Loading...
HomeMy WebLinkAboutES1013'-0" 3" CLR 6'-0" 2" CLR 25'-0"+/- .75" GROUT BED UNDERLIGHT POLE BASEANCHOR BOLTS AND FULL BASECOVER PER LIGHT POLEMANUFACTURER. SEE LIGHT POLEMANUFACTURER TEMPLATE TO SETANCHOR BOLTSINTERIOR PAINTED WITHRUST INHIBITIVE PRIMERPROVIDE IN-LINE FUSE WITHINSULATED FUSE HOLDER HEREHAND HOLE COVERROUND STEEL POLEPAINTED TO MATCH FIXTURESEE FIXTURE SCHEDULE FORFIXTURE HEAD REQUIREMENTS.75" CHAMFER ALL EXPOSED EDGES2 SETS #4 TIES IN TOP 5" OF BASE4 SETS #4 TIES AT 12" OC#6 .75" CONDUITCONDUIT WITH J-BOX (TYPICAL)8 #6 BARS VERTICAL WITH 3SETS #4 TIES AT 18" OCEXCEPT AS NOTED ABOVE24"Ø CONCRETE BASE8' X .75" COPPERWELD GROUND RODBUS STOPPHASE 3PHASE 1PHASE 2PHASE 1PHA S E 1 P H A S E 2 PHASE 3PHASE 1 PHASE 3 PHASE 3PHASE 2PHASE 2 (ZL-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)(OC-1)ZL-1DZL-1DZL-1DZL-1DZL-1D(ZL-1)(ZL-1)(ZL-1)(ZL-1)(ZL-1)(ZL-1)(ZL-1)(ZL-1)(OC-1)(OC-1)(DL-1)(DL-1)(DL-1)(DL-1)(DL-1)(DL-1)(DL-1)(DL-1)(DL-1)(DL-1) LIGHTING FIXTURE SCHEDULENOTE TO B IDDERS : COMPLY WITH THE SPECIF ICAT IONS. REFER TO SPEC IFICATIONS FOR IMPORTANT TECHN ICAL REQU IREMENTS FOR LIGHT ING F IXTURES , BALLASTS, AND LAMPS . THE CATALOG NUMBERS LISTEDBELOW HAVE BEEN CAREFULLY PREPARED TO ASS IST B IDDERS IN SELECT ING PRODUCTS TO ACHIEVE THE DESIGN CONCEPT, HOWEVER , PRIOR TO BIDD ING ,EACH MANUFACTURER SHALL COMPARE THE CATALOG NUMBERS SHOWN WITH THE DESCR IPTION AND REQUIREMENTS ON THE DRAWINGS , AND SHALLNOTIFY THE ARCHITECT /ENGINEER OF ANY DISCREPANCIES. SPECIF ICALLY INCLUDED IN TH IS EVALUATION SHALL BE THE VERIFYING OF PROPER MOUNTINGKITS OR ACCESSOR IES TO FACIL ITATE INSTALLATION AS SHOWN AT EACH LOCAT ION ON THE DRAW INGS. NO ALLOWANCE OR REDRESS WILL BE ALLOWEDFOR DISCREPANCIES THAT WERE NOT REPORTED TO THE ARCH ITECT/ENG INEER IN T IME FOR CORRECT ION OR CLARIF ICAT ION BEFORE THE BID. THEREPORTING OF ANY AMB IGU ITY IS THE RESPONS IB ILITY OF THE BIDDER . PROVIDE UNIT PRICES AND F IXTURE BRAND SELECTED FOR ADD /DELETE CHANGESFOR EACH FIXTURE TYPES SHOWN WITHIN 48 BUS INESS HOURS OF THE B ID DATE. FAILURE TO COMPLY W ITH TH IS REQUIREMENT MAY D ISQUAL IFY THEPRODUCTS AND EMPOWER THE ENGINEER TO DETERM INE FA IR VALUE FOR FIXTURE AND INSTALLAT ION CHANGES , W ITHOUT FURTHER INPUT FROM THECONTRACTOR OR INSTALLER . SUBM ITTAL PACKAGE SHALL INCLUDE LAMP MANUFACTURER AND CATALOG NUMBER ON EACH FIXTURE SHEET . ON ALLPENDANT MOUNTED FIXTURES, PROVIDE A SECOND SET OF PENDANTS, OF A D IFFERENT LENGTH , AS DIRECTED BY THE ARCHITECT /ENGINEER , PROVIDEDAND INSTALLED AT NO ADDITIONAL CHARGE. ALL FIXTURES SHALL BE APPROVED BY UL OR ANOTHER ACCEPTABLE TESTING LAB FOR THE PURPOSE INTENDED AND W ITH THE LAMP AND BALLAST PROPOSED . CONTRACTOR ALLOWANCE PRICES ARE ACCURATE WHEN TH IS JOB WAS SPEC IFIED,CONTRACTOR AND ELECTR ICAL D ISTRIBUTOR SHALL VER IFY TH IS ALLOWANCE AND REPORT ANY PROBLEMS TO THE ENGINEER BEFORE THE BID .ALLOWANCE PRICE MAY OR MAY NOT INCLUDE LAMP(S) OR FREIGHT AS NOTED , AND DO NOT INCLUDE ANY TAXES. UN IVERSAL VOLTAGE (120/277 )BALLASTS REQU IRED UNLESS NOTED OTHERW ISE . DIMENSION SEQUENCE = (LENGTH X W IDTH X DEPTH ) IN INCHES.SYMBOLNEW POWERTRANSFORMER82.6"x76.0"x71.9"NEW METER CABINET70"x41"x90" LIGHTING FIXTURE SCHEDULENOTE TO BIDDERS: COMPLY WITH THE SPECIFICATIONS. REFER TO SPECIFICATIONS FOR IMPORTANT TECHNICAL REQUIREMENTS FOR LIGHTING FIXTURES, BALLASTS, AND LAMPS. THE CATALOG NUMBERS LISTEDBELOW HAVE BEEN CAREFULLY PREPARED TO ASSIST BIDDERS IN SELECTING PRODUCTS TO ACHIEVE THE DESIGN CONCEPT, HOWEVER, PRIOR TO BIDDING,EACH MANUFACTURER SHALL COMPARE THE CATALOG NUMBERS SHOWN WITH THE DESCRIPTION AND REQUIREMENTS ON THE DRAWINGS, AND SHALLNOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES. SPECIFICALLY INCLUDED IN THIS EVALUATION SHALL BE THE VERIFYING OF PROPER MOUNTINGKITS OR ACCESSORIES TO FACILITATE INSTALLATION AS SHOWN AT EACH LOCATION ON THE DRAWINGS. NO ALLOWANCE OR REDRESS WILL BE ALLOWEDFOR DISCREPANCIES THAT WERE NOT REPORTED TO THE ARCHITECT/ENGINEER IN TIME FOR CORRECTION OR CLARIFICATION BEFORE THE BID. THEREPORTING OF ANY AMBIGUITY IS THE RESPONSIBILITY OF THE BIDDER. PROVIDE UNIT PRICES AND FIXTURE BRAND SELECTED FOR ADD/DELETE CHANGESFOR EACH FIXTURE TYPES SHOWN WITHIN 48 BUSINESS HOURS OF THE BID DATE. FAILURE TO COMPLY WITH THIS REQUIREMENT MAY DISQUALIFY THEPRODUCTS AND EMPOWER THE ENGINEER TO DETERMINE FAIR VALUE FOR FIXTURE AND INSTALLATION CHANGES, WITHOUT FURTHER INPUT FROM THECONTRACTOR OR INSTALLER. SUBMITTAL PACKAGE SHALL INCLUDE LAMP MANUFACTURER AND CATALOG NUMBER ON EACH FIXTURE SHEET. ON ALLPENDANT MOUNTED FIXTURES, PROVIDE A SECOND SET OF PENDANTS, OF A DIFFERENT LENGTH, AS DIRECTED BY THE ARCHITECT/ENGINEER, PROVIDEDAND INSTALLED AT NO ADDITIONAL CHARGE. ALL FIXTURES SHALL BE APPROVED BY UL OR ANOTHER ACCEPTABLE TESTING LAB FOR THE PURPOSEINTENDED AND WITH THE LAMP AND BALLAST PROPOSED. CONTRACTOR ALLOWANCE PRICES ARE ACCURATE WHEN THIS JOB WAS SPECIFIED,CONTRACTOR AND ELECTRICAL DISTRIBUTOR SHALL VERIFY THIS ALLOWANCE AND REPORT ANY PROBLEMS TO THE ENGINEER BEFORE THE BID.ALLOWANCE PRICE MAY OR MAY NOT INCLUDE LAMP(S) OR FREIGHT AS NOTED, AND DO NOT INCLUDE ANY TAXES. UNIVERSAL VOLTAGE (120/277)BALLASTS REQUIRED UNLESS NOTED OTHERWISE. DIMENSION SEQUENCE = (LENGTH X WIDTH X DEPTH) IN INCHES.SYMBOLMARKDLDL-1OCOC-1ZLZL-1ZL-1DFIXTURE CHARACTERISTICSBODY / AIR / MOUNTING / DOORLENS/LOUVER/REFLECTOR/OTHERRECESSED CANOPY LIGHT6" L SERIES LED RECESSED MODULE16" WIDE TRAPEZOIDEXTERIOR TRAPEZOIDLIGHT POLES: TOTALLY ENCLOSED RAINTIGHT, DUST-TIGHT AND CORROSION RESISTANT; POLE AS SHOWN IN DETAIL WITH HANDHOLE, COVER, BOLT COVER, AND BASE; PAINTED (COLOR TO BE SELECTED BY ARCHITECT / ENGINEER WHICH MAY DIFFER FROM CATALOG NUMBER SHOWN). MTB= 120,208,240,277 VOLT MULTI-TAP BALLAST. ALL BALLASTS PS. ARM MOUNT. HORIZONTAL LAMP.SHOEBOX STYLE, CUTOFF LUMINAIRE SINGLE HEAD, TYPE III DISTRIBUTION LEDSHOEBOX STYLE, CUTOFF LUMINAIRE TWO SINGLE HEADS, TYPE III DISTRIBUTION LEDLAMPLEDLEDLEDLEDWATTS13W47W421W842WVOLTS277/120V277/120VMVOLTMVOLTMANUFACTURERLITHONIALITHONIAEATONLSISPAULDINGMCGRAW-EDISONMCGRAW-EDISONCATALOG NUMBER6BLMW LEDWST LED 2 10A700/50K SR2 MVOLT PE XXXXXIST-E01-LED-E1-BL2-SCBA-7050XGBWM3-WT-LED-28-450-CW-UE-CBA-PCXXXTRP-30L5K-053-3-U-SCBA-PCGLEON-AE-08-LED-E1-T3GLEON-AE-08-LED-E1-T3 (2)NOTESUNLESS A PROFESSIONAL SEAL WITH SIGNATURE ANDDATE IS AFFIXED, THIS DOCUMENT IS PRELIMINARY ANDIS NOT INTENDED FOR CONSTRUCTION, RECORDINGPURPOSES OR IMPLEMENTATION.SHEET TITLEDESIGNED BY:DRAWN BY:DATE:CAD DWG FILE NO:DESIGN SEQUENCE PROJECT NO:AGENCY PROJECT NO:DWG TYPE:ARCHITECTURAL PHASE:1516.01BLACKMOREMARKET PLACEPERMIT SET324 S. State St., Suite 400Salt Lake City, UT 84111800-678-7077801-328-5151fax: 801-328-5155www.spectrum-engineers.comC:\Users\bxc\Documents\20160183 - Elec Central_bxc.rvt10/10/2016 12:06:27 PM PJGBC10/10/16ELECTRICAL SITE PLANES101Mark:Date:DescriptionSCALE:NTSPARKING LOT LIGHT POLE BASEDETAIL2SCALE: 1" = 40'-0"1SITE PLANNORTH10/13/16