HomeMy WebLinkAboutA-202 ADDITION EXTERIOR ELEVATIONS 05-23-191243
2
A-302
2
A-302
1
A-302
1
A-302
T.O. PLATE 1
(ADDITION)
109' -0"
T.O. SLAB
100' -0"
T.O. PLATE 2
(ADDITION)
111' -6"
2X4 WOOD
SIDING, TO
MATCH
EXISTING
DARK (1) GREY EIFS, TO
MATCH EXISTING (TYP.)
LIGHT GREY EIFS, TO
MATCH EXISTING (TYP.)
DARK (2) GREY EIFS
BAND, TO MATCH
EXISTING (TYP.)
WOOD KNEE
BRACE TO MATCH
EXISTING
VERTICAL 24-GAUGE
CORRUGATED METAL
SIDING, TO MATCH
EXISTING (TYP.)
METAL FASCIA, TO
MATCH EXISTING
A L I G N W / E X I S T I N G
ALIGN ALL HORIZONTAL
JOINT LINES WITH
EXISTING (TYP.)
STACKED CONCRETE
MASONRY, TO MATCH
EXISTING
TYP.
2' - 0"
TYP.
5' - 10"
TYP.
2' - 0"
1
WOOD SOFFIT, TO
MATCH EXISTING
2 0 ' - 1 0 1 /2 " (+/-)
1 2 ' - 8 "
NEW EXISTING
FRONT AWNING, TO
MATCH EXISTING
1
A-303
1
A-303
STOREFRONT TO
MATCH EXISTING
1' - 10" 1' - 10" 1' - 10" 1' - 10"
2' - 0" 2' - 0"
PROPOSED SIGNAGE
8'-0" x 4'-0"
32 SF TOTAL
BUILDING MASSING AND
ARTICULATION FEATURES (ENTRY,
MATERIAL, AND MODULATION)
36' - 5" (+/-)
3
A-303
3
A-303
CEF
2
A-301
2
A-301
D
E D C
T.O. PLATE 1
(ADDITION)
109' -0"
T.O. SLAB
100' -0"
1
A-301
1
A-301
T.O. PLATE 2
(ADDITION)
111' -6"
DARK (1) GREY EIFS, TO
MATCH EXISTING (TYP.)
LIGHT GREY EIFS, TO
MATCH EXISTING (TYP.)
DARK (2) GREY
EIFS BAND, TO
MATCH EXISTING
(TYP.)
WOOD KNEE
BRACE TO MATCH
EXISTING
VERTICAL 24-GAUGE
CORRUGATED METAL
SIDING, TO MATCH
EXISTING (TYP.)
METAL J TRIM TO
MATCH EXISTING
ALIGN VERTICAL
JOINTS W/ WINDOW
EDGES
METAL FASCIA, TO
MATCH EXISTING
ALIGN ALL
HORIZONTAL JOINT
LINES W/ EXISTING
(TYP.)
1 2 ' - 8 "
2"
1'-0"
HORIZONTAL 24-GAUGE
CORRUGATED METAL SIDING,
TO MATCH EXISTING
ROOFTOP MECH.
EQUIPMENT BY
CONTRACTOR, MATCH
SCREEN TO EXISTING
METAL PARAPET CAP
BUILDING MASSING AND
ARTICULATION FEATURE
(MATERIAL)
BUILDING MASSING AND
ARTICULATION FEATURE
(WINDOWS AND ARTICULATION)
A
3
A-301
3
A-301
EIFS, LIGHT GREY
WALL MATERIAL LEGEND
EIFS, DARK GREY (1)
EIFS, DARK GREY (2)
24-GAUGE CORRUGATED METAL
CONCRETE MASONRY
2X4 WOOD SIDING
*ALL FINISHES TO MATCH EXISTING
BOZEMAN MUNICIPAL CODE
Expand Existing Footpring 38% Level II Improvement
Building Massing and Articulation
Facade Articulation (features located every 60')
North Facade 1) Windows
6) Material
7) Articulation
West Facade 1) Windows
7) Articulation
*3 features not required per Exception 10
East Facade 2) Entry
6) Material
10) Modulation
Max Facade Width
Any facade exceeding 150'-0" requires a massing break
North - South Facade = 55'-0" (+/-)
East - West Facade = 37'-0" (+/-)
No massing break is required for these facades
Landscape Block Frontage Standards
Facade Transparency 150 sf between 4'-0" and 8'-0"
37.5 sf required
53 sf provided
Weather Protection 3' deep weather protection required
3'-6" provided
SIGNAGE
Maximum sq. ft. area 400 sf per lot
Allowed per linear ft of building frontage first 25 ft 75 sf
Allowed per linear ft of building frontage >25ft 181 sf
Total Allowed Signage sf (lesser of the two) 256 sf
Date
Drawn By
Checked By:
Project Number
Sheet Name
Copyright:
ALL DRAWN AND WRITTEN INFORMATION
APPEARING SHALL NOT BE DUPLICATED,
DISCLOSED OR OTHERWISE USED
WITHOUT THE WRITTEN CONSENT OF
NE45 ARCHITECTURE
Issued
CONSTRUCTION DRAWINGS
A-202
ADDITION
EXTERIOR
ELEVATIONS
TH
E
P
I
T
T
T
R
A
I
N
I
N
G
FA
C
I
L
I
T
Y
-
A
D
D
I
T
I
O
N
Checker
Author
05-23-19
18017
37
1
7
E
Q
U
E
S
T
R
I
A
N
L
N
.
BO
Z
E
M
A
N
,
M
T
5
9
7
1
8
1/4" = 1'-0"
EAST EXTERIOR ELEVATION - ADDITION1
1/4" = 1'-0"
NORTH EXTERIOR ELEVATION2
1 DESCRIPTION DATE