Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Blackmore Bend Market Place
STREET OWNER / DEVELOPERLEGAL DESCRIPTIONDESIGN CRITERIAOCCUPANCY TYPES:'M', 'B' (SEE CODE INFO. SHEET)OCCUPANCY SEPARATION: NONE (SEE CODE INFO. SHEET)TYPE OF CONSTRUCTION: V-B (SEE CODE INFO. SHEET)BUILDING HEIGHT:40'-0"NO. OF STORIES:2-STORIESAUTOMATIC SPRINKLERS: YES, PER NFPA 13FROST DEPTH: 48 INCHESBASIC GROUND SNOW LOAD: 41 PSFDESIGN WIND SPEED: 90 MPH, EXPOSURE 'C'SEISMIC DESIGN CATEGORY: 'D'CURRENT ZONING: B-2GROSS SQ. FT. 23,354 FIRST LEVEL 3,096 MEZZANINE15,320 SECOND LEVEL41,770 TOTAL GROSS SQ. FT.DRAWING INDEXABBREVIATIONSPROJECT INFORMATIONCopyright © 2017 Springer Group Architects, P.C.CONSULTANTS:GRAVELMASONRYMETALCONCRETEEARTHBATT INSULATIONRIGID INSULATIONFINISH WOODACOUSTIC TILEROUGH WOODMATERIAL SYMBOLSVICINITY MAPGENERAL NOTESTHE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE FIELD MEASUREMENTS PRIOR TO ORDERING MATERIALS & PRE-FABRICATINGITEMS. ANY NECESSARY ADJUSTMENTS IN FIELD MEASUREMENTS AND/OR BETWEEN FIELD MEASUREMENTS AND DRAWINGS SHALL BE MADE IN ACCORDANCE WITH THE DECISION OF THE ARCHITECT AND OWNER.CONTRACTOR SHALL PROVIDE BACKING/BLOCKING AS REQUIRED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC.CONTRACTOR IS TO SUPPLY AND INSTALL A 4'-0" x 8'-0" BUILDING CONSTRUCTION SIGN WHICH STATES THE FOLLOWING:GENERAL CONTRACTOR OWNER / DEVELOPERADDRESS & PHONEADDRESS & PHONEARCHITECTDEVELOPMENT NAMEADDRESS & NAMEADDRESS & NAMEALL PARTITION DIMENSIONS ARE TO FACE OF FRAMING OR TO CENTER-LINE OF PARTITIONS, STRUCTURAL COLUMNS, AND BEAMS U.N.O.ALL COMBUSTIBLE MATERIALS TO BE MINIMUM OF 1" CLEAR OF ALL HEAT TRANSFERING VENT STACKS. APPROVED FLASHING TO BE INSTALLED AT ALL CHIMNEYS, WALL-TO-ROOF INTERSECTIONS, AROUND ALL ROOF PENETRATIONS, AND ABOVEALL EXTERIOR DOOR AND WINDOW OPENINGS.EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AND ROOF ANDBETWEEN WALLS AND PANELS. OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOOR, AND ROOFS, AND ALL OTHERSUCH OPENINGS INTO THE BUILDING ENVELOPE, INCLUDING ACCESS PANELS INTO UNHEATED SPACES SHALL BE SEALED, CAULKED, GASKETED, OR WEATHERSTRIPPED TO LIMIT AIR LEAKAGE. ALL EXTERIOR DOORS SHALL BE DESIGNED TO LIMIT AIR LEAKAGE AROUND THEIR PERIMETER WHEN IN THE CLOSED POSITION.PROVIDE GYPSUM WALLBOARD OF TYPE AND THICKNESS INDICATED ON DRAWINGS. GYPSUM BOARD WORK AND MATERIALS SHALL MEET ALLREQUIREMENTS OF ANSI NO. A 97-1 FOR THE "APPLICATION AND FINISHING OF WALLBOARD" JOINT COMPOUND SYSTEM MIXED, APPLIED ANDFINISHED IN COMPLIANCE WITH MANUFACTURERS PRINTED DIRECTIONS. JOINTS TO BE INVISIBLE AFTER FINISHED, INCLUDING ALL METAL CORNER BEADS AND TRIM.@-AT# - POUND(S) OR NUMBER+/- - PLUS MINUSAFF-ABOVE FINISH FLOORAC-ACOUSTICAL ACT-ACOUSTICAL CEILING TILEADJ-ADJACENTA/C-AIR CONDITIONINGALT-ALTERNATIVEALUM.-ALUMINUMALT-ALTERNATIVEALUM.-ALUMINUMA.B.-ANCHOR BOLTAPPD-APPROVEDAPPROX. -APPROXIMATEARCH-ARCHITECT(URAL)BSMT- BASEMENTBM.- BEAMBRG- BEARINGBLKG- BLOCKINGBD- BOARDBOT- BOTTOMBLDG- BUILDINGB.U.R.- BUILT UP ROOFINGCAB- CABINETCLG- CEILINGC\C OR C.C. - CENTER TO CENTERCL OR C.L. - CENTERLINECT - CERAMIC TILECLR - CLEARC.W. - COLD WATERCOL - COLUMNCF OR C.F. - COMMUNICATION FEATURESCOMP. - COMPACT(ED)CONC - CONCRETECMU - CONCRETE MASONRY UNITCONST - CONSTRUCTIONCJ OR C.J. - CONTROL JOINTCONT. - CONTINUOUSCORR. - CORRIDORDTL. - DETAILDEPT. - DEPARTMENTDIA. - DIAMETERDIV. - DIVISIONDBL. - DOUBLEDN - DOWNDS - DOWNSPOUTDWG - DRAWINGD.F. - DRINKING FOUNTAINEA - EACHE.W. - EACH WAYEF - EACH FACEELEC - ELECTRIC(AL)EWC OR E.W.C. - ELECTRIC WATER COOLEREL. - ELEVATIONELEV. - ELEVATOREMER. OR EMERG. - EMERGENCYENCL. - ENCLOSUREENG. - ENGINEEREQ - EQUALEQUIP. - EQUIPMENTEXG - EXISTINGEXP - EXPOSEDEJ OR EJ. OR E.J. - EXPANSION JOINTEXT - EXTERIORF.R.P. - FIBER REINFORCED PLASTICFF - FINISH FLOORFIN - FINISH(ED)FBO- FINISH BY OTHERSF.A.- FIRE ALARMFC- FIRE CODEF.E.- FIRE EXTINQUISHERF.E.C.- FIRE EXTINQUISHER CABINETFP- FIREPROOFF.R.- FIRE RESISTANTFLR- FLOORFD OR F.D. - FLOOR DRAINFLUOR. - FLUORESCENTFT- FOOT (FEET)FTG- FOOTING FDN.- FOUNDATIONFRM.- FRAMEGA- GAGE, GAUGEGALV.- GALVANIZEDGC- GENERAL CONTRACTORGL.- GLASS/GLAZINGGYP. BD.- - GYPSUM BOARD HDWR. - HARDWAREHVAC- HEATING/VENT./AIR COND.HADG- HILTON ACCESSIBILITY DESIGNHC- HOLLOW COREHM- HOLOW METALHORIZ. - HORIZONTALH.B.- HOSE BIBH.W.- HOT WATERHR- HOURIN.- INCH(ES)INCL- INCLUDE(ING)INSUL- INSULATE(ION)INT- INTERIORINV.- INVERTJAN.- JANITOR(IAL)JT- JOINTKIT.- KITCHENK.O.- KNOCKOUTLAM- LAMINATELAV.- LAVATORYLT. WT. - LIGHT WEIGHTLL- LIVE LOADLB. OR LBS. - POUND(S)MFR- MANUFACTURERM.H.- MAN HOLEMAS- MASONRYM.O.- MASONRY OPENINGMAX- MAXIMUMMECH- MECHANICALMED.- MEDIUMMTL- METALMM- MILLIMETERMIN- MINIMUMMISC.- MISCELLANEOUSMR OR M.R. - MOISTURE RESISTANTMTD.- MOUNTEDNAT- NATURALNR- NOISE REDUCTIONNOM- NOMINALNO- NUMBERNIC- NOT IN CONTRACTNTS- NOT TO SCALEOC- ON CENTEROPG- OPENINGOD- OUTSIDE DIAMETEROH- OVERHANGPNL- PANELPBD- PARTICLE BOARDPVMT- PAVEMENTPLF- PER LINEAR FOOTPL- PLATEPLWD- PLYWOODPVC- POLYVINYL CHLORIDEPSF- POUND PER SQ. FOOTPSI- POUND PER SQ. INCHPLBG.- PLUMBINGP.T.- PRESSURE TREATEDRAD- RADIUSREF- REFERENCEREINF- REINFORCE(D)R.A.- RETURN AIRREQ'D - REQUIREDR-RISERRFG- ROOFINGRO OR R.O. - ROUGH OPENINGRD. OR R.D. - ROOF DRAINSHT- SHEETSIM- SIMILARSC- SOLID CORESPK- SPEAKERSPEC- SPECIFICATIONSQ- SQUARESTR- STRUCTURE(AL)SS- STAINLESS STEELST.- STREETSTD.- STANDARDSTL.- STEELSTOR. - STORAGESUSP.- SUSPENDEDSYS- SYSTEMTEL.- TELEPHONETV OR T.V. - TELEVISIONTEMP. - TEMPORARY OR TEMPEREDTHK- THICK(NESS)T&G- TONGUE & GROOVET&B- TOP & BOTTOMT-TREADTS OR T.S. - TUBE STEELTYP.- TYPICALU.N.O. - UNLESS NOTED OTHERWISEVERT.- VERTICALVIF OR V.I.F. - VERIFY IN FIELDVCT- VINYL COMPOSITION TILEVB- VINYL BASEWSCT. - WAINSCOTWC- WATER CLOSETWP- WATERPROOF(ING)W.V.- WATER VALVEWT.- WEIGHTWWF OR W.W.F. - WELDED WIRE FABRICWWM OR W.W.M. - WELDED WIRE MESHW.F.- WIDE FLANGEW- WIDE, WIDTHW/- WITHW/O- WITHOUTWD- WOODWIN- WINDOWPROJECT ACCESSIBILTY NOTES:THESE PLANS HAVE BEEN DESIGNED IN COMPLIANCE WITH ICC A117.1 AND THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. ADDITIONALACCESSIBILITY REQUIREMENTS MAY ALSO BE REQUIRED BY STATE OR LOCAL AUTHORITIES HAVING JURISDICTION (AHJ). THE TERM "ACCESSIBLE"WILL BE USED THROUGHOUT THESE PLANS TO REFER TO THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN WHICH ARE MANDATED FOR PLACES OF PUBLIC ACCOMMODATIONBY TITLE III REGULATIONS OF THE ADA AT 28 CFR PART 36, SUBPART D; AND MUST FOLLOW THE 2004 ADAAG AT 36 CFT PART 1191, APPENDICES B AND D. OWNER MUST ALSO ENSURE THAT THE FACILITY IS CONSTRUCTED AND MAINTAINED IN COMPLIANCEWITH THE ADA STANDARDS.ADOPTED BUILDING CODESTHE FOLLOWING ARE BUILDING CODES THAT HAVE BEEN ADOPTED BY THE CITY OF BOZEMAN:- INTERNATIONAL BUILDING CODE, 2012 EDITION- INTERNATIONAL ENERGY CONSERVATION CODE, 2012 EDITION- INTERNATIONAL EXISTING BUILDING CODE, 2012 EDITION- INTERNATIONAL FUEL GAS CODE, 2012 EDITION- INTERNATIONAL MECHANICAL CODE, 2012 EDITION- INTERNATIONAL RESIDENTIAL CODE, 2012 EDITION- NATIONAL ELECTRICAL CODE, 2014 EDITION- UNIFORM PLUMBING CODE, 2012 EDITIONTHE BUILDER ACKNOWLEDGES THESE CODES ARE APPLICABLE TO ALL SHEETS, NOTES AND TABLES IN THESE PLANSAND ASSURES THE LOCAL JURISDICTION HE OR SHE WILL COMPLY WITH ALL CURRENT AND LOCAL CODES.CONSTRUCTION ROUTE MAP10/5/2017 1:19:44 PM15-004ABLACKMORE MARKETPLACE BUILDINGEast Main Investments, LLC1324 E. Main St., Bozeman Montana6-6-2017G000COVER SHEETBLACKMOREMARKETPLACE BUILDING1324 E. Main St., Bozeman MontanaS801 BASE PLATESMECHANICALM-001 HVAC COVER SHEETM-002 HVAC NOTESM-003 HVAC NOTESM-101 FIRST LEVEL HVAC FLOOR PLANM-102 MEZZANINE LEVEL HVAC FLOOR PLANM-103 SECOND LEVEL HVAC FLOOR PLANM-104 ROOF HVAC PLANM-401 ENLARGED HVAC PLANSM-402 ENLARGED HVAC PLANSM-501 HVAC DETAILSM-502 HVAC DETAILSM-503 HVAC DETAILSM-601 HVAC SCHEDULESM-602 HVAC SCHEDULESM-603 HVAC SCHEDULESM-604 HVAC SCHEDULESM-605 HVAC SCHEDULESM-606 HVAC SCHEDULESM-607 HVAC SCHEDULESM-608 HVAC SCHEDULESM-609 HVAC SCHEDULESM-610 HVAC SCHEDULESPLUMBINGP-001 PLUMBING COVER SHEETP-002 PLUMBING NOTESP-003 PLUMBING NOTESP-101A FIRST LEVEL PLUMBING FLOOR PLAN -DRAIN, WASTE & VENTP-101B FIRST LEVEL PLUMBING FLOOR PLAN -DOMESTIC WATERP-102A MEZZANINE LEVEL PLUMBING FLOORPLAN - DRAIN, WASTE & VENTP-102B MEZZANINE LEVEL PLUMBING FLOORPLAN - DOMESTIC WATERP-103A SECOND LEVEL PLUMBING FLOOR PLAN -DRAIN, WASTE & VENTP-103B SECOND LEVEL PLUMBING FLOOR PLAN -DOMESTIC WATERP-104 ROOF PLUMBING PLANP-401 ENLARGED PLUMBING FLOOR PLANSP-402 ENLARGED PLUMBING FLOOR PLANSP-403 ENLARGED PLUMBING FLOOR PLANSP-501 PLUMBING DETAILSP-502 PLUMBING DETAILSP-601 PLUMBING SCHEDULESP-602 PLUMBING SCHEDULESP-603 PLUMBING SCHEDULESP-604 PLUMBING SCHEDULESELECTRICALEE001 SHEET INDEX, ABBREVIATIONS, &GENERAL NOTESEE002 SYMBOLS LEGENDEE701 TYPICAL MOUNTING HEIGHT DETAILSEL101 LEVEL 1 LIGHTING PLANEL102 MEZZANINE & LEVEL 2 LIGHTING PLANEL601 LIGHTING FIXTURE SCHEDULEEP101 FIRST LEVEL POWER PLANEP102 MEZZANINE LEVEL POWER PLANSEP103 ROOF LEVEL POWER PLANEP401 ENLARGED POWER PLANSEP402 ENLARGED POWER PLANSEP403 ENLARGED POWER PLANSEP601 ONE-LINE DIAGRAMEP602 MECHANICAL EQUIPMENT SCHEDULEEP603 REFRIGERATED CASE SCHEDULEEP604 GROCERY EQUIPMENT SCHEDULEEP605 PANEL SCHEDULESEP606 PANEL SCHEDULESES101 ELECTRICAL SITE PLANES102 PHOTOMETRIC SITE PLANET101 LEVEL 1 TELECOMUNICATICATIONSFLOOR PLANET102 MEZZANINE & LEVEL 2 DATA PLANEY101 LEVEL 1 ACCESS CONTROL PLANEY102 MEZZANINE & LEVEL 2 ACCESS CONTROLPLANEY601 ACCESS CONTROL DETAILSREFRIGERATIONR1 FIXTURE FLOOR PLANR2 PLUMBING FLOOR PLANR3A FIXTURE FLOOR PLANR3B PLUMBING FLOOR PLANR3C REFRIGERATION FLOOR PLANR4 ELECTRICAL FLOOR PLANR5 ROOF PLANR6A REFRIGERATION SCHEDULER6B REFRIGERATION SCHEDULER6C CPC BOARDS & BUSSBARSR7 WIRING SCHEMATICSR8A CASE DETAILSR8B CASE DETAILSR9 CASE DETAILSR10 EQUIPMENT DETAILSGENERALG000 COVER SHEETG001 PROJECT & CODE INFORMATIONG002 CODE INFORMATION & ASSEMBLIESG010 RESPONSIBILITY MATRIXG011 RESPONSIBILITY MATRIXCIVILC001 LEGEND AND GENERAL NOTESC101 EXISTING CONDITIONSC102 SITE PLANC201 GRADING PLANC202 GRADING DETAILSC203 EROSION CONTROLC301 SANITARY SEWER PLAN AND PROFILEC302 WATER PLAN AND PROFILEC303 WATER PLAN AND PROFILEC304STORM DRAIN PLAN AND PROFILEC305 STORM DRAIN PLAN AND PROFILEC401 DETAILSC402 PAVING PLANLANDSCAPEL100 LANDSCAPING PLANARCHITECTURALA000 INSTALLATION STANDARDSA100 SITE PLANA101 SITE DETAILSA102 SITE DETAILSA103 SITE DETAILSA104 SITE DETAILSA200 FIRST LEVEL FLOOR PLANA201 MEZZANINE LEVEL FLOOR PLANA202 SECOND LEVEL FLOOR PLANA203 ROOF PLANA250 FIRST LEVEL REFLECTED CEILING PLANA251 MEZZANINE LEVEL REFLECTED CEILINGPLANA252 SECOND LEVEL REFLECTED CEILINGPLANA300 EXTERIOR ELEVATIONSA301 EXTERIOR ELEVATIONSA302 EXTERIOR PERSPECTIVESA400 BUILDING SECTIONSA401 BUILDING SECTIONSA402 BUILDING SECTIONSA450 WALL SECTIONSA451 WALL SECTIONSA452 WALL SECTIONA453 WALL SECTIONSA454 WALL SECTIONSA455 WALL SECTIONSA500 ENLARGED FLOOR PLANSA501 ENLARGED FLOOR PLANSA502 ENLARGED FLOOR PLANA503 ENLARGED FLOOR PLANSA550 INTERIOR ELEVATIONSA551 INTERIOR ELEVATIONSA600 EXTERIOR DETAILSA601 EXTERIOR DETAILSA602 EXTERIOR DETAILSA603 EXTERIOR DETAILSA650 INTERIOR DETAILSA700 DOOR SCHEDULES & DETAILSA701 STOREFRONT SYSTEMSA702 STOREFRONT SYSTEM DETAILSA703 WINDOW SCHEDULE & DETAILSA704 ROOM FINISH SCHEDULEAGGREGATE PIERSG1.00 AGGEGATE PIER PLANG2.00 PIER DETAILS AND SPECIFICATIONSSTRUCTURALS001 STRUCTURAL COVER SHEETS002 GENERAL NOTESS003 SCHEDULESS100 FOUNDATION PLANS101 STRUCTURAL LOADING PLANS200 FIRST LEVEL FRAMING PLANS201 MEZZANINE LEVEL FRAMING PLANS202 SECOND LEVEL FRAMING PLANS203 ROOF FRAMING PLANS301 FRAMING ELEVATIONSS302 FRAMING ELEVATIONSS303 FRAMING ELEVATIONSS401 FOUNDATION DETAILSS402 FOUNDATION DETAILSS403 FOUNDATION DETAILSS501 FRAMING DETAILSS502 FRAMING DETAILSS503 FRAMING DETAILSS504 FRAMING DETAILSS601 TYPICAL DETAILSS602 TYPICAL DETAILSS603 TYPICAL DETAILSS701 ENLARGED PLANSS702 ENLARGED PLANSTRACT 1 (H-29), TRACT 5C & 5D (H-29-D), TRACT 5 REMAINDER (H-29) PART OF THE REARRANGEMENTOF ELKS CLUB PROPERTY SUBDIVISION LOCATED IN THE SOUTHWEST 1/4 SECTION 8, TOWNSHIP 2 SOUTH,RANGE 6 EAST, PRINCIPAL MERIDIAN MONTANA, CITY OFBOZEMAN, GALLATIN COUNTY, MONTANA1184 N. 15th Ave., Suite 4, Bozeman, MT 59715Phone: (406) 624-0382Email: dcape@jwtcompanies.comPROJECT LOCATIONCIVIL:KLJ ENGINEERS1982 STADIUM DRIVE, SUITE 3BOZEMAN, MT 59715-0697406.404.1849STRUCTURAL: HYALITE ENGINEERS, PLLC.50 BRONCO DRIVEBOZEMAN, MT 59715406-587-2781MECH./ELEC:SPECTRUM ENGINEERS324 SOUTH STATE, SUITE 400SALT LAKE CITY, UT 84111801-328-5151LANDSCAPE:CUSTOM EARTH DESIGNS3337 N. 27TH #31BOZEMAN, MT 59718406.539.7030PROJECT LOCATIONCONSTRUCTIONTRAFFIC....CONSTRUCTIONTRAFFIC.CONSTRUCTIONTRAFFIC..O-S Leasing Partners, LLP203 Haggerty Ln.Bozeman, MT 59715-9235Phone: 406-595-1250Email: ric@jhoe.comTHE BLACKMORE MARKETPLACE (HEEB'S) PROJECT DESIGN DOCUMENTS WERE FUNDED IN PART, BY AN AWARD FROM THE MONTANA DEPARTMENT OF COMMERCE, BIG SKY ECONOMICDEVELOPMENT TRUST FUND PROGRAM.AS BUILT DRAWINGS HAGGERTY LANE SHEETMADISON ENGINEERING 895 TECHNOLOGY BLVD, SUITE 203 BOZEMAN, MT 59718 (406) 586-0262 (406) 586-5740 FAXOFBLACKMORE MRKTSTORM DRAINBLACKMORE MARKETPLACE STORM DRAIN REVISION 1 BOZEMAN, MT 1 inch =0SCALE10 feet20'5' 10'STORM DRAIN REVISION 1AS BUILTC306 9' 10'STORM DRAINDUMPSTERPADWATER MAIN?????????????????????????????????????????????????????????9' 10'STORM DRAINDUMPSTERPADWATER MAINMARKETPLACE BLDGF.F.=4824.751 inch =0SCALE20 feet40'10' 20'FIRE SERVICE LINE EXT. PLANFIRE SERVICE LINE PROFILEDATUMNAVD 88C4.0FIRE SVCSHEETMADISON ENGINEERING 895 TECHNOLOGY BLVD. STE. 203 BOZEMAN, MT 59718 (406) 586-0262 (406) 586-5740 FAX BLACKMORE BEND MARKETPLACE FIRE LINE PLAN & PROFILE BOZEMAN, MTFIRE LINEDETAIL1C4.06" FIRE SERVICE RISERDETAIL3C4.0TYPICAL UTILITY TRENCH DETAILDETAIL2C4.0THRUST BLOCKING FITTINGSAS BUILT