HomeMy WebLinkAboutA-101 NEW OVERALL FLOOR PLAN 05-23-19UP
4
A-201
1
A-201 3
A-201
1 1
2 2
4 4
3 3
B
B
C
C
E
E
F
F
6' - 0" 38' - 0" 6' - 0" 2' - 0"
AS-101
2
2
A-302
2
A-302
A-102
1
10' - 2" 13' - 4"
36' - 11"
1
A-202
2
A-202
2
A-203
RECOVERY
ROOM
107
BATHROOM 2
106
BATHROOM 1
109
EXISTING BUILDING
1
A-302
1
A-302
D
D
1
A-203
9'
-
1
0
"
16
'
-
4
"
9'
-
1
0
"
NEW
EXISTING
NEW
EXISTING
1
A-303
1
A-303
36
'
-
0
"
ROOF OVERHANG ABOVE
1
1
A-204
3
A-204
2
A-204
52' - 0"
70
'
-
6
1
/
2
"
9'
-
1
0
"
16
'
-
4
"
9'
-
1
0
"
34
'
-
6
1
/
2
"
C D E
RELOCATE EXISTING
TRASH ENCLOSURE
6
8' - 0"
6' - 0" 2' - 0"
6' - 0" 38' - 0"
FLEX SPACE
103
MECH.
104
OFFICE
105
3
4
2
6
5
-
-
-
-
-
-
-
-
E-101
1
A
A
5 5
2
A-303
2
A-303
3
A-303
3
A-303
1
A-205
Date
Drawn By
Checked By:
Project Number
Sheet Name
Copyright:
ALL DRAWN AND WRITTEN INFORMATION
APPEARING SHALL NOT BE DUPLICATED,
DISCLOSED OR OTHERWISE USED
WITHOUT THE WRITTEN CONSENT OF
NE45 ARCHITECTURE
Issued
CONSTRUCTION DRAWINGS
A-101
NEW OVERALL
FLOOR PLAN
TH
E
P
I
T
T
T
R
A
I
N
I
N
G
FA
C
I
L
I
T
Y
-
A
D
D
I
T
I
O
N
RN & BE
NE45
05-23-19
18017
37
1
7
E
Q
U
E
S
T
R
I
A
N
L
N
.
BO
Z
E
M
A
N
,
M
T
5
9
7
1
8
1/8" = 1'-0"
FLOOR PLAN1
SHEET SPECIFIC GENERAL INFORMATION AND/OR INSTRUCTION
GENERAL SHEET NOTES
1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITONS IN THE FIELD PRIOR TO
CONSTRUCTION AND ORDERING MATERIALS.
2. EXTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR FACE OF STUD FRAMING
/ OUTSIDE FACE OF FOUNDATION.
3. INTERIOR BUILDING DIMENSIONS ARE TO GRID CENTERLINE AND FACE OF STUD FRAMING.
4. REFER TO ARCHITECTURAL SHEET G-001 AND SHEET SERIES 200 EXTERIOR ELEVATIONS FOR
THE IDENTIFICATION OF VARIOUS EXTERIOR WALL VENEER MATERIAL TYPES, LOCATIONS AND
EXTENT.
5. REFER TO ARCHITECTURAL INTERIOR ELEVATION SHEET SERIES A-210 FOR CASEWORK AND
COUNTERTOP CONFIGURATIONS AND HEIGHTS.
6. REFER TO REFLECTED CEILING PLANS FOR WALL OPENINGS AT OR ABOVE 4'-0" A.F.F.
7. ALL FFE ITEMS ARE OWNER PROVIDE.
10. PROVIDE ACOUSTICAL INSULATION IN SURROUNDING RESTROOM WALLS - TYPICAL
11. PROVIDE WOOD BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, CASEWORK AND
ACCESSORIES. NO EXCEPTIONS
12. PROVIDE 3/4" PLYWOOD – COMMUNICATIONS / ELECTRICAL ROOM MOUNTING BOARD
13. ALL INTERIOR FRAMED WALL SYSEM ASSEBMPLIES TO BE TYPE P6a, P4 AND P4ww.
15. AT ALL CORRIDORS, LOBBIES, STAIRS AND COMMONS. ALL EXPOSED PARTITION ENDS, OUTSIDE
CORNERS, AND TRIMMED OPENINGS SHALL HAVE CORNER GUARDS (GYPSUM BOARD WALLS
ONLY.)
16. ALL CORRIDOR GYPSUM BOARD FACED WALLS SHALL BE 5/8" FIBER REINFORCED IMPACT
RESISTANT GYPSUM BOARD TO 8'-0" A.F.F.
18. SPECIFICATIONS REQUIRE AN INTERNAL CORNER EXPANSION JOINT AT ALL LOCATIONS IN
MASONRY VENEERS
20. ISOLATE PERIMETER OF NON-BEARING WALL BOARD PARTITIONS ON SLAB ON GRADE AT
INTERSECTIONS WITH EXTERIOR WALL AND/OR BEARING WALLS - PROVIDE 1/4" SPACE VERTICAL
SLIP JOINT TRIM EDES WITH L-TYPE EDGE TRIM AND SEAL WITH ACOUSTIC SEALANT
21 THE CONTRACT DOCUMENTS ARE COMPLEMENTARY: THE CONTRACTOR SHALL COORDINATE ALL
PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS. NOTIFY THE COR FOR
RESOLUTION OF ALL DISCREPANCIES PROIR TO CONSTRUCTION.
22 LOCATE TYPICAL HINGE SIDE DOOR JAMB 4 - 4 1/2 INCHES FROM FINISH WALL TO EDGE OF DOOR
OPENING. MAINTAIN A MINIMUM FINISHED CLEARANCE OF 18 INCHES TO THE STRIKE SIDE JAMB
ON THE PULL SIDE OF ALL PUBLIC ACCESSIBLE DOORS.
23 LINE OF EXISTING GRADES, AS SHOWN ON THE BUILDING ELEVATIONS AND SECTIONS ARE
APPROXIMATE.
LINE OF EXISTING GRADES, AS SHOWN ON THE BUILDING ELEVATIONS AND
24 VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT PROVIDED IN THIS CONTRACT, OR BY
OTHERS. ALL EQUIPMENT TO BE SELECTED BY OWNER, CONTRACTOR AND CONSULTANTS.
25 REQUIRED FOR ACCESSORIES, MECHANICAL, ELECTRICAL AND OTHER FURRING, CURBS,
ANCHORS AND INSERTS. PROVIDE ALL BASES AND BLOCKING REQUIRED OPENINGS THROUGH
FLOORS AND WALLS, ACCESS DOORS, VERIFY SIZE/LOCATION/FINISH/FIRE-RATING, ETC. AND
PROVIDE COMPLETE ALL REQUIRED OPENINGS THROUGH FLOORS AND WALLS, ACCESS DOORS,
FURRING, CURBS, ANCHORS AND INSERTS. PROVIDE ALL BASES AND BLOCKING REQUIRED FOR
ACCESSORIES, MECHANICAL, ELECTRICAL AND OTHER EQUIPMENT.
26 ALL EXTERIOR DRYVIT MUST FOLLOW MANUFACTURER INSTALLATION DETAILS AND
SPECIFICATIONS. ARCHITECTURAL DRAWINGS ARE FOR REFERENCE ONLY. COORDINATE WITH
THE TEXTERIORS STORE WITH QUESTIONS.
27 ALL INTERIOR FLOORING MATERIAL FOR THE TRAINING FACILITY MUST FOLLOW THE
MANUFACTURER INSTALLATION DETAILS AND SPECIFICATIONS. ARCHITECTURAL DRAWINGS ARE
FOR REFERENCE ONLY. COORDINATE WITH THE NEW ENGLAND TURF STORE WITH QUESTIONS.
COLOR SELECTION BY OWNER
28 ALL ELECTRICAL OUTLET LOCATIONS ARE FOR REFERENCE ONLY. VERIFY LOCATIONS WITH AN
ELECTRICAL ENGINEER CONSULTANT.
29 ALL STRUCTURAL ELEMENTS ARE FOR REFERENCE ONLY. REFER TO STRUCTURAL DRAWINGS.
31 REFER TO STRUCTURAL DRAWINGS FOR LOCATIONS OF SHEARWALL CONSTRUCTION WHERE
PLYWOOD IS SUBSTITUTE FOR GYPSUM SHEATHING
32 PROVIDE MANUFACTURER STANDARD FLASHING DETAILS FOR ALL EXTERIOR DOORS AND
STOREFRONT WINDOWS.
33 REFER TO SHEET SERIES A-600 FOR PROPOSED KAWNEER WINDOW AND DOOR INFORMATION.
35 ALL OUTLETS WITHIN 6' OF THE EDGE OF A SINK SHALL BE GFI PROTECTED PER NEC 210.8 (B) (5).
PLAN NORTH
1 DESCRIPTION DATE
BUILDING SQUARE FOOTAGE:
EXISTING AREA: 5,108 SQ. FT.
ADDITION AREA: 2,105 SQ. FT.
MEZZANINE AREA: 306 SQ. FT.
TOTAL FINISHED AREA: 7,519 SQ. FT .