Loading...
HomeMy WebLinkAbout021 E2.1 MAIN & UPPER FLOOR ELECTRICAL PLANS 07-31-201810 1 GA R A G E 102 STORAGE 10 3 ST A I R 104 MECH. O. H . D . O. H . D . S S S S STO SWITCH ABOVE 5 8 " T Y P E ' X ' G.W . B . C E I L I N G @ 9 ' - 6 " A . F . F . 5 8 " T Y P E ' X ' G.W . B . C E I L I N G @ 9 ' - 6 " A . F . F . 5 8 " TYPE 'X'G.W.B. CEILING @ 6'-1" A.F.F. 5 8 " T Y P E ' X ' G.W . B . C E I L I N G @ 9 ' - 6 " A . F . F . 5 8 " T Y P E ' X ' G.W . B . C E I L I N G @ 7 ' - 4 " A . F . F . SD SYMBOL DESCRIPTION WALL MOUNTED FIXTURE CEILING MOUNTED PENDANT FIXTURE CEILING MOUNTED FIXTURE CEILING FAN SWITCH THREE-WAY SWITCH RECESSED CFL/INCANDESCENT FIXTURE ELECTRICAL LEGEND MONO-POINT FIXTURE EXHAUST FAN P S S 3R DUPLEX OUTLET 220V OUTLET DUPLEX OUTLET MOUNTED AT 42" DUPLEX OUTLET MOUNTED AT 42" W/ GROUND FAULT INTERUPTOR SWITCHED DUPLEX OUTLET THERMOSTAT PHONE JACK SMOKE & CARBON MONOXIDE DETECTOR DOOR BELL 42" GFI 42" T SD HOSE BIB MP MP PROPANE PSJJAMB SWITCH SWITCHED DUPLEX OUTLET IN FLOOR WATERPROOF DUPLEX OUTLET WP AFCI DUPLEX OUTLET W/ ARC FAULT CIRCUIT INTERRUPTOR ELECTRICAL PANEL COAX JACK PHONE/DATA JACK DATA JACK D DOOR BELL CHIME SBUILT-IN OR MOUNTED TV BUILT-IN OR MOUNTED SPEAKER EXHAUST FAN W/ LIGHT QUAD OUTLET S D S SC SPEED CONTROL SWITCH DIMMER SWITCH LINEAR SURFACE FIXTURE LINEAR SURFACE EMERGENCY FIXTURE LINEAR SURFACE FIXTURE W/ LENS LINEAR SURFACE EMERGENCY FIXTURE W/ LENS LINEAR PENDANT FIXTURE W/ LENS LINEAR PENDANT EMERGENCY FIXTURE W/ LENS LINEAR RECESSED FIXTURE W/ LENS LINEAR RECESSED EMERGENCY FIXTURE W/ LENS 201 STAIR 20 2 BE D R O O M 20 3 BA T H R O O M 204 SHOWER S U C R TV +7 2 " G F I 4 2 " R RWP S S R R R P P TO SWITCH BELOW E L E C T R I C B A S E B O A R D H E A T E R EL E C T R I C BA S E B O A R D HE A T E R 1x 4 S Q U A R E ED G E T & G CE I L I N G 8 : 1 2 8:12 1x 4 S Q U A R E ED G E T & G CE I L I N G 1x4 SQUARE EDGE T&G CEILING 8:12 8:12 8:12 5 8 " T Y P E 'X ' G . W . B . CE I L I N G SD SD 1. DEVICE MOUNTING HEIGHTS ARE TO CENTER OF BOXES U.N.O.2. OUTLET RECEPTACLES TO BE MOUNTED @ 18" A.F.F. U.N .O 3. ALL BEDROOMS TO HAVE AFCI PROTECTION FOR ALL OUTLETS, LIGHTS, SMOKE DETECTORS & RECEPTACLES.4. ALL KITCHEN COUNTERTOP OUTLETS ARE TO BE GFI RECEPTACLES. COORDINATE OUTLET BOX HEIGHT W/ COUNTERTOP AND BACKSPLASH HEIGHT SHOWN ON FLOOR PLAN.5. KITCHEN COUNTER OUTLETS TO BE A MAXIMUM SPACING O F 4'. GENERAL USE RECEPTACLES IN EVERY ROOM ARE TO BE INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE IS IN ANY WALL SPACE IS MORE THAN 6'. ALL RECEPTACLES ARE TO BE INSTALLED IN CONFORMANCE W/ IRC 2006 CHAPTER 38.6. INSTALL HVAC OUTLET FOR SERVICING HVAC EQUIPMENT IN ACCORDANCE W/ IRC 2006 E3801.11 7. RECESSED INCANDESCENT LUMINAIRES SHALL BE LISTED AS THERMALLY PROTECTED.8. ALL EXTERIOR LIGHTING FIXTURES ARE TO BE APPROVED FOR OUTDOOR USE BY MANUFACTURER.9. ALL SMOKE DETECTORS TO BE INTERCONNECTED AND INSTALLED IN ACCORDANCE W/ IRC 2006 SECTION R313.10. ELECTRICAL CONTRACTOR TO IDENTIFY AND LABEL EACH SPACE SERVED ON THE ELECTRICAL PANEL(S).11. SEE FOUNDATION PLAN FOR UFER GROUND LOCATION AND DETAIL.E2.1 MAIN & UPPER FLOOR ELECTRICAL PLANS SC A L E : 1 E2 . 1 MA I N F L O O R E L E C T R I C A L P L A N 1/ 4 " = 1 ' - 0 " SC A L E : 2 E2 . 1 UP P E R F L O O R E L E C T R I C A L P L A N 1/ 4 " = 1 ' - 0 " Desc. DateCopyright 2018 c REVISIONS No. bayliss architects, P.C.Bozeman, MT 59771-1134 P.O. Box 1134 generated: 7.31.2018 JOB NUMBER: checked by: drawn by: DATE ISSUED: WALSH GARAGE K.C. & KAREN WALSH 921 S. WILLSON AVE BOZEMAN, MT 59715 07/31/18 ISSUED FOR CONSTRUCTION jbt bw 2018-06BAYLISS WARD # 1697