HomeMy WebLinkAboutAS-102 LANDSCAPE PLAN 05-23-19SYMBOL BOTANICAL NAME
COMMON NAME SIZE TYPE SPACING #MATURE
HEIGHT
MATURE
SPREAD
BETULA PAPYRIFERA*
MULTI STEM PAPER BIRCH 2.5" CAL B & B PER PLAN 2 40'-60' 25'
PAP
AMELANCHIER X ALNIFOLIA 'AUTUM BRILL'
AUTUMN BRILLANCE SERVICEBERRY 25 GAL PER PLAN 6 15'-20' 15'-25'8'
ACER TATARICUM***
TARTARIAN MAPLE B & B PER PLAN 2 15'-20' 15'-20'2.5" CAL
TAT
TREES
SHRUBS
PICEA PUNGENS GLOBOSA***
DWARF GLOBE SPRUCE 5 GAL POT PER PLAN 1 3'-4' 5'-6'
EUONYMOUS ALATUS 'COMPACTUS'
BURNING BUSH POT PER PLAN 9 6'-8' 5'-6'5 GAL
PERENNIALS & GRASSES
CALAMAGROSTIS X ACUTIFLORA***
KARL FOERESTER 1 GAL POT PER PLAN 17 3'-4'1.5'-2.5'
HELICOTRICHON SEMPERVIVENS***
BLUE OAT GRASS POT PER PLAN 14 3' 2.5'-3'1 GAL
OTHER
PIPESTONE LANDSCAPE BOULDER,
MIN 3' DIAMETER 9
1 1/2" WASHED LANDSCAPE ROCK
LANDSCAPE SOD
SF
SF
*** DROUGHT TOLERANT SPECIES
* MODERATE DROUGHT TOLERANT SPECIES
PLANT SCHEDULE
LANDSCAPE POINTS - B2 ZONING 15 POINTS REQUIRED
POINTS YARD DISTANCE COLUMN A COLUMN B
NORTH 79' 2 LARGE NON-CANOPY TREES 6 DECIDUOUS SHRUBS
2 SMALL ORNAMENTAL TREES
SOUTH 79' 4 SMALL ORNAMENTAL TREES 3 EVERGREEN SHRUBS
3 DECIDUOUS SHRUBS
6 DECIDUOUS SHRUBS
TOTAL QTY
REQUIRED
2 LARGE NON-CANOPY TREES
4 SMALL ORNAMENTAL TREES
15 DECIDUOUS SHRUBS
3 EVERGREEN SHRUBS
2 SMALL ORNAMENTAL TREES
TOTAL QTY
PROVIDED
2 LARGE NON-CANOPY TREES
4 SMALL ORNAMENTAL TREES
27 DECIDUOUS SHRUBS
3 EVERGREEN SHRUBS
2 SMALL ORNAMENTAL TREES
GREATER THAN 50% AND LESS THAN 75% OF TREES AND SHRUBS ARE DROUGHT
TOLERANT
1 POINT AWARDED FOR EACH STONE BOULDER NOT SMALLER THAN 3' IN DIAMETER
WHICH IS INTEGRATED WITH OTHER LANDSCAPING - 5 PROVIDED
10
3
5
18 TOTAL LANDSCAPE POINTS
STREET FRONTAGE LANDSCAPING
REQUIRED: ONE LARGE CANOPY TREE FOR EVERY 50 FEET OF STREET FRONTAGE
EAST YARD = 165' - 4 STREET TREES REQUIRED
SOUTH YARD = 79' - 2 STREET TREES REQUIRED
PROVIDED: 6 APPROVED STREET TREES
IRRIGATION NOTES AND SPECIFICATIONS
1. ALL VALVE BOXES TO BE STANDARD SIZE OR LARGER
2. IRRIGATION MAIN LINE TO BE 2.5" SCH 40 PVC PIPE.
3. ALL SPRAY AND ROTOR IRRIGATION HEADS TO ACHIEVE HEAD TO HEAD COVERAGE.
4. ALL TREES TO BE IRRIGATED THROUGH DEDICATED BUBBLERS EVENLY DISTRIBUTED AROUND BASE OF TREE WITH
THREE (3) EVENLY SPACED .25 GPM BUBBLER EMITTERS. TREE BUBBLER LATERALS AND VALVES ARE TO BE INSTALLED
PER IRRIGATION CONTRACTOR DISCRETION AND VERIFIED BY LA. ALL TREES TO HAVE DEDICATED BUBBLER IRRIGATION
INSTALLED PER IRRIGATION SPECIFICATIONS.
5. TREES AND SHRUBS PLACED WITHIN PLANTING BEDS AMY UTILIZE DRIP IRRIGATION ADJUSTED PER INDIVIDUAL PLANT
REQUIREMENTS.
6. ALL SHRUBS OUTSIDE OF DEDICATED PLANTING BEDS TO HAVE DEDICATED BUBBLERS EVENLY DISTRIBUTED AROUND
BASE, WITH TWO EVENLY SPACED .25 GPM EMITTERS.
7. ALL MIXED SHRUB AND PERENNIAL PLANTINGS TO BE IRRIGATED WITH DEDICATED DRIP TUBING EMITTERS ADJUSTED
PER INDIVIDUAL PLANT REQUIREMENTS. LAWN AND SEED AREAS TO BE IRRIGATED WITH SPRAY OR ROTOR OVERHEARD
IRRIGATION. ALL HEADS MUST ACHIEVE HEAD TO HEAD COVERAGE.
8. SYSTEM SHALL UTILIZE WEATHER/MOISTURE MONITOR.
9. BACKFLOW PREVENTOR AND BLOWOUT ASSEMBLY SHALL BE LOCATED IN MECH ROOM OR APPROVED EXTERNAL
GRADEBOX, AND IS THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR TO COORDINATE INSTALLATION PER LOCAL
CODES AND ORDINANCE WITH ARCHITECTURE AND ALL OTHER TRADES.
10. POWER SOURCE FOR IRRIGATION CONTROLLER TO BE COORDINATED WITH ELECTRICAL ENGINEERING AND ELECTRICAL
CONTRACTION BY LANDSCAPE CONTRACTOR.
11. DO NOT INSTALL IRRIGATION SYSTEM WHEN OBVIOUS CONSTRUCTION OR GRADE CHANGES ARE PRESENT.
12. ALL INFORMATION TO BE FIELD VERIFIED BY CONTRACTOR PRIOR TO INSTALLATION.
13. CONTRACTOR RESPONSIBILITY TO CONFIRM WATER SOURCE, VERIFY WATER PRESSURE, GPM AVAILABLE. LANDSCAPE
ARCHITECT TO BE NOTIFIED OF ANY DISCREPANCIES BETWEEN STATED WATER PRESSURE AND GPM AND ACTUAL.
14. PLAN IS DIAGRAMMATIC FOR PIPING AND LAYOUT. IRRIGATION CONTRACTOR MAY ADJUST PIPING AND LAYOUT AS
NECESSARY. ALL PIPING AND VALVES TO BE IN LAWN AREA.
15. THE CONTRACTOR SHALL MAINTAIN AN ACCURATE & CURRENT 'AS-BUILT' IRRIGATION PLAN ON SITE AT ALL TIMES.
79' - 3"
1 6 5 ' - 0 "
S E T B A C K
2 ' - 0 "
SETBACK
10' - 0"
S E T B A C K
1 0 ' - 0 "
SETBACK
5' - 0"
PROPERTY SETBACK
PROPERTY LINE 79.25'
PROPERTY LINE 79.25'
PROPERTY SETBACK
EXISTING BUILDING FOOTPRINT
5,107 SQ.FT.
EXISTING TURF
PR
O
P
E
R
T
Y
L
I
N
E
1
6
5
.
0
0
'
PR
O
P
E
R
T
Y
L
I
N
E
1
6
5
.
0
0
'
VISION
TRIANGLE
SNOW
REMOVAL
STORAGE
OUTDOOR UTILITY, SITE
PLANTS ACCORDINGLY
TO AS BUILT PLACEMENT
OF UTILITES AND A/C
UNITS IN ORDER TO BEST
PROVIDE SCREENING
THREE (3) EXISTING
BLUEPOINT JUNIPERS TO
BE REPLACED AFTER
CONSTRUCTION
SEE C1.1 FOR EXTENTS OF
STORMWATER
RETENTION/DETENTION
FACILITIES. 75 PERCENT OF
SURFACE AREA MUST BE
LINED WITH NATIVE
GRASSES, WET ROOT
TOLERANT PLANT TYPES,
AND INDIGENOUS PLANTS.
WETLAND TOLERANT
SEED MIX
SEE CIVIL
S E E C I V I L
WETLAND TOLERANT
SEED MIX
BOULDER
INDIGENOUS, WETROOT
TOLERANT SHRUBS AND
TREES (TYP.)
NOTE: SEE C1.1 FOR EXTENTS OF
STORMWATER RETENTION/DETENTION
FACILITIES. 75 PERCENT OF SURFACE
AREA MUST BE LINED WITH NATIVE
GRASSES, WET ROOT TOLERANT
PLANT TYPES, AND INDIGENOUS
PLANTS.
Date
Drawn By
Checked By:
Project Number
Sheet Name
Copyright:
ALL DRAWN AND WRITTEN INFORMATION
APPEARING SHALL NOT BE DUPLICATED,
DISCLOSED OR OTHERWISE USED
WITHOUT THE WRITTEN CONSENT OF
NE45 ARCHITECTURE
Issued
CONSTRUCTION DRAWINGS
AS-102
LANDSCAPE PLAN
TH
E
P
I
T
T
T
R
A
I
N
I
N
G
FA
C
I
L
I
T
Y
-
A
D
D
I
T
I
O
N
Checker
Author
04-05-19
18017
37
1
7
E
Q
U
E
S
T
R
I
A
N
L
N
.
BO
Z
E
M
A
N
,
M
T
5
9
7
1
8
COORDINATE WITH LANDSCAPING
FOR DEMO OF EXISTING IRRIGATION
IRRIGATION LINES
1 DESCRIPTION DATE
SITE PLAN REVIEW 4/22/19
PROPERTY OWNER:
DANE FLETCHER
3717 EQUESTRIAN LANE
406-219-2383
LANDSCAPE PLAN PREPARED BY :
DAVID MORRISON - MORRISON DESIGN AND LANDSCAPING
300 CALICO DR., UNIT D, BOZEMAN, MT
406-587-3262
1
1
1/4" = 1'-0"
TYP. SECTION OF RETENTION FACILITY2
1
1