HomeMy WebLinkAbout01-28-19 City Commission Packet Materials - C9. Res 5010, Authorize CO 3 to the WRF Small Works Construction ProjectCommission Memorandum REPORT TO: Honorable Mayor and City Commission FROM: Brian Heaston, Senior Engineer Shawn Kohtz, Interim Director of Public Works SUBJECT: Resolution 5010 Authorizing Change Order No. 3 to the WRF Small Works Construction Project MEETING DATE: January 28, 2019 AGENDA ITEM TYPE: Consent RECOMMENDATION: Approve Resolution 5010 authorizing Change Order No. 3 to the WRF Small Works Construction Project. BACKGROUND: Attached is Resolution 5010 and Change Order No. 3 for the above referenced project. The change order modifies the construction contract by adding in new work to install a new condensing boiler on the WRF heat loop. The new condensing boiler is necessary to provide additional heating capacity for the WRF heat loop system now that the WRF is operating at 100% digester capacity with the successful rehabilitation of digester number 1 and digester number 2. Heat calculations for the WRF indicate that the existing heat loop capacity is shy of meeting the full heat load of the plant with all three digesters running. Adequate heat capacity is imperative to ensure the proper and continuous operation of all three anaerobic digesters at the WRF during periods of extended cold weather. Should an extended cold snap be experienced under current heat loop capacity, the plant would be short of heat thus requiring at least one digester to be pulled out of service. Restarting digestion can be a finicky process and is not recommended. An opportunity exists to modify the WRF Small Works Project construction contract via change order to add the new boiler installation to the construction contract. The work will be completed by Williams Brother Construction, a qualified contractor currently bonded and insured to perform construction work for the WRF. The boiler addition is designed by HDR Engineering, who will also oversee construction to ensure compliance with plans and specifications. The approved FY19 budget includes a CIP project for the wastewater fund at $250,000 for the boiler addition (Project WW89 - ‘Heat Loop Optimization’. Change Order No. 3 increases the contract price by $147,400.00 and extends contract time to July 1, 2019 for substantial completion. 76 FISCAL EFFECTS: The FY19 wastewater fund CIP includes project WW89 – Heat Loop Optimization, which is allocated $250,000. Change Order No. 3 amends the contract price for the WRF Small Works Construction project to $1,192,874.63. Sufficient capital funding exists in the WRF budget to cover the total amended contract price. ALTERNATIVES: As suggested by the Commission ATTACHMENTS: Resolution 5010 Change Order No. 3 77 COMMISSION RESOLUTION NO. 5010 A RESOLUTION OF THE CITY COMMISSION OF THE CITY OF BOZEMAN, MONTANA, APPROVING ALTERATION/MODIFICATION OF CONTRACT WITH WILLIAMS BROTHER CONSTRUCTION, LLC, SPOKANE, WASHINGTON WHEREAS, The City Commission did, on the August 28, 2017, authorize award of the bid for the WRF Small Works Construction Project to Williams Brother Construction, LLC, Spokane, Washington; and WHEREAS, Section 7-5-4308, Montana Code Annotated, provides that any such alterations or modifications of the specifications and/or plans of the contract be made by resolution; and WHEREAS, it has become necessary in the prosecution of the work to make alterations or modifications to the specifications and/or plans of the contract. NOW, THEREFORE, BE IT RESOLVED by the City Commission of the City of Bozeman, Montana, that the proposed modifications and/or alterations to the contract between the City of Bozeman, a municipal corporation, and Williams Brother Construction, LLC, as contained in Change Order No. 3, attached hereto, be and the same are hereby approved; and the City Manager is hereby authorized and directed to execute the contract change order for and on behalf of the City; and the City Clerk is authorized and directed to attest such signature. 78 PASSED, ADOPTED, AND APPROVED by the City Commission of the City of Bozeman, Montana, at a regular session thereof held on the 28th day of January, 2019. ___________________________________ CYNTHIA L. ANDRUS Mayor ATTEST: _____________________________________ ROBIN CROUGH City Clerk APPROVED AS TO FORM: ___________________________________ GREG SULLIVAN City Attorney 79 80 hdrinc.com 700 SW Higgins AvenueSuite 200Missoula, MT 59803‐1489 (406) 532‐2200 January 22, 209 Dear Barry, The CPR No. 10 documentation is modified as follows. Signing of this Change Order No. 3 indicates and understanding and compliance with these changes and is outlined in your attached quote. Included all labor and equipment to furnish and install the boiler and appurtenances:  ClearFire CFC‐CE 2000MBH Boiler,  Taco VR25‐3 Pump  Taco Model ACUF‐400‐AF 4" Balancing Valve  Two position actuator with 24 V actuator to Combustion Air intake at the collar on the boiler  Header Sensor Kit to the boiler  Thermometer on the boiler inlet and the boiler outlet piping coming to and from the main  Concrete pedestal for the boiler  Discharge flue can be 8” diameter  Natural gas regulator for 8 psi to 14” WC is included Hydroiron quote, though not specifically mentioned.  Boiler emergency shutdown tied into emergency button at exit. Sincerely, HDR Engineering Coralynn L. Revis, PE Project Manager 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 Bulletin 71.1:CS800 November 2014 D103140X012 www.fisherregulators.com Figure 1. Typical CS800 Series Pressure Reducing Regulator Features and Benefi ts • Flow-optimized disks provide the maximum fl ow for your application • Largest number of overpressure protection offerings in the industry • Wide variety of body sizes and end connections • Body materials available in gray cast iron, ductile iron and steel • Fixed Factor/Pressure Factor Measurement (PFM) accuracy capabilities • Only standard tools required for pressure adjustment and orifi ce removal • Simplifi ed maintenance CS800 Series Commercial/Industrial Pressure Reducing Regulators TyPE CS800 REGuLATOR P1235 P1521 TyPE CS803 REGuLATOR WITH TRuE-MOnITOR ™ PROTECTIOn P1234 TyPE CS800IQ WITH HIGH CAPACITy RELIEF P1692 TyPE CS804IT REGuLATOR WITH InTEGRAL TyPE VSX8 SLAM-SHuT MODuLE 96 97 98 99 100 101 102