Loading...
HomeMy WebLinkAbout2019 Stormwater Improvements - Record Drawings KELLEN M. O GAMRADT G BOZEMAN STORMWATER IMPROVEMENTS P��t�EL, ��QVAL b� mum ti CITY OF BOZEMAN MONTANA � _ um ....... ...... .......... 2019 a a � 1883 LEGEND R N CO. GENERAL NOTES z GASEXISTING GAS LINE 0 o q 1. ALL WORK ON THIS PROJECT SHALL BE DONE IN ACCORDANCE WITH THE W m MONTANA PUBLIC WORKS STANDARD SPECIFICATIONS, 6TH EDITION, AND THE CITY N i oa OF BOZEMAN MODIFICATIONS TO THE MONTANA PUBLIC WORKS STANDARD EXISTING STORM DRAIN SPECIFICATIONS, 6TH EDITION, INCLUDING ADDENDUMS, THESE PLANS, AND THE n 2 CONTRACT DOCUMENTS. A a< 1 INDEX pi EXISTING WATER MAIN O I e 2. THE LOCATION OF EXISTING UTILITIES SHOWN SHOULD BE CONSIDERED o APPROXIMATE AND THE CONTRACTOR SHALL FIELD VERIFY UTILITIES PRIOR TO CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR UTILITY LOCATES PRIOR E TO AND DURING CONSTRUCTION. THE CONTRACTOR SHALL TAKE ALL MEANS EXISTING WATER SERVICE cs NECESSARY TO PROTECT EXISTING UTILITIES. o o W Nm COVER SHEET 1 3. TYPE 1 PIPE BEDDING SHALL BE USED FOR ALL NEW STORM PIPE. T EXISTING TELEPHONE LINE 4. THE STORM DRAIN LINES SHOWN ON THE PLANS ARE LOCATED E NORTH BLACK TREATMENT UNIT (A) 2 APPROXIMATELY. THE CONTRACTOR SHALL VERIFY THE LOCATIONS AND DEPTH a OF THESE LINES, WHICH VARY IN SIZE AND COMPOSITION. 01 °HP EXISTING OVERHEAD POWER Li • PxP NORTH BOZEMAN TREATMENT UNIT (B) 3 ,11��oy 5. WHERE CONDITIONS ARE ENCOUNTERED WHICH DEVIATE FROM THOSE �v $ DETAILS SHEET 4 INDICATED ON THE PLANS OR IN THE SPECIFICATIONS, THE CONTRACTOR SHALL U w NOTIFY THE PROJECT ENGINEER OR HIS REPRESENTATIVE PRIOR TO MAKING ANY EXISTING UNDERGROUND POWER CHANGES IN THE WORK. 1t�« G►yd~ 6. THE CONTRACTOR IS RESPONSIBLE FOR ALL JOBSITE SAFETY FOR HIS EXISTING SEWER MAIN WORKERS AND THE PUBLIC. ADEQUATE SANITATION FACILITIES SHALL BE PROVIDED BY THE CONTRACTOR FOR HIS PERSONNEL. Z PROPOSED WORK 7. THE CONTRACTOR SHALL PROTECT ADJACENT PUBLIC AND PRIVATE PROPERTY EXISTING SEWER SERVICE W VICINITY MAP AREAS FROM DAMAGE OWN EXPENSE.DURING CONSTRUCTION AND SHALL REPAIR ANY DAMAGE AT HIS w EXISTING CATCH BASIN O > Fridle L St Q 8. EXISTING PIPE THAT IS ABANDONED IN PLACE SHALL BE CAPPED OR O d _ O of Q PLUGGED WITH CONCRETE AT ALL OPENINGS. Villa St. 9. THE CONTRACTOR SHALL ADJUST ALL MANHOLES TO FINAL GRADE UPON ® EXISTING CURB STOP a Z U Z L COMPLETION OF ALL CONSTRUCTION. ANY MANHOLES DAMAGED OR OTHERWISE �� � Davls [St. DISTURBED BY THE CONTRACTOR OR ANY SUBCONTRACTOR SHALL BE REPAIRED Z a- AT THE EXPENSE OF THE CONTRACTOR. v P4 � � ❑ 0 U � EXISTING WATER GATE VALVE W e F r+) FB]eI St. 10. THE CONTRACTOR IS RESPONSIBLE FOR CONTROLLING DUST AND EROSION E-� W Y L e St. DURING CONSTRUCTION AT HIS EXPENSE. STREETS SHALL BE WATERED TO Q' o x z U U CONTROL DUST WHEN ORDERED BY THE ENGINEER. EROSION AND STORM WATER EXISTING FIRE HYDRANT V1 � m POLLUTION SHALL BE CONTROLLED IN ACCORDANCE WITH THE APPROVED STORM W ❑ WATER POLLUTION PREVENTION PLAN. EnEn D[E] 1 2 z z 11. THE CONTRACTOR SHALL MAINTAIN SERVICE OF ALL EXISTING UTILITIES. IF EXISTING STREET LAMP O c O SAID SERVICE IS DAMAGED, THE CONTRACTOR SHALL IMMEDIATELY REPAIR THE w U r _ ❑❑❑ DAMAGE AT CONTRACTORS EXPENSE. O EXISTING SEWER MANHOLE z ❑ 12. WHERE NEW PAVEMENT IS ADJACENT TO EXISTING PAVEMENT, SAWCUT 12- Fn n Q ai MINIMUM (OR AS DIRECTED BY ENGINEER) FROM THE EXISTING EDGE TO PROVIDE A BUTT JOINT. TACK THE SAWCUT EDGE WITH CSS OR SS-1 H EMULSIFIED El 1:1 Babcock St. Q ASPHALT PRIOR TO PLACING THE ADJACENT NEW PAVEMENT. EXISTING STREET SIGN N a O 13. ACCESS FOR OTHER CONTRACTORS WORKING ON THE SITE AND EMERGENCY Elr 0 ❑ VEHICLES SHALL BE PRESERVED AT ALL TIMES IN ACCORDANCE WITH THE — RIGHT OF WAY IVe S Olive St. o SPECIAL PROVISIONS IN THE PROJECT MANUAL. 14. A TRAFFIC CONTROL PLAN MUST BE APPROVED BY THE CITY ENGINEER C ❑❑ m PRIOR TO ANY STREET CLOSURE. PROPOSED STORM DRAIN FCurtQ N > N CUrtISS St. 15. CONTRACTOR MUST PROTECT ALL EXCAVATIONS LEFT OVERNIGHT PER MUTCD ]<'>u Q ❑ Q p C> INCLUDING CONTINUOUS FENCING. PROPOSED CATCH CURB sHT No. 10 KocSt. FI FG FINISH GRADE SPOT ELEVATION OF 4 J I y�umnu � Q CONTROL POINT#101 � w p I N=120237.75 KELLEN M. �_ E=382904.15 GAMRADT Ul ELEV=4811.92 No.40758PE (N CENS�O - _ CENS AL. nnnm I "A. 0xswx er: �c j`� S SD Scole: 1"=40' nerc oe-orte 0 10 20 40 .a• z � o go RECONNECT TO EXISTING p" 10"CLAY STORM PIPE o W/FERNCO CLAY TO PVC CPLG STA 0+50 OR APPROVED EQUAL INSTALL 6'DIA.SEPARATOR UNIT A CONNECT TO SEPARATOR UNIT W/ RIM ELEV.=4809.22 12"SDR-35 PVC PIPE z' 12"SDR-35 PVC INV.IN(S)=4804.19 _ PROPOSED LIMITS 12"SDR-35 PVC INV.OUT(N)=4804.13 N OF DISTURBANCE SEE DETAIL SHEET"4" � N W EF N \ . LLI m SAWCUT&REMOVE EXISTING N z -. SIDEWALK,CURB,GUTTER&ASPHALT / b iC g;' AS REQUIRED Q 0. n es Y 00.< U o (3 ; m �poo y 71 N Z E.MAIN ST. coo (NEXT CROSS STREET SOUTH) N w E- 'm a HORIZ. SCALE: 1" = 40' VERT. SCALE: 1" = 8' 0 8 FLOWABLE BACKFILL PER CONTRACT SPECIFICATIONS STA 0+50 INSTALL SEPARATOR UNIT "A" RECONNECT TO STORM MAIN UPSTREAM & DOWNSTREAM �"tjQ« c►~� E- 4820 4820 Z W INSTALLATION NOTES. W 1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE LIMITS OF 4816 4816 p EXCAVATION REQUIRED TO COMPLETE THE WORK. LIMITS OF DISTURBANCE MAY STAG+50 P4 x VARY DEPENDING ON THE EQUIPMENT USED AND THE STABILITY OF THE TRENCH INSTALL 6'DIA.SEPARATOR UNIT A (- RIM ELEV.=4809.22 AT THE TIME OF EXCAVATION. RESTORATION OF THE WORK AREA SHALL BE A 12"SDR-35 PVC INV.IN(S)=4804.19 --1 LUMP SUM BID. THE CONTRACTOR WILL BE COMPENSATED FOR THIS WORK AT THE 4812 EXISTING GRADE 12"SDR-35 PVC INV.OUT(N)=4804.13 4812 x LUMP SUM BID PRICE REGARDLESS OF QUANTITY. SEE DETAIL SHEET"a" a E- 2. SAWCUT EXISTING 10"STORM PIPE AS NEEDED TO INSTALL SEPARATOR UNIT AND W 0 TRANSITION TO 12"SDR-35 PVC PIPE AT SEPARATOR CONNECTIONS. TRANSITION z COUPLERS SHALL BE FERNCO CLAY TO PVC COUPLINGS OR APPROVED EQUAL. 4808 4808 3. BACKFILL EXCAVATION TO BOTTOM OF ASPHALT GRADE/WITH NON-SHRINK FLOWABLE FILL. 4. RESTORE WORK AREA TO PRE-EXISTING CONDITIONS. _ _— O N E• 5. WORK WITH FIELD ENGINEER TO ROTATE SEPARATOR CASTING TO AVOID EXISTING 4804 _ 4804 z CURB FLOW LINE. � EXISTING 10"VCP z REMOVE&REPLACE W/12"SDR-35 PVC ' E--'i 4800 AS REQUIRED 4800 W N � O w GG � 4796 4796 QJ 4794 4794cl p O ccq (00 V N 41 h to ci O O 0) m O O) OD W N O 00 O O O O O O O O O O ro 00 co m m m m OD 00 a0 SHEET No. 2 7 V V V V V -It V V V 0+00 0+20 0+40 0-F60 0+80 1+00 1+15 2 OF 4 \ / � I �n111Nllllllll CONTROL POINT 17102 I////////`jl N=120219.82 Y = KELLE M. E=383184.23 ELEV=4810.26 0 I �� GAMRADT N0.07758 E CENS AI, � nnnm DRAWN BY: RIM FO —� CHIN BY: APPROVED BY. SD 1+07 SE LLE Beta oa7oAna - _ - - - RECONNECT TO EXISTING a - I = 12"CLAY STORM PIPE -� ; - - PROPOSED LIMITS ;> W/CLAY TO PVC FERNCO CPLG Y _I OF DISTRUBANCE OR APPROVED EQUAL to C Alt. STA 0+50 zo .y INSTALL 6'DIA.SEPARATOR UNIT B a RIM ELEV.=4810.30 - 9- ___ _ _ - - - 12"SDR-35 PVC INV.MIS)=4805.78 0 _ 12"SDR-35 PVC INV.OUT(N)=4805.75 "4 SEE DETAIL SHEET 4 - _ Scale: 1'=40' z° _ 0 10 20 40 m - RECONNECT TO EXISTING iu 12"CLAY STORM PIPE jn W/CLAY TO PVC FERNCO CPLG �' m m 37 is OR APPROVED EQUAL Q W wmm Z C> �� D�' a m R • • IN R�poo (n ✓✓- E.MAIN ST. o 0 0 m (NEXT CROSS STREET SOUTH) E- 'm a • r HORIZ. SCALE: 1" = 40' VERT. SCALE: 1" = 8' Q� 'll N O 8 FLOWABLE BACKFILL PER CONTRACT SPECIFICATIONS STA 0+50 INSTALL SEPARATOR UNIT "B" RECONNECT TO.STORM MAIN UPSTREAM & DOWNSTREAM. �ffJ« Ostia 4820 4820 E- E- z w INSTALLATION NOTES: 4816 4816 1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE LIMITS OF INSTALL 6'DIA.SEPARATOR UNIT B RIM ELEV.=4810.30 O EXCAVATION REQUIRED TO COMPLETE THE WORK. LIMITS OF DISTURBANCE MAY 12"SDR-35 PVC INV.IN(S)=4805.78 (]� VARY DEPENDING ON THE EQUIPMENT USED AND THE STABILITY OF THE TRENCH 12"SDR-35 PVC INV.OUT(N)=4805.75 a W AT THE TIME OF EXCAVATION. RESTORATION OF THE WORK AREA SHALL BE A LUMP SEE DETAIL SHEET 4812 EXISTING GRADE 4812 N SUM BID. THE CONTRACTOR WILL BE COMPENSATED FOR THIS WORK AT THE LUMP m SUM BID PRICE REGARDLESS OF QUANTITY. 2. SAWCUT EXISTING 12"CLAY STORM PIPE AS NEEDED TO INSTALL SEPARATOR UNIT W e E- AND TRANSITION TO 12"SDR-35 PVC PIPE AT SEPARATOR CONNECTIONS. 4808 4808 E- 0 TRANSITION COUPLERS SHALL BE FERNCO CLAY TO PVC COUPLINGS OR APPROVED — Z EQUAL. 3. BACKFILL EXCAVATION TO BOTTOM OF ASPHALT GRADE/WITH NON-SHRINK _ _ I FLOWABLE FILL. 4804 FERNCO 4804 N 4. RESTORE WORK AREA TO PRE-EXISTING CONDITIONS. TRANSITIONS o �E- 5. WORK WITH FIELD ENGINEER TO ROTATE SEPARATOR CASTING TO AVOID EXISTING EXISTING 12"VCP CURB FLAW LINE. - REMOVE&REPLACE Iz W/12"SDR-35 PVC o 7- 4800 As REQUIRED 4800 �d'1 P4 0 w -ell N W4 o a 4796 4796 (� W o rn � m � M `O rn 00 l": � v Q� O O CJ O O O aS of of rn .--1 0 0 0 0 v v v v v v v v v v v � 0+00 0+20 0+40 0+60 0+80 1+00+07 SHEET No. 8 3 OF 4 �NNIIIN1111111 N 180' 180' KELLLE M..- GAMRADT No.40758PE FIBERGLASS SEPARATION TOP SLAB FIBERGLASS SEPARATION _ TOP SLAB �CENS�� CYLINDER&INLET 30"ACCESS CYLINDER&INLET 30"ACCESS Si,AL PENETRATION PENETRATION nNMI. DRAWN BY: HYC CB6CYBD BY: i APPROVED BY: 12"INSET 11 12"OUTLET_ 12"INLET_ 12"OUTLET_ DAta: D7oIza a z - _ o � ; a 0 CONTECH CDS3035-6-C CONTECH CDS3035-6-C z° m = z N RIM=4810.30 w RIM 4809.22 vl N ty m EF.O EXISTING 10" I w 0 0�' CLAY PIPE � 2.5' ". .' - 2.5' 0.0 O R P7 0.d I FIBERGLASS SEPARATION FIBERGLASS SEPARATION I CYLINDER&INLET CYLINDER&INLET 0 I m 12"SDR-35 12"SDR-35 12"SDR-35 12"SDR-35 yy N PVC INLET - 3.83, PPVC OUTLET 10"CLAY TO PVC IN I PVC OUTLET E-I o m 3.83 PIPE NH o In PIPE PVC FERNCO PIPE yl -- __ CPLG O 0 mo f 1 N Rl v L A INV.=4804.19 INV.=4804.13 _ INV. 05.78 _ - IN 805.75 E- T 12"xt0" EXISTING t3 « ►N� 12"VPC PIPE ECCENTRIC EXISTING 12"x10" - 12"VPC PIPE Qi II ECCENTRIC PVC REDUCER CLAY r0 PVC HYDRODYNAMIC SEPARATOR UNIT SPECIFICATIONS: N FERNCO c 8 PVC REDUCER 4.09' EXISTING 10" (TYP. OF 2) 4.09, 10"CLAY TO CLAY PIPE 1. RATED TREATMENT CAPACITY=3.8 CFS PVC FERNCO 6.75' OIL BAFFLE SKIRT 6 75' 2. MAXIMUM INTERNAL BYPASS CAPACITY=20.0 CFS dff�« c►'''' CPLG 3. SITE SPECIFIC MAXIMUM FLOW: 3.1. UNIT A=10.51 CFS U1 3.2. UNIT B=10.51 CFS E- r 2 , 2 001 4. INSTALL PER MANUFACTURERS RECOMMENDATIONS W 5. SUMP SEDIMENT STORAGE CAPACITY=2.1 CY 6. MINIMUM OIL STORAGE CAPACITY=263 GALLONS W 7. PRE-APPROVED UNIT IS CONTECH CDS 3035-6-C a 7.1. PRODUCT SUBSTITUTIONS SHALL BE EVALUATED 0 ON AN INDIVIDUAL BASIS a [- r � A H-I 6.0' 6.0' W e h H � � a w 04 SEPARATOR UNIT A SEPARATOR UNIT B o z o W yA.l N x 0 as rn 0 SHEET No. 4 4 OF 4