HomeMy WebLinkAboutA-111 REFLECTED CEILING PLANS 05-23-19CEILING SYMBOLS LEGEND REFER TO ENGINEERING MECHANICAL, ELECTRICAL, & FIRE PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION RECESSED DOWNLIGHT LUMINAIRE LIGHT FIXTURE PENDANT OR SURFACE STRIP OR INDUSTRIAL LUMINAIRE LIGHT FIXTURE RECESSED WALL WASHER LUMINAIRE LIGHT FIXTURE RECESSED DOWNLIGHT EMERGENCY LUMINAIRE LIGHT FIXTURE 4 A-201 1 1 2 2 4 4 3 3 B B C C E E F F 2 A-302 2 A-302 1 A-202 2 A-202 2 A-203 1 A-302 1 A-302 2 A-301 2 A-301 D D A-601 1 1 A-203 RECEPTION 102 RECOVERY ROOM 107 BATHROOM 2 106 EXISTING BUILDING TO REMAIN EXISTING NEW EXISTING NEW 1 A-301 1 A-301 CEILING TRANSITION 9' (+/-) CEILING HT. 9' (+/-) CEILING HT. 9' (+/-) CEILING HT. WOOD SOFFIT TO MATCH EXISTING (TYP.) NON-COMBUSTIBLE COMPOSITE SOFFIT WOOD SOFFIT AT AWNING TO MATCH EXISTING (TYP.) 1 A-303 1 A-303 GWB. PAINT (TYP.) 3 A-204 11' 6" (+/-) CEILING HT. 6 FLEX SPACE 103 MECH. 104 OFFICE 105 9' (+/-) CEILING HT. 9' (+/-) CEILING HT. 9' (+/-) CEILING HT. - - - - - - - - A A 5 5 2 A-303 2 A-303 3 A-303 3 A-303 A-211 2 1 4 3 A-211 7 8 5 6 3 A-301 3 A-301 BATHROOM 1 109 LAUNDRY 108 1 A-205 Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-111 REFLECTED CEILING PLANS TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N RN & BE NE45 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION GENERAL SHEET NOTES 1. EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR FACE OF STUDS / OUTSIDE FACE OF FOUNDATION U.N.O. 2. THIS PLAN SHOWS THE LOCATIONS OF ITEMS IN ARCHITECTURALLY SIGNIFICANT SPACES ONLY. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL PLANS FOR ALL ITEMS NOT SHOWN. 3. CENTER ALL CEILING FIXTURES IN ROOMS, UNLESS SHOWN OTHERWISE. 4. CENTER ALL CEILING MOUNTED ITEMS, GYPSUM BOARD SOFFITS, AND BETWEEN OTHER CEILING MOUNTED FIXTURES. SPEAKERS, SMOKE DETECTORS AND HEAT DETECTORS. 5. ALL CEILING ELEVATIONS REFERENCES ARE RELATIVE TO FINISHED FLOOR SLAB BELOW. 6. COORDINATE ACCESS PANEL AND DOOR LOCATIONS WITH OTHER CEILING MOUNTED ITEMS. 7. COORDINATE LIGHTING LAYOUTS IN UTILITY AND STORAGE ROOMS WITH OVER HEAD PIPING, DUCTS, AND EQUIPMENT. 8. COORDINATE POSITIONS OF ALL LIGHT FIXTURES, ACCESS PANELS, SUSPENDED PENDANTS, MECANICAL GRILLES, DIFFUSERS, AND REGISTERS TO AVOID AND ELIMINATE ANY AND ALL INTERFERENCES. 9. ALL SUSPENDED ACOUSTICAL CEILINGS AND GYPSUM BOARD CEILINGS OCCUR AT 9'-0" A.F.F. UNLESS OTHERWISE NOTED. 11. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR DEVICES AND REFER TO ARCHITECTURAL DRAWINGS FOR THE EXACT PLACEMENT OF DEVICES WITHIN CEILING GRIDS. 12. REFER TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE 13. ALL EXPOSED CEILING STRUCTURE AND DECK TO BE PAINTED. 14 EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR FACE OF STUDS / OUTSIDE FACE OF FOUNDATION U.N.O. 15 ALL INTERIOR AND EXTERIOR LIGHTS ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR TO VERIFY DIMENSIONS, INSTALLATION, SPECIFICATIONS AND DETAILS WITH ELECTRICAL/LIGHTING CONSULTANT. 16. INTERIOR CEILING PLAN DIMENSIONS ARE TO FACE OF STUD. NOTE: ALL INTERIOR AND EXTERIOR LIGHTS ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR TO VERIFY DIMENSIONS, INSTALLATION, SPECIFICATIONS AND DETAILS WITH ELECTRICAL/LIGHTING CONSULTANT. SPECIFIC TYPE OF LIGHT TO BE DETERMINED BY CONTRACTOR. 1/4" = 1'-0" REFLECTED CEILING PLAN - ADDITION2 1 DESCRIPTION DATE SITE PLAN REVIEW 4/22/19 1