HomeMy WebLinkAboutSacajawea Middle School - Site Lighting Plan40' BUS40' BUS40' BUS40' BUS40' BUSDDCOBOLBOLBOLBOLBOLBOLLC1-25 LE3-1 3 LF1-1 P1(RELOCATED) P1(RELOCATED) P1(RELOCATED) P1(RELOCATED) P1 P3 P2 P2 P2 P2 P1 P1 P1P1 P3 P1(NEW) P1(RELOCATED) P1(RELOCATED) P2 P2 P2 P1(NEW) P3 P1(NEW) P3 LE3-13 NEW METER & LOAD CENTER NEW UTILITY TRANSFORMER DEWATER PUMP STATION HE1-13,15,17 DEWATER PUMP STATION CONTROLLER CONTROLS: (10) #10 CU, #10 CU GND IN 1"C POWER: (6) #12 CU, #12 CU GND IN 1"C FEED TO G-WING PANEL HANDHOLE 5FT LIGHT POLE OFF EOP 8FT 7FT CONDUIT OFF EOP 5FT 5FT CONDUIT OFF EOP LIGHT POLE OFF EOP 7FT CONDUIT OFF EOP 5FT 5FT CONDUIT OFF EOP LIGHT POLE OFF EOP 7FT CONDUIT OFF EOP 5FT LIGHT POLE OFF EOP OFFSET MEASUREMENT TAKEN OFF EDGE OF PAVEMENT (EOP). TYPICAL FOR EACH. KEY NOTES: 120/240V, 1PH, 3W PAD-MOUNT XFMR BY UTILITY M NEW METER PEDESTAL, SEE CITY OF BOZEMAN DETAIL TO LIGHTING(1) 2" C.O. project # revision date phase issue datesheet projectownerPHASE 2 5/11/2018 10:49:06 AM06-23-1764OVERALL SITE LIGHTING PLAN(2)E1.1 1552.054 5.09.18 AS-BUILT DRAWINGS3525 SOUTH 3RD RD, BOZEMAN, MT 59715SACAJAWEA MIDDLE SCHOOLBOZEMAN PUBLIC SCHOOLSAS-BUILT DRAWINGS 1" = 30'-0"1 OVERALL SITE LIGHTING PLAN NORTH 1 1 1 NOTES: 1.P1 - EXISTING 14' POLE & SINGLE HEAD TO REMAIN. P1(RELOCATED) - EXISTING 14' POLE & SINGLE HEAD, RELOCATE AS SHOWN. P1(NEW) - NEW 14' POLE & SINGLE HEAD. 2.COMPLY WITH CITY OF BOZEMAN ROADWAY LIGHTING SPECIFICATIONS. 2 2 SITE LIGHTING SCHEDULE MARK TYPE / DIMENSION LAMPS DIMMING EMERGENCY MOUNTING / HEIGHT VOLT MANUFACTURER SERIES / PART NO.Notes P1 EXTERIOR SITE / 14' POLE & 16" HEAD LED No No POLE / 16' AFG 120 V PHILIPS STONCO ELA16-1-3-110LA-NW-UNIV-BLP SEE NOTE 1 P2 EXTERIOR SITE / 22' POLE & 16" HEAD LED No No POLE / 24' AFG 120 V PHILIPS STONCO ELA16-1-3-110LA-NW-UNIV-BLP-HS P3 EXTERIOR STREET / 30' POLE & 40" HEAD LED No No POLE / 30' AFG 240 V PHILIPS LUMEC RX2-80-G2-A-2-3000K-A-5-RCD7-PHXL-D MG-N SEE NOTE 2 S. THIRD AVE. CONTRACTOR TO VERIFY LOCATION OF HOME-RUN FEEDING SITE LIGHTING. IF EXISTING UNDERGROUND HOME-RUN IS INTERRUPTED DURING SITE WORK, RE- FEED AS REQUIRED FOR A FULLY FUNCTIONAL SITE LIGHTING SYSTEM. RELOCATE LIGHT POLE; SEE CIVIL DRAWINGS FOR EXACT LOCATION. DEMO EXISTING BASE, CONDUIT, WIRE, ETC TO NEW SPLICE POINT/HAND HOLE LOCATION. RE-USE EXISTING POLE AND HEAD; PROVIDE NEW CONCRETE POLE BASE, CONDUIT, WIRE, ETC. SEE DETAIL 7/(2)E0.3. PROVIDE NEW FEEDER: 1" SCH. 40 PVC, (2) #8, #10 GND. INTERCEPT EXISTING CIRCUIT (VERIFY LOCATION IN FIELD); SPLICE IN NEW FEEDER AND EXTEND AS REQUIRED. PROVIDE HAND HOLE: POLYMER CONCRETE TIER 22 PULL BOX AND COVER. NOT USED. PROVIDE NEW FEEDER: 2" SCH. 80 PVC, (3) #10, #10 GND. SEE TRENCHING DETAIL, DETAIL 6, SHEET (2) E0.3. FIELD COORDINATE TRENCHING WITH EXISTING UNDERGROUND UTILITIES. SEE CITY OF BOZEMAN SPEC ("STANDARD SPECIFICATIONS FOR LIGHTING MATERIALS AND INSTALLATION") FOR POLE BASES. TIE IN NEW COURTYARD LIGHTING TO EXISTING CIRCUIT LE3-13 & ASSOCIATED TIMECLOCK. PROVIDE A 120/240V 1PH-3W, 200A, NEMA 3R, SE RATED 12-SPACE LOAD CENTER & METER HOUSING FOR CITY LIGHTING. SEE PANEL SCHEDULE ON THIS SHEET. SEE CITY OF BOZEMAN DETAIL & SPEC FOR FULL SERVICE METER / LOAD CENTER REQUIREMENTS. GROUND & BOND PER NEC. SEE DETAIL 2, THIS SHEET. COORDINATE NEW POWER SERVICE WITH NORTHWESTERN ENERGY. CONTACT DUSTIN WORKMAN, 406-582-4644. 3 4 4 3 3 3 3 3 3 3 3 3 3 3 4 5 6 6 6 6 3 3 3 3 4 2 2 2 1 COMPLETED IN PHASE I 2 2 PHASE 2 7 7 PHASE 2 8 8 9 9 Not To Scale2NEW SERVICE ELECTRICAL ONE-LINE