HomeMy WebLinkAboutA-111 REFLECTED CEILING PLANS 05-23-19CEILING SYMBOLS LEGEND
REFER TO ENGINEERING MECHANICAL, ELECTRICAL, & FIRE PROTECTION
DRAWINGS FOR ADDITIONAL INFORMATION
RECESSED DOWNLIGHT LUMINAIRE LIGHT FIXTURE
PENDANT OR SURFACE STRIP OR INDUSTRIAL LUMINAIRE LIGHT
FIXTURE
RECESSED WALL WASHER LUMINAIRE LIGHT FIXTURE
RECESSED DOWNLIGHT EMERGENCY LUMINAIRE LIGHT FIXTURE
4
A-201
1 1
2 2
4 4
3 3
B
B
C
C
E
E
F
F
2
A-302
2
A-302
1
A-202
2
A-202
2
A-203
1
A-302
1
A-302
2
A-301
2
A-301
D
D
A-601 1
1
A-203
RECEPTION
102
RECOVERY
ROOM
107
BATHROOM 2
106
EXISTING BUILDING TO REMAIN
EXISTING
NEW
EXISTING
NEW
1
A-301
1
A-301
CEILING TRANSITION
9' (+/-) CEILING HT.
9' (+/-) CEILING HT.
9' (+/-) CEILING HT.
WOOD SOFFIT TO
MATCH EXISTING
(TYP.)
NON-COMBUSTIBLE
COMPOSITE SOFFIT
WOOD SOFFIT AT
AWNING TO MATCH
EXISTING (TYP.)
1
A-303
1
A-303
GWB. PAINT (TYP.)
3
A-204
11' 6" (+/-) CEILING HT.
6
FLEX SPACE
103
MECH.
104
OFFICE
105
9' (+/-) CEILING HT.
9' (+/-) CEILING HT.
9' (+/-) CEILING HT.
-
-
-
-
-
-
-
-
A
A
5 5
2
A-303
2
A-303
3
A-303
3
A-303
A-211
2
1
4
3
A-211
7
8
5
6
3
A-301
3
A-301
BATHROOM 1
109
LAUNDRY
108
1
A-205
Date
Drawn By
Checked By:
Project Number
Sheet Name
Copyright:
ALL DRAWN AND WRITTEN INFORMATION
APPEARING SHALL NOT BE DUPLICATED,
DISCLOSED OR OTHERWISE USED
WITHOUT THE WRITTEN CONSENT OF
NE45 ARCHITECTURE
Issued
CONSTRUCTION DRAWINGS
A-111
REFLECTED
CEILING PLANS
TH
E
P
I
T
T
T
R
A
I
N
I
N
G
FA
C
I
L
I
T
Y
-
A
D
D
I
T
I
O
N
RN & BE
NE45
05-23-19
18017
37
1
7
E
Q
U
E
S
T
R
I
A
N
L
N
.
BO
Z
E
M
A
N
,
M
T
5
9
7
1
8
SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION
GENERAL SHEET NOTES
1. EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR FACE OF
STUDS / OUTSIDE FACE OF FOUNDATION U.N.O.
2. THIS PLAN SHOWS THE LOCATIONS OF ITEMS IN ARCHITECTURALLY SIGNIFICANT
SPACES ONLY. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL PLANS FOR
ALL ITEMS NOT SHOWN.
3. CENTER ALL CEILING FIXTURES IN ROOMS, UNLESS SHOWN OTHERWISE.
4. CENTER ALL CEILING MOUNTED ITEMS, GYPSUM BOARD SOFFITS, AND BETWEEN
OTHER CEILING MOUNTED FIXTURES. SPEAKERS, SMOKE DETECTORS AND HEAT
DETECTORS.
5. ALL CEILING ELEVATIONS REFERENCES ARE RELATIVE TO FINISHED FLOOR SLAB
BELOW.
6. COORDINATE ACCESS PANEL AND DOOR LOCATIONS WITH OTHER CEILING
MOUNTED ITEMS.
7. COORDINATE LIGHTING LAYOUTS IN UTILITY AND STORAGE ROOMS WITH OVER
HEAD PIPING, DUCTS, AND EQUIPMENT.
8. COORDINATE POSITIONS OF ALL LIGHT FIXTURES, ACCESS PANELS, SUSPENDED
PENDANTS, MECANICAL GRILLES, DIFFUSERS, AND REGISTERS TO AVOID AND
ELIMINATE ANY AND ALL INTERFERENCES.
9. ALL SUSPENDED ACOUSTICAL CEILINGS AND GYPSUM BOARD CEILINGS OCCUR AT
9'-0" A.F.F. UNLESS OTHERWISE NOTED.
11. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR DEVICES AND
REFER TO ARCHITECTURAL DRAWINGS FOR THE EXACT PLACEMENT OF DEVICES
WITHIN CEILING GRIDS.
12. REFER TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE
13. ALL EXPOSED CEILING STRUCTURE AND DECK TO BE PAINTED.
14 EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR FACE OF
STUDS / OUTSIDE FACE OF FOUNDATION U.N.O.
15 ALL INTERIOR AND EXTERIOR LIGHTS ARE SHOWN FOR REFERENCE ONLY.
CONTRACTOR TO VERIFY DIMENSIONS, INSTALLATION, SPECIFICATIONS AND
DETAILS WITH ELECTRICAL/LIGHTING CONSULTANT.
16. INTERIOR CEILING PLAN DIMENSIONS ARE TO FACE OF STUD.
NOTE: ALL INTERIOR AND EXTERIOR LIGHTS ARE
SHOWN FOR REFERENCE ONLY. CONTRACTOR TO
VERIFY DIMENSIONS, INSTALLATION, SPECIFICATIONS
AND DETAILS WITH ELECTRICAL/LIGHTING
CONSULTANT. SPECIFIC TYPE OF LIGHT TO BE
DETERMINED BY CONTRACTOR.
1/4" = 1'-0"
REFLECTED CEILING PLAN - ADDITION2
1 DESCRIPTION DATE
SITE PLAN REVIEW 4/22/19
1