Loading...
HomeMy WebLinkAbout_The Pitt Addition Revisions and Corrections 05-23-19DARK GRAY CMU BLOCK 2X4 WOOD SIDING OUTSULATION ® PLUS MD SYSTEM -LIGHT COLOR EIFS VERTICAL CORRUGATED METAL SIDING (TYPICAL) OUTSULATION ® PLUS MD SYSTEM -DARK COLOR EIFS HORIZONTAL CORRUGATED METAL SIDING (BACK SIDE) DARK GRAY NOTE: REFER TO SHEET A-201 EXTERIOR MATERIALS FOR MORE DETAIL DESCRIPTIONS AND MATERIAL LOCATIONS. ARCHITECTURAL FOUNDATION PLAN 97' -6" PROJECT INFORMATION: PROJECT NAME: THE PITT TRAINING FACILITY - ADDITION PROJECT OWNER: DANE FLETCHER 3717 EQUESTRIAN LN. BOZEMAN, MT 59718 PROJECT LOCATION: 3717 EQUESTRIAN LN. BOZEMAN, MT 59718 LEGAL DESCRIPTION: LOT 7, BLOCK 16, BAXTER MEADOWS SUBDIVISION, PHASE 2A, LOCATED IN THE SE 1/4 SEC. 34, T. 1 S., R. 5 E. OF P.M.M., CITY OF BOZEMAN, GALLATIN COUNTY, MONTANA PROJECT DESCRIPTION: ADDITION ON AN EXISTING COMMERCIAL BUILDING APPLICABLE CODES: 2012 I.R.C., 2012 I.M.C., 2012 I.F.G.C., 2012 I.E.C.C., 2014 N.E.C. BUILDING SQUARE FOOTAGE: EXISTING AREA: 5,108 SQ. FT. ADDITION AREA: 2,105 SQ. FT. MEZZANINE AREA: 306 SQ. FT. TOTAL FINISHED AREA: 7,519 SQ. FT. CITY OF BOZEMAN ZONING CLASSIFICATION: B2 OCCUPANCY: B CONSTRUCTION TYPE: V-B Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS G-001 SHEET INDEX PROJECT DIRECTORY TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N RN & BE NE45 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 CIVIL Elevation Numbers Sheet Number ELEVATION INDICATOR: Section Number Sheet Number PARTIAL SECTION: Section Number Sheet Number DETAIL INDICATOR: Section Number Sheet Number BUILDING SECTION: Section Number Sheet Number SECTION DETAIL: DOOR OPENING: Wx H SYSTEM NOTE: KEYNOTE INDICATOR: WALL PANEL CENTERLINE: REVISION: ELEVATION MARK: DRAWING BLOCK: WINDOW LOUVER TYPE: Sheet Number Elevation Number Single View Multiple View DRAWING BLOCK TITLE DRAWING SCALE 2 CROSS REFERENCE 1 1 2 WALL PANEL TYPE: NORTH INDICATOR: P* LEVEL DESCRIPTOR ELEVATION HEIGHT EQUIPMENT INDICATOR: Section Number Sheet Number #L# _# # # 2 F=FLOOR, P=PARTITION W=WALL, C=CEILING, R=ROOF ARCHITECTURAL AS-101 ARCHITECTURAL SITE PLAN AS-102 LANDSCAPE PLAN A-001 ARCHITECTURAL FOUNDATION PLAN A-101 NEW OVERALL FLOOR PLAN A-102 NEW ADDITION FLOOR PLAN A-111 REFLECTED CEILING PLANS A-120 ADDITION ROOF PLAN A-201 OVERALL EXTERIOR ELEVATIONS A-202 ADDITION EXTERIOR ELEVATIONS A-203 ADDITION EXTERIOR ELEVATIONS A-204 COLORED EXTERIOR ELEVATIONS A-205 TRANSPARENCY CALCULATIONS A-301 BUILDING SECTIONS A-302 BUILDING SECTIONS A-303 BUILDING SECTIONS GENERAL G-001 SHEET INDEX PROJECT DIRECTORY THE PITT TRAINING FACILITY -ADDITION SITE PLAN REVIEW CORRECTIONS Project Directory Sheet Index Reference Symbols Architect: NE45 ARCHITECTURE 1216 W. Lincoln St., Suite D Bozeman, MT 59715 P: 406.577.2345 Tanner Skelton: tskelton@ne45arch.com Ben Erickson: berickson@ne45arch.com Owner: Exterior Materials Contractor: Mechanical: Electrical: Civil: Structural: Plumbing: Dane Fletcher 3717 Equestrian Lane Bozeman, MT 59718 Email upon request. PLAN NORTH P: 406.219.2383 PLAN NORTH SITE LOCATION CONTRACTOR TO COORDINATE WITH CONSULTANT CONTRACTOR TO COORDINATE WITH CONSULTANT CONTRACTOR TO COORDINATE WITH CONSULTANT 1091 Stoneridge Drive Bozeman, MT 59719 P: 406-587-1115 Timothy Staub: tstaub@chengineers.com C&H Engineering and Surveying, Inc. Langlas & Associates, Inc. 1019 E. Main St. #101 Bozeman, MT 59715 P: 406.585.3420 1289 Stonebridge Dr #1A Bozeman, MT 59718 P: 406.556.8600 Brian Zirbel: bzirbel@dci-engineers.com DCI + BCE Engineers, Inc. CONSTRUCTION ROUTE SITE LOCATION BOZEMAN CITY LIMITS (TYP.) SITE LOCATION B2 R4 R3 R3 PLI R3 R4 R4 R1 CITY OF BOZEMAN BOUNDARIES MAPS CITY OF BOZEMAN ZONING MAP Landscape: 300 Calico Dr., Unit D Bozeman, MT 59719 P: 406-587-3262 David Morrison: david@morrison-landscaping.com Morrison Design & Landscaping C1.0 EQUESTRIAN LANE CAB A L L O A V E . 1 DESCRIPTION DATE SITE PLAN REVIEW 4/22/19 SITE PLAN REVISIONS AND CORRECTIONS 5/23/19 OVERALL SITE PLAN AND PROJECT INFORMATION C1.1 OVERALL SITE PLAN AND PROJECT INFORMATION C1.2 DETAILS E-101 FLOOR PLAN ELECTRICAL LAYOUT DIAGRAM E-102 RCP ELECTRIAL LAYOUT DIAGRAM E-103 ELECTRICAL SCHEDULES AND ONE-LINE ELECTRICAL 02-20-2019 02-20-2019 02-20-2019 05-23-2019 04-22-2019 03-06-2019 03-06-2019 03-06-2019 02-26-2019 1 05-23-2019 05-23-2019 05-23-2019 05-23-2019 05-23-2019 05-23-2019 05-23-2019 05-23-2019 05-23-2019 05-23-2019 05-23-2019 05-23-2019 05-23-2019 2 PROPERTY SETBACK PROPERTY LINE 79.25' PROPERTY LINE 79.25' PROPERTY SETBACK AS-101 2 EXISTING BUILDING FOOTPRINT 5,107 SQ.FT. NEW BUILDING FOOTPRINT 2,314 SQ.FT. NEW CONCRETE WALKWAY NEW CONCRETE WALKWAY EXISTING TURF EXISTING TURF EX I S T I N G S I D E W A L K A N D FR O N T E N T R A N C E A P P R O A C H EXISTING TURF EXISTING TURF NEW LOCATION FOR TRASH ENCLOSURE AND TRASH BIN CA B A L L O A V E N U E EQUESTRIAN LANE PR O P E R T Y L I N E 1 6 5 . 0 0 ' PR O P E R T Y L I N E 1 6 5 . 0 0 ' EXISTING PLANTING BEDS AND PLANTING EXISTING PLANTING BEDS AND PLANTING EXISTING PLANTING BEDS AND PLANTING ALLEY C [N89 o41'57"E] 79.25 089 o41'57" [N 0 o 18 ' 0 3 " W ] 16 5 . 0 0 3 5 9 o 41 ' 5 7 " [S 0 o 18 ' 0 3 " E ] 16 5 . 0 0 1 7 9 o 41 ' 5 7 " [S89 o41'57"W] 79.25 269 o41'57" EXISTING SIDEWALK EXISTING ON-STREET PARKING EX I S T I N G O N - S T R E E T P A R K I N G EX I S T I N G O N - S T R E E T P A R K I N G EX I S T I N G S I D E W A L K PRIVATELY MAINTAINED EDGE OF ALLEY PAVEMENT 10' - 0" EDGE OF ALLEY PAVEMENT ROOF OVERHANG ABOVE EX I S T I N G O N - S T R E E T P A R K I N G ADJACENT LOT LINE VISION TRIANGLE BL O C K F R O N T A G E : M I X E D BLOCK FRONTAGE: MIXED ROOF OVERHANG ABOVE NEW ENTRY AND AWNING ABOVE 79' - 3" 1 6 5 ' - 0 " S E T B A C K 5 ' - 0 " SETBACK 5' - 0" R .O .W . 3 0 ' - 0 " C 3 A-301 3 A-301 BUILDING AREAS EXISTING = 5,107 SF NEW ADDITION = 2,314 SF MEZZANINE = 306 SF TOTAL = 7,728 SF LOT INFORMATION TOTAL LOT AREA = 13,076 SF (0.3 ACRES) TOTAL BUILDING FOOTPRINT = 7,421 SF LOT COVERAGE = 56% FAR TOTAL BUILDABLE AREA = 9,830 SF TOTAL GROSS SF = 7,728 SF FAR = 0.78 : 1 PARKING EXISTING ON-STREET PARKING = 23 SPACES ADA ACCESSIBLE PARKING = 2 SPACES Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS AS-101 ARCHITECTURAL SITE PLAN TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N RN & BE NE45 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 PLAN NORTH NOTE: THIS ARCHITECTURAL SITE PLAN IS FOR REFERENCE ONLY. REFER TO CIVIL AND LANDSCAPE DRAWINGS FOR GRADES, UTILITIES, DIMENSIONS AND DETAILS. 1" = 10'-0" NEW SITE PLAN - ARCHITECTURAL 1 SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION GENERAL SHEET NOTES 1. THIS ACHITECTURAL SITE PLAN IS FOR REFERENCE ONLY. REFER TO CIVIL AND LANDSCAPE DRAWINGS FOR GRADES, UTILITIES, DIMENSIONS AND DETAILS. 2. ALL UTILITIES MUST BE LOCATED BEFORE CONSTRUCTION BEGINS. REFER TO CIVIL AND MEP CONSULTANTS. 3 REFER TO CIVIL CONSULTANT DRAWINGS FOR ALL DRAINAGE AND GRADING. 4 ALL EXISTING PARKING AND SITE DEVELOPMENT TO REMAIN. ELEMENTS ARE SHOWN AS LIGHT GRAY. 1 MAIN ENTRY 2 EXTERIOR MECHANICAL EQUIPMENT LOCATION. PROVIDE MECHANICAL SCREENING PER THE BAXTER MEADOWS NEIGHBORHOOD CENTER DESIGN REVIEW BOARD. 3 PROPOSED TREE LOCATION. COORDINATE WITH CIVIL AND LANDSCAPING CONSULTANTS 4 PROPOSED PLANTER AND ORNAMENTAL GRAS; COORDINATE WITH CIVIL AND LANDSCAPING CONSULTANTS. 5 NEW CONCRETE SIDE WALK 6 CONCRETE PAD 7 OPTIONAL CONCRETE BENCH SEATING AREA. REFER TO STRUCTURAL FOR DETAILS. 8 SNOW STORAGE AREA 9 EXISTING EDGE OF CONCRETE 10 EXISTING PARKING SHEET KEYNOTES NUMBERING IS GROUPED BY TYPE / PHASE OF WORKSHEET OF NON-ARCHITECTURAL ITEMS OR INFORMATIONAL / INSTRUCTIONAL NOTATION. SOME NUMBERS MAY BE SKIPPED ON ANY GIVEN DRAWING SHEET. 1/2" = 1'-0" RELOCATED TRASH ENCLOSURE 2 EXISTING TRASH ENCLOSURE 4" SQUARE TUBE STEEL WITH CAP CORRUGATED GALVANIZED STEEL FENCING. TO MATCH THE VERTICAL METAL SIDING THROUGHOUT THE PROJECT PROJECT ACCESSIBILITY: THESE PLANS HAVE BEEN DESIGNED IN COMPLIANCE WITH THE ICC.A117.1 AND THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. ADDITIONAL ACCESSIBILITY REQUIREMENT MAY ALSO BE REQUIRED BY THE STATE OF LOCAL AUTHORITIES HAVING JURISDICTION. THE COMPLETE COMPLIANCE OF ACCESS TO ALL ADA REQUIREMENTS AREA DESIGNED INTO THE COMPLETION OF ALL PHASES OF THE PITT TRAINING FACILITY -ADDITION, INCLUDING EVERY ENTRY, ALL ACCESSIBLE PARKING SPACES AND ACCESSIBLE ROUTES TO THE MAIN ENTRANCE AND A PEDESTRIAN ACCESS PATH FROM THE FUTURE IMPROVEMENTS. 1 DESCRIPTION DATE SITE PLAN REVIEW 4/22/19 1 1 SYMBOL BOTANICAL NAME COMMON NAME SIZE TYPE SPACING #MATURE HEIGHT MATURE SPREAD BETULA PAPYRIFERA* MULTI STEM PAPER BIRCH 2.5" CAL B & B PER PLAN 2 40'-60' 25' PAP AMELANCHIER X ALNIFOLIA 'AUTUM BRILL' AUTUMN BRILLANCE SERVICEBERRY 25 GAL PER PLAN 6 15'-20' 15'-25'8' ACER TATARICUM*** TARTARIAN MAPLE B & B PER PLAN 2 15'-20' 15'-20'2.5" CAL TAT TREES SHRUBS PICEA PUNGENS GLOBOSA*** DWARF GLOBE SPRUCE 5 GAL POT PER PLAN 1 3'-4' 5'-6' EUONYMOUS ALATUS 'COMPACTUS' BURNING BUSH POT PER PLAN 9 6'-8' 5'-6'5 GAL PERENNIALS & GRASSES CALAMAGROSTIS X ACUTIFLORA*** KARL FOERESTER 1 GAL POT PER PLAN 17 3'-4'1.5'-2.5' HELICOTRICHON SEMPERVIVENS*** BLUE OAT GRASS POT PER PLAN 14 3' 2.5'-3'1 GAL OTHER PIPESTONE LANDSCAPE BOULDER, MIN 3' DIAMETER 9 1 1/2" WASHED LANDSCAPE ROCK LANDSCAPE SOD SF SF *** DROUGHT TOLERANT SPECIES * MODERATE DROUGHT TOLERANT SPECIES PLANT SCHEDULE LANDSCAPE POINTS - B2 ZONING 15 POINTS REQUIRED POINTS YARD DISTANCE COLUMN A COLUMN B NORTH 79' 2 LARGE NON-CANOPY TREES 6 DECIDUOUS SHRUBS 2 SMALL ORNAMENTAL TREES SOUTH 79' 4 SMALL ORNAMENTAL TREES 3 EVERGREEN SHRUBS 3 DECIDUOUS SHRUBS 6 DECIDUOUS SHRUBS TOTAL QTY REQUIRED 2 LARGE NON-CANOPY TREES 4 SMALL ORNAMENTAL TREES 15 DECIDUOUS SHRUBS 3 EVERGREEN SHRUBS 2 SMALL ORNAMENTAL TREES TOTAL QTY PROVIDED 2 LARGE NON-CANOPY TREES 4 SMALL ORNAMENTAL TREES 27 DECIDUOUS SHRUBS 3 EVERGREEN SHRUBS 2 SMALL ORNAMENTAL TREES GREATER THAN 50% AND LESS THAN 75% OF TREES AND SHRUBS ARE DROUGHT TOLERANT 1 POINT AWARDED FOR EACH STONE BOULDER NOT SMALLER THAN 3' IN DIAMETER WHICH IS INTEGRATED WITH OTHER LANDSCAPING - 5 PROVIDED 10 3 5 18 TOTAL LANDSCAPE POINTS STREET FRONTAGE LANDSCAPING REQUIRED: ONE LARGE CANOPY TREE FOR EVERY 50 FEET OF STREET FRONTAGE EAST YARD = 165' - 4 STREET TREES REQUIRED SOUTH YARD = 79' - 2 STREET TREES REQUIRED PROVIDED: 6 APPROVED STREET TREES IRRIGATION NOTES AND SPECIFICATIONS 1. ALL VALVE BOXES TO BE STANDARD SIZE OR LARGER 2. IRRIGATION MAIN LINE TO BE 2.5" SCH 40 PVC PIPE. 3. ALL SPRAY AND ROTOR IRRIGATION HEADS TO ACHIEVE HEAD TO HEAD COVERAGE. 4. ALL TREES TO BE IRRIGATED THROUGH DEDICATED BUBBLERS EVENLY DISTRIBUTED AROUND BASE OF TREE WITH THREE (3) EVENLY SPACED .25 GPM BUBBLER EMITTERS. TREE BUBBLER LATERALS AND VALVES ARE TO BE INSTALLED PER IRRIGATION CONTRACTOR DISCRETION AND VERIFIED BY LA. ALL TREES TO HAVE DEDICATED BUBBLER IRRIGATION INSTALLED PER IRRIGATION SPECIFICATIONS. 5. TREES AND SHRUBS PLACED WITHIN PLANTING BEDS AMY UTILIZE DRIP IRRIGATION ADJUSTED PER INDIVIDUAL PLANT REQUIREMENTS. 6. ALL SHRUBS OUTSIDE OF DEDICATED PLANTING BEDS TO HAVE DEDICATED BUBBLERS EVENLY DISTRIBUTED AROUND BASE, WITH TWO EVENLY SPACED .25 GPM EMITTERS. 7. ALL MIXED SHRUB AND PERENNIAL PLANTINGS TO BE IRRIGATED WITH DEDICATED DRIP TUBING EMITTERS ADJUSTED PER INDIVIDUAL PLANT REQUIREMENTS. LAWN AND SEED AREAS TO BE IRRIGATED WITH SPRAY OR ROTOR OVERHEARD IRRIGATION. ALL HEADS MUST ACHIEVE HEAD TO HEAD COVERAGE. 8. SYSTEM SHALL UTILIZE WEATHER/MOISTURE MONITOR. 9. BACKFLOW PREVENTOR AND BLOWOUT ASSEMBLY SHALL BE LOCATED IN MECH ROOM OR APPROVED EXTERNAL GRADEBOX, AND IS THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR TO COORDINATE INSTALLATION PER LOCAL CODES AND ORDINANCE WITH ARCHITECTURE AND ALL OTHER TRADES. 10. POWER SOURCE FOR IRRIGATION CONTROLLER TO BE COORDINATED WITH ELECTRICAL ENGINEERING AND ELECTRICAL CONTRACTION BY LANDSCAPE CONTRACTOR. 11. DO NOT INSTALL IRRIGATION SYSTEM WHEN OBVIOUS CONSTRUCTION OR GRADE CHANGES ARE PRESENT. 12. ALL INFORMATION TO BE FIELD VERIFIED BY CONTRACTOR PRIOR TO INSTALLATION. 13. CONTRACTOR RESPONSIBILITY TO CONFIRM WATER SOURCE, VERIFY WATER PRESSURE, GPM AVAILABLE. LANDSCAPE ARCHITECT TO BE NOTIFIED OF ANY DISCREPANCIES BETWEEN STATED WATER PRESSURE AND GPM AND ACTUAL. 14. PLAN IS DIAGRAMMATIC FOR PIPING AND LAYOUT. IRRIGATION CONTRACTOR MAY ADJUST PIPING AND LAYOUT AS NECESSARY. ALL PIPING AND VALVES TO BE IN LAWN AREA. 15. THE CONTRACTOR SHALL MAINTAIN AN ACCURATE & CURRENT 'AS-BUILT' IRRIGATION PLAN ON SITE AT ALL TIMES. 79' - 3" 1 6 5 ' - 0 " S E T B A C K 2 ' - 0 " SETBACK 10' - 0" S E T B A C K 1 0 ' - 0 " SETBACK 5' - 0" PROPERTY SETBACK PROPERTY LINE 79.25' PROPERTY LINE 79.25' PROPERTY SETBACK EXISTING BUILDING FOOTPRINT 5,107 SQ.FT. EXISTING TURF PR O P E R T Y L I N E 1 6 5 . 0 0 ' PR O P E R T Y L I N E 1 6 5 . 0 0 ' VISION TRIANGLE SNOW REMOVAL STORAGE OUTDOOR UTILITY, SITE PLANTS ACCORDINGLY TO AS BUILT PLACEMENT OF UTILITES AND A/C UNITS IN ORDER TO BEST PROVIDE SCREENING THREE (3) EXISTING BLUEPOINT JUNIPERS TO BE REPLACED AFTER CONSTRUCTION SEE C1.1 FOR EXTENTS OF STORMWATER RETENTION/DETENTION FACILITIES. 75 PERCENT OF SURFACE AREA MUST BE LINED WITH NATIVE GRASSES, WET ROOT TOLERANT PLANT TYPES, AND INDIGENOUS PLANTS. WETLAND TOLERANT SEED MIX SEE CIVIL S E E C I V I L WETLAND TOLERANT SEED MIX BOULDER INDIGENOUS, WETROOT TOLERANT SHRUBS AND TREES (TYP.) NOTE: SEE C1.1 FOR EXTENTS OF STORMWATER RETENTION/DETENTION FACILITIES. 75 PERCENT OF SURFACE AREA MUST BE LINED WITH NATIVE GRASSES, WET ROOT TOLERANT PLANT TYPES, AND INDIGENOUS PLANTS. Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS AS-102 LANDSCAPE PLAN TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N Checker Author 04-05-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 COORDINATE WITH LANDSCAPING FOR DEMO OF EXISTING IRRIGATION IRRIGATION LINES 1 DESCRIPTION DATE SITE PLAN REVIEW 4/22/19 PROPERTY OWNER: DANE FLETCHER 3717 EQUESTRIAN LANE 406-219-2383 LANDSCAPE PLAN PREPARED BY : DAVID MORRISON - MORRISON DESIGN AND LANDSCAPING 300 CALICO DR., UNIT D, BOZEMAN, MT 406-587-3262 1 1 1/4" = 1'-0" TYP. SECTION OF RETENTION FACILITY2 1 1 UP 4 A-201 1 A-201 3 A-201 1 1 2 2 4 4 3 3 B B C C E E F F 6' - 0" 38' - 0" 6' - 0" 2' - 0" AS-101 2 2 A-302 2 A-302 A-102 1 10' - 2" 13' - 4" 36' - 11" 1 A-202 2 A-202 2 A-203 RECOVERY ROOM 107 BATHROOM 2 106 BATHROOM 1 109 EXISTING BUILDING 1 A-302 1 A-302 D D 1 A-203 9' - 1 0 " 16 ' - 4 " 9' - 1 0 " NEW EXISTING NEW EXISTING 1 A-303 1 A-303 36 ' - 0 " ROOF OVERHANG ABOVE 1 1 A-204 3 A-204 2 A-204 52' - 0" 70 ' - 6 1 / 2 " 9' - 1 0 " 16 ' - 4 " 9' - 1 0 " 34 ' - 6 1 / 2 " C D E RELOCATE EXISTING TRASH ENCLOSURE 6 8' - 0" 6' - 0" 2' - 0" 6' - 0" 38' - 0" FLEX SPACE 103 MECH. 104 OFFICE 105 3 4 2 6 5 - - - - - - - - E-101 1 A A 5 5 2 A-303 2 A-303 3 A-303 3 A-303 1 A-205 Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-101 NEW OVERALL FLOOR PLAN TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N RN & BE NE45 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 1/8" = 1'-0" FLOOR PLAN1 SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION GENERAL SHEET NOTES 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITONS IN THE FIELD PRIOR TO CONSTRUCTION AND ORDERING MATERIALS. 2. EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR FACE OF STUD FRAMING / OUTSIDE FACE OF FOUNDATION. 3. INTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE AND FACE OF STUD FRAMING. 4. REFER TO ARCHITECTURAL SHEET G-001 AND SHEET SERIES 200 EXTERIOR ELEVATIONS FOR THE IDENTIFICATION OF VARIOUS EXTERIOR WALL VENEER MATERIAL TYPES, LOCATIONS AND EXTENT. 5. REFER TO ARCHITECTURAL INTERIOR ELEVATION SHEET SERIES A-210 FOR CASEWORK AND COUNTERTOP CONFIGURATIONS AND HEIGHTS. 6. REFER TO REFLECTED CEILING PLANS FOR WALL OPENINGS AT OR ABOVE 4'-0" A.F.F. 7. ALL FFE ITEMS ARE OWNER PROVIDE. 10. PROVIDE ACOUSTICAL INSULATION IN SURROUNDING RESTROOM WALLS - TYPICAL 11. PROVIDE WOOD BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, CASEWORK AND ACCESSORIES. NO EXCEPTIONS 12. PROVIDE 3/4" PLYWOOD – COMMUNICATIONS / ELECTRICAL ROOM MOUNTING BOARD 13. ALL INTERIOR FRAMED WALL SYSEM ASSEBMPLIES TO BE TYPE P6a, P4 AND P4ww. 15. AT ALL CORRIDORS, LOBBIES, STAIRS AND COMMONS. ALL EXPOSED PARTITION ENDS, OUTSIDE CORNERS, AND TRIMMED OPENINGS SHALL HAVE CORNER GUARDS (GYPSUM BOARD WALLS ONLY.) 16. ALL CORRIDOR GYPSUM BOARD FACED WALLS SHALL BE 5/8" FIBER REINFORCED IMPACT RESISTANT GYPSUM BOARD TO 8'-0" A.F.F. 18. SPECIFICATIONS REQUIRE AN INTERNAL CORNER EXPANSION JOINT AT ALL LOCATIONS IN MASONRY VENEERS 20. ISOLATE PERIMETER OF NON-BEARING WALL BOARD PARTITIONS ON SLAB ON GRADE AT INTERSECTIONS WITH EXTERIOR WALL AND/OR BEARING WALLS - PROVIDE 1/4" SPACE VERTICAL SLIP JOINT TRIM EDES WITH L-TYPE EDGE TRIM AND SEAL WITH ACOUSTIC SEALANT 21 THE CONTRACT DOCUMENTS ARE COMPLEMENTARY: THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. NOTIFY THE COR FOR RESOLUTION OF ALL DISCREPANCIES PROIR TO CONSTRUCTION. 22 LOCATE TYPICAL HINGE SIDE DOOR JAMB 4 - 4 1/2 INCHES FROM FINISH WALL TO EDGE OF DOOR OPENING. MAINTAIN A MINIMUM FINISHED CLEARANCE OF 18 INCHES TO THE STRIKE SIDE JAMB ON THE PULL SIDE OF ALL PUBLIC ACCESSIBLE DOORS. 23 LINE OF EXISTING GRADES, AS SHOWN ON THE BUILDING ELEVATIONS AND SECTIONS ARE APPROXIMATE. LINE OF EXISTING GRADES, AS SHOWN ON THE BUILDING ELEVATIONS AND 24 VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS CONTRACT, OR BY OTHERS. ALL EQUIPMENT TO BE SELECTED BY OWNER, CONTRACTOR AND CONSULTANTS. 25 REQUIRED FOR ACCESSORIES, MECHANICAL, ELECTRICAL AND OTHER FURRING, CURBS, ANCHORS AND INSERTS. PROVIDE ALL BASES AND BLOCKING REQUIRED OPENINGS THROUGH FLOORS AND WALLS, ACCESS DOORS, VERIFY SIZE/LOCATION/FINISH/FIRE-RATING, ETC. AND PROVIDE COMPLETE ALL REQUIRED OPENINGS THROUGH FLOORS AND WALLS, ACCESS DOORS, FURRING, CURBS, ANCHORS AND INSERTS. PROVIDE ALL BASES AND BLOCKING REQUIRED FOR ACCESSORIES, MECHANICAL, ELECTRICAL AND OTHER EQUIPMENT. 26 ALL EXTERIOR DRYVIT MUST FOLLOW MANUFACTURER INSTALLATION DETAILS AND SPECIFICATIONS. ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. COORDINATE WITH THE TEXTERIORS STORE WITH QUESTIONS. 27 ALL INTERIOR FLOORING MATERIAL FOR THE TRAINING FACILITY MUST FOLLOW THE MANUFACTURER INSTALLATION DETAILS AND SPECIFICATIONS. ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. COORDINATE WITH THE NEW ENGLAND TURF STORE WITH QUESTIONS. COLOR SELECTION BY OWNER 28 ALL ELECTRICAL OUTLET LOCATIONS ARE FOR REFERENCE ONLY. VERIFY LOCATIONS WITH AN ELECTRICAL ENGINEER CONSULTANT. 29 ALL STRUCTURAL ELEMENTS ARE FOR REFERENCE ONLY. REFER TO STRUCTURAL DRAWINGS. 31 REFER TO STRUCTURAL DRAWINGS FOR LOCATIONS OF SHEARWALL CONSTRUCTION WHERE PLYWOOD IS SUBSTITUTE FOR GYPSUM SHEATHING 32 PROVIDE MANUFACTURER STANDARD FLASHING DETAILS FOR ALL EXTERIOR DOORS AND STOREFRONT WINDOWS. 33 REFER TO SHEET SERIES A-600 FOR PROPOSED KAWNEER WINDOW AND DOOR INFORMATION. 35 ALL OUTLETS WITHIN 6' OF THE EDGE OF A SINK SHALL BE GFI PROTECTED PER NEC 210.8 (B) (5). PLAN NORTH 1 DESCRIPTION DATE BUILDING SQUARE FOOTAGE: EXISTING AREA: 5,108 SQ. FT. ADDITION AREA: 2,105 SQ. FT. MEZZANINE AREA: 306 SQ. FT. TOTAL FINISHED AREA: 7,519 SQ. FT . 4 A-201 1 1 2 2 4 4 3 3 B B C C E E F F 2 A-302 2 A-302 1 A-202 2 A-202 2 A-203 EXISTING BUILDING 1 A-302 1 A-302 2 A-301 2 A-301 D D 70 ' - 6 1 / 2 " 9' - 1 0 " 16 ' - 4 " 9' - 1 0 " 20 ' - 2 1 / 2 " 14 ' - 4 " A-210 7 A-601 1 A-210 8 A-210 2 3' - 0" 6' - 0" 38' - 0" 6' - 0" 2' - 0" 55' - 0" 6' - 4 1 / 2 " 3' - 5 1 / 2 " 13 ' - 1 " 3' - 3 " 4' - 2 1 / 2 " 5' - 5 " 2 1 / 2 " 4' - 7" 1' - 5" 8' - 0" 30' - 0" 14' - 0" 5' - 2" 13' - 8 1/2" 11' - 1 1/2" 2' - 7" C D 36 ' - 0 " 9' - 1 0 " 16 ' - 4 " 9' - 1 0 " E 6 4 A-210 3 W2 W2 W1 W1 W1 W1 W3 W3 W3 W3 W2 W2 W3 W3 W/D BY OWNER, PROVIDE HOOKUPS AND INSTALL 1 EX1 EXISTING DOOR TO REMAIN, REVERSE DOOR SWING EXISTING OVERHEAD DOOR TO REMAIN 1 A-203 6' - 0" 2' - 0" 52' - 0" BATHROOM 1 109 RECOVERY ROOM 107 BATHROOM 2 106 RECEPTION 102 W1 W1 W1 W1 W1 W1 W1.1 W1.1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 CEILING TRANSITION ABOVE EXISTING WALL FINISH TO REMAIN (TYP.) 1 A-301 1 A-301 3 4 1 RELOCATE EXISTING TRASH ENCLOSURE FLOOR TRANSITION (TYP.) A-211 12 9 REF ALL TRIM CONDITIONS TO MATCH EXISTING (TYP.) 11 10 LIMITS OF WORK NEW EXISTING NEW EXISTING 1 A-303 1 A-303 ROOF OVERHANG ABOVE 5 3 A-204 1' - 6 " 1' - 6 " EQ EQ 2 W3 W3 6 9' - 2 1 / 2 " 11 ' - 0 " FLEX SPACE 103 MECH. 104 OFFICE 105 NE W EX I S T I N G 2 6 6 FUR WALL AS NEEDED FOR W/D HOOKUPS LI M I T S O F W O R K LIMITS OF WORK EQ EQ 11 ' - 7 " 5 3 6 7' - 9 " BE N C H W / C U B B I E S COLD TUB, COORD. W/ OWNER AND MANUFACTURER W3 W3 W3 W3 W3 W3 W1 W1 EXISTING WALL FINISH TO REMAIN (TYP.) W1 W1 HOT TUB, COORD. W/ OWNER AND MANUFACTURER 7 - - - - - - ENTRY AWNING ABOVE A A 5 7 4 4 5 5 ALIGN DOOR W/ ENTRY DOOR 2 A-303 2 A-303 9' - 1" 4' - 11" C O O R D . W / S H O W E R I N S E R T 3 ' - 1 " SHOWER INSERT RAIN SHOWER HEAD SHOWER CURTAIN ROD 7 FIELD VERY EXISTING GRID LINES (TYP.) FIELD VERY EXISTING GRID LINES (TYP.) W2 W2 W1 W1 W3 W3 W2 W2 W1 W1 8 7 9 10 4 6 LAUNDRY 108 A B 8' - 11 1/2" TRAINING AREA 100 3 A-303 3 A-303 A-211 2 1 4 3 A-211 7 8 5 6 3 A-301 3 A-301 ALIGN WALL W/ MULLION OF WINDOW 4 ' - 0 " 6 ' - 4 " 4 ' - 0 " 1 A-205 WALK OFF CARPET FINISH FLOORING LEGEND COMMERCIAL CARPET TRAINING RUBBER FLOORING 1 TILE TRAINING RUBBER FLOORING 2 1 2 3 4 5 EXPOSED CONCRETE SLAB 6 *ALL FLOORING TO MATCH EXISTING WOOD COMPOSITE FLOORING 7 WALL TYPE LEGEND W1 EXTERIOR WALL -5/8" GWB., PAINT -BATT INSULATION, R-13 MIN. -2X6 WOOD STUDS, SSD -SHEATHING, SSD -AIR & WATER BARRIER -CONTINUOUS 1 1/2" RIGID INSULATION, R-7.5 MIN. -FINISH, SEE ELEVATIONS AND DETAILS W2 INTERIOR PARTITION WALL -5/8" GWB., PAINT -ACCOUSTIC INSULATION -2X6 WOOD STUDS, SSD -5/8" GWB., PAINT W3 INTERIOR PARTITION WALL -5/8" GWB., PAINT -ACCOUSTIC INSULATION -2X4 WOOD STUDS, SSD -5/8" GWB., PAINT W4 INTERIOR SHEATHED PARTITION WALL -5/8" GWB., PAINT -1/2" SHEATHING, SSD -ACCOUSTIC INSULATION -2X6 WOOD STUDS, SSD -1/2" SHEATHING, SSD -5/8" GWB., PAINT Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-102 NEW ADDITION FLOOR PLAN TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N Checker Author 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 1/4" = 1'-0" LEVEL 1 - ADDITION1 SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION GENERAL SHEET NOTES 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITONS IN THE FIELD PRIOR TO CONSTRUCTION AND ORDERING MATERIALS. 2. EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR FACE OF STUD FRAMING / OUTSIDE FACE OF FOUNDATION. 3. INTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE AND FACE OF STUD FRAMING. 4. REFER TO ARCHITECTURAL SHEET G-001 AND SHEET SERIES 200 EXTERIOR ELEVATIONS FOR THE IDENTIFICATION OF VARIOUS EXTERIOR WALL VENEER MATERIAL TYPES, LOCATIONS AND EXTENT. 5. REFER TO ARCHITECTURAL INTERIOR ELEVATION SHEET SERIES A-210 FOR CASEWORK AND COUNTERTOP CONFIGURATIONS AND HEIGHTS. 6. REFER TO REFLECTED CEILING PLANS FOR WALL OPENINGS AT OR ABOVE 4'-0" A.F.F. 7. ALL FFE ITEMS ARE OWNER PROVIDE. 10. PROVIDE ACOUSTICAL INSULATION IN SURROUNDING RESTROOM WALLS - TYPICAL 11. PROVIDE WOOD BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, CASEWORK AND ACCESSORIES. NO EXCEPTIONS 12. PROVIDE 3/4" PLYWOOD – COMMUNICATIONS / ELECTRICAL ROOM MOUNTING BOARD 13. ALL INTERIOR FRAMED WALL SYSEM ASSEBMPLIES TO BE TYPE P6a, P4 AND P4ww. 15. AT ALL CORRIDORS, LOBBIES, STAIRS AND COMMONS. ALL EXPOSED PARTITION ENDS, OUTSIDE CORNERS, AND TRIMMED OPENINGS SHALL HAVE CORNER GUARDS (GYPSUM BOARD WALLS ONLY.) 16. ALL CORRIDOR GYPSUM BOARD FACED WALLS SHALL BE 5/8" FIBER REINFORCED IMPACT RESISTANT GYPSUM BOARD TO 8'-0" A.F.F. 18. SPECIFICATIONS REQUIRE AN INTERNAL CORNER EXPANSION JOINT AT ALL LOCATIONS IN MASONRY VENEERS 20. ISOLATE PERIMETER OF NON-BEARING WALL BOARD PARTITIONS ON SLAB ON GRADE AT INTERSECTIONS WITH EXTERIOR WALL AND/OR BEARING WALLS - PROVIDE 1/4" SPACE VERTICAL SLIP JOINT TRIM EDES WITH L-TYPE EDGE TRIM AND SEAL WITH ACOUSTIC SEALANT 21 THE CONTRACT DOCUMENTS ARE COMPLEMENTARY: THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. NOTIFY THE COR FOR RESOLUTION OF ALL DISCREPANCIES PROIR TO CONSTRUCTION. 22 LOCATE TYPICAL HINGE SIDE DOOR JAMB 4 - 4 1/2 INCHES FROM FINISH WALL TO EDGE OF DOOR OPENING. MAINTAIN A MINIMUM FINISHED CLEARANCE OF 18 INCHES TO THE STRIKE SIDE JAMB ON THE PULL SIDE OF ALL PUBLIC ACCESSIBLE DOORS. 23 LINE OF EXISTING GRADES, AS SHOWN ON THE BUILDING ELEVATIONS AND SECTIONS ARE APPROXIMATE. LINE OF EXISTING GRADES, AS SHOWN ON THE BUILDING ELEVATIONS AND 24 VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS CONTRACT, OR BY OTHERS. ALL EQUIPMENT TO BE SELECTED BY OWNER, CONTRACTOR AND CONSULTANTS. 25 REQUIRED FOR ACCESSORIES, MECHANICAL, ELECTRICAL AND OTHER FURRING, CURBS, ANCHORS AND INSERTS. PROVIDE ALL BASES AND BLOCKING REQUIRED OPENINGS THROUGH FLOORS AND WALLS, ACCESS DOORS, VERIFY SIZE/LOCATION/FINISH/FIRE-RATING, ETC. AND PROVIDE COMPLETE ALL REQUIRED OPENINGS THROUGH FLOORS AND WALLS, ACCESS DOORS, FURRING, CURBS, ANCHORS AND INSERTS. PROVIDE ALL BASES AND BLOCKING REQUIRED FOR ACCESSORIES, MECHANICAL, ELECTRICAL AND OTHER EQUIPMENT. 26 ALL EXTERIOR DRYVIT MUST FOLLOW MANUFACTURER INSTALLATION DETAILS AND SPECIFICATIONS. ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. COORDINATE WITH THE TEXTERIORS STORE WITH QUESTIONS. 27 ALL INTERIOR FLOORING MATERIAL FOR THE TRAINING FACILITY MUST FOLLOW THE MANUFACTURER INSTALLATION DETAILS AND SPECIFICATIONS. ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. COORDINATE WITH THE NEW ENGLAND TURF STORE WITH QUESTIONS. COLOR SELECTION BY OWNER 28 ALL ELECTRICAL OUTLET LOCATIONS ARE FOR REFERENCE ONLY. VERIFY LOCATIONS WITH AN ELECTRICAL ENGINEER CONSULTANT. 29 ALL STRUCTURAL ELEMENTS ARE FOR REFERENCE ONLY. REFER TO STRUCTURAL DRAWINGS. 31 REFER TO STRUCTURAL DRAWINGS FOR LOCATIONS OF SHEARWALL CONSTRUCTION WHERE PLYWOOD IS SUBSTITUTE FOR GYPSUM SHEATHING 32 PROVIDE MANUFACTURER STANDARD FLASHING DETAILS FOR ALL EXTERIOR DOORS AND STOREFRONT WINDOWS. 33 REFER TO SHEET SERIES A-600 FOR PROPOSED KAWNEER WINDOW AND DOOR INFORMATION. 35 ALL OUTLETS WITHIN 6' OF THE EDGE OF A SINK SHALL BE GFI PROTECTED PER NEC 210.8 (B) (5). PLAN NORTH 1 DESCRIPTION DATE BUILDING SQUARE FOOTAGE: EXISTING AREA: 5,108 SQ. FT. ADDITION AREA: 2,105 SQ. FT. MEZZANINE AREA: 306 SQ. FT. TOTAL FINISHED AREA: 7,519 SQ. FT . CEILING SYMBOLS LEGEND REFER TO ENGINEERING MECHANICAL, ELECTRICAL, & FIRE PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION RECESSED DOWNLIGHT LUMINAIRE LIGHT FIXTURE PENDANT OR SURFACE STRIP OR INDUSTRIAL LUMINAIRE LIGHT FIXTURE RECESSED WALL WASHER LUMINAIRE LIGHT FIXTURE RECESSED DOWNLIGHT EMERGENCY LUMINAIRE LIGHT FIXTURE 4 A-201 1 1 2 2 4 4 3 3 B B C C E E F F 2 A-302 2 A-302 1 A-202 2 A-202 2 A-203 1 A-302 1 A-302 2 A-301 2 A-301 D D A-601 1 1 A-203 RECEPTION 102 RECOVERY ROOM 107 BATHROOM 2 106 EXISTING BUILDING TO REMAIN EXISTING NEW EXISTING NEW 1 A-301 1 A-301 CEILING TRANSITION 9' (+/-) CEILING HT. 9' (+/-) CEILING HT. 9' (+/-) CEILING HT. WOOD SOFFIT TO MATCH EXISTING (TYP.) NON-COMBUSTIBLE COMPOSITE SOFFIT WOOD SOFFIT AT AWNING TO MATCH EXISTING (TYP.) 1 A-303 1 A-303 GWB. PAINT (TYP.) 3 A-204 11' 6" (+/-) CEILING HT. 6 FLEX SPACE 103 MECH. 104 OFFICE 105 9' (+/-) CEILING HT. 9' (+/-) CEILING HT. 9' (+/-) CEILING HT. - - - - - - - - A A 5 5 2 A-303 2 A-303 3 A-303 3 A-303 A-211 2 1 4 3 A-211 7 8 5 6 3 A-301 3 A-301 BATHROOM 1 109 LAUNDRY 108 1 A-205 Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-111 REFLECTED CEILING PLANS TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N RN & BE NE45 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION GENERAL SHEET NOTES 1. EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR FACE OF STUDS / OUTSIDE FACE OF FOUNDATION U.N.O. 2. THIS PLAN SHOWS THE LOCATIONS OF ITEMS IN ARCHITECTURALLY SIGNIFICANT SPACES ONLY. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL PLANS FOR ALL ITEMS NOT SHOWN. 3. CENTER ALL CEILING FIXTURES IN ROOMS, UNLESS SHOWN OTHERWISE. 4. CENTER ALL CEILING MOUNTED ITEMS, GYPSUM BOARD SOFFITS, AND BETWEEN OTHER CEILING MOUNTED FIXTURES. SPEAKERS, SMOKE DETECTORS AND HEAT DETECTORS. 5. ALL CEILING ELEVATIONS REFERENCES ARE RELATIVE TO FINISHED FLOOR SLAB BELOW. 6. COORDINATE ACCESS PANEL AND DOOR LOCATIONS WITH OTHER CEILING MOUNTED ITEMS. 7. COORDINATE LIGHTING LAYOUTS IN UTILITY AND STORAGE ROOMS WITH OVER HEAD PIPING, DUCTS, AND EQUIPMENT. 8. COORDINATE POSITIONS OF ALL LIGHT FIXTURES, ACCESS PANELS, SUSPENDED PENDANTS, MECANICAL GRILLES, DIFFUSERS, AND REGISTERS TO AVOID AND ELIMINATE ANY AND ALL INTERFERENCES. 9. ALL SUSPENDED ACOUSTICAL CEILINGS AND GYPSUM BOARD CEILINGS OCCUR AT 9'-0" A.F.F. UNLESS OTHERWISE NOTED. 11. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR DEVICES AND REFER TO ARCHITECTURAL DRAWINGS FOR THE EXACT PLACEMENT OF DEVICES WITHIN CEILING GRIDS. 12. REFER TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE 13. ALL EXPOSED CEILING STRUCTURE AND DECK TO BE PAINTED. 14 EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR FACE OF STUDS / OUTSIDE FACE OF FOUNDATION U.N.O. 15 ALL INTERIOR AND EXTERIOR LIGHTS ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR TO VERIFY DIMENSIONS, INSTALLATION, SPECIFICATIONS AND DETAILS WITH ELECTRICAL/LIGHTING CONSULTANT. 16. INTERIOR CEILING PLAN DIMENSIONS ARE TO FACE OF STUD. NOTE: ALL INTERIOR AND EXTERIOR LIGHTS ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR TO VERIFY DIMENSIONS, INSTALLATION, SPECIFICATIONS AND DETAILS WITH ELECTRICAL/LIGHTING CONSULTANT. SPECIFIC TYPE OF LIGHT TO BE DETERMINED BY CONTRACTOR. 1/4" = 1'-0" REFLECTED CEILING PLAN - ADDITION2 1 DESCRIPTION DATE SITE PLAN REVIEW 4/22/19 1 4 A-201 1 1 2 2 4 4 3 3 B B C C E E F F 2 A-302 2 A-302 1 A-202 2 A-202 2 A-203 2' - 0" 2" / 1'-0" EXISTING BUILDING 1 A-302 1 A-302 2 A-301 2 A-301 D D 1 A-203 LIMITS OF WORK NEW EXISTING LIMITS OF WORK NEW EXISTING EDGE OF WALL BOUNDARY BELOW (TYP.) 2 ' - 0 " 2 ' - 0 " 3' - 0" EXISTING ROOF ABOVE 1 A-301 1 A-301 ASPHALT SHINGLE ROOF, TO MATCH EXISTING METAL GUTTER, TO MATCH EXISTING CRICKET AS NEEDED ICE AND WATER SHIELD, EXTEND 24" BEYOND BUILDING PERIMITER, MIN. (TYP.) A-120 2 ENTRY AWNING BELOW ROOF SLOPE TO MATCH EXISTING 1 A-303 1 A-303 3 A-204 2 ' - 0 " 6 MEMBRANE ROOF SLOPE TO GUTTER 1/4"/12" NE W EX I S T I N G - - - - - - A A 5 5 2 A-303 2 A-303 1' - 0" 2 ' - 0 " 3 A-303 3 A-303 1' - 0" 3 A-301 3 A-301 1 A-205 2 3 E F 2 A-302 2 A-302 3' - 6" ROOF OVERHANG ABOVE 1 6 ' - 4 " MEMBRANE ROOF SLOPE 1/4"/12" 1 A-303 1 A-303 Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-120 ADDITION ROOF PLAN TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N RN & BE NE45 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION GENERAL SHEET NOTES 1. PROVIDE MANUFACTURED GUTTER AND DOWNSPOUT SYSTEM AND PRECAST CONCRETE SPLASHBLOCK AT ALL STEEP SLOPED ROOF SYSTEM LOCATIONS U.N.O. 2. PROVIDE ROOFING MANUFACTURER STANDARD FLASHING DETAILS FOR ALL ROOF PENETRATIONS. 3. COORDINATE ROOF PENETRATION CURB AND FLASHING REQUIREMENTS WITH ALL AFFECTED TRADES. 4. ALL MECHANICAL EQUIPMENT LOCATIONS TO BE DETERMINED BY CONTRACTOR AND MECHANICAL CONSULTANT. ANY DIMENSIONS FOR MECHANICAL OPENING SUPPORT ARE BASED UPON INFORMATION PROVIDED BY SPECIFIED ROOF EQUIPMENT. COORDINATE SELECTED MANUFACTURER'S REQUIRED CLEAR OPENING WIDTH FOR ALL ROOF TOP EQUIPMENT WITH MECHANICAL COORDINATION SHOP DRAWINGS. 5. EXPOSED PIPING ON ROOF. REFER TO MECHANICAL AND PLUMBING PLANS FOR LOCATIONS AND EXTENT. 6. MAINTAIN FIRE-RATING AT MECHANICAL FLUE AND COMBUSTION AIR DUCT PENETRATIONS THROUGH ROOF/CEILING ASSEMBLY AT PLENUMS - REFER TO MECHANICAL CONSULTANT. 7. MAINTAIN ALL ROOF DRAINS CLEAN AND FREE-FLOWING DURING AND UPON COMPLETION OF CONSTRUCTION 8. METAL ROOF SYSTEM. REFER TO ROOFING CONSULTANT FOR COLOR, INSTALLATION AND SPECIFICATIONS. 9. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL CONSULTANT DRAWINGS FOR ROOF MOUNTED EQUIPMENT AND PENETRATIONS. NO EQUIPMENT PENETRATIONS ARE SHOWN ON THIS ROOF PLAN. 10. PAINT ALL ROOF TOP EQUIPMENT, ACCESSORIES, FLASHING, ETC. THAT IS NOT PAINTED OR FACTORY FINISHED TO MATCH THE METAL ROOF COLOR. 11 ARCHITECTURAL ROOF PLAN IS FOR REFERENCE ONLY. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITONS IN THE FIELD PRIOR TO CONSTRUCTION AND ORDERING MATERIALS. 1/4" = 1'-0" ROOF PLAN - ADDITION1 1/4" = 1'-0" ROOF PLAN - ENTRY AWNING2 1 DESCRIPTION DATE SITE PLAN REVIEW 4/22/19 1 1243 2 A-302 2 A-302 1 A-302 1 A-302 EXISTING NEW 1 T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" T.O. PLATE 2 (ADDITION) 111' -6" 2X4 WOOD SIDING, TO MATCH EXISTING DARK (1) GREY EIFS, TO MATCH EXISTING (TYP.) LIGHT GREY EIFS, TO MATCH EXISTING (TYP.) DARK (2) GREY EIFS BAND, TO MATCH EXISTING (TYP.) WOOD KNEE BRACE TO MATCH EXISTING 24-GAUGE CORRUGATED METAL SIDING, TO MATCH EXISTING (TYP.) METAL FASCIA, TO MATCH EXISTING STACKED CONCRETE MASONRY, TO MATCH EXISTING A D D I T I O N H T . (+/-) 2 1 ' - 5 " E X I S T I N G B U I L D I N G H T . (+/-) 2 7 ' - 1 1 /2 " 1 2 ' - 8 " 1 A-303 1 A-303 ALIGN BAND W/ EXISTING ALIGN JOINTS W/ EXISTING (TYP.) MATCH LIGHTING HT. W/ EXISTING (TYP.) 6 ARCHITECTURAL FOUNDATION PLAN 97' -6" 5 2 A-303 2 A-303 3 A-303 3 A-303 1 2 43 2 A-302 2 A-302 1 A-302 1 A-302 NEW EXISTING T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" T.O. PLATE 2 (ADDITION) 111' -6" RELOCATE EXISTING TRASH ENCLOSURE 1 A-303 1 A-303 6 6 NEW EXISTING ARCHITECTURAL FOUNDATION PLAN 97' -6" 5 2 A-303 2 A-303 3 A-303 3 A-303 CEFD E D C T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" T.O. PLATE 2 (ADDITION) 111' -6" DARK (1) GREY EIFS, TO MATCH EXISTING (TYP.) LIGHT GREY EIFS, TO MATCH EXISTING (TYP.) DARK (2) GREY EIFS BAND, TO MATCH EXISTING (TYP.) WOOD KNEE BRACE TO MATCH EXISTING VERTICAL 24-GAUGE CORRUGATED METAL SIDING, TO MATCH EXISTING (TYP.) HORIZONTAL 24-GAUGE CORRUGATED METAL SIDING, TO MATCH EXISTING (TYP.) 2" 1'-0" ARCHITECTURAL FOUNDATION PLAN 97' -6" A STACKED CONCRETE MASONARY UNIT. DARK GRAY FINISH. 2"X4" WOOD FINISH. STAINED FINISH. LIGHT COLOR EIFS FINISH. OUTSULATION® PLUS MD SYSTEM -CONTRACTOR TO FOLLOW EIFS MANUFACTURER'S INSTALLATION, SPECIFICATIONS AND DETAILS. VERTICAL 24-GAUGE CORRUGATED METAL SIDING. TYPICAL THROUGHOUT WITH A LIGHTER GRAY/BRIGHT SILVER FINISH. CONTRACTOR TO FOLLOW MANUFACTURER'S INSTALLATION, SPECIFICATIONS AND DETAILS. DARK GRAY EIFS FINISH. OUTSULATION® PLUS MD SYSTEM -CONTRACTOR TO FOLLOW EIFS MANUFACTURER'S INSTALLATION, SPECIFICATIONS AND DETAILS. HORIZONTAL 24-GAUGE CORRUGATED METAL SIDING. LOCATED ON THE BACK OF THE BUILDING. DARK/PEWTER GRAY FINISH. CONTRACTOR TO FOLLOW MANUFACTURER'S INSTALLATION, SPECIFICATIONS AND DETAILS. EIFS, LIGHT GREY WALL MATERIAL LEGEND EIFS, DARK GREY (1) EIFS, DARK GREY (2) 24-GAUGE CORRUGATED METAL CONCRETE MASONRY 2X4 WOOD SIDING *ALL FINISHES TO MATCH EXISTING Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-201 OVERALL EXTERIOR ELEVATIONS TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N RN & BE NE45 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION GENERAL SHEET NOTES 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITONS IN THE FIELD PRIOR TO CONSTRUCTION AND ORDERING MATERIALS. 2. SPECIFICATIONS REQUIRE AN INTERNAL CORNER EXPANSION JOINT AT ALL LOCATIONS IN MASONRY VENEERS 3. REFER TO ARCHITECTURAL FLOOR PLAN SHEETS FOR ALL WALL OPENING COMPONENT TYPES AND SHEET SERIES 600 FOR ALL WALL OPENING COMPONENT CONFIGURATIONS AND DIMENSIONS. 4. WALL CONTROL / EXPANSION JOINT DESIGNATIONS CJ=CONTROL JOINT AT CMU WALLS EJ=EXPANSION JOINT AT FACING BRICK 5 PROVIDE MANUFACTURER STANDARD FLASHING DETAILS FOR ALL EXTERIOR DOORS AND STOREFRONT WINDOWS. 6 CONTRACTOR WILL FOLLOW MANUFACTURER'S INSTALLATION, SPECIFICATIONS AND DETAILS FOR ALL WINDOWS, DOORS AND EXTERIOR MATERIALS. 1/8" = 1'-0" EAST EXTERIOR ELEVATION 1 1/8" = 1'-0" WEST EXTERIOR ELEVATION 3 1/8" = 1'-0" NORTH EXTERIOR ELEVATION 4 1 DESCRIPTION DATE 1243 2 A-302 2 A-302 1 A-302 1 A-302 T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" T.O. PLATE 2 (ADDITION) 111' -6" 2X4 WOOD SIDING, TO MATCH EXISTING DARK (1) GREY EIFS, TO MATCH EXISTING (TYP.) LIGHT GREY EIFS, TO MATCH EXISTING (TYP.) DARK (2) GREY EIFS BAND, TO MATCH EXISTING (TYP.) WOOD KNEE BRACE TO MATCH EXISTING VERTICAL 24-GAUGE CORRUGATED METAL SIDING, TO MATCH EXISTING (TYP.) METAL FASCIA, TO MATCH EXISTING A L I G N W / E X I S T I N G ALIGN ALL HORIZONTAL JOINT LINES WITH EXISTING (TYP.) STACKED CONCRETE MASONRY, TO MATCH EXISTING TYP. 2' - 0" TYP. 5' - 10" TYP. 2' - 0" 1 WOOD SOFFIT, TO MATCH EXISTING 2 0 ' - 1 0 1 /2 " (+/-) 1 2 ' - 8 " NEW EXISTING FRONT AWNING, TO MATCH EXISTING 1 A-303 1 A-303 STOREFRONT TO MATCH EXISTING 1' - 10" 1' - 10" 1' - 10" 1' - 10" 2' - 0" 2' - 0" PROPOSED SIGNAGE 8'-0" x 4'-0" 32 SF TOTAL BUILDING MASSING AND ARTICULATION FEATURES (ENTRY, MATERIAL, AND MODULATION) 36' - 5" (+/-) 3 A-303 3 A-303 CEF 2 A-301 2 A-301 D E D C T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" 1 A-301 1 A-301 T.O. PLATE 2 (ADDITION) 111' -6" DARK (1) GREY EIFS, TO MATCH EXISTING (TYP.) LIGHT GREY EIFS, TO MATCH EXISTING (TYP.) DARK (2) GREY EIFS BAND, TO MATCH EXISTING (TYP.) WOOD KNEE BRACE TO MATCH EXISTING VERTICAL 24-GAUGE CORRUGATED METAL SIDING, TO MATCH EXISTING (TYP.) METAL J TRIM TO MATCH EXISTING ALIGN VERTICAL JOINTS W/ WINDOW EDGES METAL FASCIA, TO MATCH EXISTING ALIGN ALL HORIZONTAL JOINT LINES W/ EXISTING (TYP.) 1 2 ' - 8 " 2" 1'-0" HORIZONTAL 24-GAUGE CORRUGATED METAL SIDING, TO MATCH EXISTING ROOFTOP MECH. EQUIPMENT BY CONTRACTOR, MATCH SCREEN TO EXISTING METAL PARAPET CAP BUILDING MASSING AND ARTICULATION FEATURE (MATERIAL) BUILDING MASSING AND ARTICULATION FEATURE (WINDOWS AND ARTICULATION) A 3 A-301 3 A-301 EIFS, LIGHT GREY WALL MATERIAL LEGEND EIFS, DARK GREY (1) EIFS, DARK GREY (2) 24-GAUGE CORRUGATED METAL CONCRETE MASONRY 2X4 WOOD SIDING *ALL FINISHES TO MATCH EXISTING BOZEMAN MUNICIPAL CODE Expand Existing Footpring 38% Level II Improvement Building Massing and Articulation Facade Articulation (features located every 60') North Facade 1) Windows 6) Material 7) Articulation West Facade 1) Windows 7) Articulation *3 features not required per Exception 10 East Facade 2) Entry 6) Material 10) Modulation Max Facade Width Any facade exceeding 150'-0" requires a massing break North - South Facade = 55'-0" (+/-) East - West Facade = 37'-0" (+/-) No massing break is required for these facades Landscape Block Frontage Standards Facade Transparency 150 sf between 4'-0" and 8'-0" 37.5 sf required 53 sf provided Weather Protection 3' deep weather protection required 3'-6" provided SIGNAGE Maximum sq. ft. area 400 sf per lot Allowed per linear ft of building frontage first 25 ft 75 sf Allowed per linear ft of building frontage >25ft 181 sf Total Allowed Signage sf (lesser of the two) 256 sf Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-202 ADDITION EXTERIOR ELEVATIONS TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N Checker Author 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 1/4" = 1'-0" EAST EXTERIOR ELEVATION - ADDITION1 1/4" = 1'-0" NORTH EXTERIOR ELEVATION2 1 DESCRIPTION DATE B C E F 2 A-301 2 A-301 D T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" 1 A-301 1 A-301 T.O. PLATE 2 (ADDITION) 111' -6" 2" 1'-0" EXISTING BUILDING 2" 1'-0" ARCHITECTURAL FOUNDATION PLAN 97' -6" A 3 A-301 3 A-301 1 2 43 2 A-302 2 A-302 1 A-302 1 A-302 T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" T.O. PLATE 2 (ADDITION) 111' -6" RELOCATE EXISTING TRASH ENCLOSURE HORRIZONTAL 24-GAUGE CORRUGATED METAL TO MATCH EXISTING EXISTING NEW ASPHALT SHINGLE ROOF, TO MATCH EXISTING 1 A-303 1 A-303 6 6 APPROXIMATE LOCATION OF UTILITY METER; CONTRACTOR TO COORDINATE EXISTING NEW EXISTING NEW 70' - 4 3/4" 5 2 A-303 2 A-303 3 A-303 3 A-303 EIFS, LIGHT GREY WALL MATERIAL LEGEND EIFS, DARK GREY (1) EIFS, DARK GREY (2) 24-GAUGE CORRUGATED METAL CONCRETE MASONRY 2X4 WOOD SIDING *ALL FINISHES TO MATCH EXISTING BOZEMAN MUNICIPAL CODE Expand Existing Footpring 38% Level II Improvement Building Massing and Articulation Facade Articulation (features located every 60') North Facade 1) Windows 6) Material 7) Articulation West Facade 1) Windows 7) Articulation *3 features not required per Exception 10 East Facade 2) Entry 6) Material 10) Modulation Max Facade Width Any facade exceeding 150'-0" requires a massing break North - South Facade = 55'-0" (+/-) East - West Facade = 37'-0" (+/-) No massing break is required for these facades Landscape Block Frontage Standards Facade Transparency 150 sf between 4'-0" and 8'-0" 37.5 sf required 53 sf provided Weather Protection 3' deep weather protection required 3'-6" provided SIGNAGE Maximum sq. ft. area 400 sf per lot Allowed per linear ft of building frontage first 25 ft 75 sf Allowed per linear ft of building frontage >25ft 181 sf Total Allowed Signage sf (lesser of the two) 256 sf Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-203 ADDITION EXTERIOR ELEVATIONS TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N Checker Author 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 1/4" = 1'-0" SOUTH EXTERIOR ELEVATION1 1/4" = 1'-0" WEST EXTERIOR ELEVATION2 1 DESCRIPTION DATE EXISTING NEW 2X4 WOOD SIDING, TO MATCH EXISTING DARK (1) GREY EIFS, TO MATCH EXISTING (TYP.) LIGHT GREY EIFS, TO MATCH EXISTING (TYP.) DARK (2) GREY EIFS BAND, TO MATCH EXISTING (TYP.) WOOD KNEE BRACE TO MATCH EXISTING 24-GAUGE CORRUGATED METAL SIDING, TO MATCH EXISTING (TYP.) METAL FASCIA, TO MATCH EXISTING STACKED CONCRETE MASONRY, TO MATCH EXISTING WOOD T&G SOFFIT, TO MATCH EXISTING (TYP.) ALIGN BAND W/ EXISTING ALIGN JOINTS W/ EXISTING (TYP.) MATCH LIGHTING HT. W/ EXISTING (TYP.) DARK (1) GREY EIFS, TO MATCH EXISTING (TYP.) LIGHT GREY EIFS, TO MATCH EXISTING (TYP.) DARK (2) GREY EIFS BAND, TO MATCH EXISTING (TYP.) WOOD KNEE BRACE TO MATCH EXISTING 24-GAUGE CORRUGATED METAL SIDING, TO MATCH EXISTING (TYP.) 24-GAUGE CORRUGATED METAL SIDING, TO MATCH EXISTING (TYP.) NEW EXISTING 24-GAUGE CORRUGATED METAL SIDING, TO MATCH EXISTING (TYP.) NEW EXISTING Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-204 COLORED EXTERIOR ELEVATIONS TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N Checker Author 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 1/8" = 1'-0" COLORED EAST EXTERIOR ELEVATION 1 1/8" = 1'-0" COLORED NORTH EXTERIOR ELEVATION 3 1/8" = 1'-0" COLORED WEST EXTERIOR ELEVATION 2 WOOD T&G SOFFIT CORRUGATED METAL SIDING STACKED CONCRETE MASONRY 1 DESCRIPTION DATE EIFS 1243 T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" T.O. PLATE 2 (ADDITION) 111' -6" 13'-4" x 4'-0" = 53 SF of Transparency 36'-5" x 4'-0" = 146 SF of Non -Transparent Material 53 SF of Transparency 146 SF of Non-Transparent Material = 36% Facade Transparency 4 ' - 0 " 4 ' - 0 " 8 ' - 0 " 36' - 5" BOZEMAN MUNICIPAL CODE Expand Existing Footpring 38% Level II Improvement Building Massing and Articulation Facade Articulation (features located every 60') North Facade 1) Windows 6) Material 7) Articulation West Facade 1) Windows 7) Articulation *3 features not required per Exception 10 East Facade 2) Entry 6) Material 10) Modulation Max Facade Width Any facade exceeding 150'-0" requires a massing break North - South Facade = 55'-0" (+/-) East - West Facade = 37'-0" (+/-) No massing break is required for these facades Landscape Block Frontage Standards Facade Transparency 150 sf between 4'-0" and 8'-0" 37.5 sf required 53 sf provided Weather Protection 3' deep weather protection required 3'-6" provided SIGNAGE Maximum sq. ft. area 400 sf per lot Allowed per linear ft of building frontage first 25 ft 75 sf Allowed per linear ft of building frontage >25ft 181 sf Total Allowed Signage sf (lesser of the two) 256 sf EIFS, LIGHT GREY WALL MATERIAL LEGEND EIFS, DARK GREY (1) EIFS, DARK GREY (2) 24-GAUGE CORRUGATED METAL CONCRETE MASONRY 2X4 WOOD SIDING *ALL FINISHES TO MATCH EXISTING Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-205 TRANSPARENCY CALCULATIONS TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N NE45 NE45 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 1 DESCRIPTION DATE SITE PLAN REVIEW 4/22/19 1/4" = 1'-0" EAST EXTERIOR ELEVATION - TRANSPARENCY CALCULATIONS 1 1 1243 2 A-302 2 A-302 1 A-302 1 A-302 T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" T.O. PLATE 2 (ADDITION) 111' -6" NEW EXISTING 1 1 ' - 6 " 1 A-303 1 A-303 1 A-311 ARCHITECTURAL FOUNDATION PLAN 97' -6" 1 2 43 2 A-302 2 A-302 1 A-302 1 A-302 T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" T.O. PLATE 2 (ADDITION) 111' -6" 1 1 ' - 6 " 1 A-303 1 A-303 ARCHITECTURAL FOUNDATION PLAN 97' -6" Level 1 100' -0" Level 2 110' -0" 1 2 43 2 A-302 2 A-302 1 A-302 1 A-302 T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" T.O. PLATE 2 (ADDITION) 111' -6" 1 A-303 1 A-303 6 ARCHITECTURAL FOUNDATION PLAN 97' -6" 5 2 A-303 2 A-303 3 A-303 3 A-303 ALIGN WALL W/ MULLION OF WINDOW Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-301 BUILDING SECTIONS TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N RN & BE NE45 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 GENERAL SHEET NOTES 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITONS IN THE FIELD PRIOR TO CONSTRUCTION AND ORDERING MATERIALS. 2. EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR FACE OF STUD FRAMING / OUTSIDE FACE OF FOUNDATION. 3. INTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE AND FACE OF STUD FRAMING. 4. REFER TO ARCHITECTURAL FLOOR PLAN SHEETS FOR ALL WALL OPENINGS, COMPONENT TYPES AND SHEET SERIES A-600 FOR ALL WALL OPENING COMPONENT CONFIGURATIONS AND DIMENSIONS. 5 REFER TO ROOF PLAN FOR ROOF SLOPES. 6 REFER TO STRUCTURAL DRAWINGS FOR ALL FRAMING, FOUNDATION, TRUSSES AND OTHER STRUCTURAL ELEMENTS. 1/4" = 1'-0" BUILDING SECTION 2 11/4" = 1'-0" BUILDING SECTION 3 2 1 DESCRIPTION DATE 1/4" = 1'-0" BUILDING SECTION 8 3 BCEF 2 A-301 2 A-301 D T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" 1 A-301 1 A-301 BATHROOM 1 109 T.O. PLATE 2 (ADDITION) 111' -6" EXISTING FINISHES TO REMAIN EXISTING FINISHES TO REMAIN ARCHITECTURAL FOUNDATION PLAN 97' -6" A 3 A-301 3 A-301 B C E F 2 A-301 2 A-301 D T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" 1 A-301 1 A-301 RECOVERY ROOM 107 T.O. PLATE 2 (ADDITION) 111' -6" T.O. PLATE 2 (ADDITION) 111' -6" 1 1 ' - 6 " 1 2 ' - 8 " 2 A-310 3 A-310 ARCHITECTURAL FOUNDATION PLAN 97' -6" A H E E L H T . 2 ' - 6 " H E E L H T . 8 ' - 4 " (+/-) 3 A-301 3 A-301 TRAINING AREA 100 Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-302 BUILDING SECTIONS TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N Checker Author 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 1/4" = 1'-0" BUILDING SECTION 4 1 1/4" = 1'-0" BUILDING SECTION 5 2 1 DESCRIPTION DATE B C E F 2 A-301 2 A-301 D T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" 1 A-301 1 A-301 T.O. PLATE 2 (ADDITION) 111' -6" 1 1 ' - 6 " BATHROOM 2 106 4 A-310 ARCHITECTURAL FOUNDATION PLAN 97' -6" A 3 A-301 3 A-301 B C T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" 1 A-301 1 A-301 T.O. PLATE 2 (ADDITION) 111' -6" ARCHITECTURAL FOUNDATION PLAN 97' -6" A 3 A-301 3 A-301 B C T.O. PLATE 1 (ADDITION) 109' -0" T.O. SLAB 100' -0" T.O. PLATE 2 (ADDITION) 111' -6" ARCHITECTURAL FOUNDATION PLAN 97' -6" A MECH. 104 3 A-301 3 A-301 Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-303 BUILDING SECTIONS TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N Checker Author 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 1/4" = 1'-0" BUILDING SECTION 6 1 1 DESCRIPTION DATE 1/4" = 1'-0" BUILDING SECTION 1 2 1/4" = 1'-0" BUILDING SECTION 7 3 1 1 2 2 4 4 3 3 A A B B D D E E C C 5 EXISTING BUILDING 71 ' - 6 1 / 2 " 10 ' - 4 " 16 ' - 4 " 10 ' - 4 " 34 ' - 6 1 / 2 " 9' - 0" 38' - 0" 6' - 0" 2' - 0" 55' - 0" 9' - 4 1 / 2 " 11 1 / 2 " 13 ' - 0 1 / 2 " 3' - 3 1 / 2 " 5' - 8 1 / 2 " 4' - 5 " 2 1 / 2 " 5' - 4" 16' - 0" 16' - 8" 4' - 3 1/2" 4' - 8 1/2" 7' - 10" 8' - 2" 5' - 9" 10' - 11" 1" C D E 37 ' - 0 " 10 ' - 4 " 16 ' - 4 " 10 ' - 4 " F 6' - 0" 2' - 0" 55' - 0" THERAPY 100 CONFERENCE 107 OFFICE 106 RECOVERY ROOM 103 BATH 102 BATH 101 RECEPTION 108 REF NEW EXISTING NEW EXISTING ROOF OVERHANG ABOVE 1' - 6 " 1' - 6 " EQ EQ 13 ' - 3 1 / 2 " 10 ' - 3 " 11 ' - 0 " LAUNDRY/STORAGE 109 MECH. 110 OFFICE 111 NE W EX I S T I N G 2 6 LI M I T S O F W O R K LIMITS OF WORK BENCH COLD TUB A B HOT TUB Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS REVISION DATE 3-7-16 E-101 FLOOR PLAN ELECTRICAL LAYOUT DIAGRAM TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N 02-11-2019 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 1 DESCRIPTION DATE 1/4" = 1'-0" LEVEL 1 - ADDITION - ELECTRIAL LAYOUT DIAGRAM1 GF I 240V 30A GFI GFI GFI W P G F I $m FUR-1CU-1 208/330A G F I GF I +60" G F I G F I UCREF G F I G F I G F I G F I Cold Tub Hot Tub WP GF I GFI GFI $m HRVInAttic 120V 20A 208V 3PH20A EDH-1 Existing 400Amp Service to be Removed G F I TC TC 1 1 2 2 4 4 3 3 A A B B D D E E C C CABINETS AND FRAMING BELOW 5 OFFICE 106 CONFERENCE 107 RECOVERY ROOM 103 BATH 102 BATH 101 LAUNDRY/STORAGE 109 MECH. 110 OFFICE 111 EXISTING BUILDING Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS REVISION DATE 3-7-16 E-102 RCP ELECTRICAL LAYOUT DIAGRAM TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N 02-11-2019 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 1 DESCRIPTION DATE 1/4" = 1'-0" ELECTRICAL LAYOUT DIAGRAM1 D H RR R R R R R RR R R R R R R R R R R VFVF R R R RR R R R R R RR R R R R H H H H H H D D R R R4R4 R4 R4 R4 R4 R4 R4 R4 R4 J R R RRIIII I I I I I I I $$ $OC $OC $OC $OC $D$D $$ $D $D $D $3$3 $3$3$3 $3 $ $3 $3 $F ER EER EER ER E EM EM EM EM F F W W W TIE ONTO EXISTING CIRCUIT FEED FROM TIME CLOCK AND PHOTCELL Lighting on with receptacles Lighting on with receptacles TC TC F A A A A A A Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS REVISION DATE 3-7-16 TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N 02-11-2019 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 1 DESCRIPTION DATE 1 ELECTRICAL SCHEDULES AND ONE-LINE DIAGRAM ELECTICAL SHEDULES AND ONE-LINE E-103 PANEL A 120/208VOLT 3 PHASE 200 AMP UTILITY METER 120/208VOLT 3 PHASE 400A 200A 200A AHU-1 120/208VOLT 3 PHASE 200 AMP "EXISTING" PANEL A 120/208VOLT 3 PHASE 200 AMP "EXISTING" AHU-1 120/208VOLT 3 PHASE 200 AMP EXISTING METER TO BE REMOVED AND FEEDERS TO BE RE-FEED "NEW" PANEL B 120/208VOLT 3 PHASE 200 AMP UTILITY CT CAN 120/208VOLT 3 PHASE 600A 36"Hx36"Wx12"D UTILITY METER SOCKET "NEW" MDP 120/208VOLT 3 PHASE 600 AMP 3R InteriorExterior InteriorExterior TC TC