HomeMy WebLinkAboutES1013'-0"
3" CLR
6'-0"
2" CLR
25'-0"+/- .75" GROUT BED UNDERLIGHT POLE BASEANCHOR BOLTS AND FULL BASECOVER PER LIGHT POLEMANUFACTURER. SEE LIGHT POLEMANUFACTURER TEMPLATE TO SETANCHOR BOLTSINTERIOR PAINTED WITHRUST INHIBITIVE PRIMERPROVIDE IN-LINE FUSE WITHINSULATED FUSE HOLDER HEREHAND HOLE COVERROUND STEEL POLEPAINTED TO MATCH FIXTURESEE FIXTURE SCHEDULE FORFIXTURE HEAD REQUIREMENTS.75" CHAMFER ALL EXPOSED EDGES2 SETS #4 TIES IN TOP 5" OF BASE4 SETS #4 TIES AT 12" OC#6 .75" CONDUITCONDUIT WITH J-BOX (TYPICAL)8 #6 BARS VERTICAL WITH 3SETS #4 TIES AT 18" OCEXCEPT AS NOTED ABOVE24"Ø CONCRETE BASE8' X .75" COPPERWELD GROUND RODBUS STOPPHASE 3PHASE 1PHASE 2PHASE 1PHA
S
E
1
P
H
A
S
E
2
PHASE 3PHASE 1 PHASE 3 PHASE 3PHASE 2PHASE 2 (ZL-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)ZL-1DZL-1DZL-1DZL-1DZL-1D(ZL-1)(ZL-1)(ZL-1)(ZL-1)(ZL-1)(ZL-1)(ZL-1)(ZL-1)(OC-1)(OC-1)(DL-1)(DL-1)(DL-1)(DL-1)(DL-1)(DL-1)(DL-1)(DL-1)(DL-1)(DL-1) LIGHTING FIXTURE SCHEDULENOTE TO
B
IDDERS
:
COMPLY
WITH THE SPECIF
ICAT
IONS.
REFER TO
SPEC
IFICATIONS
FOR
IMPORTANT
TECHN
ICAL
REQU
IREMENTS FOR
LIGHT
ING F
IXTURES
, BALLASTS,
AND LAMPS
. THE
CATALOG
NUMBERS
LISTEDBELOW HAVE BEEN CAREFULLY
PREPARED
TO
ASS
IST
B
IDDERS
IN
SELECT
ING
PRODUCTS
TO
ACHIEVE
THE
DESIGN CONCEPT,
HOWEVER
, PRIOR
TO
BIDD
ING
,EACH MANUFACTURER
SHALL COMPARE THE CATALOG
NUMBERS SHOWN WITH THE
DESCR
IPTION
AND REQUIREMENTS
ON
THE DRAWINGS
, AND
SHALLNOTIFY THE ARCHITECT
/ENGINEER
OF ANY DISCREPANCIES.
SPECIF
ICALLY
INCLUDED
IN
TH
IS EVALUATION
SHALL
BE
THE VERIFYING
OF
PROPER MOUNTINGKITS
OR ACCESSOR
IES
TO FACIL
ITATE
INSTALLATION
AS
SHOWN AT EACH
LOCAT
ION
ON THE DRAW
INGS.
NO
ALLOWANCE OR REDRESS
WILL
BE
ALLOWEDFOR DISCREPANCIES THAT WERE
NOT REPORTED
TO
THE ARCH
ITECT/ENG
INEER
IN
T
IME
FOR CORRECT
ION OR
CLARIF
ICAT
ION BEFORE THE
BID.
THEREPORTING OF
ANY AMB
IGU
ITY
IS THE RESPONS
IB
ILITY OF THE BIDDER
. PROVIDE UNIT PRICES AND
F
IXTURE BRAND SELECTED
FOR ADD
/DELETE CHANGESFOR EACH FIXTURE
TYPES SHOWN
WITHIN
48
BUS
INESS HOURS
OF
THE
B
ID
DATE.
FAILURE
TO
COMPLY W
ITH
TH
IS REQUIREMENT
MAY D
ISQUAL
IFY
THEPRODUCTS AND EMPOWER THE
ENGINEER TO DETERM
INE
FA
IR VALUE FOR FIXTURE
AND
INSTALLAT
ION CHANGES
, W
ITHOUT FURTHER
INPUT
FROM
THECONTRACTOR OR
INSTALLER
. SUBM
ITTAL PACKAGE
SHALL
INCLUDE
LAMP MANUFACTURER AND
CATALOG NUMBER
ON
EACH
FIXTURE
SHEET
. ON ALLPENDANT MOUNTED FIXTURES,
PROVIDE A SECOND
SET
OF
PENDANTS,
OF A
D
IFFERENT
LENGTH
, AS DIRECTED BY THE ARCHITECT
/ENGINEER
, PROVIDEDAND INSTALLED AT NO ADDITIONAL
CHARGE.
ALL
FIXTURES SHALL
BE
APPROVED
BY
UL OR
ANOTHER ACCEPTABLE TESTING
LAB
FOR THE PURPOSE
INTENDED AND W
ITH
THE
LAMP
AND
BALLAST
PROPOSED
. CONTRACTOR
ALLOWANCE
PRICES ARE
ACCURATE WHEN
TH
IS JOB WAS SPEC
IFIED,CONTRACTOR AND ELECTR
ICAL D
ISTRIBUTOR SHALL
VER
IFY
TH
IS ALLOWANCE
AND REPORT ANY
PROBLEMS TO
THE
ENGINEER BEFORE THE BID
.ALLOWANCE PRICE MAY OR MAY
NOT
INCLUDE
LAMP(S)
OR FREIGHT
AS
NOTED
, AND
DO NOT
INCLUDE ANY
TAXES.
UN
IVERSAL
VOLTAGE
(120/277
)BALLASTS REQU
IRED UNLESS NOTED OTHERW
ISE
. DIMENSION
SEQUENCE =
(LENGTH
X W
IDTH X
DEPTH
)
IN
INCHES.SYMBOLNEW POWERTRANSFORMER82.6"x76.0"x71.9"NEW METER CABINET70"x41"x90" LIGHTING FIXTURE SCHEDULENOTE TO BIDDERS: COMPLY WITH THE SPECIFICATIONS. REFER TO SPECIFICATIONS FOR IMPORTANT TECHNICAL REQUIREMENTS FOR LIGHTING FIXTURES, BALLASTS, AND LAMPS. THE CATALOG NUMBERS LISTEDBELOW HAVE BEEN CAREFULLY PREPARED TO ASSIST BIDDERS IN SELECTING PRODUCTS TO ACHIEVE THE DESIGN CONCEPT, HOWEVER, PRIOR TO BIDDING,EACH MANUFACTURER SHALL COMPARE THE CATALOG NUMBERS SHOWN WITH THE DESCRIPTION AND REQUIREMENTS ON THE DRAWINGS, AND SHALLNOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES. SPECIFICALLY INCLUDED IN THIS EVALUATION SHALL BE THE VERIFYING OF PROPER MOUNTINGKITS OR ACCESSORIES TO FACILITATE INSTALLATION AS SHOWN AT EACH LOCATION ON THE DRAWINGS. NO ALLOWANCE OR REDRESS WILL BE ALLOWEDFOR DISCREPANCIES THAT WERE NOT REPORTED TO THE ARCHITECT/ENGINEER IN TIME FOR CORRECTION OR CLARIFICATION BEFORE THE BID. THEREPORTING OF ANY AMBIGUITY IS THE RESPONSIBILITY OF THE BIDDER. PROVIDE UNIT PRICES AND FIXTURE BRAND SELECTED FOR ADD/DELETE CHANGESFOR EACH FIXTURE TYPES SHOWN WITHIN 48 BUSINESS HOURS OF THE BID DATE. FAILURE TO COMPLY WITH THIS REQUIREMENT MAY DISQUALIFY THEPRODUCTS AND EMPOWER THE ENGINEER TO DETERMINE FAIR VALUE FOR FIXTURE AND INSTALLATION CHANGES, WITHOUT FURTHER INPUT FROM THECONTRACTOR OR INSTALLER. SUBMITTAL PACKAGE SHALL INCLUDE LAMP MANUFACTURER AND CATALOG NUMBER ON EACH FIXTURE SHEET. ON ALLPENDANT MOUNTED FIXTURES, PROVIDE A SECOND SET OF PENDANTS, OF A DIFFERENT LENGTH, AS DIRECTED BY THE ARCHITECT/ENGINEER, PROVIDEDAND INSTALLED AT NO ADDITIONAL CHARGE. ALL FIXTURES SHALL BE APPROVED BY UL OR ANOTHER ACCEPTABLE TESTING LAB FOR THE PURPOSEINTENDED AND WITH THE LAMP AND BALLAST PROPOSED. CONTRACTOR ALLOWANCE PRICES ARE ACCURATE WHEN THIS JOB WAS SPECIFIED,CONTRACTOR AND ELECTRICAL DISTRIBUTOR SHALL VERIFY THIS ALLOWANCE AND REPORT ANY PROBLEMS TO THE ENGINEER BEFORE THE BID.ALLOWANCE PRICE MAY OR MAY NOT INCLUDE LAMP(S) OR FREIGHT AS NOTED, AND DO NOT INCLUDE ANY TAXES. UNIVERSAL VOLTAGE (120/277)BALLASTS REQUIRED UNLESS NOTED OTHERWISE. DIMENSION SEQUENCE = (LENGTH X WIDTH X DEPTH) IN INCHES.SYMBOLMARKDLDL-1OCOC-1ZLZL-1ZL-1DFIXTURE CHARACTERISTICSBODY / AIR / MOUNTING / DOORLENS/LOUVER/REFLECTOR/OTHERRECESSED CANOPY LIGHT6" L SERIES LED RECESSED MODULE16" WIDE TRAPEZOIDEXTERIOR TRAPEZOIDLIGHT POLES: TOTALLY ENCLOSED RAINTIGHT, DUST-TIGHT AND CORROSION RESISTANT; POLE AS SHOWN IN DETAIL WITH HANDHOLE, COVER, BOLT COVER, AND BASE; PAINTED (COLOR TO BE SELECTED BY ARCHITECT / ENGINEER WHICH MAY DIFFER FROM CATALOG NUMBER SHOWN). MTB= 120,208,240,277 VOLT MULTI-TAP BALLAST. ALL BALLASTS PS. ARM MOUNT. HORIZONTAL LAMP.SHOEBOX STYLE, CUTOFF LUMINAIRE SINGLE HEAD, TYPE III DISTRIBUTION LEDSHOEBOX STYLE, CUTOFF LUMINAIRE TWO SINGLE HEADS, TYPE III DISTRIBUTION LEDLAMPLEDLEDLEDLEDWATTS13W47W421W842WVOLTS277/120V277/120VMVOLTMVOLTMANUFACTURERLITHONIALITHONIAEATONLSISPAULDINGMCGRAW-EDISONMCGRAW-EDISONCATALOG NUMBER6BLMW LEDWST LED 2 10A700/50K SR2 MVOLT PE XXXXXIST-E01-LED-E1-BL2-SCBA-7050XGBWM3-WT-LED-28-450-CW-UE-CBA-PCXXXTRP-30L5K-053-3-U-SCBA-PCGLEON-AE-08-LED-E1-T3GLEON-AE-08-LED-E1-T3 (2)NOTESUNLESS A PROFESSIONAL SEAL WITH SIGNATURE ANDDATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY ANDIS NOT INTENDED FOR CONSTRUCTION, RECORDINGPURPOSES OR IMPLEMENTATION.SHEET TITLEDESIGNED BY:DRAWN BY:DATE:CAD DWG FILE NO:DESIGN SEQUENCE PROJECT NO:AGENCY PROJECT NO:DWG TYPE:ARCHITECTURAL PHASE:1516.01BLACKMOREMARKET PLACEPERMIT SET324 S. State St., Suite 400Salt Lake City, UT 84111800-678-7077801-328-5151fax: 801-328-5155www.spectrum-engineers.comC:\Users\bxc\Documents\20160183 - Elec Central_bxc.rvt10/10/2016 12:06:27 PM
PJGBC10/10/16ELECTRICAL SITE PLANES101Mark:Date:DescriptionSCALE:NTSPARKING LOT LIGHT POLE BASEDETAIL2SCALE: 1" = 40'-0"1SITE PLANNORTH10/13/16