HomeMy WebLinkAbout007 A2.1 MAIN & UPPER FLOOR & ROOF PLANS 07-31-201832'-0"
2
4
'
-
0
"
6
'
-
6
"
1
1
'
-
0
"
6
'
-
6
"
24'-0" 9'-6 12"4'-7" 5'-11 12"32'-0" 25'-0" 2'-5" 3'-11 1 2 "1 A4.1 1 A4.1 3 A4.1 3 A4.1
2 A4
.
1
2 A4.1 3'-11" 9'-0" 23'-0" 17 RISERS @ Ø 7 7/16" 16 TREADS @ 11" UP 1 A3.1 2 A3.1
3 A3
.
1
4 A3.1 101 GARAGE 102 STORAGE 103 STAIR ROOF OVERHANG SECOND FLOOR LANDING
RO
O
F
&
K
N
E
E
BR
A
C
E
S
1
0
1
C
1
0
1
B
102 6'-0" 8'-5 12"101A 4 A4.1 4 A4.1 BEAM KNEE BRACE,TYP. OF 3 7 1 2 "
BE
A
M
BE
A
M
104 MECH.104 PROVIDE 1 HR. RATING BELOW STAIR
32
'
-
0
"
16
'
-
6
"
5'-
0
"
2
'
-
0
"
3
'
-
1
1
"
2
'
-
1
1
"
2
4
'
-
0
"
2
'
-
0
"
2
0
'
-
0
"
2
'
-
0
"
32
'
-
0
"
6'-
4
"
9'-
0
"
2
'
-
0
"
5'-
6
"
1 A4
.
1
1 A4
.
1
3 A4
.
1
3 A4
.
1
2 A4
.
1
2 A4
.
1
3'-
0
"
2'-
0
"
1
'
-
2
"
1
7
R
I
S
E
R
S
@
Ø
7
7
/
1
6
"
1
6
T
R
E
A
D
S
@
1
0
"
DN
4
'
-
2
"
4
'
-
2
"
2
4
'
-
0
"
2'-
0
"
2
'
-
8
"
4
'
-
5
"
6
'
-
6
1
2
"
2
'
-
6
"
1
'
-
1
1
1
2
"
2
'
-
0
"
1 A3
.
1
2 A3
.
1
3 A3
.
1
4 A3
.
1
20
1
ST
A
I
R
20
2
BE
D
R
O
O
M
20
3
BA
T
H
R
O
O
M
20
4
SH
O
W
E
R
OP
E
N
T
O
BE
L
O
W
GU
A
R
D
R
A
I
L
RO
O
F
OV
E
R
H
A
N
G
RO
O
F
&
K
N
E
E
BR
A
C
E
S
RI
D
G
E
B
E
A
M
20
1
2
0
3
20
4
21 3
456
1
'
-
0
1
2
"
3
'
-
0
1
2
"
5
'
-
1
0
"
3
'
-
2
"
5
'
-
1
"
1
2
'
-
1
1
"
3
'
-
1
1
1
2
"
4 A4
.
1
4 A4
.
1
6'-
2
"
6'-
6
"
1
'
-
3
1
2
"
2
'
-
8
"
2
'
-
8
"
2'-
0
"
3'-
5
3 4 "
3'
-
0
1 4 "
2
0
2
A
2
0
2
B
3'-
3
3 4 "
3'
-
0
1 4 "
LI
N
E
N
C
A
B
I
N
E
T
SO
A
P
SH
E
L
F
3:
1
2
W
O
O
D
C
A
P
2
4
"
U
C
R
4
D
R
A
W
E
R
S
15
"
B
A
R
S
I
N
K
8:
1
2
8:
1
2
1'-
9
"
O'H
A
N
G
2'-
6
"
OV
E
R
H
A
N
G
2'-
6
"
OV
E
R
H
A
N
G
2
'
-
6
"
O
V
E
R
H
A
N
G
2
'
-
6
"
O
V
E
R
H
A
N
G
8
:
1
2
8:12
1 A4
.
1
1 A4
.
1
3 A4
.
1
3 A4
.
1
2 A4
.
1
2 A4
.
1
1 A3
.
1
2 A3
.
1
3 A3
.
1
4 A3
.
1
4 A4
.
1
4 A4
.
1
A2.1 MAIN & UPPER FLOOR & ROOF PLANS MAIN FLOOR UPPER FLOOR TOTAL GARAGE TOTAL 210 S.F.494 S.F.704 S.F.558 S.F.1262 S.F.NET FLOOR AREA
SC
A
L
E
:
1 A2
.
1
MA
I
N
F
L
O
O
R
P
L
A
N
1/
4
"
=
1
'
-
0
"
Desc. DateCopyright 2018 c REVISIONS No. bayliss architects, P.C.Bozeman, MT 59771-1134 P.O. Box 1134 generated: 7.31.2018 JOB NUMBER: checked by: drawn by: DATE ISSUED: WALSH GARAGE K.C. & KAREN WALSH 921 S. WILLSON AVE BOZEMAN, MT 59715 07/31/18 ISSUED FOR CONSTRUCTION jbt bw 2018-06BAYLISS WARD # 1697
SC
A
L
E
:
2 A2
.
1
UP
P
E
R
F
L
O
O
R
P
L
A
N
1/
4
"
=
1
'
-
0
"
SC
A
L
E
:
3 A2
.
1
RO
O
F
P
L
A
N
1/
4
"
=
1
'
-
0
"
1. ALL DOORS TO BE 6" FROM INT. WALL OR CENTERED IN WALL, U.N.O.2. FIREBLOCKING TO BE INSTALLED IN ACCORDANCE W/ IRC 2012 R302.11.3. APPLIANCES ARE TO HAVE CLEARANCE FROM COMBUSTIBLE CONSTRUCTION AS INDICATED BY MANUFACTURER AND/OR IN CONFORMANCE W/ IRC 2012 M1306.4. GAS FIRED UNITS TO BE MOUNTED ON 18" NONCOMBUSTIBLE PLATFORM.5. COMBUSTION AIR FOR GAS FIRED UNITS TO BE OBTAINED FROM OUTDOOR AIR IN ACCORDANCE W/ IRC 2012 G2407.6. PROVIDE DRAIN PAN UNDER WATER HEATER IN ACCORDANCE W/ IRC 2012 P2801.5 AND WASHER.7. STRAP AND ANCHOR EQUIPMENT DESIGNED TO BE FIXED IN PLACE TO RESIST HORIZ. DISPLACEMENT. STRAPPING SHALL BE AT POINTS WITHIN THE UPPER ONE-THIRD AND LOWER ONE-THIRD OF THE APPLIANCE'S VERTICAL DIMENSIONS. AT THE LOWER POINT, THE STRAPPING SHALL MAINTAIN A MINIMUM DISTANCE OF 4" ABOVE THE CONTROLS.8. FOR HOSE BIBBS SUSCEPTIBLE TO FREEZING, INSTALL I N ACCORDANCE W/ IRC 2012 P2903.10.9. SEE DOOR AND WINDOW SCHEDULES FOR GLAZING REQUIREMENTS.
1.
V
E
R
I
F
Y
A
L
L
R
O
O
F
P
E
N
E
T
R
A
T
I
O
N
S
W
/
F
L
O
O
R
P
L
A
N
.
2.
P
A
I
N
T
A
L
L
R
O
O
F
P
E
N
E
T
R
A
T
I
O
N
S
/
V
E
N
T
S
T
O
M
A
T
C
H
RO
O
F
.
3.
I
N
S
T
A
L
L
B
I
T
R
U
T
H
E
N
E
I
C
E
&
W
A
T
E
R
S
H
I
E
L
D
A
T
A
L
L
E
D
G
E
S
&
V
A
L
L
E
Y
S
W
/
3
0
"
M
I
N
.
W
I
D
T
H
S
I
N
C
O
N
J
U
N
C
T
I
O
N
W
/
TI
T
A
N
I
U
M
-
U
D
L
R
O
O
F
U
N
D
E
R
L
A
Y
M
E
N
T
.
4.
I
N
S
T
A
L
L
F
I
R
S
T
A
N
D
R
E
M
A
I
N
I
N
G
C
O
U
R
S
E
S
O
F
S
H
I
N
G
L
E
S
ST
A
I
R
-
S
T
E
P
P
I
N
G
D
I
A
G
O
N
A
L
L
Y
A
C
R
O
S
S
R
O
O
F
D
E
C
K
WI
T
H
M
A
N
U
F
A
C
T
U
R
E
R
'
S
R
E
C
O
M
M
E
N
D
E
D
O
F
F
S
E
T
PA
T
T
E
R
N
A
T
S
U
C
C
E
E
D
I
N
G
C
O
U
R
S
E
S
,
M
A
I
N
T
A
I
N
I
N
G
UN
I
F
O
R
M
E
X
P
O
S
U
R
E
.
5.
P
R
O
V
I
D
E
C
A
P
F
L
A
S
H
I
N
G
O
N
T
O
P
O
F
A
L
L
E
X
P
O
S
E
D
BE
A
M
S
.
6.
S
L
O
P
E
G
U
T
T
E
R
S
1
/
1
6
"
P
E
R
F
O
O
T
T
O
W
A
R
D
DO
W
N
S
P
O
U
T
.
D
I
S
T
R
I
B
U
T
E
R
U
N
O
F
F
E
Q
U
A
L
L
Y
W
H
E
R
E
MO
R
E
T
H
A
N
O
N
E
D
O
W
N
S
P
O
U
T
P
E
R
G
U
T
T
E
R
I
S
P
R
E
S
E
N
T
.