Loading...
HomeMy WebLinkAboutA-102 NEW ADDITION FLOOR PLAN 05-23-194 A-201 1 1 2 2 4 4 3 3 B B C C E E F F 2 A-302 2 A-302 1 A-202 2 A-202 2 A-203 EXISTING BUILDING 1 A-302 1 A-302 2 A-301 2 A-301 D D 70 ' - 6 1 / 2 " 9' - 1 0 " 16 ' - 4 " 9' - 1 0 " 20 ' - 2 1 / 2 " 14 ' - 4 " A-210 7 A-601 1 A-210 8 A-210 2 3' - 0" 6' - 0" 38' - 0" 6' - 0" 2' - 0" 55' - 0" 6' - 4 1 / 2 " 3' - 5 1 / 2 " 13 ' - 1 " 3' - 3 " 4' - 2 1 / 2 " 5' - 5 " 2 1 / 2 " 4' - 7" 1' - 5" 8' - 0" 30' - 0" 14' - 0" 5' - 2" 13' - 8 1/2" 11' - 1 1/2" 2' - 7" C D 36 ' - 0 " 9' - 1 0 " 16 ' - 4 " 9' - 1 0 " E 6 4 A-210 3 W2 W2 W1 W1 W1 W1 W3 W3 W3 W3 W2 W2 W3 W3 W/D BY OWNER, PROVIDE HOOKUPS AND INSTALL 1 EX1 EXISTING DOOR TO REMAIN, REVERSE DOOR SWING EXISTING OVERHEAD DOOR TO REMAIN 1 A-203 6' - 0" 2' - 0" 52' - 0" BATHROOM 1 109 RECOVERY ROOM 107 BATHROOM 2 106 RECEPTION 102 W1 W1 W1 W1 W1 W1 W1.1 W1.1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 W1 CEILING TRANSITION ABOVE EXISTING WALL FINISH TO REMAIN (TYP.) 1 A-301 1 A-301 3 4 1 RELOCATE EXISTING TRASH ENCLOSURE FLOOR TRANSITION (TYP.) A-211 12 9 REF ALL TRIM CONDITIONS TO MATCH EXISTING (TYP.) 11 10 LIMITS OF WORK NEW EXISTING NEW EXISTING 1 A-303 1 A-303 ROOF OVERHANG ABOVE 5 3 A-204 1' - 6 " 1' - 6 " EQ EQ 2 W3 W3 6 9' - 2 1 / 2 " 11 ' - 0 " FLEX SPACE 103 MECH. 104 OFFICE 105 NE W EX I S T I N G 2 6 6 FUR WALL AS NEEDED FOR W/D HOOKUPS LI M I T S O F W O R K LIMITS OF WORK EQ EQ 11 ' - 7 " 5 3 6 7' - 9 " BE N C H W / C U B B I E S COLD TUB, COORD. W/ OWNER AND MANUFACTURER W3 W3 W3 W3 W3 W3 W1 W1 EXISTING WALL FINISH TO REMAIN (TYP.) W1 W1 HOT TUB, COORD. W/ OWNER AND MANUFACTURER 7 - - - - - - ENTRY AWNING ABOVE A A 5 7 4 4 5 5 ALIGN DOOR W/ ENTRY DOOR 2 A-303 2 A-303 9' - 1" 4' - 11" C O O R D . W / S H O W E R I N S E R T 3 ' - 1 " SHOWER INSERT RAIN SHOWER HEAD SHOWER CURTAIN ROD 7 FIELD VERY EXISTING GRID LINES (TYP.) FIELD VERY EXISTING GRID LINES (TYP.) W2 W2 W1 W1 W3 W3 W2 W2 W1 W1 8 7 9 10 4 6 LAUNDRY 108 A B 8' - 11 1/2" TRAINING AREA 100 3 A-303 3 A-303 A-211 2 1 4 3 A-211 7 8 5 6 3 A-301 3 A-301 ALIGN WALL W/ MULLION OF WINDOW 4 ' - 0 " 6 ' - 4 " 4 ' - 0 " 1 A-205 WALK OFF CARPET FINISH FLOORING LEGEND COMMERCIAL CARPET TRAINING RUBBER FLOORING 1 TILE TRAINING RUBBER FLOORING 2 1 2 3 4 5 EXPOSED CONCRETE SLAB 6 *ALL FLOORING TO MATCH EXISTING WOOD COMPOSITE FLOORING 7 WALL TYPE LEGEND W1 EXTERIOR WALL -5/8" GWB., PAINT -BATT INSULATION, R-13 MIN. -2X6 WOOD STUDS, SSD -SHEATHING, SSD -AIR & WATER BARRIER -CONTINUOUS 1 1/2" RIGID INSULATION, R-7.5 MIN. -FINISH, SEE ELEVATIONS AND DETAILS W2 INTERIOR PARTITION WALL -5/8" GWB., PAINT -ACCOUSTIC INSULATION -2X6 WOOD STUDS, SSD -5/8" GWB., PAINT W3 INTERIOR PARTITION WALL -5/8" GWB., PAINT -ACCOUSTIC INSULATION -2X4 WOOD STUDS, SSD -5/8" GWB., PAINT W4 INTERIOR SHEATHED PARTITION WALL -5/8" GWB., PAINT -1/2" SHEATHING, SSD -ACCOUSTIC INSULATION -2X6 WOOD STUDS, SSD -1/2" SHEATHING, SSD -5/8" GWB., PAINT Date Drawn By Checked By: Project Number Sheet Name Copyright: ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF NE45 ARCHITECTURE Issued CONSTRUCTION DRAWINGS A-102 NEW ADDITION FLOOR PLAN TH E P I T T T R A I N I N G FA C I L I T Y - A D D I T I O N Checker Author 05-23-19 18017 37 1 7 E Q U E S T R I A N L N . BO Z E M A N , M T 5 9 7 1 8 1/4" = 1'-0" LEVEL 1 - ADDITION1 SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION GENERAL SHEET NOTES 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITONS IN THE FIELD PRIOR TO CONSTRUCTION AND ORDERING MATERIALS. 2. EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR FACE OF STUD FRAMING / OUTSIDE FACE OF FOUNDATION. 3. INTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE AND FACE OF STUD FRAMING. 4. REFER TO ARCHITECTURAL SHEET G-001 AND SHEET SERIES 200 EXTERIOR ELEVATIONS FOR THE IDENTIFICATION OF VARIOUS EXTERIOR WALL VENEER MATERIAL TYPES, LOCATIONS AND EXTENT. 5. REFER TO ARCHITECTURAL INTERIOR ELEVATION SHEET SERIES A-210 FOR CASEWORK AND COUNTERTOP CONFIGURATIONS AND HEIGHTS. 6. REFER TO REFLECTED CEILING PLANS FOR WALL OPENINGS AT OR ABOVE 4'-0" A.F.F. 7. ALL FFE ITEMS ARE OWNER PROVIDE. 10. PROVIDE ACOUSTICAL INSULATION IN SURROUNDING RESTROOM WALLS - TYPICAL 11. PROVIDE WOOD BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, CASEWORK AND ACCESSORIES. NO EXCEPTIONS 12. PROVIDE 3/4" PLYWOOD – COMMUNICATIONS / ELECTRICAL ROOM MOUNTING BOARD 13. ALL INTERIOR FRAMED WALL SYSEM ASSEBMPLIES TO BE TYPE P6a, P4 AND P4ww. 15. AT ALL CORRIDORS, LOBBIES, STAIRS AND COMMONS. ALL EXPOSED PARTITION ENDS, OUTSIDE CORNERS, AND TRIMMED OPENINGS SHALL HAVE CORNER GUARDS (GYPSUM BOARD WALLS ONLY.) 16. ALL CORRIDOR GYPSUM BOARD FACED WALLS SHALL BE 5/8" FIBER REINFORCED IMPACT RESISTANT GYPSUM BOARD TO 8'-0" A.F.F. 18. SPECIFICATIONS REQUIRE AN INTERNAL CORNER EXPANSION JOINT AT ALL LOCATIONS IN MASONRY VENEERS 20. ISOLATE PERIMETER OF NON-BEARING WALL BOARD PARTITIONS ON SLAB ON GRADE AT INTERSECTIONS WITH EXTERIOR WALL AND/OR BEARING WALLS - PROVIDE 1/4" SPACE VERTICAL SLIP JOINT TRIM EDES WITH L-TYPE EDGE TRIM AND SEAL WITH ACOUSTIC SEALANT 21 THE CONTRACT DOCUMENTS ARE COMPLEMENTARY: THE CONTRACTOR SHALL COORDINATE ALL PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. NOTIFY THE COR FOR RESOLUTION OF ALL DISCREPANCIES PROIR TO CONSTRUCTION. 22 LOCATE TYPICAL HINGE SIDE DOOR JAMB 4 - 4 1/2 INCHES FROM FINISH WALL TO EDGE OF DOOR OPENING. MAINTAIN A MINIMUM FINISHED CLEARANCE OF 18 INCHES TO THE STRIKE SIDE JAMB ON THE PULL SIDE OF ALL PUBLIC ACCESSIBLE DOORS. 23 LINE OF EXISTING GRADES, AS SHOWN ON THE BUILDING ELEVATIONS AND SECTIONS ARE APPROXIMATE. LINE OF EXISTING GRADES, AS SHOWN ON THE BUILDING ELEVATIONS AND 24 VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS CONTRACT, OR BY OTHERS. ALL EQUIPMENT TO BE SELECTED BY OWNER, CONTRACTOR AND CONSULTANTS. 25 REQUIRED FOR ACCESSORIES, MECHANICAL, ELECTRICAL AND OTHER FURRING, CURBS, ANCHORS AND INSERTS. PROVIDE ALL BASES AND BLOCKING REQUIRED OPENINGS THROUGH FLOORS AND WALLS, ACCESS DOORS, VERIFY SIZE/LOCATION/FINISH/FIRE-RATING, ETC. AND PROVIDE COMPLETE ALL REQUIRED OPENINGS THROUGH FLOORS AND WALLS, ACCESS DOORS, FURRING, CURBS, ANCHORS AND INSERTS. PROVIDE ALL BASES AND BLOCKING REQUIRED FOR ACCESSORIES, MECHANICAL, ELECTRICAL AND OTHER EQUIPMENT. 26 ALL EXTERIOR DRYVIT MUST FOLLOW MANUFACTURER INSTALLATION DETAILS AND SPECIFICATIONS. ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. COORDINATE WITH THE TEXTERIORS STORE WITH QUESTIONS. 27 ALL INTERIOR FLOORING MATERIAL FOR THE TRAINING FACILITY MUST FOLLOW THE MANUFACTURER INSTALLATION DETAILS AND SPECIFICATIONS. ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. COORDINATE WITH THE NEW ENGLAND TURF STORE WITH QUESTIONS. COLOR SELECTION BY OWNER 28 ALL ELECTRICAL OUTLET LOCATIONS ARE FOR REFERENCE ONLY. VERIFY LOCATIONS WITH AN ELECTRICAL ENGINEER CONSULTANT. 29 ALL STRUCTURAL ELEMENTS ARE FOR REFERENCE ONLY. REFER TO STRUCTURAL DRAWINGS. 31 REFER TO STRUCTURAL DRAWINGS FOR LOCATIONS OF SHEARWALL CONSTRUCTION WHERE PLYWOOD IS SUBSTITUTE FOR GYPSUM SHEATHING 32 PROVIDE MANUFACTURER STANDARD FLASHING DETAILS FOR ALL EXTERIOR DOORS AND STOREFRONT WINDOWS. 33 REFER TO SHEET SERIES A-600 FOR PROPOSED KAWNEER WINDOW AND DOOR INFORMATION. 35 ALL OUTLETS WITHIN 6' OF THE EDGE OF A SINK SHALL BE GFI PROTECTED PER NEC 210.8 (B) (5). PLAN NORTH 1 DESCRIPTION DATE BUILDING SQUARE FOOTAGE: EXISTING AREA: 5,108 SQ. FT. ADDITION AREA: 2,105 SQ. FT. MEZZANINE AREA: 306 SQ. FT. TOTAL FINISHED AREA: 7,519 SQ. FT .