Loading...
HomeMy WebLinkAbout11-27-17 City Commission Packet Materials - A5. UDC Update ContinuedCommission Memorandum REPORT TO: Honorable Mayor and City Commission FROM: Tom Rogers, Senior Planner Martin Matsen, Director of Community Development SUBJECT: Unified Development Code (UDC) Update Public Hearing MEETING DATE: November 27, 2017 AGENDA ITEM TYPE: Action RECOMMENDED MOTION: N/A. RECOMMENDATION: Continue review of the draft revised Chapter 38 Unified Development Code. On August 24, 2017 the City Commission began consideration of the Unified Development Code (UDC) update, dated July 28, 2017. A motion to approve was made and seconded. A motion to table discussion was made and seconded. The Commission voted 2:2 on the motion to table. The excused Commissioner will consider and vote on the motion to table discussion on the revised development on Thursday, September 7, 2017. On September 7, 2017 the Commission voted not to table the discussion on the UDC, final vote 3:2. On September 11, 2017 the Commission continued consideration of the UDC update. The Commission completed review of Article 1 and began consideration of Article 2. The Commission continued the review to Monday, September 18, 2017. On September 18, 2017 the Commission continued the public hearing to October 2, 207. No action was taken at the September 18, 2017 hearing. On October 2, 2017 the Commission completed review of Article 2 and began consideration of Article 3. Two motions were made to amend the development code. Staff is maintaining a summary of all motions to track what changes will be made. The Commission continued the public hearing to October 23, 2017 with intention to focus on Articles 3 and 4. Staff held a meeting on Wednesday, October 4, 2017 with a group of design community to discuss and improve the minimum design standards in Article 5. The discussions with the design community are ongoing. On October 16, 2017 the Commission continued their review of the draft development code. Staff presented numerous illustrations describing the current and proposed zone edge transitions requirements and illustrations covering floor area ratios (FAR). No motions were made at this hearing. Review will continue with Article 3. On October 23, 2017 the Commission continued their review of the draft development code. Staff completed presenting Article 3. The Commission continued their discussion and focused on zone edge transitions, zoning authority and communication, lot dimensions, accessory dwelling units and cottage housing standards. Public comment on ADU and affordable housing incentives. Allow 253 ADU on ground floor, remove ADU restrictions on subdivision approved before 1997, and remove restrictions for small sized lots only for affordable units. No motions were made at this hearing. On October 30, 2017 the Commission continued their review of the draft development code. The Commission continued their discussion and focused on regulatory communication, lot dimensions, accessory dwelling units, cottage housing standards, and other standards. Public comment was heard on ADU and the B-3 District. Fourteen additional motions were made to amend the draft development code. The subject of some the motions were not included with the official public notice for the UDC update. A copy of the notice contents are included with this memo. Staff will consider all the motions that are outside of the scope of the current notice as direction to the City manager to initiate a zone text amend that include these items. On November 6, 2017 the Commission continued their review of the draft development code. No action was taken. The meeting was continued to Monday, November, 13, 2017. No action was taken on November 13, 2017. The meeting was continued to Wednesday, November, 15, 2017. On November 15, 2017 the Commission continued their review of the draft development code. Numerous amendments were made to the draft development code. The meeting was continued to Monday, November 27, 2017. Two proposed amendment to the development code ended in tie votes (2:2). Those two issues relate to the following, time stamp to video recording included: 1. 07:05:22 PM (01:04:24) Vote on the Amendment to the Motion to add to 38.360.240,2(c) to state, “Individual garages facing the street are not allowed for townhouse or rowhouse dwellings in the B-3 District.” Motion is tied 2-2. 2. 08:49:39 PM (02:48:41) Vote on the Amendment to the Motion to add a phrase to paragraph 3 in section 38.340.090.C after the existing “Whether the subsequent development complies with 38.340.050” add, “; and the neighborhood’s historic significance.” Motion is tied 2-2. Article 5 Revisions Staff has generally revised section 38.530 Building Design standards based on comments received from the design community on November 4, 2017. The design standards found in the July 28, 2017 UDC draft are based on the Bozeman Design Objectives Plan (DOP). The DOP was initiated by the 1990 Bozeman Area Master Plan (Growth Policy). This document recognized the importance role that certain major arterials have in the community. The new master plan called for design review and procedures and suggested particular characteristics such as landscaping, access points, and building design. The 1992 DOP was revised and updated in 2005 resulting in the current version we use today. The Design Objectives Plan includes five chapters covering neighborhood character, site design, building design, signs, and corridor specific design standards. The population of Bozeman has grown from 22,660 in 1990 to approximately 45,250 in 2016, a 97.7 percent increase. The DOP implements numerous community goals and objectives, not just creative architecture. A complete list of community quality goals can be found in Chapter 4 of the Bozeman Community Plan pages 4-3 through 4-8. LINK TO ORIGINAL AUGUST 24, 2017 CITY COMMISSION MEETING MATERIALS (STAFF REPORT) 254 LINK TO SEPTEMBER 7, 2017 CITY COMMISSION MEETING LINK TO SEPTEMBER 11, 2017 CITY COMMISISON MEETING LINK TO SEPTEMBER 18, 2017 CITY COMMISSION MEETING LINK TO OCTOBER 2, 2017 CITY COMMISSION MEETING LINK TO OCTOBER 16, 2017 CITY COMMISISON MEETING LINK TO OCTOBER 23, 2017 CITY COMMISISON MEETING LINK TO OCTOBER 30, 2017 CITY COMMISSION MEETING LINK TO NOVEMBER 15, 2017 CITY COMMISSION MEETING Anticipating discussion on Article 5 – Project Design a link to the DRAFT block frontage map is provided below. Default designations are described in section 38.510.020 (page 359). Draft Block Frontage Map UNRESOLVED ISSUES: Described in the UDC Update staff report. ALTERNATIVES: As determined by the City Commission. FISCAL EFFECTS: None identified. Report compiled on: November 22, 2017 Attachments: Revised Section 38.530 Building Design 255 BOZEMAN UDC – ARTICLE 5 DRAFT Page 1 November 21, 2017 UDC update 7-28-2017 draft Revised section 38.530 Building Design: November 21, 2017 Section 38.530 below replaces the July 28, 2017 draft version in its entirety. All changes to the July 28, 2017 draft are identified with double strikeout for deletion and underlining for addition and highlighted in green to identify the location of changes. Addition to introductory section:  One of the primary goals of the UDC update is to make it easier to use and understand, particularly for those who do not use it on a daily basis. Therefore, staff included photographs and illustrations (collectively referred to as “figures” in the draft) to assist in explaining the intent and standards of a particular section. The design community found the photographs unhelpful and requested that they be replaced with illustrations that more accurately represent the concept. Staff agrees; however, creating new illustrations would require additional financial support that is currently not included in the budget for this project.  To facilitate revising, replacing, and adding figures in the UDC in the future, and to clarify that figures are illustrative and not regulatory, staff suggests adding section 38.100.120: Sec. 38.100.120. – Figures. The figures in this chapter are for illustrative purposes only and do not constitute regulatory standards. Figures may be revised, replaced, or added by administrative order issued by the Director of Community Development. 38.530 Building Design (New) Sec. 38.530.010. – Purpose. See the individual “intent” statements for each section in this division. Sec. 38.530.020. – Applicability and compliance. The provisions of this division apply to all development within Bozeman, except single, two-, and three-household dwellings on individual lots unless otherwise noted. Specifically: A. For clarification on the relationship between the provisions in this division and other documents and codes, see section 38.500.020.A. B. For the application of building additions and remodels and site improvements, see section 38.500.020.B. C. For clarification on how the provisions of this division are applied, see section 38.500.030. 256 BOZEMAN UDC – ARTICLE 5 DRAFT Page 2 November 21, 2017 UDC update 7-28-2017 draft D. The review authority may waive or relax these provisions in the industrial zones depending on the type of use, number of anticipated employees and customers, and the site’s physical context. The greater number of employees and/or customers and higher visibility levels warrant a greater application of building design standards. E. Place holder for Alternative Compliance Evaluation Path (ACEP) Sec. 38.530.030. – Building character. A. Intent. 1. To promote buildings with an architectural character that reflects the region’s aesthetic regionally appropriate architecture that and is based on human scaled design details, durable high quality materials, sustainable design measures, and that responds uniquely to the site’s context. 2. To emphasize that high quality design is most critical to Bozeman’s high visibility sites and corridors. 2. To emphasize high quality design in Bozeman’s built environment. 3. To avoid generic, corporate architectural designs that are not readily reusable or convert to another use that lessens the character and identity of Bozeman. For example, some franchise convenience uses have very specific architectural features (such as a distinctive roofline design that functions as a sign) that reinforce their identity. B. Building character standards and guidelines. 1. Developments within the Neighborhood Conservation Overlay District (NCOD) are subject to 38.340.050compliance with the guidelines for historic preservation & neighborhood conservation overlay district. Where there is a conflict between the NCOD guidelines and the standards of this division, the NCOD guidelines prevail. 2. The Bozeman design manual provides building design aspirations and guidance. It may be used as a tool to help determine whether departures to the building design standards in this division meet the intent of the standards. 3. The building design standards in this division 38.530 must be used to help form the character of new and remodeled buildings. C. Architecture that is defined predominately by corporate identity features and is difficult to adapt to other uses is prohibited. For example, some franchise convenience uses have very specific architectural features (such as a distinctive roofline design that functions as a sign) that reinforce their identity. As tenants change in these types of buildings, these corporate identity features can negatively impact the character of the area and identity of new tenants. These features can also be very expensive to reconfigure and adapt to new uses. Sec. 38.530.040. – Building massing & articulation. A. Intent. 1. To employ façade articulation techniques that reduce the perceived scale of large buildings and add visual interest from all observable scales. 1. To articulate building elements in order to achieve an appropriate perceived scale and add visual interest. 2. To create clear and welcoming building entries. B. Façade articulation - Storefronts and other buildings with non-residential uses on the ground level façade must include articulation features every 40 feet (maximum) to create a Commented [TR1]: Staff comment: Significant policy determination. Without specific review criteria, appeal provisions, costs, staffing requirements, time requirements in place revised path would be difficult to implement, apply, and meet adequate due process standards. Also, we believe the Bozeman Design Manual ought to be in place to support any alternative review path. To a degree, ACEP is built into the draft through departures and PUD alternative. Commented [TR2]: Staff comment: Suggested change to “appropriately” not included Commented [TR3]: Staff comment: An issue of importance to the community. Adapted language from deleted section 38.530.030.C. 257 BOZEMAN UDC – ARTICLE 5 DRAFT Page 3 November 21, 2017 UDC update 7-28-2017 draft human-scaled pattern. At least three of the following features must be employed at intervals no greater than 40 feet. B. Façade articulation - Storefronts and other buildings with non-residential uses on the ground level must include a minimum of three of the following articulation features every 60 feet (maximum) to create a human scaled façade pattern:  1. Windows. patterns and/or 2. Entries. 3. Use of weather protection features. 4. Use of structural expression. vertical piers/columns. 5. Change in roofline per subsection F below. 6. Change in building material or siding style. 7. Articulation of a single building material through varying colors, textures, or incorporating joints or an integrated trim pattern. 8. Other design techniques that effectively reinforce a human-scaled pattern compatible with the building’s surrounding context. Other features that could be used to meet the standards on block frontages that are not designated as storefront: 9. Providing vertical elements such as a trellis with plants, green wall, art element. 10. Providing vertical building modulation of at least 12 inches in depth if tied to a change in roofline per subsection F below or a change in building material, siding style, or color. Departures will be considered provided they meet the intent of the standards and the design criteria set forth in subsection D below: Exceptions: a. Only two articulation features are required on building façades in the BP district; b. Only one articulation feature is required on building façade s in the M-1 district; c. Buildings in the M-2 district are exempt from these standards. d. Building walls facing alleys, rear or side yards are not subject to the standards herein, except for zone edge properties, when adjacent to a lower-intensity zoning district. Commented [TR4]: Staff comment: did not alter to say “appropriately scaled”. We believe the built environment is for humans and functionally meeting our needs. Commented [TR5]: Staff comment: Moved to new line and re-numbered. Commented [TR6]: Staff comment: did not alter to say “appropriately scaled”. We believe the built environment is for humans and functionally meeting our needs. 258 BOZEMAN UDC – ARTICLE 5 DRAFT Page 4 November 21, 2017 UDC update 7-28-2017 draft The left image uses window patterns, weather protection elements, and roofline modulation. The photo example to the right also includes window patterns and weather protection along with brick vertical piers to articulate the façade. The lower example illustrates how a multitenant retail building can successfully be articulated (windows, weather protection, vertical building modulation, and roofline changes) Figure 38.530.040.B Façade articulation examples. C. Façade articulation - Residential buildings must include articulation features at intervals that relate to the location/size of individual units within the building (or no more than every 30 feet) to break up the massing of the building and add visual interest and compatibility to the surrounding context. At least three of the following features must be employed at intervals no greater than the unit interval or 30 feet (whichever is less). C. Façade articulation - Residential buildings must include articulation features at appropriate intervals relative to the scale of the façade in order to reduce the perceived massing of the building and add visual interest. The following features must be employed at intervals relative to the individual dwelling units or at a maximum of every 30 feet. The scale of the façade articulation should be compatible with the surrounding context.  1. Use of windows 2. Entries. Commented [TR7]: Staff comment: see new section 38.100.120 above. Applies to all images in this section. Commented [TR8]: Staff comment: separated line and renumbered. 259 BOZEMAN UDC – ARTICLE 5 DRAFT Page 5 November 21, 2017 UDC update 7-28-2017 draft 3. Use of weather protection features. 4. Use of vertical piers/columns. 5. Change in roofline per subsection F below. 6. Change in building material, and/or siding style, and/or window pattern. 7. Articulation of a single building material through varying colors, textures, or incorporating joints or an integrated trim pattern. 8. Providing vertical building modulation of at least 12 inches in depth if tied to a change in roofline modulation per subsection F below or a change in building material, siding style, or color. Balconies may be used to qualify for this option if they are recessed or projected from the façade by at least 18 inches. Juliet balconies or other balconies that appear to be tacked on to the façade will not qualify for this option unless they employ high quality materials and effectively meet the intent of the standards. 9. Other design techniques that effectively break up the massing at no more than 30-foot intervals. 10. Providing vertical elements such as a trellis with plants, green wall, and/or art element. Departures will be considered provided they meet the intent of the standards and the design criteria set forth in subsection D below. Below examples use a combination of vertical building modulation, window patterns, material changes, and roofline modulation. Commented [TR9]: Staff comment. Staff is not supportive of this option, it is included for discussion. The concept is addressed in other line items and there is insufficient criteria to implement. 260 BOZEMAN UDC – ARTICLE 5 DRAFT Page 6 November 21, 2017 UDC update 7-28-2017 draft Figure 38.530.040.C Residential façade articulation examples D. Departure criteria associated with articulation standards. Proposals must meet the intent of the standards. The following criteria will be considered in determining whether the proposed articulation treatment meets the “intent.” 1. The type and width of the proposed articulation treatment and how effective it is in meeting the intent given the building’s current and desired context (per Bozeman’s growth policy or applicable adopted subarea plan). 2. The applicable block frontage designation. Undesignated block frontages warrant more flexibility than block frontages designated as mixed or landscaped. 3. The size and width of the building. Smaller buildings warrant greater flexibility than larger buildings. 4. The quality of façade materials in concert with doors, windows, and other façade features and their ability to add visual interest to the street from a pedestrian scale and more distant observable scales. This building is a good departure example. Its two clear articulation features are the window patterns and the entry/building modulation feature (3 minimum are required). However, the overall effectiveness of these articulation features combined with the high quality of materials and detailing and the relatively small width of the building help it meet the intent of the standards. Figure 38.530.040.D Façade articulation departure examples E. Maximum façade width. For most buildings, small scale articulation techniques (see subsections B and C above) are sufficient to reduce the perceived scale of buildings, add visual interest, and contribute to the pedestrian environment. Larger buildings need more substantial articulated/modulated features to break up the massing and add visual interest. Building façades wider than 100 150 feet must include at least one of the following features to break up the massing of the building and add visual interest. Building walls facing alleys, rear or side yards Commented [TR10]: Departure criteria is not changed. Adequate objective criteria are required to make objective determinations and eliminate arbitrary and capricious decisions. 261 BOZEMAN UDC – ARTICLE 5 DRAFT Page 7 November 21, 2017 UDC update 7-28-2017 draft are not subject to the standards herein, except for zone edge properties, when adjacent to a lower intensity zoning district. Existing buildings are exempt from subsection E.  1. Provide vertical building modulation at least 20 six feet deep and 30 ten feet wide. For multi- story buildings, the modulation must extend through more than one-half of the building floors. 2. Use a contrasting vertical modulated design component that: a. Extends through all floors above the first floor fronting on the street. Exception: upper floors that are set back more than ten feet horizontally from the façade are exempt; ba. Utilizes a change in building materials that effectively contrast from the rest of the façade; cb. Is modulated vertically from the rest of the façade by an average of six inches. d. Is designed to provide roofline modulation per subsection F below; 3. Façade employs building walls with contrasting articulation that make it appear like two multiple distinct buildings. To qualify for this option, these contrasting façades must employ all of the following: a. Different building materials and/or configuration of building materials; b. Contrasting window design (sizes or configurations). Departures will be considered provided the design meets the intent of the standards. Supplemental consideration for approving alternative designs: • Width of the façade. The larger the façade, the more substantial articulation/ modulation features need to be. • Block frontage designation. Storefront designated block frontages warrant the most scrutiny, while undesignated streets warrant more flexibility. • The type of articulation treatment and how effective it is in meeting the intent given the building’s context. Less than 100 or 120’ 150’ wide: Meets standard More than 100 or 120’ 150’ wide: Does not meet standard Commented [TR11]: Departure criteria is not changed. Adequate objective criteria re required to make objective determinations and eliminate arbitrary and capricious decisions. Commented [TR12]: Illustrations need to be updated to new standard. 262 BOZEMAN UDC – ARTICLE 5 DRAFT Page 8 November 21, 2017 UDC update 7-28-2017 draft Building incorporates a 20’x30’ 6’x10’ courtyard along the façade to effectively break it up into smaller components: Meets standard. Both buildings use modulated entry feature to help break up the perceived massing and add visual interest. Figure 38.530.040.E Illustrating maximum façade width standards and good and bad examples. The left building on East Main (about 110’ wide) uses an articulated partial third floor along with smaller articulation treatments on the main floors to effectively break up the perceived scale and add visual interest (this would be a good departure example). The building to the right would not be an acceptable example. While the articulated features on the lower floors help, the monotony of the very long upper floor and roofline would not be acceptable. Figure 38.530.040.E Illustrating maximum façade width standards and good and bad examples. F. Roofline modulation. In order to qualify as a façade articulation feature in subsections B, C, and E above, rooflines must employ one or more of the following:  1. For flat roofs or façades with horizontal eave, fascia, or parapet, the minimum vertical dimension of roofline modulation is the greater of two feet or 0.1 multiplied by the wall height (finish grade 263 BOZEMAN UDC – ARTICLE 5 DRAFT Page 9 November 21, 2017 UDC update 7-28-2017 draft to top of the wall) when combined with vertical building modulation techniques described in subsections above. Otherwise, the minimum vertical dimension of roofline modulation is the greater of four feet or 0.2 multiplied by the wall height an extension of the parapet or a break in the parapet of at least one foot measured from the adjacent roof or adjacent parapet. If no parapet is present a horizontal roof edge/eave extension of at least two feet. 2. A pitched roofline segment(s) scaled appropriately to the façade. or gabled roofline segment of at least 20 feet in width. Buildings with pitched roofs must include a minimum slope of 5:12 and feature modulated roofline components at the interval required per the applicable standard above. 3. A combination of the above. Departures will be considered provided the roofline modulation design effectively reduces the perceived scale of the building and adds visual interest. Roofline modulation examples for flat roofs. Figure 38.530.040.1 Acceptable examples of roofline modulation. The left building illustrates a pitched roof example and the right building includes a combination of flat and gabled rooflines. Figure 38.530.040.1 Acceptable examples of roofline modulation. Commented [TR13]: Staff comment. No change to departure criteria included. Intent statements are guiding principles and regulatory standards. 264 BOZEMAN UDC – ARTICLE 5 DRAFT Page 10 November 21, 2017 UDC update 7-28-2017 draft Sec. 38.530.050. – Building details. A. Intent: 1. To encourage the incorporation of design details and small-scale elements into building façades that are attractive at a pedestrian scale. 1. To encourage building façades with attractive design details at an appropriate pedestrian scale relative to the overall composition of the building. 2. To integrate window design that adds depth, richness, and visual interest to the façade. B. Façade details – non-residential and mixed-use buildings. All commercial and mixed-use buildings must be enhanced with appropriate details. All new buildings, additions and buildings associated with Level II and III Improvements (see section 38.500.020.B) must employ at least one detail element from each of the three categories below for each façade facing a street or public space for each façade articulation interval (see section 38.530.040). For example, a building with 120 feet of street frontage with a façade articulated at 40-foot intervals will need to meet the standards for each of the three façade segments below. 1. Window and/or entry treatment, such as: a. Display windows divided into a grid of multiple panes; b. Transom windows; c. Roll-up windows/doors; d. Other distinctive window treatment that meets the purpose of the standards; e. Recessed entry; f. Decorative door; g. Other decorative or specially designed entry treatment that meets the intent of the standards. C B A 265 BOZEMAN UDC – ARTICLE 5 DRAFT Page 11 November 21, 2017 UDC update 7-28-2017 draft Examples of decorative or specially designed windows and entries. A = Openable storefront window. B = Transom windows. C = Openable window with decorative details. D = Decorative window shades. E = Decorative door. F = Recessed entry. Figure 38.530.050.B.1 Examples of decorative or specially designed windows and entries 2. Building elements and façade details, such as: a. Custom-designed weather protection element such as a steel canopy, cloth awning, or retractable awning; b. Decorative building-mounted light fixtures; c. Bay windows, trellises, towers, and similar elements; d. Decorative, custom hanging sign(s) (option only available for building remodels); e. Other details or elements that meet the purpose of these standards. D E F C B A D F E 266 BOZEMAN UDC – ARTICLE 5 DRAFT Page 12 November 21, 2017 UDC update 7-28-2017 draft Examples of elements attached to façades that enhance the visual intrigue of the building. A = Retractable awning. B = Custom hanging bike rack and repair station integrated as a storefront design element. C = Decorative façade/sign lighting. D and E = Custom decorative canopy. F = Decorative tower. Figure 38.530.050.B.2 Examples of attached elements that enhance the visual intrigue of the building. 3. Building materials and other façade elements, such as: a. Use of decorative building materials/use of building materials. Examples include decorative use of brick, tile, or stonework; b. Artwork on building (such as a mural) or bas-relief sculpture; c. Decorative kick-plate, pilaster, base panel, or other similar feature; d. Hand-crafted material, such as special wrought iron or carved wood; e. Other details that meet the purpose of the standards. “Custom,” “decorative,” or “hand-crafted” elements referenced above must be distinctive or “one- of-a-kind” elements or unusual designs that require a high level of craftsmanship. Examples of decorative surface materials. A = Decorative brick/design. B = Decorative tile-work and column pattern. C = Decorative medallion. Figure 38.530.050.B.3 Examples of decorative surface materials D = Decorative mosaic tile work. E = Decorative bulkhead. F = Decorative materials and design. A B C F E F D 267 BOZEMAN UDC – ARTICLE 5 DRAFT Page 13 November 21, 2017 UDC update 7-28-2017 draft Figure 38.530.050.B.3 Examples of decorative surface materials Departures will be considered provided the façade (at the overall scale and at the individual articulation scale) meets the intent of the standards above. C B. Window design standards. 1 All windows (except storefront display windows) must be recessed at least two inches from the façade or incorporate other design treatments that add depth, richness, and visual interest to the façade. 1. All windows (except storefront windows and curtain walls) must include trim or other design treatment, or alternately be recessed at least two inches from the façade. Understated or trim- less windows without additional design treatment are permitted provided the placement and design is integrated into the overall composition of the building.  2. Prohibited windows: a. Mirrored glass is prohibited. b. Continuous ribbon windows are prohibited. Departures to the window standards above will be considered provided the design meets the intent of the standards. Recessed and/or trimmed windows. The window in the left image lacks any other detail that adds visual interest. Figure 38.530.050.C Acceptable and unacceptable window design examples DC. High visibility street corner and gateway sites. All development proposals located at designated high visibility street corners and gateway sites must locate a building or structure within 20 feet of the street corner and include special design features that accentuate the street corner. Alternatively, the building could be configured with a corner plaza. Corner design features could 268 BOZEMAN UDC – ARTICLE 5 DRAFT Page 14 November 21, 2017 UDC update 7-28-2017 draft include a cropped building corner with an special entry feature, decorative use of building materials at the corner, distinctive façade articulation, a sculptural architectural element, or other decorative elements that meet the intent of the standards. Figure 38.530.050.D below illustrates acceptable examples. Building 1 includes a corner tower. Building 2 features cropped building corners with decorative elements. Building 3 uses a decorative functional canopy. Building 4 uses a change in building materials and façade articulation at the corner. Building 5 incorporates a plaza at the corner. Figure 38.530.050.D Acceptable high visibility street corner /gateway site examples. Building 6 shows a decorative landscaped area with a trellis and neighborhood gateway sign. Figure 38.530.050.D Acceptable high visibility street corner /gateway site examples. 2 1 3 5 4 6 269 BOZEMAN UDC – ARTICLE 5 DRAFT Page 15 November 21, 2017 UDC update 7-28-2017 draft E. Cornice/roofline design. Buildings employing a flat roof must feature a distinctive roofline that effectively provides an identifiable “top” to the building. This could include a traditional cornice line or a contemporary interpretation of a traditional cornice line. Such rooflines must be proportional to the size and scale of the building. Understated cornice lines are permitted depending on the materials and design of the base and middle elements used to reinforce the base/middle/top configuration. Figure 38.530.050.E below illustrate acceptable and unacceptable examples. Building 1 uses a dramatic overhanging cornice at the corner. The left portion of Building 1 uses a very simple cornice line – to complement the upper level setback. Building 2 uses a traditional cornice line. Figure 38.530.050.E Examples of buildings employing confident and distinctive rooflines. Building 3 uses capped projecting columns along with an understated cornice line. Building 4 uses a very simple roofline – which is acceptable in this case due to the prominence of the wooden canopy. Figure 38.530.050.E Examples of buildings employing confident and distinctive rooflines. D. Active Solar Collection Units (electronic and hydronic) Rooftop solar units are permitted, provided the placement and design of units visible from the surrounding streetscape is carefully integrated into the overall design concept of the building. 2 1 4 3 270 BOZEMAN UDC – ARTICLE 5 DRAFT Page 16 November 21, 2017 UDC update 7-28-2017 draft FE. Articulated building entries. The pPrimary building entrance(s) for an office building, hotel, apartment building, public or community-based facility or other multi-story commercial building must be designed as a must be clearly defined and demarcated standout architectural feature of the building. Such entrances must be easily distinguishable from regular storefront entrances on the building. Such entries must be scaled proportionally to the building. See Figure 38.530.050.F below and the Bozeman design manual for good examples. Figure 38.530.050.F Acceptable building entry examples. F. Departures to building detail standards will be considered if they are determined to meet the intent of the standards in section 38.530.050 – Building Details. Commented [TR14]: Staff comment. Departures now apply generally to all building details standards. No change to language. 271 BOZEMAN UDC – ARTICLE 5 DRAFT Page 17 November 21, 2017 UDC update 7-28-2017 draft Sec. 38.530.060. – Building materials. A. Intent. 1. To encourage the use of durable, high quality, and urban building materials that minimize maintenance costs and provide visual interest from all observable vantage points. 2. To promote the use of a distinctive mix of materials that helps to articulate façades and lends a sense of depth and richness to the buildings. 3. To place the highest priority on the first floor in the quality and detailing of materials at the pedestrian scale. 1. To encourage the use of durable materials to provide visual interest from vehicular and pedestrian vantage points with the highest priority at locations susceptible to damage from maintenance and weathering. B. Quality building materials. Applicants must use high quality durable materials. This is most important for the base of buildings, particularly for commercial and mixed-use buildings where the façade is sited close to sidewalks. At a minimum, stone, brick or tile masonry, or architectural concrete (first two feet only) must be used (excluding window and door areas) for the first floor of cladding on non-residential or mixed-use buildings and the first two feet of residential buildings. B. Durable building materials. Applicants must use durable materials. Where façades are located directly adjacent to a city sidewalk, impact resistant materials must be used (excluding window and door areas) for a minimum of the first 18” above the walking surface. C. Special conditions and limitations for the use of certain cladding materials. 1. Concrete block (a.k.a. CMU) may be used as a secondary cladding material if it is incorporated with other permitted materials. Alternative designs that use concrete block as the primary, but not the only, cladding material will be considered via departure provided the design incorporates a combination of textures and/or colors to add visual interest. For example, combining split or rock-façade units with smooth blocks can create distinctive patterns. The figures below illustrate acceptable concrete block use/designs. 1. Concrete block (a.k.a. CMU) when used as a primary cladding material, must be treated or articulated to provide visual interest above and beyond natural (uncolored, untreated) block with (matching) natural colored grout. Examples of such treatments include using ground, polished or split face units; creating patterns/texture with different block sizes, face treatments, or colors; creating patterns/textures by modulating the finish plane of units; utilizing contrasting grout color; or utilizing sealers or painted treatments that enhance the finish of natural concrete block. Industrial zoning districts are exempt from subsection C. Commented [TR15]: Staff comment – Generally revised intent based on design community comments. “Appropriate” is also vague, no definition or reference point. Focus on human and pedestrian scale to maintain community character and desires. 272 BOZEMAN UDC – ARTICLE 5 DRAFT Page 18 November 21, 2017 UDC update 7-28-2017 draft CMU is the primary cladding for the corner element above, but secondary to brick on the main façades. The corner element uses a combination of decorative split faced CMU closer to the sidewalk and smooth-faced CMU that is colored to look more like traditional white terra cotta tiles. The above façade illustrates an acceptable alternative example, as CMU is used as the primary cladding material. Note the use of split-façade CMU’s above each of the awnings and coupled with the use of smooth-façade CMU’s on the vertical columns (which employ black accent tiles for added interest). Figure 38.530.060.C.1 Acceptable concrete block use/design 2. Metal siding may be used as a secondary cladding material if it is incorporated with other permitted materials and complies with the following standards  a. It must feature visible corner molding and trim and must not extend to the ground level of non-residential and mixed-use buildings, and extend no lower than two feet above grade for residential buildings. Masonry, concrete or other durable material must be incorporated between the metal siding and the ground plane; b. Metal siding must be factory finished, with a matte, non-reflective surface. a. Metal siding must be a minimum 24 gauge thickness. Re-purposed metal siding is exempt from minimum thickness requirements provided its material integrity is intact. b. Metal siding must feature appropriate molding, trim, or hemming at all exposed edges and corners. c. Metal siding must be factory finished, or alternately purposefully designed to naturally patina. Highly reflective galvanized finished are prohibited. Re-purposed or re-claimed metal siding is permitted. Departures will be considered provided the material’s integration and overall façade composition meets the intent of the standards. 273 BOZEMAN UDC – ARTICLE 5 DRAFT Page 19 November 21, 2017 UDC update 7-28-2017 draft The use of metal siding in each example above is secondary to masonry. The left and right images are more contemporary in character, whereas the middle image is more rustic and industrial, with more refined windows. Figure 38.530.060.C.2 Acceptable metal siding examples 3. Standards for the use of Exterior Insulation and Finish System (EIFS). Such material/finishes may be used as a decorative accent cladding material if it is incorporated with other permitted materials and it complies with the following: a. On buildings of three or more stories or 5,000 square feet in footprint or greater EIFS is limited to no more than 205 percent of the total façade area and is not the primary cladding material. On buildings of two stories or less or less than 5,000 square feet in footprint, EIFS is limited to 60 percent of the total façade area.; b. EIFS must feature a smooth or sand finish Highly textured EIFS finishes are prohibited; c. EIFS must be trimmed in wood, masonry, or other material and must be sheltered from weather by roof overhangs or other methods EIFS must include an integrated joint or trim pattern; d. EIFS must not be used on the ground floor when facing a street, internal access road or pathway. Concrete, masonry, or other durable material must be used for ground level wall surfaces to provide a durable surface where damage is most likely. EIFS must not be used on the ground floor when directly adjacent to a sidewalk, pedestrian or vehicular pathway. Departures will be considered provided the material’s integration and overall façade composition meets the intent of the standards. 274 BOZEMAN UDC – ARTICLE 5 DRAFT Page 20 November 21, 2017 UDC update 7-28-2017 draft Note the use of brick and decorative concrete block on the ground level and EIFS on the second floor of the left image. The window treatments visible on the second floor add depth and interest to the façade. The right image employs EIFS between the window and sidewalk – this design is prohibited. Figure 38.530.060.C.3 Acceptable and unacceptable EIFS examples. 4. Cementitious wall board paneling/siding may be used provided it meets the following provisions: a. Cement board paneling/siding may not be used on the ground floor of non-residential or mixed-use buildings where adjacent to a sidewalk or other pedestrian path; b. Where cement board paneling/siding is the dominant siding material, the design must integrate a mix of colors and/or textures that are articulated consistent with windows, balconies, and modulated building surfaces and are balanced with façade details that add visual interest from the ground level and adjacent buildings. Departures will be considered provided the material’s integration and overall façade composition meets the intent of the standards. D.  Departures to building materials standards will be considered if they are determined to meet the intent of 38.530.060 – Building Materials. Sec. 38.530.070. – Blank wall treatments. A. Intent. 1. To avoid untreated blank walls. 2. To retain and enhance the character of Bozeman’s streetscapes. B. Blank wall definition. A wall (including building façades and retaining walls) is considered a blank wall if it is over ten feet in height, has a horizontal length greater than 15 feet, and does not include a transparent window or door. Commented [TR16]: Staff comment. Design community wishes to delete this section in its entirety. Staff agrees cementitious wall board can be durable. However, there appears to be a conflation of the terms durable and quality. Staff cannot determine based on the information provided by the design community that removing this section does not unduly burden the community by ignoring the majority of the goals and objectives to focus on creating guidelines that simply allow architectural expression. 275 BOZEMAN UDC – ARTICLE 5 DRAFT Page 21 November 21, 2017 UDC update 7-28-2017 draft Figure 38.530.070.B Blank wall definition C. Untreated blank walls visible from a public street, pedestrian-oriented space, common usable open space, or pedestrian pathway are prohibited. Methods to treat blank walls may include: 1. Display windows with at least 16 inches of depth to allow for changeable displays. Tack on display cases do not qualify as a blank wall treatment. 2. Landscape planting bed at least five feet wide or a raised planter bed at least two feet high and three feet wide in front of the wall with planting materials that are sufficient to obscure or screen at least 60 percent of the wall’s surface within three years. 3. Installing a vertical trellis in front of the wall with climbing vines or plant materials. 4. Installing a mural as approved by the review authority. 5. Special building detailing that adds visual interest at a pedestrian scale. Such detailing must use a variety of surfaces; monotonous designs will not meet the purpose of the standards. For large visible blank walls, a variety of treatments may be required to meet the intent of the standards. Figure 38.530.070.C Acceptable and unacceptable blank wall treatments. Note in the far right example, the display cases don’t meet the 16” depth requirement, nor does the design meet the intent of the standards. 276