HomeMy WebLinkAboutA-120 ADDITION ROOF PLAN 05-23-194
A-201
1 1
2 2
4 4
3 3
B
B
C
C
E
E
F
F
2
A-302
2
A-302
1
A-202
2
A-202
2
A-203
2' - 0"
2" / 1'-0"
EXISTING BUILDING
1
A-302
1
A-302
2
A-301
2
A-301
D
D
1
A-203
LIMITS OF WORK NEW
EXISTING
LIMITS OF WORK NEW
EXISTING
EDGE OF WALL
BOUNDARY BELOW (TYP.)
2 ' - 0 "
2 ' - 0 "
3' - 0"
EXISTING
ROOF
ABOVE
1
A-301
1
A-301
ASPHALT SHINGLE ROOF, TO
MATCH EXISTING
METAL GUTTER,
TO MATCH
EXISTING
CRICKET AS
NEEDED
ICE AND WATER SHIELD, EXTEND 24"
BEYOND BUILDING PERIMITER, MIN.
(TYP.)
A-120
2
ENTRY AWNING BELOW
ROOF SLOPE TO MATCH EXISTING
1
A-303
1
A-303
3
A-204
2 ' - 0 "
6
MEMBRANE ROOF
SLOPE TO
GUTTER 1/4"/12"
NE
W
EX
I
S
T
I
N
G
-
-
-
-
-
-
A
A
5 5
2
A-303
2
A-303
1' - 0"
2 ' - 0 "
3
A-303
3
A-303
1' - 0"
3
A-301
3
A-301
1
A-205
2
3
E F
2
A-302
2
A-302
3' - 6"
ROOF
OVERHANG
ABOVE
1 6 ' - 4 "
MEMBRANE ROOF
SLOPE
1/4"/12"
1
A-303
1
A-303
Date
Drawn By
Checked By:
Project Number
Sheet Name
Copyright:
ALL DRAWN AND WRITTEN INFORMATION
APPEARING SHALL NOT BE DUPLICATED,
DISCLOSED OR OTHERWISE USED
WITHOUT THE WRITTEN CONSENT OF
NE45 ARCHITECTURE
Issued
CONSTRUCTION DRAWINGS
A-120
ADDITION ROOF
PLAN
TH
E
P
I
T
T
T
R
A
I
N
I
N
G
FA
C
I
L
I
T
Y
-
A
D
D
I
T
I
O
N
RN & BE
NE45
05-23-19
18017
37
1
7
E
Q
U
E
S
T
R
I
A
N
L
N
.
BO
Z
E
M
A
N
,
M
T
5
9
7
1
8
SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION
GENERAL SHEET NOTES
1. PROVIDE MANUFACTURED GUTTER AND DOWNSPOUT SYSTEM AND PRECAST
CONCRETE SPLASHBLOCK AT ALL STEEP SLOPED ROOF SYSTEM LOCATIONS U.N.O.
2. PROVIDE ROOFING MANUFACTURER STANDARD FLASHING DETAILS FOR ALL ROOF
PENETRATIONS.
3. COORDINATE ROOF PENETRATION CURB AND FLASHING REQUIREMENTS WITH ALL
AFFECTED TRADES.
4. ALL MECHANICAL EQUIPMENT LOCATIONS TO BE DETERMINED BY CONTRACTOR
AND MECHANICAL CONSULTANT. ANY DIMENSIONS FOR MECHANICAL OPENING
SUPPORT ARE BASED UPON INFORMATION PROVIDED BY SPECIFIED ROOF
EQUIPMENT. COORDINATE SELECTED MANUFACTURER'S REQUIRED CLEAR
OPENING WIDTH FOR ALL ROOF TOP EQUIPMENT WITH MECHANICAL
COORDINATION SHOP DRAWINGS.
5. EXPOSED PIPING ON ROOF. REFER TO MECHANICAL AND PLUMBING PLANS FOR
LOCATIONS AND EXTENT.
6. MAINTAIN FIRE-RATING AT MECHANICAL FLUE AND COMBUSTION AIR DUCT
PENETRATIONS THROUGH ROOF/CEILING ASSEMBLY AT PLENUMS - REFER TO
MECHANICAL CONSULTANT.
7. MAINTAIN ALL ROOF DRAINS CLEAN AND FREE-FLOWING DURING AND UPON
COMPLETION OF CONSTRUCTION
8. METAL ROOF SYSTEM. REFER TO ROOFING CONSULTANT FOR COLOR,
INSTALLATION AND SPECIFICATIONS.
9. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL CONSULTANT DRAWINGS
FOR ROOF MOUNTED EQUIPMENT AND PENETRATIONS. NO EQUIPMENT
PENETRATIONS ARE SHOWN ON THIS ROOF PLAN.
10. PAINT ALL ROOF TOP EQUIPMENT, ACCESSORIES, FLASHING, ETC. THAT IS NOT
PAINTED OR FACTORY FINISHED TO MATCH THE METAL ROOF COLOR.
11 ARCHITECTURAL ROOF PLAN IS FOR REFERENCE ONLY. THE CONTRACTOR SHALL
VERIFY ALL DIMENSIONS AND CONDITONS IN THE FIELD PRIOR TO CONSTRUCTION
AND ORDERING MATERIALS.
1/4" = 1'-0"
ROOF PLAN - ADDITION1
1/4" = 1'-0"
ROOF PLAN - ENTRY AWNING2
1 DESCRIPTION DATE
SITE PLAN REVIEW 4/22/19
1