HomeMy WebLinkAboutG1.2 General Notes 12-26-2018PR
O
J
E
C
T
D
E
S
C
R
I
P
T
I
O
N
1.
D
E
S
I
G
N
A
N
D
C
O
N
S
T
R
U
C
T
I
O
N
O
F
A
3
S
T
O
R
Y
O
F
F
I
C
E
B
U
I
L
D
I
N
G
WI
T
H
A
B
A
S
E
M
E
N
T
.
M
E
T
A
L
F
R
A
M
E
S
T
R
U
C
T
U
R
E
W
I
T
H
F
R
A
M
I
N
G
AN
D
C
O
N
C
R
E
T
E
F
O
U
N
D
A
T
I
O
N
.
AP
P
L
I
C
A
B
L
E
C
O
D
E
S
20
1
2
I
N
T
E
R
N
A
T
I
O
N
A
L
E
N
E
R
G
Y
C
O
N
S
E
R
V
A
T
I
O
N
C
O
D
E
20
1
2
I
N
T
E
R
N
A
T
I
O
N
A
L
B
U
I
L
D
I
N
G
C
O
D
E
20
1
2
I
N
T
E
R
N
A
T
I
O
N
A
L
F
U
E
L
G
A
S
C
O
D
E
20
1
4
N
A
T
I
O
N
A
L
E
L
E
C
T
R
I
C
A
L
C
O
D
E
20
1
2
U
N
I
F
O
R
M
P
L
U
M
B
I
N
G
C
O
D
E
20
1
2
I
N
T
E
R
N
A
T
I
O
N
A
L
M
E
C
H
A
N
I
C
A
L
C
O
D
E
AN
S
I
A
1
1
7
.
1
-
2
0
0
3
PR
O
J
E
C
T
I
N
F
O
&
C
O
D
E
A
N
A
L
Y
S
I
S
:
ZO
N
I
N
G
S
U
M
M
A
R
Y
ZO
N
I
N
G
:
B
2
-
B
O
Z
E
M
A
N
G
A
T
E
W
A
Y
P
U
D
*A
L
L
O
W
A
B
L
E
B
L
D
G
.
H
E
I
G
H
T
:
6
5
F
E
E
T
BU
I
L
D
I
N
G
L
O
T
A
R
E
A
:
1
9
,
4
8
9
S
F
,
0
.
4
5
A
C
R
E
S
LE
G
A
L
L
O
T
A
R
E
A
A
L
L
O
W
E
D
:
FU
L
L
C
O
V
E
R
A
G
E
O
F
B
L
O
C
K
EX
C
E
P
T
F
O
R
Y
A
R
D
S
E
T
B
A
C
K
S
YA
R
D
S
E
T
B
A
C
K
S
:
FR
O
N
T
Y
A
R
D
:
1
5
F
T
.
SI
D
E
Y
A
R
D
:
1
0
F
T
.
BA
C
K
Y
A
R
D
:
1
0
F
T
.
US
E
A
N
D
O
C
C
U
P
A
N
C
Y
:
BUILDING HEIGHT AND AREA:TYPE OF CONSTRUCTION:
OC
C
U
P
A
N
C
Y
G
R
O
U
P
S
:
A-
2
IN
C
I
D
E
N
T
A
L
U
S
E
S
:
*A
L
L
I
N
C
I
D
E
N
T
A
L
U
S
E
A
R
E
A
S
P
R
O
V
I
D
E
D
W
I
T
H
A
U
T
O
M
A
T
I
C
F
I
R
E
-
EX
T
I
N
G
U
I
S
H
I
N
G
S
Y
S
T
E
M
S
-
R
O
O
M
S
w
/
B
0
I
L
E
R
S
O
V
E
R
1
5
P
S
I
A
N
D
1
0
H
O
R
S
E
P
O
W
E
R
(
S
M
O
K
E
PA
R
T
I
T
I
O
N
)
-
S
T
O
R
A
G
E
R
O
O
M
>
1
0
0
S
F
.
(
S
M
O
K
E
P
A
R
T
I
T
I
O
N
)
-
W
A
S
T
E
C
O
L
L
E
C
T
I
O
N
R
O
O
M
>
1
0
0
S
F
.
(
S
M
O
K
E
P
A
R
T
I
T
I
O
N
)
OC
C
U
P
A
N
C
Y
S
E
P
A
R
A
T
I
O
N
S
T
A
B
L
E
5
0
8
.
4
SE
P
A
R
A
T
E
D
B
U
I
L
D
I
N
G
O
C
C
U
P
A
N
C
I
E
S
T
O
C
O
N
F
O
R
M
W
I
T
H
S
E
C
T
I
O
N
50
8
.
4
O
C
C
U
P
A
N
C
Y
S
E
P
A
R
A
T
I
O
N
A
R
E
R
E
Q
U
I
R
E
D
-
M
A
X
.
A
R
E
A
P
E
R
M
O
S
T
R
E
S
T
R
I
C
T
I
V
E
U
S
E
OC
C
U
P
A
N
C
Y
L
O
A
D
S
(
T
A
B
L
E
1
0
0
4
.
1
.
2
)
SE
E
A
R
E
A
S
C
H
E
D
U
L
E
ALLOWABLE HEIGHTS / AREAS TABLE 503 TYPE III-B CONSTRUCTION GROUP A-2: 9,500/FLOOR, 2 STORIES (3 STORIES FOR SPRINK.)ALLOWABLE AREA: 9,500/FLR + 19,000/FLR (INCREASE AREA FOR SPRINKLERS) + 2,565/FLR (FRONTAGE) = 31,065/FLOOR ALLOWABLE HEIGHT: 55'-0" + 20'-0"(INCREASE HT. FOR SPRINK.) = 65'-0"ACTUAL HEIGHT: 53'-6", 3 STORIES ACTUAL AREA: 11,260 SF - MAIN FLOOR ACTUAL BUILDING AREAS:MAIN LEVEL: 11,260 SF SECOND LEVEL: 12,263 SF THIRD LEVEL: 5,004 SF TYPE III-B - FULLY SPRINKLED-NFPA 13 (903.3.1.1)FIRE RESISTIVE REQUIREMENTS (TABLE 601 AND 602)STRUCTURAL FRAME: 0 HR EXTERIOR BEARING WALL: 2 HR INTERIOR BEARING WALL: 0 HR INTERIOR NON-BEARING WALLS: 0 HR FLOOR CONSTRUCTION: 0 HR ROOF CONSTRUCTION: 0 HR EXTERIOR NON-BEARING WALLS BASED ON SEPARATION DIST.30' OR MORE FIRE SEPARATION DISTANCE: 0 HR 10' TO 30' FIRE SEPARATION DISTANCE: 1 HR 5' TO 10' FIRE SEPARATION DISTANCE: 1 HR 5' OR LESS FIRE SEPARATION DISTANCE: 1 HR 7'-6" MIN. CEILING HEIGHTS (1208.2)FLASHING REQUIRED TO PREVENT MOISTURE (1405.4)ROOF FLASHING REQUIRED (1503.2, 1507.5.7)
FI
R
E
S
P
R
I
N
K
L
E
R
R
E
Q
U
I
R
E
D
T
H
R
O
U
G
H
O
U
T
(
N
F
P
A
1
3
)
-
S
E
C
T
I
O
N
9
0
3
.
3
.
1
.
1
FI
R
E
P
R
O
T
E
C
T
I
O
N
S
Y
S
T
E
M
S
:
ME
A
N
S
O
F
E
G
R
E
S
S
R
E
Q
U
I
R
E
M
E
N
T
S
CO
M
M
O
N
P
A
T
H
O
F
E
G
R
E
S
S
T
R
A
V
E
L
(
1
0
1
4
.
3
)
:
-N
O
T
T
O
E
X
C
E
E
D
7
5
F
T
-
G
R
O
U
P
A
-
2
(
W
I
T
H
S
P
R
I
N
K
L
E
R
)
2
E
X
I
T
S
R
E
Q
U
I
R
E
D
(
1
0
2
1
.
2
)
7"
M
A
X
.
R
I
S
E
1
1
"
M
I
N
.
T
R
E
A
D
-
G
R
O
U
P
A
-
2
ST
A
I
R
L
A
N
D
I
N
G
&
W
I
D
T
H
4
4
"
M
I
N
.
(
1
0
0
9
.
4
)
VE
R
T
I
C
A
L
R
I
S
E
M
A
X
.
1
2
'
(
1
0
0
9
.
1
0
)
EX
I
T
T
R
A
V
E
L
D
I
S
T
A
N
C
E
(
T
A
B
L
E
1
0
1
6
.
2
)
:
WI
T
H
S
P
R
I
N
K
L
E
R
S
Y
S
T
E
M
GR
O
U
P
A
-
2
=
2
5
0
F
T
CO
R
R
I
D
O
R
S
(
T
A
B
L
E
1
0
1
8
.
1
)
:
WI
T
H
S
P
R
I
N
K
L
E
R
S
GR
O
U
P
A
-
2
=
0
H
R
MI
N
I
M
U
M
W
I
D
T
H
O
F
4
4
"
(
T
A
B
L
E
1
0
1
8
.
2
)
DE
A
D
E
N
D
S
2
0
F
T
M
A
X
(
1
0
1
8
.
4
)
VE
R
T
I
C
A
L
E
X
I
T
E
N
C
L
O
S
U
R
E
S
(
1
0
2
2
.
2
)
:
3
S
T
O
R
I
E
S
O
R
L
E
S
S
=
1
H
R
F
I
R
E
B
A
R
R
I
E
R
AC
C
E
S
S
I
B
L
E
R
O
U
T
E
:
EL
E
V
A
T
O
R
R
E
Q
U
I
R
E
D
(
1
1
0
4
.
4
)
IN
T
E
R
I
O
R
E
N
V
I
R
O
N
M
E
N
T
:
NA
T
U
R
A
L
V
E
N
T
I
L
A
T
I
O
N
R
E
Q
U
I
R
E
D
(
1
2
0
3
.
4
)
8%
M
I
N
.
O
F
N
A
T
U
R
A
L
L
I
GH
T
R
E
Q
U
I
R
E
D
(
1
2
0
5
.
2
)
FIRE RATED CONSTRUCTION EXT. WALLS - FIRE SEPARATION DISTANCE (FSD) (TABLE 705.8)AREA OF UNPROTECTED OPENINGS IF FSD > 30' IS NOT REQ.D.IF FIRE SEPARATION DISTANCE (FSD) IS 3' TO < 5', 15% UNPROTECTED OPENINGS IF FIRE SEPARATION DISTANCE (FSD) IS 5' TO < 10', 25% UNPROTECTED OPENINGS IF FIRE SEPARATION DISTANCE (FSD) IS 10' TO < 15', 45% UNPROTECTED OPENINGS PARAPET NOT REQUIRED (705.11):- EXCEPTION 1: THE WALL IS NOT REQUIRED TO BE FIRE-RESISTANCE RATED IN ACCORDANCE WITH TABLE 602 BECAUSE OF FIRE SEPARATION DISTANCE (<45%).SHAFT ENCLOSURE (713.4)CONNECTING 3 STORIES OR LESS: 1 HR CONNECTING 4 STORIES OR MORE: 2 HR FIRE PARTITION (710.4) CONTINUOUS TO UNDERSIDE OF DECK ABOVE OR RATED FLR/ROOF ASSEMBLY CAN HAVE HORIZONTAL OFFSETS HORIZONTAL ASSEMBLIES (711.4)CONTINUOUS WITHOUT OPENINGS/PENETRATIONS (EXCEPT PER 712.1, 714.4, 715, 1009.3 & 1022.1) OPENING REQUIREMENTS (TABLE 716.5)1 HR FIRE BARRIERS (SHAFTS, EXITS):1 HR OPENING PROVIDE PORTABLE FIRE EXTINGUISHERS (906.1)1 HR FIRE PARTITION (DEMISING WALLS, ELEV. LOBBY):45 MIN. OPENING 30 MIN FIRE PARTITIONS (CORRIDORS) 20 MIN OPENING ARCHITECTURE/PLANNING/DEVELOPMENT/INTERIORS 1425 WEST MAIN ST. SUITE A -BOZEMAN, MONTANA 59715 TELEPHONE:(406) 587-1204 EMAIL: FHA@FAUREHALVORSEN.COM2016 FHA. It is unlawful to use any or all of these document without the expressed written consecnt of Faure Halvorsen Architects PC.A R C H I T E C T S F A U R E H A L V O R S E NDATE: 12/19/2018 5:45:21 PM G1.2TED MITCHELL, BOZEMAN GATEWAY SUBDIVISION PUD AVIATOR BUILDING 870 HARMON STREAM BLVD.BOZEMAN, MT 59718 2018 SITE MGENERAL NOTES JOB NO: 18-102
WE
S
T
M
A
I
N
S
T
.
V
I
E
W
1