Loading...
HomeMy WebLinkAbout5 West Mendenhall St - Fire & Water Services6"wm6"wm6"wm6"wm6"wm8"wm8"wmcomm comm comm comm commcommcommcommcommcomm NORTH TRACY AVENUESS8"ss6"ss6"ssWSWSFFF4"CT4"CT4"CT0+220+002C3026" FIRE LINEELEVATIONSTATION479548004810482047954800481048200+004807.381+00STATION 0+2.00INSTALL NEW 6" TAPPING VALVE,MJ W/ THRUST BLOCK.INV: 4800.38EXISTINGGRADEFINISHEDGRADESTATION 0+12.97INSTALL NEW 6" 11.25° BEND FITTING,MJ W/ THRUST BLOCK.INV: 4800.386.5' MIN.DEPTHOF COVERSTATION 0+17.50INSTALL NEW 6" 11.25° BEND FITTING,INV: 4799.24STATION 0+00INSTALL NEW TAPPING TEE,MJ W/ THRUST BLOCK.STATION 0+25.76INSTALL NEW 6" 90° BEND FITTING,INSTALL OS&Y VALVE.SEE PLUMBING PLANS FOR CONTINUATION.2.0'MIN.BUILDING BASEMENTFFE: 4797.222.0'MIN.BUILDING 1ST FLOORFFE: 4807.478 LF 6" CLASS 51FIRE SERVICE4 LF 6" CLASS 51FIRE SERVICE11 LF 6" CLASS 51FIRE SERVICE10" SCH 40 GALV STEEL SLEEVETHRU WALL. SEAL ANNULAR SPACEWITH WATERPROOF MASTIC.6"wm6"wm6"wm6"wm6"wm8"wm8"wmcomm comm comm comm comm comm comm comm comm comm NORTH TRACY AVENUES S8"ss6"ss6"ssWSWSFFF4"CT4"CT4"CT0+000+22ELEVATIONSTATION479548004810482047954800481048200+004807.411+00STATION 0+2.00 INSTALL NEW 4" TAPPING VALVE, MJ W/ THRUST BLOCK. INV: 4800.47EXISTINGGRADEFINISHEDGRADESTATION 0+8.61 INSTALL NEW 6" 11.25° BEND FITTING, INV: 4800.47 6.5' MIN.DEPTHOF COVERSTATION 0+00 INSTALL NEW TAPPING TEE, MJ W/ THRUST BLOCK.BUILDING BASEMENTFFE: 4797.22BUILDING 1ST FLOORFFE: 4807.475 LF 4" DIWATER SERVICE8.5 LF 4" DIWATER SERVICE8.5 LF 4" DIWATER SERVICE6" SCH 40 GALV STEEL SLEEVETHRU WALL. SEAL ANNULAR SPACEWITH WATERPROOF MASTIC.STATION 0+17.21 INSTALL NEW 4" 11.25° BEND FITTING, INV: 4798.30INV IN: 4798.30NOTE TO CONTRACTOR -CALL 1-800-424-5555 TWO WORKINGDAYS PRIOR TO ANY EXCAVATION TOHAVE ALL EXISTING UTILITIESLOCATED.1C302FIRE SERVICE PLAN SCALE: 1" = 20'NORTH40'20'10'0REVISIONS ALL RIGHTS RESERVEDCHECKED BY:CTA #DATE:DRAWN BY:CTA INC.®SHEETCOPYRIGHTMENDENHALL MIXED USE 5 WEST MENDENHALL ST. BOZEMAN, MT RECORD DRAWING05/02/2017MNDNHALL_CSN2017H:\MNDNHALL_CNS\CNS\Civil\MNNSC302.dwg FIRE AND WATER SERVICEPLAN AND PROFILEKAEGC3022C302FIRE SERVICEPROFILE VIEW HORIZONTAL SCALE: 1" = 20'VERTICAL SCALE: 1" = 5'**NOTE:1. FIRE SERVICE INSTALLATION PER 5/C302 ANS 6/C302.2. SEE FIRE PROTECTION PLANS FOR CONTINUATION INTO BUILDING.4C302WATER SERVICEPROFILE VIEW HORIZONTAL SCALE: 1" = 20'VERTICAL SCALE: 1" = 5'3C302WATER SERVICE PLAN SCALE: 1" = 20'NORTH40'20'10'05C302FIRE SERVICE INSTALLATIONCLASS I, II, & III NORTH4C3024" WATER SERVICENOTE: CLASS 1 SYSTEM FOR BACKFLOW PROTECTIONGENERAL NOTE:1. USING FIRE HYDRANT FLOW DATA AND AN ORIFICE COEFFICIENT F .82 A9.56 INCH ORIFICE WILL PRODUCE A VELOCITY OF 10FT/SEC.