HomeMy WebLinkAboutFlanders Mill Subdivision Phase 7PH-7WW WWWWW W PH-6PH-6PH-5PH-4 W WW W PH-7WWWPH. 4 PH-6WW PH-6W PH-6 PH-6 W WW W W WW W PH-7 PH-6WW PH-6W PH-6 W PH-6 PH-6 WPH-4 W W W LocationPedestrianConflictSpacing (ft)MountHeight (ft) Light TypeWattsPole Base CoverTypeMountingArmVoltageLocal StreetsLow Intersections 25 ELA BELL22-CR21A-P3048K-MOD25 75 ELA P-3048 ELA CR21A 240Harvest ParkwayMediansLow Intersections 25(2) ELA BELL22-CR21B-P3048K-MOD252@35ELA P-3048ELA CR21B240Oak StreetCorridor LightingMedStaggered200-250 35 PHILIPS LUMEC RFL 215W96LEDK-T 207KWRTSE35-8.0-11-KZ91KWRTSE-110PS UNIVTrail CrossingsCrossingsN/ARAB BLED20Y22N/AN/AUNIV A A X XX X X X X X XXXXXXXX X X XXX Upland Seed Mix%Durar hard Fescue29%Turf-Type Tall Fescue14%Canada Bluegrass14%Sheep Fescue29%Spring Triticale8%Winter Annual Grain (Wheat, Rye, Oat, etc.)8%Wetland Seed Mix%Tufted Hairgrass32%'Sodar' Streambank Wheatgrass27%Slender Wheatgrass28%Fowl Mannagrass3%Fowl Bluegrass2%Winter Annual Grain (Wheat, Rye, Oat, etc.)8% CHANNELINSTALLATIONDETAILDrawing Not To Scale1.Prepare soil before installing rollederosion control products (RECPs),including any necessary application oflime, fertilizer, and seed.2.Begin at the top of the channel byanchoring the RECPs in a 6"(15cm)deep X 6"(15cm) wide trench withapproximately 12"(30cm) of RECPsextended beyond the up-slope portionof the trench. Use ShoreMax mat at thechannel/culvert outlet as supplementalscour protection as needed. Anchor theRECPs with a row of staples/stakesapproximately 12"(30cm) apart in thebottom of the trench. Backfill andcompact the trench after stapling. Applyseed to the compacted soil and fold theremaining 12"(30cm) portion of RECPsback over the seed and compacted soil.Secure RECPs over compacted soilwith a row of staples/stakes spacedapproximately 12" apart across thewidth of the RECPs.3. Roll center RECPs in direction of waterflow in bottom of channel. RECPs willunroll with appropriate side against thesoil surface. All RECPs must besecurely fastened to soil surface byplacing staples/stakes in appropriatelocations as shown in the staple patternguide.4.Place consecutive RECPs end-over-end(Shingle style) with a 4"-6" overlap. Usea double row of staples staggered 4"apart and 4" on center to secureRECPs.5.Full length edge of RECPs at top of sideslopes must be anchored with a row ofstaples/stakes approximately 12"(30cm)apart in a 6"(15cm) deep X 6"(15cm)wide trench. Backfill and compact thetrench after stapling.6. Adjacent RECPs must be overlappedapproximately 2"-5" (5-12.5cm)(Depending on RECPs type) andstapled.7.In high flow channel applications astaple check slot is recommended at 30to 40 foot (9 -12m) intervals. Use adouble row of staples staggered4"(10cm) apart and 4"(10cm) on centerover entire width of the channel.8. The terminal end of the RECPs must beanchored with a row of staples/stakesapproximately 12" (30cm) apart in a6"(15cm) deep X 6"(15cm) wide trench.Backfill and compact the trench afterstapling.Drawn on: 5-4-172"-5"(5-12.5cm)62412"(30cm)6"(15cm)6"(15cm)4"-6"(10-15cm)86"(15cm)574"(10cm)31ABCABC NOTES:*Horizontal staple spacing should bealtered if necessary to allow staples tosecure the critical points along the channelsurface.**In loose soil conditions, the use of stapleor stake lengths greater than 6"(15cm) maybe necessary to properly secure theRECP's. CRITICAL POINTSA. Overlaps and SeamsB. Projected Water LineC. Channel Bottom/Side Slope Vertices4"(10cm)6"(15cm)5401 St. Wendel - Cynthiana Rd.Poseyville, IN 47633PH: 800-722-2040www.nagreen.comEROSION CONTROL MATTING TO BE BIONETSC150BN AMERICAN GREEN OR APPROVED EQUAL