HomeMy WebLinkAboutSidewinders Fireline LEGEND �1 OF ro, w .In- Ati=--r- k�maw � d PROPERTY BOUNDARY LINE w wm< !ro6rs- a -X LEGEND MARK A. EASEMENT LINE no ^$FLANGED OS&Y VALVE CH _ - 1 - - - - - - - - - - - 4820- - - 11Ew1.5'SEBV - - - - - - - - � No. 9518ES e"w EXISTING 8'WATER MAIN �rrpw '' "r j DOUBLE CHECK VALVE oy9 NE•GI SiF•R�� p J I '° ' ' MIN.REQUIREMENT) ! >w EXISTING 4"WATER LINE 4' n LARGER CLASS 51 J_ AS INDICATED ON I11EER DlIC11lE IRON PIPE(ttP.) s Mac Aeac - ABANDON EXISTING 1'COPPER ER SERVIC w EXISTING WATER SERVICE ^�^aa APPROVED PLANS) IN PLACE,REMOVE CO ORATION STOP INSTALL NEW 1.5"TYPE K COPPER WATER ...i.`.',..''.: AND P G SERVICE TAP SE w PROPOSED WATER SERVICE •• +a - " ' „w 0+00 Sheet 1 a"w a"w °.a" e"w s" s"w s"w s"w s"w "w s"w n'- a'ss PROPOSED 4"SEWER SERVICE MECHNIICAL 3/4"MIN. (T Rod,INSTALLED IN EVERY OTHER AVAILABLE M.J. a w Ce of 1 a"ss EXISTING 4"SEWER SERVICE JOINT BOLT HOLES(TYPMN_)-S/8'RODS ACCEPTABLE FOR 4'LINES BENCHMARK: MAIN SEWER MANHOLEM ucE PROPOSED UNDERGROUND ELECTRIC LINE 1 ELEV.=4820.9 D ) - - - C 80'BEND WITH THRUST BLOCK B L O K � U m�° d I 1 3 F - coNM PROPOSED COMMUNICATIONS LINE a82t I`m ED -_-_----- - - 4822 ,- r m cas PROPOSED GAS LINE RQUO$�T ^+" �a"ss s- a"ss - a"ss a"ss a"ss a"ss m PING TEE&VALVE, CITY OF BOZE REQUIREMENTS CDR INSTAULATON OF 5 8"55 8" a"55 8"55 - --_ - e' a"ss o e"ss EXISTING 8"SANITARY SEWER MAIN DOUBLE CHECK VALVE ASSEMBLY - OR INSTALL VALVE AT PROPOSED E a sr PROPOSED STORM SEWER PROPERTY UNE(TYPICAL REMOVE IXISTING CAP AND BLOWOFF AND CONNECT 3 SEWER 7 $B a FOR ALL RISER CONFIGURATIONS) 1. The FIRST fitting indds of Me boding gNEW 4"DIP TO EXISTING GATE VALVE. FIELD VERIFY �� SERVICE f PROPOSED 4-FIRE SERVICE Kennedy or Mueller 1 valve the shall bee UL lee Ran ea EXISTING SEWERtB 4823 s -0 •In same size ae the firo service line. ___--�L€YATlON--9ND LOCATION STUB. \- __ ----- ��� INSTALL NEW CURB STOP WITH NEW _ PROPOSED CURB AND GUTTER ® 2. All Double Check Vahe Meembliea shall be: 1.5 WA R SERVICE.ADJUST TO - 9 . UL or FM hated. - - - - - - - - - - - - - - - - - - - - - - - - p b. Mpproved by the Univeroity of Soutb-Califomia Foundation for �IRISFIE6("Rl@E. a ® EXISTING CURB STOP cross Conn«tnn Control and Hydraulic Reeearon(USCF)CCHR)for EXISTING UTILITY to m m PROVIDE FLEXIBLE. 7 the ed b Mool«horizontal ae shown on - EASEMENT TYP. C a m operation, propoe pne"on(ve ) L `v ® PROPOSED CURB STOP WATER TIGHT CONNECTION approved plane. "p❑'`- © FOR ALLJE OR o. Inelolled ae enown on the approved plane. d 4 4823a d °� ° a O m JJ PROPOSED STORM SEWER MANHOLE PIPE PE3. A fl det ct'oa dov hall be installed' med'atsly fonowmq the a ° d 4 C mot EXISTING WATER VALVE Double Ch«k Valve Maemby(alarm h«k vanro.flow sensor/alarm, a mekr,etcJ shown on the approved plans.Paddle type flow alarms not 4 C `� ° C a a ° a a a ae a a d ° portniHed on dry systems. d 4B22 a d ° a. d: W EXISTING SANITARY SEWER MANHOLE 4 ------ _ 4 a 4. o Double Detector Ch«k Valve Aaeembl oy be tied Rh°etandard _ MWYF FLOOR Cityofzaman meter. Thamete loopofthe Double Detector Ch«kW ° 4Valve shall have a Double Ch«k ValveAssembly installed which eels M HANICALthe«me matmlaton cmena.p«IfiW abovein roRaroment namner two. d 5. Horizontal inetallatione muel na a minimum of z'above tna rnienae Z PROPOSED STORM S7A 0+70.3(0.0'L) RM )Efloor. Z SEWER 70 DRYWELL DETAIL 46. Thefiro service riser muet 6e a minimum of 2'from any outside wall,and a minimum of V from any Intmior wall. > STA 0+36.2(0.0'R) BENCHMARK 'e 7. The ina°ming Rre service line.hall be a minimum 6.5%and o ma.- ae 4"90'BEND 911Oimam of 7.5'belowefinlhed grade.RIM OF EXISTING MANHOLE D WITH e. Allfiroervice line app.,Ienonoe.shall have a mmimum preeeuro NORTHWEST OF SITE BLOCK rating of 175 PSI. \/ ELEV.=4,820.39 FEET DATUM:(NAVD88) 9. Al firo sevme lines 4'and layer shall be Claee 51 Duc61e Iron Pipe. 10.Un iziW: The D°able Check Valve Aeeembb,shall be equal in elze O to both Nei ming pipe diameter(upstream)a d odgoing pipe diameter LEGAL DESCRIPTION (°°"""roam). I rTl �l'MIN.,2'MAX. L LINE T OS&Y VALVE CE FFE= MfNT20 U LOT 3,BLOCK 1,PLAT J-563 - Q (BASEMFvNT) U THE FERGUSON FARM SUBDIVISION PER NPPA-24 FIG A.10.6.3.1 LOCATED IN SW 1/4,OF SECTION 10, T.2 S.,R.5 E.OF P.M.M.,CITY OF BOZEMAN, GALLAnN COUNTY,MONTANA t 2'MIN.,3'MAX CLEARANCE Q Ell" ABOVE flNISHED FLOOR O W RESTRAIN ALL JOINTS WITHIN SPECIFIED LENGTH FROM FITTING M SIDEWINDERS RESTAURANT con W FFE=4824.20(MAIN FLOOR) Tyl FITTING LENGTH(FT) NOTE ° 110 UP 90 BEND 9 CITY OF BOZEMAN SCALE: STANDARDLINE NSTIALLATIONRE ICE NO. 02660-13 8X4 TEE 10(BRANCH) RUNJOINTS WITHIN 4'ON NONE DEC 2003 STANDARD DRAWING FOR CLASS I, II, & III SYSTEMS REV: AP \ ° I� 1 FIRE SERVICE DETAIL a �J' , GENERAL NOTES - FIRE SERVICE LINES F1.o SCALE:TITS - - - - - - = - - - - ^ 0 1. ALL CONSTRUCTION SHALL CONFORM TO THE ACCOMPANYING PLANS AND SPECIFICATIONS. UP 2. NO CHANGE OR MODIFICATION OF THE APPROVED PLANS AND SPECIFICATIONS 4821 - -- - SHALL BE MADE WITHOUT THE PRIOR WRITTEN APPROVAL OF THE ENGINEER AND THE CITY OF BOZEMAN ENGINEERING DEPARTMENT. --- --4822 -- I � A 3. PRIOR TO THE AND THE CITY OF MEETING,THE CONTRACTOR SHALL SUBMIT TO FIRST ----- THE ENGINEER AND THE CITY OF BOZEMAN,WORKING DRAWINGS,SPECIFICATION FIRST FLOOR - _ ------ SHEETS,ETC.,FOR ALL EQUIPMENT AND MATERIALS TO BE USED ON THE -_----- PROJECT.INSTALLATION SHALL NOT BE MADE WITHOUT THE PRIOR WRITTEN F c u -----croNM- Comm Comm Comm APPROVAL OF ALL EQUIPMENT AND MATERIALS BY THE ENGINEER. (APPLIES TO ---------- uGE ucc ucc ucc i82.s._!�E ucc ucc 'w PUBLIC SEWER/WATER MAINS AND STREET IMPROVEMENTS ONLY.) 482 °° \ AC E 482` V1 ' 4. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL BURIED UTILITIES PRIOR PROPOSED GRADE d 4822 TO THE BEGINNING OF CONSTRUCTION. - 5. THE ENGINEER AND THE CITY OF BOZEMAN SHALL BE NOTIFIED AT LEAST 24 HOURS PRIOR TO BEGINNING CONSTRUCTION. 6. TRENCH BACKFILL SHALL BE TYPE A,FOR ALL AREAS TO BE PAVED. 7. ACCORDING TO CITY OF BOZEMAN REQUIREMENTS,APPROVED DOUBLE CHECK L� Fil BACKFLOW PREVENTION DEVICE MUST BE INSTALLED BY THE OWNER FOR THE r \ �l 3 FIRE SERVICE PLAN ` NEW BUILDING(S)SHOWN IN ACCORDANCE WITH COB DRAWING NO.2660-13. Ql p z 8. FIRE LINE INSTALLATION SHALL CONFORM WITH THE REQUIREMENTS OF THE CITY I \ LO' S`O F7.0 SCALE:1'=10' /'1 �01 OF BOZEMAN FIRE SERVICE LINE STANDARD. THE 4'FIRE SERVICE LINE 6`V p �04�0 `V71/L I! INCLUDING THE OS&Y VALVE ARE TO BE INSTALLED AS PART OF THIS PROJECT. I \ x � �0 1V 9. THE 4"FIRE SERVICE LINE IS TO BE PRESSURE TESTED AND CHLORINATED BY A 482 9 r'k _` SINGLE CONTRACTOR FROM THE POINT OF CONNECTION AT THE CITY WATER MAIN TO THE OS&Y VALVE IN THE BUILDING. Frl 10.APPLICATIONS FOR WATER SERVICES MUST BE MADE BY CONTRACTOR/OWNER h�l AND APPROVED BY Co.BEFORE THE FIRE SERVICE LINE AND DOMESTIC SERVICE LINE CAN BE INSTALLED. REMOVE AND BLOWOFFp��gTIN� GRADE 8. 11.THE 6.5'MINIMUM COVER OVER THE NEW FIRE LINE MUST BE IN PLACE,OR AND CONNE T NEW 4"DIP TO i SUFFICIENT INSULATION INSTALLED OVER THE LINES IF 6.5'OF COVER CAN NOT EXISTING GATE VALVE.FIELD 4"DIP FIRE LINE BE MAINTAINED,BEFORE THE LINE WILL BE ACTIVATED. VE ELEVATION AND TYPE K COPPER OCATION OF STUB. �0 WATER SERVICE 12.THIS PROJECT WILL BE CONSTRUCTED IN ACCORDANCE WITH"MONTANA PUBLIC INSTALL " FLANGED R DE A WORKS STANDARD SPECIFICATIONS, 6TH EDITION',MARCH 31 2011 (SECTION VALVE P R DETF 11(�-711 NUMBERS WITH MPW PREFIX),AND SUBSEQUENT AMENDMENTS,AND"CITY OF 1,THIS SHEET. Scale In Feet BOZEMAN MODIFICATIONS TO MONTANA PUBLIC WORKS STANDARD 1' IN.2'MAX CLR. 10 0 10 SPECIFICATIONS,5TH EDITION,MARCH 2O04." FROM WALL r 13.FIRE LINE IS A CLASS 1 SYSTEM. 4815 XISTING 4'DI 51 D r_ 3 0 3 1.5 (`=OTHERS MECHANICAL ROOM /N 14.FLUSHING ORIFICE TO BE AT LEAST 2"IN DIAMETER OR AS SPECIFIED BY FFE= 13.2 Scale In Meters h�l ENGINEER. 2'MIN BASEMENT Contour I'nter,als: 1 Foot 3' MAX 15.C&H ENGINEERING AND SURVEYING INC.WILL PERFORM INSPECTION WORK ON EXISTING 8" M THIS PROJECT WHICH IS SOLELY FOR ENSURING THAT THE PROJECT IS BUILT PER WATER MAIN THE APPROVED PLANS AND SPECIFICATIONS. THE CONTRACTOR IS SOLEY RESPONSIBLE FOR ENSURING THAT THE PROJECT MEETS ALL OSHA REQUIREMENTS AND THAT THE SITE MEETS ALL OSHA REQUIREMENTS AND ALL .4'CLEAR DISTANCE APPLICABLE SAFETY REQUIREMENTS BOTH FOR THEIR EMPLOYEES AND ANY SITE TO OS&Y VALVE INSPECTION WORK PERFORMED BY THE ENGINEER. SEE DETAIL 1 AND 2 THIS :EET FOR FIRE SERVICE DETAIL 0+ 11 Issue Date:41612017 a81 a MECHANICAL ROOM DETAIL wLL a F1.0 SCALE:1"=2' F 1■O 0+50 1+00 2 FIRE SERVICE PROFILE AS-BUILT F1.0 SCALE:HORIZONTAL 1'=20',VERTICAL 1"=2' 4/4/17 #16191