived. This is a commercial development. 38.220.060.A.18 Lighting Plan All street lights installed must use LED light heads and must conform to the City’s requirement for cut-off shields as required by the City’s specifications. A Special Improvement Lighting District (SILD) will be created 38.220.060.A.19 Miscellaneous Material waived. No additional impacts or hazards anticipated. 38.220060.A.20 Affordable Housing Material waived. This is a commercial development. APPENDIX A –PROJECT SITE ZONING AND GROWTH POLICY Zoning Designation and Land Uses: The subject property is zoned B-2 (Community Business District). The intent of the B-2 community business district is to provide for a broad range of mutually supportive retail and service functions located in clustered areas bordered on one or more sides by limited access arterial streets. Multi-household dwellings, townhouses, and apartments are allowed as a secondary use due to their complementary nature and ability to enhance the walkability of these districts. Design standards emphasizing pedestrian oriented design are important elements of this district. Use of this zone is appropriate for arterial corridors, commercial nodes, and/or areas served by transit. Adopted Growth Policy Designation: The Future Land Use Map of the Bozeman Community Plan designates the subject property to develop as “Regional Commercial and Services.” Bozeman is a retail, education, health services, public administration, and tourism hub and provides opportunities for these activities for a multi-county region. Often the scale of these services is larger than would be required for Bozeman alone. Because of the draw from outside Bozeman, it is necessary that these types of facilities be located in proximity to significant transportation routes. Since these are large and prominent facilities within the community and 428 17483 Staff Report – Lot 11 Gallatin Center Subdivision Page 14 of 14 region, it is appropriate that design guidelines be established to ensure compatibility with the remainder of the community. Opportunity for a mix of uses which encourages a robust and broad activity level is to be provided. Residential space should not be a primary use and should only be included as an accessory use above the first floor. Any development within this category should have a well integrated transportation and open space network which encourages pedestrian activity, and provides ready access within and to adjacent development. APPENDIX B – NOTICING AND PUBLIC COMMENT Notice was provided at least 15 and not more than 45 days prior to the Planning Board and City Commission public hearings. Per Article 38.220, Notice was provided by posting the site, mailing by certified mail to adjacent property owners and by first class mail to all other owners within 200 feet, and by legal advertisement publication in the Bozeman Daily Chronicle. Content of the notice contained all elements required by Article 38.220, BMC. No public comment has been received. APPENDIX C - OWNER INFORMATION Owner: Gallatin TR LP, 2501 N Josey Ln Str 120, Carrollton, TX 75006-1600 Applicant: Same as owner Representative: Madison Engineering, 895 Technology Blvd, Suite 203, Bozeman, MT 59718 FISCAL EFFECTS The development will generate the typical costs and revenues of commercial development. ATTACHMENTS The full application and file of record can be viewed at the Community Development Department at 20 E. Olive Street, Bozeman, MT 59715. Application Documents & Appendices Application Plans 429 430 431 432 433 434 435 436 437 438 439 Agency Letters The attached letter was addressed to each of the following agencies and sent on August 10, 2017 in order to solicit comments regarding the development of the Lot 11 Gallatin Center Subdivision. A copy of all responses received is included. Streamline 32 S Tracy Bozeman, MT 59715 George Durkin Gallatin County Road and Bridge Dpt 205 Baxter Lane West Bozeman, MT 59715 Brian Gootkin, Sheriff Gallatin County Sheriff’s Department 615 S 16th Ave Bozeman, MT 59715 USPS 5711 Baxter Lane Bozeman, MT 59718 CenturyLink 502 S 19th Ave Bozeman, MT 59718 Charter Communications 511 W Mendenhall Bozeman, MT 59715 Med Trans Montana 2101 Industrial Drive Bozeman, MT 59715 Harry Kirshenbaum Republic Services of Montana PO Box 10730 Bozeman, MT 59719 Northwestern Energy PO Box 490 Bozeman, MT 59715 Bozeman Fire Department 34 N Rouse Ave Bozeman, MT 59715 Bozeman Deaconess Hospital 915 Highland Blvd Bozeman, MT 59715 Northwestern Energy 121 E Griffin Dr Bozeman, MT 59715 DNRC Water Resources 2273 Boot Hill Court, Suite 110 Bozeman, MT 59715 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 Lot 11 Gallatin Center Subdivision Driveway Approach Separation Deviation Request Page 1 of 2 LOT 11 GALLATIN CENTER SUBDIVISION DRIVEWAY APPROACH SEPARATION DEVIATION REQUEST Gallatin TR proposes to subdivide Lot 11 of the Gallatin Center on N 19th Ave into two lots, Lot 11A and Lot 11B. The future Lot 11B is the home of the existing Bed, Bath, and Beyond, and the City Brew building. Access into Lot 11 is currently available through N 19th Ave to the east of the lot and Cattail Street to the south of the lot. Madison Engineering proposed an additional access drive to the west of the existing driveway on Cattail. This additional access is proposed to give delivery trucks an alternate route to exit the site after delivery that does not require them to drive along the storefront, where pedestrians tend to be in high volume going from their car to the store. Delivery trucks coming into the lot to deliver goods will drive from west to east and turn into the back delivery drive between Lot 11 and Lot 10 to the north. This back delivery drive access is one-way. When they reach the end of the delivery drive to the west, they will turn south on the western side of the future building to exit the lot. To reduce mingling of pedestrians, customer vehicles, and delivery trucks, the second access is proposed so the delivery trucks can exit essentially straight to the south. This second access does not meet the full access separation requirements set forth in Bozeman Municipal. Therefore we are requesting a deviation from Section UDC 38.24.090.D.3 – Minimum Separation of the Unified Development Code. Below is the criteria outlined by the City for consideration of the deviation request, followed by our response to each item. UDC 38.24.090.H Commercial developments (including residential complexes for five or more households) which may not be able to meet the requirements of subsections C through E of this section, and are requesting modifications from the standards, shall submit to the city engineer a report certified by a professional engineer addressing the following site conditions, both present and future: a. Traffic volumes; Response: Based on information outlined in the Institute for Traffic Engineers’ (ITE) Trip Generation Manual (9th edition) it is estimated that each 1,000 sf of a General Store will generate approximately 1.87 trips per Peak Hour. Based on the assumed future 43,260 sf facility this equates to approximately 81 peak hour trips. It is expected however for much of this traffic to enter/exit through the two other existing driveways on Cattail St and N 19th Ave. b. Turning movements; Response: The driveway is designed for full turning movements. 476 Lot 11 Gallatin Center Subdivision Driveway Approach Separation Deviation Request Page 2 of 2 c. Traffic controls; Response: A stop sign is proposed on the exit side of the driveway onto Cattail Street. d. Site design; Response: The proposed drive access was included in the original master site plan for the purpose of delivery truck traffic. The proposed drive has limited flexibility due to little distance from Max Ave, the no-access strip, and the existing driveway into Lot 11 to the east. The existing locations of the buildings on future Lot 11B and on Lot 10 support the need for the future buildings on Lot 11A to be where they are shown on the site plan. This means that the delivery trucks will be required to travel on the path shown in the exhibit attached to this deviation, which is also the most efficient and safe path for the trucks to drive. This proposed access will allow delivery trucks to avoid driving along the future storefront, where many pedestrians will likely be. e. Sight distances; Response: Site distance is unobstructed in all directions on Cattail Street. f. Location and alignment of other access points. Response: There are no other practical options available if pedestrian and delivery truck mingling along the storefront is to be avoided. The existing access to the east on Cattail Street is angled toward the east, which would disallow delivery truck drivers to exit there unless they first went along the storefront. 477 1 Gallatin Center Lot 11 Subdivision Response to Pre-Application Comments PLANNING COMMENTS 1. Waivers to the supplemental information under 38.41.060, BMC are recommended to be granted with this pre-application plan review as described in the pre-application plan for: 5) vegetation, 6) wildlife, 7) historical features, 8) agriculture, 9) agricultural water user facilities, 13) utilities, 14) educational facilities, 15) land use, 16) parks and recreation facilities, 17) neighborhood center plan, 18) lighting plan, 19) miscellaneous, and 20) affordable housing. Response: Waivers noted. 2. Waivers to the supplemental information under 38.41.060, BMC recommended to not be granted include 1) surface water; 2) floodplains; 3) groundwater; 4) geology, soils, slopes; 10) water & sewer; 11) stormwater management (if a detention pond is intended to be constructed with a future site plan application); and 12) streets, roads and alleys. All applicable information related to the above and listed in 38.41.060 BMC for review are required with the preliminary plat application. Updated information may only require a brief one-paragraph summary review of each of the items listed in Section 38.41.060, BMC, regardless of whether or not the information has been waived. This will assist the City Commission in their review of the application Please make sure to address all other applicable supplemental information as set forth in Section 38.41.060, BMC, which has not been waived. Response: Required supplemental information noted. The required supplemental information can be found in Section 5 of the preliminary plat application. 3. Please provide documentation to support any released portions of easements. Response: There are no proposed release of easements at this time. 478 2 ENGINEERING COMMENTS 1. The requested waiver for Water and Sewer is not granted. At a minimum, the applicant must submit the original subdivision report for water and sewer and adjust the assumptions in the report to reflect current plans. The adjusted report must be submitted with the preliminary plat application. Response: The sewer and water reports describing these systems that serve Lot 11 were written by Allied in 2002. These reports were searched for both by the City of Bozeman and Allied Engineering, and neither report could be found. New sanitary Sewer and Water design reports are included in Section 10.A. of this submittal, where a letter from the city confirming sanitary sewer capacity is also included. 2. The applicant must submit the anticipated peak-hour sanitary sewer demand for the proposed subdivision with the preliminary plat submittal, and the City Engineering Department will review downstream sanitary sewer capacity upon submittal of the preliminary plat. Response: A sanitary sewer design report is included in Section 10.A. of this submittal. A copy of an email from the City Engineer, Shawn Kohtz, confirming capacity is included in Section 10.A. 3. The requested waiver for Streets, Roads, and Alleys is not granted. The applicant must submit a copy of the original subdivision traffic impact study with the preliminary plat application. That traffic impact study may be required to be updated upon future site plan application for development on Lot 11A. Response: No new streets are proposed as part of this project. Shawn Kohtz with the City of Bozeman is not requiring a traffic impact study to be submitted. The original traffic impact study (TIS) for Gallatin Center is a very large document and because of this, Kohtz approved this original TIS not needing to be included in this application. It can be referenced in the City of Bozeman archives. 4. The proposed driveway onto Cattail Street does not meet drive access spacing requirements per Bozeman Municipal Code (BMC) 38.24.090.D.3. Additionally, there is a no-access strip along Cattail Street at the proposed drive access. Traffic from Lot 11A must use existing drive accesses. A new access will not be allowed onto Cattail Street. 479 3 Response: A deviation permit is included with this submittal. An additional access is proposed where an existing no-access strip ends east of Max Ave on the lot’s frontage to Cattail St. This access is proposed in an effort to improve pedestrian safety by directing large delivery vehicles around the perimeter of the parking lot opposed to directly in front of the building. Section 10.G. includes a deviation request for this drive access onto Cattail, including an exhibit showing the truck routes. 5. Unless a building restriction is filed with Lot 11A, the applicant must construct street lights along Cattail Street adjacent to the subdivision boundary at the spacing and per the standards defined in the City of Bozeman Design Standards and Specifications Policy prior to final plat approval. Response: The applicant acknowledges this condition. Street lights along Cattail Street adjacent to the subdivision will be constructed at the spacing and per the standards defined in the City of Bozeman Design Standards and Specifications Policy prior to the final plat approval. 6. A shared access and drainage easement exists for Lots 11A and 11B. However, the applicant must either demonstrate or provide a shared access easement for the northern shared drive access between Lot 10 and Lot 11. Response: There already exists a shared access easement for the northern shared drive access between Lot 10 and Lot 11. This can be found in the recorded Declaration of Protective Covenants, Conditions, and Restrictions for The Gallatin Center, Article XI: Easements, 11.1 (pg 18) in Section 6 of this application. 7. If not already filed with the original subdivision, the applicant must provide and file with the County Clerk and Recorder's office executed Waivers of Right to Protest Creation of Special Improvement Districts (SID’s) for the following: a. Street improvements to Cattail Street including paving, curb/gutter, sidewalk, and storm drainage b. Street improvements to Max Avenue including paving, curb/gutter, sidewalk, and storm drainage c. Street improvements to N. 27th Avenue/Thomas Drive including paving, curb/gutter, sidewalk, and storm drainage d. Street improvements to N. 19th Avenue including paving, curb/gutter, sidewalk, and storm drainage e. Intersection improvements to N. 27th Avenue/Thomas Drive and Cattail 480 4 Street f. Intersection improvements to Cattail Street and N. 19th Avenue g. Intersection improvements to Max Avenue and Cattail Street The document filed must specify that in the event an SID is not utilized for the completion of these improvements, the developer agrees to participate in an alternate financing method for the completion of said improvements on a fair share, proportionate basis as determined by square footage of property, taxable valuation of the property, traffic contribution from the development, or a combination thereof. The applicant must provide a copy of the filed SID waiver prior to final plat approval. Response: Draft Executed Waivers of Right to Protest Creation of Special Improvement Districts can be found in Section 10.B. of the preliminary plat application. Upon review and approval by City of Bozeman, the documents will be signed and recorded. 8. The applicant must contact the City Floodplain Coordinator (Brian Heaston) and review any requirements for a flood hazard analysis for the stream adjacent to Lot 11A. Response: Brian Heaston was contacted and does not require a flood hazard analysis for East Catron Creek that flows adjacent to Lot 11A. 9. The applicant is advised that the proposed project falls within the Bozeman Solvent Site boundary. The property is underlain by an aquifer contaminated with perchloroethylene (PCE). No irrigation wells may be installed on this property. Response: The applicant acknowledges that the project falls within the Bozeman Solvent Site boundary. No irrigation wells will be installed on this property. STANDARD CODE PROVISIONS The preliminary plat must comply with the standards identified and referenced in the Unified Development Code. The applicant is advised that unmet code provisions, or code provisions that are not specifically listed as conditions of approval, does not, in any way, create a deviation or other relaxation of the lawful requirements of the Bozeman Municipal Code or state law. The following requirements are standards of the Unified Development Code and the Bozeman Municipal Code (BMC) and must be addressed with the preliminary plat application: 481 5 1. The preliminary plat must conform to all requirements of the Bozeman Municipal Code and the Uniform Standards for Subdivision Plats (Uniform Standards for Certificates of Survey (COS) and Subdivision Plats (24.183.1104 ARM). Response: The applicant acknowledges this condition. The preliminary plat will conform to all requirements of the Bozeman Municipal Code and the Uniform Standards for Subdivision Plats and Subdivision Plats. 2. Section 38.41.050.A.8, BMC “Noxious Weed Management and Revegetation Plan” – Please include in the supplemental information clarification that the control of noxious weeds will apply to all areas of the subject property, including those lands not included with the pre-application plan review. Control of noxious weeds should be coordinated with the County Weed Control office and shall be updated with a new noxious weed management and revegetation plan. Response: An approved Noxious Weed Management and Revegetation Plan is included in Section 7 in the application. All parts of the property have been included in the pre-application plan review. The applicant acknowledges control of noxious weeds to be coordinated with the County Weed Control office. 3. Section 38.23.060, Utility easements must be provided in accordance with the UDC. The required 10-foot front yard easement is required for all lots unless written confirmation is submitted with the preliminary plat from ALL utility companies providing service indicating that front yard easements are not needed. All easements must be described, dimensioned and shown on the final plat in their true and correct location. Response: The preliminary plat that is included in Section 9 of this application show an existing 12’ wide public utility easement on the west side of Lot 11 along Max Ave; an existing 12’ wide utility easement along Cattail Street; and, an existing 25’ wide public utility easement. 4. Section 38.23.080.G Finish Grade. All finish grades in landscaped areas must comply with the provisions set forth in Section 38.26.050.L. Response: The applicant acknowledges this condition. All finish grades in landscaped areas will comply with the provisions set forth in Section 38.26.050.L. 5. Section 38.23.080.H Landscape Amenities. Stormwater retention/detention facilities in landscaped areas shall be designed as landscape amenities. They shall be an organic feature with a natural, curvilinear shape. The facilities shall have 75 percent of surface area covered with live vegetation appropriate for the depth and design of the retention/detention facility, and be lined with native grasses, indigenous plants, wet 482 6 root tolerant plant types and groupings of boulders to create a functional yet, natural site feature. A visual inspection notes that some of the stormwater facilities do not comply with this section including the 25% maximum slope. Response: The existing stormwater facility on this lot is a sedimentation/overflow pond for the stormwater as it travels from Lot 11 to the existing detention pond on Lot 10 (southwest corner of Max Ave and Burke Street. This on-site pond will be reconstructed to meet the requirements. 6. Section 38.27.090 Waiver of Park Maintenance District. Executed waivers of right to protest the creation of special improvement districts (SIDs) for a park maintenance district will be required to be filed and of record with the Gallatin County Clerk and Recorder, unless already filed. Response: There is no parkland required as this is a commercial development. 7. Section 38.39.030 Completion of Improvements. If it is the developer’s intent to file the plat prior to the completion of all required improvements, an Improvements Agreement must be entered into with the City of Bozeman guaranteeing the completion of all improvements in accordance with the preliminary plat submittal information and conditions of approval. If the final plat is filed prior to the installation of all improvements, the developer must supply the City of Bozeman with an acceptable method of security equal to 150 percent of the cost of the remaining improvements. Response: The applicant acknowledges this condition. 8. Section 38.41.050.A.8 requires that any noxious weeds be identified and mapped by a person with experience in weed management and knowledgeable in weed identification. A noxious weed management and revegetation plan, approved by the County Weed Control District, must be submitted with the preliminary plat. Response: An approved noxious weed management and revegetation plan is included in Section 7.A. 9. Article 6. The certificates listed in Section 38.06.020 through 38.06.110 must be shown on plat and certificates of survey, as appropriate. 483 7 Response: The applicant acknowledges this condition. 10. Article 41. All preliminary plat requirements, as outlined in Article 41, must be provided with the preliminary plat submittal, unless otherwise approved by the Development Review Committee via waiver. Response: The applicant acknowledges this condition. All preliminary plat requirements outlined in Article 41 are provided in this preliminary plat submittal. 11. A complete preliminary plat application must be submitted to the Community Development Department within one calendar year of the date the Community Development Department dates, signs and places pre-application comments in the outgoing mail. Response: The applicant acknowledges this condition. 484 Gallatin Center Lot 11 Preliminary Plat Supplemental Information Narrative 1 Gallatin Center Lot 11 Subdivision Preliminary Plat Supplemental Information Sec. 38.41.060., BMC 1. Surface Water 2. Floodplain 3. Groundwater 4. Geology, Soils, and Slope 5. Vegetation - waived 6. Wildlife - waived 7. Historical Features - waived 8. Agriculture - waived 9. Agriculture Water User Facilities - waived 10. Water and Sewer 11. Stormwater Management 12. Streets, Roads and Alleys 13. Utilities - waived 14. Educational Facilities - waived 15. Land Use - waived 16. Parks and Recreation Facilities - waived 17. Neighborhood Center Plan - waived 18. Lighting Plan - waived 19. Miscellaneous - waived 20. Affordable Housing - waived 485 Gallatin Center Lot 11 Preliminary Plat Supplemental Information Narrative 2 Introduction The proposed subdivision of the existing 8.615 acre lot is to create two (2) new lots: Lot11A and Lot11B. The underground utilities are in place for this development, including water and sewer infrastructure. East Catron Creek flows through the site on the west side, which has been mitigated for and will not be disturbed during the subdivision of Lot 11. The proposed Lot 11A is vacant, although has been slightly disturbed by the adjacent lots’ development and storm infrastructure. 1. Surface Water East Catron Creek flows through the west side of the property and runs south-north. Because this lot was included in the original subdivision of the Gallatin Center, this portion of East Catron Creek has been fully mitigated, including a 50’ wide stream setback to the east of East Catron and a 21’ wide setback to the west of East Catron. 2. Floodplain Brian Heaston with the City of Bozeman was contacted and requires no additional floodplain analysis for this project as the original subdivision of Gallatin Center included the analysis of East Catron Creek. 3. Groundwater The test pit logs on and near Lot 11 from the original Gallatin Center Subdivision’s geotechnical report are included in Section 10.C. of this application, along with a map of the test pit locations. The test pits reveal no groundwater to depths of 7’ (TP-18), 4’ (TP-19), and 9’ (TP-20). Additionally included is the groundwater monitoring of the nearby Opportunity Subdivision to the south, across Cattail St. Groundwater was monitored on this site from January 2015 to November of 2016 using eight (8) monitoring wells, the locations and depths of which are shown in Section 10.C. Per these monitoring results, the groundwater never came within less than 3.72 feet of the surface, with an average depth of 5.43 feet. A contaminated aquifer, known as the Solvent Site, underlies the proposed development. The aquifer is contaminated with tetrachloroethylene (PCE). No irrigation wells will be allowed to support irrigation at the site, and the City water supply must be used for irrigation water to prevent further spread of contamination and public exposure to contaminants. Additionally, this site will be served by a central sewer and water main that will connect to the City of Bozeman, which will minimize the potential for further groundwater contamination. Channeling storm-water flows into detention basins will limit discharges to pre-development rates and will control surface water runoff. These basins will reduce the amount of sediments and contaminants within the surface runoff and also reduce potential for contamination of downstream aquifers. 4. Geology, Soils and Slope There are no known geologic hazards, areas of instability, or unusual soil, topographic or geologic conditions present on site. The site topography slopes at an approximate 1.2% in a northern direction. Proposed lot grades will not exceed 3% and slope work will not exceed a 4:1 horizontal:vertical ratio. The following NRCS soils mapping data is included in Section 10.D of this application: 486 Gallatin Center Lot 11 Preliminary Plat Supplemental Information Narrative 3 - Soils Map - Physical Properties - Engineering Properties - Soil Limitations for Dwellings and Small Commercial Buildings - Soil Limitation for Roads and Streets, Shallow Excavations, Lawns, and Landscaping - Water Features - Hydric Soils 5. Vegetation - waived This section has been waived. 6. Wildlife - waived This section has been waived. 7. Historical Features - waived This section has been waived. 8. Agriculture - waived This section has been waived. 9. Agriculture Water User Facilities - waived This section has been waived. 10. Water and Sewer The proposed lot will be serviced by the existing City of Bozeman sanitary sewer and water main that runs through the utility easement between Lot 11 and the adjacent Lot 10 to the north. The stubbed water and sewer services will be extended into the future buildings when constructed. A water design report is contained in Section 10.E. of this application. Section 10.E. also contains a sewer report that calculates a peak flow, which was given to the City of Bozeman for them to confirm capacity. This confirmation correspondence is also included in Section 10.E. 11. Stormwater Management On-site stormwater runoff will be managed utilizing the existing stormwater collection system. All runoff will flow into an existing curb inlet at the northwest corner of the parking lot, from where it will flow north into the existing stormwater detention pond on the southwest corner of Max Ave and Burke Street. A stormwater design report is included in Section 10.F. of this application. 12. Streets, Roads and Alleys All lots will meet the minimum lot size and as well as minimum street frontage. Access to the new lot will be from an existing access on N 19th to the east as well as from an existing access on Cattail Ave, and one additional access on Cattail Ave. An additional access is proposed where an existing no-access strip ends east of Max Ave on the lot’s frontage to Cattail St. This access is proposed in an effort to improve pedestrian safety by directing large delivery vehicles around the perimeter of the parking lot as opposed to in front of 487 Gallatin Center Lot 11 Preliminary Plat Supplemental Information Narrative 4 the building. This deviation is included in Section 10.G. along with a site plan showing truck movement. No new streets are proposed as part of this project. A traffic impact study was not required with the pre-application comments. The original traffic impact study for Gallatin Center may be referenced, which due to its large size we have been allowed to not include it in this application. It may be referenced in the City of Bozeman report archives. 13. Utilities - waived This section has been waived. 14. Educational Facilities - waived This section has been waived. 15. Land Use - waived This section has been waived. 16. Parks and Recreation Facilities - waived This section has been waived. 17. Neighborhood Center Plan - waived This section has been waived. 18. Lighting Plan - waived This section has been waived. 19. Miscellaneous - waived This section has been waived. 20. Affordable Housing - waived This section has been waived. 488 489 EXHIBIT 1MADISON ENGINEERING 895 TECHNOLOGY BLVD, SUITE 203 BOZEMAN, MT 59718 PHONE (406) 586-0262 FAX (406) 586-5740 GALLATIN CENTER LOT 11 USGS LOCATION MAP BOZEMAN, MT -NOT TO SCALE- 1" = 0 SCALE 500' 1000250500 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 P.O.BMAX AVENUE 60' R/W CATTAIL STREET90' R/WN 90°00'00" E24.27'L = 60.17'R = 345.00'D = 9°59'35"CH BRG = N 85°21'03" WCH LENGTH = 60.10'L = 48.88'R = 255.00'D = 10°58'58"CH BRG = N 85°42'08" WCH LENGTH = 48.80'PROJECTLOCATIONSHEETMADISON ENGINEERING 895 TECHNOLOGY BLVD. STE. 203 BOZEMAN, MT 59718 (406) 586-0262 (406) 586-5740 FAXROADWAY GALLATIN CENTER LOT 11 MINOR SUBDIVISION BOZEMAN, MTGC LOT 11CONCEPT PLAN 1" =0SCALE40'802040DATUMLEGEND1 OF 1506