Loading...
HomeMy WebLinkAboutLyman Springs Juction Box Monitoring and Control Improvements - Electrical PlansINDEX OF DRAWINGSP R O J E C T D R A W I N G SCERTIFICATIONENGINEERING TEAMCertification Of IndividualProject Design Disciplines AreIncluded On Their IndividualDrawings, Respectively.File: W:\Bozeman\05097-2014-004\040 Final Design\00-General\Plan Sheets\Cover Sheet.dwgLast Saved: By: Peter Manfredini Date: Friday, April 27, 2018 11:12:28 AMPlotted: By: Peter Manfredini Date: Friday, February 1, 2019 Layout: COVR1PREPARED FOR:CITY OF BOZEMANP R O J E C T D R A W I N G SLYMAN SPRING JUNCTION BOX MONITORINGAND CONTROLS IMPROVEMENTSBOZEMAN, MONTANACity Project No.:AE2S Project No.:FEB 2019CLIENT PROJECT NUMBERP05097-2014-004Advanced Engineering and Environmental Services, Inc.1288 N 14th Ave Unit 103 Bozeman, MT 59715(t) 406-219-2633 (f) 406-219-2635 www.ae2s.comELECTRICAL ENGINEERAdvanced Engineering andEnvironmental Services, Inc.ELECTRICAL ENGINEERAdvanced Engineering andEnvironmental Services, Inc.SHEETDESCRIPTIONG1 COVER SHEETG2 LOCATION AND VICINITY MAPE1 ELECTRICAL SYMBOLS AND ABBREVIATIONSE2 ELECTRICAL SITE PLANE3ENLARGED SITE PLANE4 CONTROL PANEL LAYOUTE5VARIOUS SCHEMATICSE6VARIOUS DETAILSE7 VARIOUS DETAILSE8VARIOUS DETAILSE9ANTENNA AND RADIO LOCATION AT LYMANWATER TREATMENT PLANT LEWIS &CLARKGOLDENVALLEYDEERLODGESILVERBOWLINCOLNFLATHEADGLACIERTOOLELIBERTYHILLBLAINEPHILLIPSVALLEYDANIELSSHERIDANROOSEVELTRICHLANDMcCONEDAWSONWIBAUXFALLONCARTERPOWDERRIVERCUSTERPRAIRIEGARFIELDPETROLEUMFERGUSCHOUTEAUPONDERATETONLAKESANDERSMINERALMISSOULACASCADEJUDITHBASINMUSSELSHELLROSEBUDWHEATLANDSWEETGRASSBROADWATERJEFFERSONPOWELLGRANITERAVALLIBEAVERHEADMADISONGALLATINMEAGHERYELLOWSTONESTILLWATERTREASUREBIG HORNCARBONPARKFile: W:\Bozeman\05097-2014-004\040 Final Design\00-General\Plan Sheets\Location.dwgLast Saved: By: Peter Manfredini Date: Friday, April 27, 2018 11:18:54 AMPlotted: By: Peter Manfredini Date: Friday, February 1, 2019 Layout: LGND2 SHEETPROJECT NUMBERCHECKED / APPROVEDDATEDRAWING TYPEPREPARED BYofDRAWING/Advanced Engineering and Environmental Services, Inc. l 1288 N 14th Ave Unit 103 Bozeman, MT 59715 l (t) 406-219-2633 (f) 406-219-2635 l www.ae2s.comR E C O R D D R A W I N G THESE RECORD DRAWINGS REPRESENT ASBUILT INFORMATION AS PROVIDED BY THE CONTRACTOR(S). ALL ASBUILT INFORMATION NEEDS TO BE FIELD VERIFIED. NO WARRANTY IS IMPLIED OR INTENDED. LYMAN SPRING JUNCTION BOX MONITORING AND CONTROLS IMPROVEMENTS CITY OF BOZEMAN BOZEMAN, MONTANA LOCATION AND VICINITY MAPRECORDPGMJASDMCFEB 2019P05097-2014-00422G2NHROT1G2PROJECT LOCATION MAPNHROT2G2PROJECT VICINITY MAPNHROT3G2PROJECT SITE MAPBOZEMANPROJECTLOCATIONPROJECTLOCATIONGENERAL NOTES1.ALL AREAS OF WORK ARE ON CITY OF BOZEMANPROPERTY. ACCESS IS THROUGH AN EASEMENTWITH LOCKED GATES. COORDINATE ACCESSWITH CITY OF BOZEMAN. File: W:\Bozeman\05097-2014-004\040 Final Design\06-Electrical\Autocad\Plan Sheets\E-Symbols and Abbreviations.dwgLast Saved: By: Peter Manfredini Date: Wednesday, April 25, 2018 7:31:06 AMPlotted: By: Peter Manfredini Date: Friday, February 1, 2019 Layout: LGND1 SHEETPROJECT NUMBERCHECKED / APPROVEDDATEDRAWING TYPEPREPARED BYofDRAWING/Advanced Engineering and Environmental Services, Inc. l 1288 N 14th Ave Unit 103 Bozeman, MT 59715 l (t) 406-219-2633 (f) 406-219-2635 l www.ae2s.comR E C O R D D R A W I N G THESE RECORD DRAWINGS REPRESENT ASBUILT INFORMATION AS PROVIDED BY THE CONTRACTOR(S). ALL ASBUILT INFORMATION NEEDS TO BE FIELD VERIFIED. NO WARRANTY IS IMPLIED OR INTENDED. LYMAN SPRING JUNCTION BOX MONITORING AND CONTROLS IMPROVEMENTS CITY OF BOZEMAN BOZEMAN, MONTANA ELECTRICAL SYMBOLS AND ABBREVIATIONSRECORDPGMJASDMCFEB 2019P05097-2014-00419E1CONDUIT SIZE & TYPECONDUCTOR SIZE OR TYPEQUANTITY OF CONDUCTORS2 - 1/C - #12 - 3/4"NUMBER OF CABLESPER CABLEDEVICE MOUNTED IN FIELDCONTROL CENTER (MCC)DEVICE MOUNTED IN MOTORTHERMAL OVERLOAD TRIP UNITSANTENNADUCT DETECTOR REMOTEINDICATORDUCT SMOKE DETECTORSMOKE DETECTORHEAT DETECTOR R=RATE OF RISE,135°=FIXED RATE MP=MOISTUREAND DUST PROOF C=COMBINATIONPULL STATIONFIRE ALARM HORN ONLYSTROBE ONLY (NUMBER INDICATESCANDELA RATING)PULL STATION (CHEMICAL)CHEMICAL HORN/STROBEFIRE CHIME/STROBEFIRE HORN/STROBE (NUMBERINDICATES CANDELA RATING.)OTHER ALARM HORN/STROBE(NUMBER INDICATES CANDELARATING.)MAGNETIC DOOR HOLDERFIRE SPRINKLER TAMPER SWITCHFIRE SPRINKLER FLOW SWITCHDRY SYSTEM PRESSURE SWITCHCIRCUIT LEGENDGROUND CONNECTIONCHASSIS CONNECTIONINDICATING LIGHT - LETTERDENOTES COLOR(P.T.T. = PUSH TO TEST)*GROUND RODLIGHTNING ARRESTORVSCONTROL OR INSTRUMENT SWITCH -LETTERS DENOTES FUNCTIONCURRENT TRANSFORMERPOTENTIAL TRANSFORMER - DRAWOUT TYPE WITH PRIMARY FUSESCONTROL STATIONCSINSTRUMENT - LETTERDENOTES TYPEAMMOTOR CIRCUITPROTECTOR (MCP)MOLDED CASECIRCUIT BREAKERONE-LINE DIAGRAM AND SCHEMATIC SYMBOLSSURGE CAPACITORCONTROL OR POTENTIALTRANSFORMERPOWER FACTOR CAPACITOR WITHFUSING AND INDICATING LIGHTSIFSSH151515VFLDPSEXISTING DEVICE TO BE REMOVED'E' INDICATES EXISTING DEVICE TOREMAINDOOR ACCESS CONTROLLERMAGNETIC DOOR SWITCHSECURITY KEYPADCARD READER (PROXIMITY TYPE)ELECTRIC DOOR STRIKEINTERCOM STATIONREQUEST TO EXITPAGING SYSTEM HORNPAGING SYSTEM SPEAKERVOLUME CONTROLFIRE ALARM CONTROL PANELFIRE ALARM REMOTEANNUNCIATOR PANELTELEPHONE OUTLET 'W' INDICATESWALL MOUNT AT +48''DATA OUTLETTELEPHONE/DATA OUTLETSECURITY CAMERAWIRELESS ACCESS POINT (WAP)EKPSSDSCRESICPFACPFAAPCOMMUNICATION/SECURITY/FIRE PROTECTION SYMBOLSPRESS TO TEST LAMP -LETTER DENOTES COLOROPERATING COIL, LETTER ORNUMBER DENOTES DEVICERTM52MENERGIZED TIMERCONTROL - N.C. N.O.PUSHBUTTONCONTACT ON, OFFDE-ENERGIZED TIMERCONTROL - N.C. N.O.DOUBLE CIRCUITPUSHBUTTON SWITCHTEMPERATURE SWITCH -N.C., N.O.FLOW SWITCH - N.C., N.O.LIQUID LEVEL SWITCH -N.C., N.O.ROFFRUNAUTO30AFUSE - NUMBERDENOTES RATINGSELECTOR SWITCHTORQUE SWITCH - N.C., N.O.CIRCUIT BREAKERMAGNETIC TRIPTHERMAL TRIPRUNNING TIME METERCONTACT - N.C., N.O.PRESSURE SWITCH - N.C., N.O.LIMIT SWITCH - N.C., N.O.DISCONNECT SWITCHR P.T.T.20MOTOR(NUMBER DENOTES HP)(TS = THERMAL SWITCH)TS20SENSOR20MOTOR(NUMBER DENOTES HP)MOTOR(NUMBER DENOTES HP)(SENSOR = SEAL FAIL)GENERATORFUSED DISCONNECT SWITCHGROUND/NEUTRALLINE REACTOR DRAW-OUT CIRCUIT BREAKERHEATERWALL MOUNTED/CEILING EXITLIGHT - LETTER & NUMBER SIMILARTO HID OR INCANDESCENTFIXTURE, SHADING DENOTEFACE(S) AND ARROW(S) IFREQUIREDWALL/CEILING MOUNTEDFLUORESCENT/INDUCTION/LEDFIXTURE - CAPITAL LETTERDENOTES TYPE, NUMBER DENOTESCIRCUIT, SMALL LETTER DENOTESSWITCH LEG.WALL MOUNTED/CEILING/HUNGLINEAR FIXTURES - LETTERS &NUMBERS SIMILAR TO FIXTURESABOVE.HALF SOLID FIXTURE INDICATESFIXTURE IS ON AN EMERGENCY ORUNSWITCHED LIGHTING CIRCUIT.NUMBER DENOTES DUPLEXCONVENIENCE OUTLET - CIRCUIT,INCHES DENOTE MOUNTINGHEIGHT IF OTHER THAN NORMAL,LETTERS SPECIFY OTHERCONDITIONS ie: WP, DP, OR GFI.GFCI RECEPTACLE.ABOVE COUNTER RECEPTACLEFLOOR MOUNTED RECEPTACLEDOUBLE DUPLEX RECEPTACLEGFIWP24''A/1dA/1dE/1E/1A/1dA/13aPSJJTSPECIAL PURPOSE RECEPTACLEJUNCTION BOX-CEILING/WALLMOUNTEDMECHANICAL THERMOSTATPHOTO SENSORSWITCH-NO MARKING IS SINGLEPOLE, 2 IS DOUBLE POLE, 3 IS3-WAY, 4 IS 4-WAYMOTORCIRCUITRY - EXPOSED, SURFACEMOUNTEDCIRCUITRY - BELOW GRADE ORFLOORCIRCUITRY - CONCEALED INSTRUCTUREGROUNDEXISTING LIGHT OR DEVICE TO BEREMOVEDPUSHBUTTON CONTROL STATIONDISCONNECT SWITCHACROSS THE LINE STARTERLIGHTING CONTACTOR (SEERESPECTIVE PLAN NOTE)DEVICE SYMBOLSREELECTRICAL ABBREVIATIONSAAMPERESLITLEVEL INDICATING TRANSMITTERACABOVE COUNTER (VERIFY HEIGHT)LTLIGHTACKACKNOWLEDGELMFLIQUID-TIGHT METALLIC CORE FLEXIBLE CONDUITA.F.F.ABOVE FINISHED FLOORAMAMMMETERMMOTOR STARTER OPERATING COILANNANNUNCIATORMAXMAXIMUMASAMMETER SWITCHMCMTHOUSAND CIRCULAR MILSAWGAMERICAN WIRE GAGEMCPMOTOR CIRCUIT PROTECTORMECHMECHANICALBKRBREAKERMFRMANUFACTURERBLDGBUILDINGMHMETAL HALIDEMINMINUTE OR MINIMUMCKTCIRCUITMTDMOUNTEDâ„„CENTER LINECOCONVENIENCE OUTLETNFNON-FUSEDCONNCONNECTIONSNCNORMALLY CLOSEDCONTRCONTRACTORNONORMALLY OPENCPCONTROL PANELNTCNOT CONNECTEDCPTCONTROL POWER TRANSFORMERCSCONTROL STATIONOL(S)OVERLOAD RELAY CONTACT(S)CTCURRENT TRANSFORMERPFPOWER FACTORDEDUAL ELEMENTPVCPOLYVINYLCHLORIDE CONDUITDISCDISCONNECTDPDAMP PROOFREQ'DREQUIREDRSRIGID STEEL CONDUITECELECTRICAL CONTRACTORRTMRUNNING TIME METERELECELECTRICALEMTELECTRICAL METALLIC TUBINGSDBCSOFT DRAWN BARE COPPEREPEXPLOSION PROOFSDSSPECIFIED IN OTHER DIVISION OF SPECIFICATIONSEQUIPEQUIPMENTSESERVICE ENTRANCESECSECOND OR SECONDARYF&IFURNISH AND INSTALLSIGSIGNALFUFUSE OR FUSIBLESOL VvSOLENOID VALVESPSINGLE POLEGFIGROUND FAULT INTERRUPTERSPECSSPECIFICATIONSGNDGROUNDSSNR''SOFT START'' NON-REVERSING SWITCHGRSGALVANIZED RIGID STEEL CONDUITSSR SW''SOFT START'' REVERSING SWITCHSUSESUITABLE FOR USE AS SERVICE ENTRANCEHDHEAVY DUTYHHHANDHOLETDTIME DELAYH/RHAND/REMOTETEMPTEMPERATUREHOAHAND-OFF-AUTOTSTATTHERMOSTATHOLHAND-OFF-LOCALHPHORSEPOWERUHUNIT HEATERHPSHIGH PRESSURE SODIUMHSHAND SWITCHVVOLTSHTRHEATERVFDVARIABLE FREQUENCY DRIVEHZHERTZ (CYCLES/SECOND)VMVOLTMETERVSVOLTMETER SWITCHIMCINTERMEDIATE METAL CONDUITVvVALVEINCANDINCANDESCENTINDINDICATION OR INDICATORWWATTS OR WIREW/WITHJBJUNCTION BOXWHMWATTHOUR METERWMWATT METERKVAKILOVOLT-AMPERESWWWIREWAYKVARKILOVOLT-AMPERES REACTIVEWPWEATHERPROOFKWKILOWATTSXFMRTRANSFORMERGENERAL NOTES1.EXISTING WATER TREATMENT PLANT MUST REMAIN INVIRTUALLY CONTINUOUS OPERATION DURINGCONSTRUCTION. COORDINATE SEQUENCING,SWITCHOVERS, AND SHORT DOWNTIME PERIODS WITHLOCAL UTILITY COMPANY, THE OWNER, AND THEENGINEER DURING CONSTRUCTION2.COORDINATE THE INSTALLATION OF ALL BELOW-GRADEAND CAST-IN-PLACE CIRCUITRY WITH OTHER TRADES.3.CONTRACTOR SHALL RETURN ALL DISTURBEDSURFACES AND SOILS TO ORIGINAL ORPRE-CONSTRUCTION CONDITION UNLESSSPECIFICALLY INDICATED OTHERWISE.4.CONTRACTOR SHALL LOCATE OR SHALL HAVE THESERVING UTILITIES LOCATE ALL UNDERGROUND CABLE,CONDUITS, PIPING, UTILITIES, ETC., PRIOR TOCOMMENCING CONSTRUCTION (UNDERGROUNDEXCAVATION). CONTRACTOR SHALL BE RESPONSIBLEFOR THE REPAIR OF ANY DAMAGES DUE TOCONSTRUCTION ACTIVITIES.5.EXISTING AND/OR NEW UNDERGROUND CONDUITS,DUCTBANK, AND OTHER CIRCUITRY SHOWN ON THEPLANS ARE INTENDED TO BE DIAGRAMMATIC INNATURE. CONTRACTOR IS RESPONSIBLE FOR FIELDCONFIRMING ALL CIRCUITRY AND ROUTING.6.CORE DRILL EXISTING STRUCTURES AS REQUIRED FORNEW CONDUIT INSTALLATIONS. PATCH AROUNDPENETRATIONS WITH NON-SHRINK GROUT AND PAINTTO MATCH SURROUNDING SURFACES WHEREAPPLICABLE.7.PLUG ALL UNUSED OPENINGS IN PANELS/EQUIPMENTLEFT BY REMOVALS, CUT OFF ALL ABANDONEDCONDUITS FLUSH WITH SURFACES AND FILL WITHNON-SHRINK GROUT8.WHERE THE PLANS CALL FOR DISCONNECTION ANDREMOVAL OF CIRCUITRY (CABLE AND CONDUIT),COMPLETE CONDUIT REMOVAL MAY NOT BE PRACTICALDUE TO THE LIMITS OF OTHER CONSTRUCTION. INSUCH CASES, THE CONTRACTOR SHALL DISCONNECTAND REMOVE ALL CIRCUITRY FROM CONDUITS THATARE TO BE DEMOLISHED, SHALL REMOVE THECONDUITS TO 18'' MINIMUM BELOW GRADE, AND SHALLBE ALLOWED TO CUT OFF THE CONDUITS ANDABANDON IN PLACE. THIS APPROACH SHALL ONLY BEUSED WHERE LARGE SCALE EXCAVATION DUE TOOTHER CONSTRUCTION ACTIVITIES IS NOT PLANNED INAN AREA. ALL SUCH CONDUIT ABANDONMENT IN PLACESHALL BE CONFIRMED WITH THE ENGINEER PRIOR TODOING SO.9.SCHEDULE 80 PVC CONDUIT IS ALLOWEDUNDERGROUND FOR CONDUIT STUB-OUTS.10.FIELD CONFIRM CONDUIT ROUTING. DO NOT ROUTECONDUIT ON BUILDING EXTERIOR UNLESS NOTEDOTHERWISE.11.ALL CABLE CONNECTIONS SHALL BE TORQUEDACCORDING TO MANUFACTURER REQUIREMENTS, ULSTANDARD 486A-B, NEC ANNEX I AS APPLICABLE.ADDITIONALLY, CONTRACTOR SHALL MARK EACHPROPERLY TORQUED BOLT/LOCKWASHER/NUTASSEMBLY WITH A PERMANENT PAINT STRIPE OVERBOTH THE BOLT/LOCKWASHER/NUT ASSEMBLY ANDTHE LUG ASSEMBLY TO INDICATE ANY CHANGES IN THEPOSITION OVER TIME.12.ALL CONDUCTORS ARE TO BE COPPER.13.PROVIDE AS BUILT DRAWINGS. DRAWINGS SHALL BENEAT AND LEGIBLE.14.COORDINATE ELECTRICAL WORK WITH OTHER TRADES.15.PROVIDE PANEL SCHEDULES FOR ALL NEW AND/ORMODIFIED PANELS. SCHEDULES SHALL BE TYPED.16.ANY ELECTRICAL BOX THAT BECOMES ABANDONEDDURING THE COURSE OF THE PROJECT SHALL HAVE ABLANK COVERPLATE.17.DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS INFIELD PRIOR TO COMMENCEMENT OF WORK.18.FINAL CONNECTIONS TO EQUIPMENT SHALL BE PERMANUFACTURER'S APPROVED WIRING DIAGRAMS,DETAILS, AND INSTRUCTIONS. IT SHALL BE THECONTRACTOR'S RESPONSIBILITY TO PROVIDEMATERIALS AND EQUIPMENT COMPATIBLE WITHEQUIPMENT ACTUALLY SUPPLIED.19.IT IS THE INTENT OF THESE DRAWINGS ANDSPECIFICATIONS TO ESTABLISH A STANDARD OFQUALITY. THE ENGINEER RESERVES THE RIGHT TOAPPROVE METHODS AND MATERIALS NOT REFLECTEDHEREIN.20.CONTRACTOR SHALL VISIT SITE PRIOR TO BID ANDVERIFY THAT CONDITIONS ARE AS INDICATED.CONTRACTOR SHALL INCLUDE IN THEIR BID, COSTSREQUIRED TO MAKE HIS WORK MEET EXISTINGCONDITIONS.21.WORK SHALL BE PERFORMED IN A WORKMANLIKEMANNER TO THE SATISFACTION OF THEARCHITECT/ENGINEER.22.WORK, MATERIALS, AND EQUIPMENT SHALL CONFORMTO THE LATEST EDITIONS OF LOCAL, STATE, ANDNATIONAL CODES AND ORDINANCES.23.VERIFY THE EXACT LOCATION OF EQUIPMENT TO BEFURNISHED BY OTHERS PRIOR TO ROUGH-IN.24.SYSTEMS SHALL BE TESTED FOR PROPER OPERATION.IF TESTS SHOW THAT WORK IS DEFECTIVE,CONTRACTOR SHALL MAKE CORRECTIONS NECESSARYAT NO COST TO OWNER.25.SYSTEMS SHALL BE COMPLETE, OPERABLE, ANDREADY FOR CONTINUOUS OPERATION. LIGHTS,SWITCHES, RECEPTACLES, MOTORS ETC. SHALL BECONNECTED AND OPERABLE.26.ALL CONDUIT IS TO BE SCH. 80 PVC WITH PVC STYLEBOXES. MAKE FINAL EQUIPMENT CONNECTIONS USINGLIQUID-TIGHT METALLIC FLEX.SFAPVCEECDACLINETYPE LEGENDNEW EQUIPMENTEXISTING EQUIPMENTFUTURE EQUIPMENTC File: W:\Bozeman\05097-2014-004\040 Final Design\06-Electrical\Autocad\Plan Sheets\E-Site Plan.dwgLast Saved: By: Peter Manfredini Date: Friday, February 1, 2019 4:20:55 PMPlotted: By: Peter Manfredini Date: Friday, February 1, 2019 Layout: SITE2 SHEETPROJECT NUMBERCHECKED / APPROVEDDATEDRAWING TYPEPREPARED BYofDRAWING/Advanced Engineering and Environmental Services, Inc. l 1288 N 14th Ave Unit 103 Bozeman, MT 59715 l (t) 406-219-2633 (f) 406-219-2635 l www.ae2s.comR E CO R D D R A W I N G THESE RECORD DRAWINGS REPRESENT ASBUILT INFORMATION AS PROVIDED BY THE CONTRACTOR(S). ALL ASBUILT INFORMATION NEEDS TO BE FIELD VERIFIED. NO WARRANTY IS IMPLIED OR INTENDED. LYMAN SPRING JUNCTION BOX MONITORING AND CONTROLS IMPROVEMENTS CITY OF BOZEMAN BOZEMAN, MONTANA ELECTRICAL SITE PLANRECORDPGMJASDMCFEB 2019P05097-2014-00429E2NHROT1E2OVERALL SITE LAYOUT400'0400'800'CONSTRUCTION NOTESINSTALL (4)TWISTED PAIR, 2/C-#16 AWG TINPLATED CU (PER PAIR) SHIELDED ARMOREDSIGNAL CABLE (OMNI CABLE - XL41604 ORAPPROVED EQUAL) BURIED AT 12'' MINIMUM, OROTHER MINIMUM DEPTH AS COORDINATED WITHENGINEER DURING CONSTRUCTION, IF ROCKBECOMES PROBLEMATIC WITH INSTALLATION. IFCABLE LENGTH DOES NOT MAKE FULL RUN,PROVIDE HANDHOLE AT SPLICE POINT ANDSPLICE CONDUCTORS USING WATER TIGHTSPLICES RATED FOR DIRECT BURIAL. ROUTE OFCABLE SHALL FOLLOW THE 18" LYMANTRANSMISSION MAIN AND AT NO POINT SHALL ITBE WITHIN 3'-0'' OF ROAD SHOULDER OR CLOSERTHAN 3'-0'' PARALLEL OFFSET WITH THETRANSMISSION MAIN. COORDINATE ROUTE WITHOWNER'S REPRESENTATIVE. SEE TRENCHDETAIL.INSTALL NEW LEVEL TRANSMITTER. SEE DETAIL2/E6 AND 3/E6.REMOVE AND REPLACE LEVEL TRANSMITTER.SEE DETAIL 1/E6.LOCATION OF NEW LYMAN DIVERSION CONTROLPANEL. SEE DETAIL1/E3, 1/E4, AND SHEET E5.LOCATION OF SOLAR POWER SYSTEM ANDLYMAN DIVERSION CONTROL PANEL. SEE SHEETE3.RADIO LINK BETWEEN LYMAN DIVERSIONCONTROL PANEL AND EXISTING LYMAN WATERTREATMENT PLANT CONTROL PANEL.LOCATION OF EXISTING WTP CONTROL PANEL.SEE SHEET E9.1234567GENERAL NOTES1.SEE SHEET E1 FOR GENERAL NOTES.76453NEW LYMANDIVERSIONCONTROL PANEL2EXISTINGLYMAN SPRINGJUNCTION BOXEXISTINGPARSHALLFLUME11EXISTINGLYMAN WATERTREATMENT PLANTEXISTING LYMAN PRV No. 21E42E61E61E31E93E6EXISTING LYMAN PRV No. 1 File: W:\Bozeman\05097-2014-004\040 Final Design\06-Electrical\Autocad\Plan Sheets\E-Site Plan.dwgLast Saved: By: Peter Manfredini Date: Friday, February 1, 2019 4:20:55 PMPlotted: By: Peter Manfredini Date: Friday, February 1, 2019 Layout: SITE3 SHEETPROJECT NUMBERCHECKED / APPROVEDDATEDRAWING TYPEPREPARED BYofDRAWING/Advanced Engineering and Environmental Services, Inc. l 1288 N 14th Ave Unit 103 Bozeman, MT 59715 l (t) 406-219-2633 (f) 406-219-2635 l www.ae2s.comR E CO R D D R A W I N G THESE RECORD DRAWINGS REPRESENT ASBUILT INFORMATION AS PROVIDED BY THE CONTRACTOR(S). ALL ASBUILT INFORMATION NEEDS TO BE FIELD VERIFIED. NO WARRANTY IS IMPLIED OR INTENDED. LYMAN SPRING JUNCTION BOX MONITORING AND CONTROLS IMPROVEMENTS CITY OF BOZEMAN BOZEMAN, MONTANA ENLARGED SITE PLANRECORDPGMJASDMCFEB 2019P05097-2014-00439E3NHROT1E3LYMAN DIVERSION CONTROL PANEL SITE4'04'8'TREE TO BEREMOVEDEXISTINGPRV No. 1SINGLE BATTERY ENCLOSUREWITH TWO BATTERY BANKSLYMAN DIVERSIONCONTROL PANELCONCRETE PAD APPROX. 14'-0''x8'-0''.CONTRACTOR CONFIRM AND ADJUSTAS REQUIRED FOR EQUIPMENTFURNISHED AT NO ADDITIONAL COSTTO OWNER. SEE DETAIL 2/E7SOLARARRAYACCESS ROADCONSTRUCTION NOTESSEE DETAILS 4/E6 AND 5/E6. COORDINATEAZIMUTH OF PANELS AND FINAL LOCATION WITHSOLAR SYSTEM SUPPLIER.TREE IS APPROXIMATELY 12 FT HIGH, 6-IN TRUNKDIAMETER CONIFER.SEE SHEET E5 FOR ALL WIRING DETAILS.PROVIDE 16, 6V DEEP CYCLE BATTERIES.BATTERIES SHALL BE FULLRIVER DC400-6 AGMSEALED 415 AH AT 20 HR, 7-YR WARRANTY OREQUAL. PRIOR APPROVED EQUIVALENTPRODUCT APPROVAL SHALL BE OBTAINED FROMENGINEER DURING BID PERIOD.INSTALL BATTERIES IN TWO SETS OF 8 INSEPARATE SEALABLE, INSULATED, LOCKABLEGROUND-MOUNTED ENCLOSURES. ENCLOSURESSHALL BE MINIMUM 39"x59"x28", 0.125"NON-FERROUS METAL MATERIAL, BUILT TO NEMA3R STANDARDS WITH SCREENED VENTILATIONLOUVERS.SEE E4 FOR CONTROL PANEL LAYOUT ANDPARTS LIST. SEE E7 FOR MOUNTING DETAIL.SEE DETAIL 3/E8 FOR LYMAN SPRING JUNCTIONBOX ANTENNA MOUNTING.COORDINATE AND PROVIDE APPROPRIATELYSIZED ROTARY DISCONNECT FOR 1000V, 25ASOLAR ARRAY POWER SYSTEM. DISCONNECTSTO BE INSTALLED PER TYPICAL PANEL POWERWIRING FOUND ON SHEET E5.12345678GENERAL NOTES1.SEE SHEET E1 FOR GENERAL NOTES.12456378(3) DISCONNECTS FOR:BATTERY BANK No. 1,BATTERY BANK No. 2,AND PHOTOVOLTAIC ARRAY 30 50 70 90110130140 LYMAN DIVERSIONCONTROL PANEL30 50 70 90110130140 30 50 7090 110130140E/IPCOAXCOAXAZIMUTH 218.57°MOUNTED AT 12'-0''ABOVE GROUND LEVELSEE DETAIL 3/E8LYMAN DIVERSION CONTROL PANELCOAXCOAXCOAXAZIMUTH 38.56°MOUNTED AT 15'-0''ABOVE GROUND LEVELSEE DETAIL 1/E8E/IPNEW RADIO CONTROL PANELEXISTINGETHERNET SWITCHSCADA NETWORK (ETHERNET/IP)COAXIAL CABLEE/IPCOAXPOW ERNOT U SEDNOT U SED+24VDCDC NEUTCHASSIS GNDUNDERGROUNDARMORED SIGNAL CABLE~LYMAN SPRINGJUNCTION BOX~LYMAN PRV No. 2JUNCTION BOXLYMAN WATER TREATMENT PLANTSLC 5/04 CPUFORCERUNDH+FLT RS232 BAT T REMPROGRUNE/IPEXISTING CONTROL PANELFile: W:\Bozeman\05097-2014-004\040 Final Design\06-Electrical\Autocad\Plan Sheets\E-Panel Layout.dwgLast Saved: By: Peter Manfredini Date: Friday, February 1, 2019 4:22:39 PMPlotted: By: Peter Manfredini Date: Friday, February 1, 2019 Layout: PANL4 SHEETPROJECT NUMBERCHECKED / APPROVEDDATEDRAWING TYPEPREPARED BYofDRAWING/Advanced Engineering and Environmental Services, Inc. l 1288 N 14th Ave Unit 103 Bozeman, MT 59715 l (t) 406-219-2633 (f) 406-219-2635 l www.ae2s.comR E C O R D D R A W I N G THESE RECORD DRAWINGS REPRESENT ASBUILT INFORMATION AS PROVIDED BY THE CONTRACTOR(S). ALL ASBUILT INFORMATION NEEDS TO BE FIELD VERIFIED. NO WARRANTY IS IMPLIED OR INTENDED. LYMAN SPRING JUNCTION BOX MONITORING AND CONTROLS IMPROVEMENTS CITY OF BOZEMAN BOZEMAN, MONTANA CONTROL PANEL LAYOUTRECORDPGMJASDMCFEB 2019P05097-2014-00449E436''24''PARTS LISTMARKDESCRIPTION36''x24''x12'' WALL MOUNTED ENCLOSURE - CSD362412SS WITH PADLOCKABLE HANDLESUB-PANEL - CP3624MICROLOGIX 1400 - 1766-L32BXBDIN RAILWIREWAY WITH COVER, SIZE TO FIT - 2'' PANDUITDIN RAIL MOUNTED CIRCUIT BREAKERS - EATON WMZT OR PRIOR APPROVED EQUALSURGE PROTECTOR - TTC-6P-1X2-48VDC-UT-ITHERMOSTAT - STEGO 011409-00TERMINAL BLOCK (GRAY), SCREW CONNECTION, (ASSOCIATED END BARRIERS, ENDSTOPS, SEPARATION PLATES, ETC.) - ALLEN BRADLEY 1492-J4 OR PRIOR APPROVEDEQUALGROUND BUSS BAR(3) 10 WATT HEATER - PTC 060401-00SOLAR CONTROLLER - CONNEXT MPPT 60 150LIGHTNING ARRESTER - POLYPHASER TSX-NFF OR PRIOR APPROVED EQUALINET-II RADIO48VDC TO 24VDC CONVERTER - PHOENIX CONTACT QUINT-PS/48DC/24DC/5-2320144FUSE TERMINALS WITH FUSES, LED/NEON BLOWN FUSE INDICATORS - ALLEN BRADLEYPHOENIX CONTACT OR PRIOR APPROVED EQUALANALOG INPUT MODULE - 1762-IF4YAGI ANTENNA - GE MDS CLEARWAVE 97-3194-A14LMR 400VOLTAGE MEASURING TRANSDUCER - MACX MCR-VDC-PT - 2906243RELAYANALOG IO SURGE SUPPRESSOR - PHOENIX CONTACT - PLUGTRAB PT 1X2-24DC-ST ORPRIOR APPROVED EQUAL120VAC/24VDC POWER SUPPLY1234567891011121314151617181920212223123455555444678910111111121314151E4CONTROL PANEL LAYOUTFRONT VIEWSUBPANEL VIEW6'' MIN.CLEARANCE6'' MIN. CLEARANCE 2'' MIN.CLEARANCE2'' MIN.CLEARANCE 16GENERAL NOTES1.SEE SHEET E1 FOR GENERAL NOTES.314131819131918143E4NETWORK DIAGRAMCONSTRUCTION NOTESPROVIDE GE MDS INET-II RADIO IN NEW LYMANDIVERSION CONTROL PANEL. RADIO WILLCONNECT TO GE MDS CLEARWAVE 97-4194-A14ANTENNA VIA LMR-400. INSTALL POLYPHASERTSX-NFF OR PRIOR APPROVED EQUAL FORLIGHTNING PROTECTION. ANTENNA WILL BEINSTALLED AT 12'-0'' ABOVE GROUND LEVEL WITHAZIMUTH OF 218.57 DEGREES.INSTALL GE MDS INET-II RADIO IN NEW RADIOCONTROL PANEL LOCATED AT LYMAN WTP.RADIO WILL CONNECT TO GE MDS CLEARWAVE97-3194-A14 ANTENNA VIA LMR-400. INSTALLPOLYPHASER TSX-NFF OR PRIOR APPROVEDEQUAL FOR LIGHTNING PROTECTION. ANTENNAWILL BE INSTALLED AT 15'-0'' ABOVE GROUNDLEVEL WITH AZIMUTH OF 38.56 DEGREES.PROVIDE ALL REQUIRED ANTENNA JUMPERCABLES BETWEEN RADIO AND LIGHTNINGARRESTOR PER MANUFACTURER'SRECOMMENDATIONS.123121720212233TELEMETRY INTERFACEJUNCTION BOX NEMA 12,STEEL ENCLOSUREGROUND PLATE13RADIO PANEL GENERAL NOTES1.WALL MOUNT ENCLOSURE WITH SUB PANELSHALL BE A NEMA 12, 12 GAUGE STEEL.2.APPROXIMATE DIMENSIONS: H: 16", W: 12", D: 6"3.SUB-PANEL LAYOUT IS TO BE USED AS AGENERAL LAYOUT. EXACT DIMENSIONS,COMPONENT QUANTITIES AND EXACT LAYOUTTO BE DETERMINED BY THE SYSTEMSINTEGRATOR.4.PANEL TO BE UL 508 LISTED16''12''14232E4RADIO PANEL LAYOUT622 TYPICAL PANEL POWER WIRINGSCALE: NONE11CBLOADLINE22FUSEPLCLNG48VDC / 24VDCCONVERTERLNGFUSE+24VDCRADIOFUSE34-24VDC+24VDC-24VDCSOLARCONTROLLER12+48VDC-48VDC+-+-+-+-+-+-+-+-BATTERY BANKNo. 1+-+-+-+-+-+-+-+-BATTERY BANKNo. 2CB+-PHOTOVOLTAICARRAY No. 1+-+-PHOTOVOLTAICARRAY No. 2+-+-PHOTOVOLTAICARRAY No. 3+-+-PHOTOVOLTAICARRAY No. 4+-56R1R1FIELD/AS NOTED LYMAN DIVERSION CONTROL PANEL12340/1/1+-AI1243LYMAN DIVERSION CONTROL PANEL0/1/2+-AIHEATER+24VDC-VDCFIELD/AS NOTEDSIGNALTRANDUCER+54VDC++24VDC--VDC-VDC0/1/0+-AIFUSEHEATERHEATER+24VDC-VDC+24VDC-VDC0/0/0LYMAN DIVERSIONCONTROL PANELSPD FAULTBATTERY LEVEL+-PTLYMAN SPRINGJUNCTION BOX+-PTLYMAN PRV No. 2JUNCTION BOXLYMAN SPRINGJUNCTION BOXLEVELLYMAN PRV No. 2LEVELFUSEFUSEANALOG I/OSURGEPROTECTIONANALOG I/OSURGEPROTECTIONSURGE PROTECTIONDEVICEFile: W:\Bozeman\05097-2014-004\040 Final Design\06-Electrical\Autocad\Plan Sheets\E-Various Schematics.dwgLast Saved: By: Peter Manfredini Date: Friday, February 1, 2019 4:22:29 PMPlotted: By: Peter Manfredini Date: Friday, February 1, 2019 Layout: DIAG5 SHEETPROJECT NUMBERCHECKED / APPROVEDDATEDRAWING TYPEPREPARED BYofDRAWING/Advanced Engineering and Environmental Services, Inc. l 1288 N 14th Ave Unit 103 Bozeman, MT 59715 l (t) 406-219-2633 (f) 406-219-2635 l www.ae2s.comR E C O R D D R A W I N G THESE RECORD DRAWINGS REPRESENT ASBUILT INFORMATION AS PROVIDED BY THE CONTRACTOR(S). ALL ASBUILT INFORMATION NEEDS TO BE FIELD VERIFIED. NO WARRANTY IS IMPLIED OR INTENDED. LYMAN SPRING JUNCTION BOX MONITORING AND CONTROLS IMPROVEMENTS CITY OF BOZEMAN BOZEMAN, MONTANA VARIOUS SCHEMATICSRECORDPGMJASDMCFEB 2019P05097-2014-00459E51E5GENERAL NOTES1.SEE SHEET E1 FOR GENERAL NOTES.AE5AE5 FOUNDATION DETAILSCALE: NONE(id num)ARRAY SUPPORT COLUMN (BYSOLAR SYSTEM SUPPLIER)24" DIA. SUPPORT PIER#5 VERTICAL BAR (TYP. OF 8)#5 TIES AT 8" ON CENTER1'-0" 8'-0" MIN. 2'-0" MIN.3'-0"39''x78'' PHOTOVOLTAIC PANELSMOUNTED PER MANUFACTURER'SRECOMMENDATIONS (TYP. OF 8)GRADEPOLE HEIGHT: 18'-0" MINIMUM (SIZE AS REQUIRED)8"4'-0" MIN.NOTE: SOLAR ARRAY SHALL PROVIDEA MINIMUM OF 3800 WATT-HRS/DAYAT THE ARRAY LOCATION.NOTE: COORDINATE AZMUTH OFPANELS AND FINAL LOCATIONWITH SOLAR SYSTEM SUPPLIER.File: W:\Bozeman\05097-2014-004\040 Final Design\06-Electrical\Autocad\Plan Sheets\E-Various Details.dwgLast Saved: By: Peter Manfredini Date: Friday, February 1, 2019 4:25:50 PMPlotted: By: Peter Manfredini Date: Friday, February 1, 2019 Layout: DETL6 SHEETPROJECT NUMBERCHECKED / APPROVEDDATEDRAWING TYPEPREPARED BYofDRAWING/Advanced Engineering and Environmental Services, Inc. l 1288 N 14th Ave Unit 103 Bozeman, MT 59715 l (t) 406-219-2633 (f) 406-219-2635 l www.ae2s.comR E C O R D D R A W I N G THESE RECORD DRAWINGS REPRESENT ASBUILT INFORMATION AS PROVIDED BY THE CONTRACTOR(S). ALL ASBUILT INFORMATION NEEDS TO BE FIELD VERIFIED. NO WARRANTY IS IMPLIED OR INTENDED. LYMAN SPRING JUNCTION BOX MONITORING AND CONTROLS IMPROVEMENTS CITY OF BOZEMAN BOZEMAN, MONTANA VARIOUS DETAILSRECORDPGMJASDMCFEB 2019P05097-2014-00469E61E6PARSHALL FLUME IMAGE (PRV2)2E6LYMAN SPRING JUNCTION BOX3E6LYMAN SPRING JUNCTION BOXCONSTRUCTION NOTESINSTALL NEW SUBMERSIBLE LEVELTRANSDUCER IN EXISTING STILLING TUBELOCATION SHOWN. LEVEL TRANSDUCER SHALLBE A KPSI 720 RATED FOR 0-2 PSI. TRANSDUCERSHALL BE STAINLESS STEEL WITH A PORTEDNOSE CAP. PROVIDE WITH ANEROID BELLOWSACCESSORY INSTALLED WITHIN THE LOCALJUNCTION BOX. INCLUDE BUILT IN LIGHTNINGPROTECTION OPTION. PROVIDE KPSI CABLEHANGER 12-90-0931 TO SUPPORT AND HANG THECABLE FROM THE EXISTING HANGINGHARDWARE.INSTALL NEW 12"x12"x6"D NEMA 4X STAINLESSSTEEL JUNCTION BOX WITH 12-POINT TERMINALSTRIP AND PADLOCKABLE HARDWARE. LEVELTRANSDUCER CABLE SHALL BE ROUTED UP INTOJUNCTION BOX AND LANDED TO TERMINALSWITHIN THE JUNCTION BOX. LEVELTRANDUCER'S ANEROID BELLOWS SHALL BELOCATED WITHIN THE JUNCTION BOX. 4-2/C-#16ARMORED CABLE SHALL ROUTE INTO JUNCTIONBOX AND LAND ON TERMINAL STRIP PROVIDED.INSTALL NEW 20"x20"x12"D NEMA 4X STAINLESSSTEEL JUNCTION BOX WITH 12-POINT TERMINALSTRIP AND PADLOCKABLE HARDWARE. LEVELTRANSDUCER CABLE SHALL BE ROUTED UP INTOJUNCTION BOX AND LANDED TO TERMINALSWITHIN THE JUNCTION BOX. LEVELTRANDUCER'S ANEROID BELLOWS SHALL BELOCATED WITHIN THE JUNCTION BOX. 4-2/C-#16ARMORED CABLE SHALL ROUTE INTO JUNCTIONBOX AND LAND ON TERMINAL STRIP PROVIDED.SOLAR ARRAY THAT IS SHOWN IS BASED ONSYSTEM FROM SOLAR PLEXUS (MISSOULA, MT).AT MINIMUM, ANY ARRAY PROVIDED SHALL BEASSEMBLED AND TESTED BY A SINGLE SYSTEMSUPPLIER, AND SHALL PROVIDE A MINIMUM OF3800 WATT-HRS/DAY AT THE SPECIFIED ARRAYLOCATION. PANELS SHALL BE TUV CERTIFIED.PANEL DESIGN LOAD SHALL BE 178 LB/FT²MINIMUM. PROVIDE 25-YR LINEAR PERFORMANCEWARRANTY AND 10-YR PRODUCT WARRANTY.PROVIDE ANTI-REFLECTIVE COATING FOR GLASS.PANELS SHALL BE SOLARWORLD SUNMODULEPLUS SW 285-300 MONO 5 BUSBAR OR EQUAL.SUPPORT COLUMN, FASTENERS AND ALL OTHERMETALS SHALL BE NON-FERROUS METAL ORPRIMED AND FACTORY-FINISH COATED WITHFIELD TOUCH-UP WITH MANUFACTURER'SRECOMMENDED COATING SYSTEM.INSTALL (4) TWISTED PAIR, 2/C-#16 SHIELDEDARMORED CABLE ALONG BACK FACE OFCONCRETE SLAB. USE INSULATED CABLECLAMPS PER MANUFACTURER'SRECOMMENDATIONS.REFER TO DETAIL 5/E8 FOR CABLE AND CONDUITROUTING.123456121GENERAL NOTES1.SEE SHEET E1 FOR GENERAL NOTES.5E64E6POLE MOUNTED PHOTOVOLTAIC PANELS DETAILSCALE: NONE45~ARMOREDCABLE TOLYMAN SPRINGJUNCTION BOXLEG EXTENDS DOWNFACE OF SLAB36SCALE: NONESCALE: NONESCALE: NONE STRUT MOUNTING STAND DETAILSCALE: NONEEQPM011UPPER CROSS BRACE. WELDON CLOSED END PLATES1/8" THICK ALUMINUM MOUNTING PLATE.SIZE AS REQUIRED BY EQUIPMENTEQUIPMENT AS INDICATED ON PLANSCH. 80 PVC MOUNTED WITH STAINLESSSTEEL CLAMPS AND ALL STAINLESSSTEEL HARDWARE.LOWER CROSS BRACE. PROVIDE 12GAUGE 304 SST STRUT CHANNEL,1-5/8"x1-5/8". UNISTRUT OR EQUAL.4'-6" LONG VERTICAL MEMBER. (TYP.)PROVIDE 12 GAUGE 304 SST STRUTCHANNEL, 1-5/8"x1-5/8". UNISTRUT OR EQUAL.1/8" THICK GUSSET. (TYP. OF 2)FLOOR CHANNEL W/2-1/2"x4" STAINLESSSTEEL WEDGE TYPE ANCHOR BOLTS(3" MIN. EMBEDMENT) IF NOT CAST IN PLACEEXTEND CHANNEL 36" BELOW GRADE WHENSECURING TO OUTDOOR STRUCTURES12''12''48'' A.F.F. OR GRADEUNLESS INDICATED OTHERWISE HEIGHT AS REQ'DBY EQPM. 12'' MIN.WIDTH AS REQ'DBY EQPM. 12'' MIN.EMBED OUTDOOR STANDSUPPORTS IN CONCRETE.PROVIDE PAD SEE 2/E7.SIDE VIEWFRONT VIEWNOTE:1. CONSTRUCT STAND USING HOT DIPPED GALVANIZED 1 5/8"x 1 5/8" CHANNEL,B-LINE SERIES B24, OR OR EQUAL.2. FASTEN ALL CONNECTIONS USING MANUFACTURER'S TYPE 316 STAINLESSSTEEL CONNECTORS & STAINLESS STEEL BOLTS, WASHERS & NUTS.NOTE: DIMENSIONS SHOWN AREAPPROXIMATE. FINAL OVERALLDIMENSIONS SHALL BE COORDINATEDPRIOR TO CONSTRUCTION WITH ENGINEER . PLAN VIEW SECTION VIEW PAD SHALL EXTEND 1'-0''BEYOND THE EQUIPMENTPROVIDE NUMBER, SIZE,AND LOCATION OF PADPENETRATIONS PEREQUIPMENT SUPPLIED.VERIFY WITH ENGINEER.1'-0"MINPER MANUFACTURER'S REQ1'-0"MIN1'-0" MIN PER MANUFACTURER'S REQ1'-0" MIN 2'-0"2'-0"1'-0"24TYPICAL EQUIPMENT PAD DETAILSCALE: NONESTRU0172- #5#5 @ 12" OC2'-0" 4"1'-0"1'-0"1'-0"1'-0" 2" CLR3" CLR OUTLINE OF EQUIPMENTNOT TO SCALECOMPACTED CLASS 5AGGREGATEFINISHED GRADE, SLOPEAWAY FROM PAD.#5 @ 12" OC EW#5 @ 12" OC EW~EQUIPMENT OUTLINEFile: W:\Bozeman\05097-2014-004\040 Final Design\06-Electrical\Autocad\Plan Sheets\E-Various Details.dwgLast Saved: By: Peter Manfredini Date: Friday, February 1, 2019 4:25:50 PMPlotted: By: Peter Manfredini Date: Friday, February 1, 2019 Layout: DETL7 SHEETPROJECT NUMBERCHECKED / APPROVEDDATEDRAWING TYPEPREPARED BYofDRAWING/Advanced Engineering and Environmental Services, Inc. l 1288 N 14th Ave Unit 103 Bozeman, MT 59715 l (t) 406-219-2633 (f) 406-219-2635 l www.ae2s.comR E C O R D D R A W I N G THESE RECORD DRAWINGS REPRESENT ASBUILT INFORMATION AS PROVIDED BY THE CONTRACTOR(S). ALL ASBUILT INFORMATION NEEDS TO BE FIELD VERIFIED. NO WARRANTY IS IMPLIED OR INTENDED. LYMAN SPRING JUNCTION BOX MONITORING AND CONTROLS IMPROVEMENTS CITY OF BOZEMAN BOZEMAN, MONTANA VARIOUS DETAILSRECORDPGMJASDMCFEB 2019P05097-2014-00479E71E7GENERAL NOTES1.SEE SHEET E1 FOR GENERAL NOTES.2E7 2WTP SCADA ANTENNA MAST DETAIL SCALE: NONEANTN0081" RIGID STEEL CONDUITW/FLOOR FLANGE, (TYP. 4)WELD CHANNEL TO RIGID STEELCONDUITS, (TYP.)UNISTRUT #P1000, OREQUAL, CHANNEL. (TYP. 4)WALLCOORDINATE ANCHOR TYPE W/BUILDING EXTERIOR CONSTRUCTIONNOTE: SANDBLAST & PAINT BRACKETW/OXIDATION RESISTANT PAINT.COORDINATE COLOR W/ARCHITECT.PLAN VIEWYAGI-STYLE DIRECTIONAL ANTENNACOORDINATE LOCATION ANDORIENTATION FOR OPTIMUM RECEPTION.CONNECT GROUND TOMAST/ANTENNA BRACKETSTRAP GROUND CONDUCTOR TO MASTAT 2 FOOT INTERVALS1 1/2" RIGID STEEL MASTGROUND ANTENNA, MAST & ANTENNACABLE PER MFR'S RECOMMENDATIONSUNISTRUT #P1000, OR EQUAL,CHANNEL. (TYP. 4)#6 AWG COPPER, BARE STRANDEDGROUND CONDUCTORUNISTRUT, OR EQUAL, STRAP.(TYP. 2)INSULATING BUSHING1 1/2" RIGID STEEL CONDUITTHRU WALLROUTE TO 5/8"x10' COPPER CLADSTEEL GROUND RODROUTE COAX CABLE TO LIGHTNINGARRESTOR IN NEW RADIO PANELSECTIONWALL18''4''48'' - 72'' AS REQUIRED APPROX. 26'ABOVE GRADEWATERTIGHT CONNECTOROR WEATHERHEADCOAXIAL ANTENNA CABLEPROVIDE DRIP LOOP#6AWG COPPER, BARE STRANDED GROUNDCONDUCTOR IN 3/4" RMC. BOND CONDUCTORTO GROUND ROD INSTALLED OUTSIDE.CONDUCTOR SHALL CONNECT TO GROUNDPLATE INSTALLED INSIDE RADTIO PANELNEW RADIO PANELEXISTING TOPSOILNEWTOPSOIL~~MARKING TAPETHOROUGHLY TAMPEDBACKFILL TWO LAYERS2TYPICAL TRENCH DETAILSCALE: NONEEQPM042EXISTING GRADESEED NEW GRADE(OVERFILL TO ACCOUNTFOR INITIAL SETTLING)EXISTING TOPSOILNATIVE SOILNATIVE SOILNATIVE SOIL LIGHTLYTAMPED, MINIMUM 3"ABOVE AND BELOWARMORED SIGNAL CABLE.ARMOREDSIGNAL CABLENATIVE SOILNATIVE SOIL3'' 6'' 18''GRADE4'' ADDITIONAL CONCRETE ENCASEMENT(ALL SIDES)2HANDHOLE DETAILSCALE: NONEEQPM0391 CUBIC YARD MINIMUM GRAVELBED FOR DRAINAGE (6'' MINDEPTH)GRADEOPEN BOTTOM HANDHOLE SHALL BEPOLYMER CONCRETE/FIBERGLASS PULLBOXWITH NON-SKID COVER AND (2) STAINLESSSTEEL PENTA HEAD COVER BOLTS. COVERSHALL BE RATED HEAVY DUTY, FOR15,000LBS/100SQ. INCH ACCIDENTALVEHICLE LOAD (TIER 15). DIMENSIONS17''x30''x18''D, HUBBELL/QUAZITE 'PG' SERIESOR EQUAL. COVER ENGRAVED 'ELECTRICAL'.2'' CONDUIT DRAIN IN BOTTOM OF BOXSLOPE GRADE AWAY SLIGHTLY TOFACILITATE DRAINAGE.CONDUITS (DUCTS)/CABLES PER PLANCONDUITS (DUCTS)/CABLES PER PLAN.CONDUIT OPENINGS SHALL BE HIGHERTHAN DRAIN OPENING.MANUFACTURERSUBMERSIBLETRANSDUCER CABLE1-1/2'' SCH. 80PVC CONDUIT3'' SCH. 80PVC CONDUITJUNCTION BOXARMORED CABLE AND TRANSDUCERS DETAILSCALE: NONEPRV No. 2JUNCTION BOXLYMAN SPRINGJUNCTION BOXEXISTINGSTILLING TUBETO LYMAN DIVERSIONCONTROL PANELROUTE CABLE SHOWN ON 1/E6PRIOR TO RUNNING BELOW GRADECONDUIT THRU WALL W/WATER-TIGHT FITTING ON THEOUTSIDE & INSULATING BUSHING ONTHE INSIDE. PACK W/ DUCT SEAL.JUNCTION BOXTERMINAL STRIPANEROIDBELLOWSJUNCTION BOXTERMINAL STRIPANEROIDBELLOWS GRADE4-PAIR TWISTED, SHIELDEDARMORED CABLE (4-2/C-#16SHIELDED TWISTED PAIR)STRAP ARMORED CABLE TOSTRUT USING INSULATEDCABLE CLAMPSNOTE: MOUNT ANTENNA BRACKET TO MASTWITH STAINLESS STEEL U-BOLTS, NUTS,WASHERS & LOCK WASHERS. DRILLTENON/MAST & FASTEN WITH TWO 3/8"x 3"STAINLESS STEEL BOLTS, NUTS, WASHERSAND LOCK WASHERS. SEAL BETWEEN TENON& MAST CONDUIT WITH SILICONE CAULK.NOTE: COORDINATE EXACTLOCATION OF ANTENNAMAST. SEE PLAN.NOTE: GROUNDANTENNA/COAX CABLE PERMFR RECOMMENDATIONS.INCLUDE GROUNDING KIT.12'-0'' ABOVE GRADE1LYMAN SPRING JBOX ANTENNA MAST DETAILSCALE: NONEANTN011ROUTE ANTENNA CABLEAND #6 BARE STRANDED GROUNDALONG MAST, FASTEN EVERY 12''RADIO ANTENNA1 1/2'' RIGID METAL WEATHERHEAD1'-0'' MAXIMUM ABOVE ANTENNA.CONTROLENCLOSURECOAXIAL ANTENNA CABLE.PROVIDE DRIP LOOP.TO LYMAN SPRINGJUNCTION BOXTO PRV No. 2JUNCTION BOX3" SCH. 80 PVC.EXTEND CONDUITPAST CONCRETEAPPROX. 14'ABOVE GRADEFile: W:\Bozeman\05097-2014-004\040 Final Design\06-Electrical\Autocad\Plan Sheets\E-Various Details.dwgLast Saved: By: Peter Manfredini Date: Friday, February 1, 2019 4:25:50 PMPlotted: By: Peter Manfredini Date: Friday, February 1, 2019 Layout: DETL8 SHEETPROJECT NUMBERCHECKED / APPROVEDDATEDRAWING TYPEPREPARED BYofDRAWING/Advanced Engineering and Environmental Services, Inc. l 1288 N 14th Ave Unit 103 Bozeman, MT 59715 l (t) 406-219-2633 (f) 406-219-2635 l www.ae2s.comR E C O R D D R A W I N G THESE RECORD DRAWINGS REPRESENT ASBUILT INFORMATION AS PROVIDED BY THE CONTRACTOR(S). ALL ASBUILT INFORMATION NEEDS TO BE FIELD VERIFIED. NO WARRANTY IS IMPLIED OR INTENDED. LYMAN SPRING JUNCTION BOX MONITORING AND CONTROLS IMPROVEMENTS CITY OF BOZEMAN BOZEMAN, MONTANA VARIOUS DETAILSRECORDPGMJASDMCFEB 2019P05097-2014-00489E81E8GENERAL NOTES1.SEE SHEET E1 FOR GENERAL NOTES.2E84E85E83E8 File: W:\Bozeman\05097-2014-004\040 Final Design\06-Electrical\Autocad\Plan Sheets\E-WTP Building.dwgLast Saved: By: Peter Manfredini Date: Friday, February 1, 2019 4:33:47 PMPlotted: By: Peter Manfredini Date: Friday, February 1, 2019 Layout: PLAN9 SHEETPROJECT NUMBERCHECKED / APPROVEDDATEDRAWING TYPEPREPARED BYofDRAWING/Advanced Engineering and Environmental Services, Inc. l 1288 N 14th Ave Unit 103 Bozeman, MT 59715 l (t) 406-219-2633 (f) 406-219-2635 l www.ae2s.comR E C O R D D R A W I N G THESE RECORD DRAWINGS REPRESENT ASBUILT INFORMATION AS PROVIDED BY THE CONTRACTOR(S). ALL ASBUILT INFORMATION NEEDS TO BE FIELD VERIFIED. NO WARRANTY IS IMPLIED OR INTENDED. LYMAN SPRING JUNCTION BOX MONITORING AND CONTROLS IMPROVEMENTS CITY OF BOZEMAN BOZEMAN, MONTANA ANTENNA AND RADIO LOCATION AT LYMAN WATER TREATMENT PLANTRECORDPGMJASDMCFEB 2019P05097-2014-00499E9NHROT1E9LYMAN WATER TREATMENT PLANT12"02'4'6'8'10'CONSTRUCTION NOTESPOLE MOUNTED 900MHZ YAGI ANTENNA. SEEDETAIL 1/E8 FOR MOUNTING AND CABLEROUTING INFORMATION.NEW RADIO PANEL. LOCATED BEHIND TANK IN2/E9 IMAGE. SEE 2/E4 FOR FURTHER DETAILS.CONTRACTOR TO ROUTE CABLE / CONDUITTHROUGH WALL AS REQUIRED. CONTRACTORWILL ALSO RESTORE CONDUIT OPENING WITHNON-SHRINK GROUT.123GENERAL NOTES1.SEE SHEET E1 FOR GENERAL NOTES.EXISTINGCONTROL PANELNEW RADIO PANEL(SEE SHEET E4)YAGI ANTENNA3E9NEW YAGI ANTENNA LOCATION2E9EXISTING CONTROL PANEL AND NEW RADIO PANEL2E93E921EXISTINGNETWORK RACK2-1/C-#12 + 1-1/C-GND IN 3/4" RMC(UPS POWER)1-CAT6 IN 3/4" RMC(ETHERNET/IP COMMUNICATIONS)JUNCTIONBOXCONDUIT FORUPS POWERCONDUIT FOR CAT61SCALE: NONESCALE: NONE32JUNCTION BOX