HomeMy WebLinkAboutA00-42 - ACCESSIBILITY DETAILSGRAB BAR NOT REQUIRED
WHEN REINFORCEMENT
IS INSTALLED
LAVATORY ARE PERMITTED
TO ENCROACH ON CLEARANCE
BATH TUB
GRAB BAR REINFORCEMENT
REQUIRED
NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH4' - 8"4' - 0"
1' - 5" MIN.1' - 6"
3' - 0"6"
3' - 8"2"
FRONT OF LAVATORY AND SINK
SHALL BE 34" MAX. ABOVE THE
FINISHED FLOOR SURFACE
MEASURED TO THE HIGHER OF
THE FIXTURE RIM OR THE
COUNTER SURFACE
LAVATORY, NO KNEE
SPACE REQUIRED
WATER CLOSET
30" X 48" REQUIRED CLEARANCE
FOR PARALLEL APPROACH
NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH2' - 6"2' - 0"2' - 0"
1' - 5" MIN.
HATCHED AREA REPRESENTSMIN. REINFORCED AREA
BACK WALL
CONTROL AND HEAD WALL
NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS, REFER TO
SECTION 609.8 FOR BLOCKING DESIGN REQUIREMENTS
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH
BASED ON GUIDELINES P.9510
FEDERAL REGISTER 3/6/91 PART
OF SAFE HARBOR USING 2003
ANSI A117.16"4' - 0"6"
8"
2' - 6"1' - 10"8"2' - 6"3' - 2" MIN.VERTICAL BLOCKING ONLY
REQUIRED AT CONTROL WALL
1' - 2"2' - 0" MIN.1' - 2"CL
CL
HATCHED AREA REPRESENTS
MIN. REINFORCED AREA
VERTICAL
BLOCKING REQD. AT
PUBLIC AREAS ONLY.
(RE:10:A00.33) NOT
REQD. IN TYPE A
AND B UNITS
NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS;
REFER TO SECTION 609.8 FOR BLOCKING DESIGN REQUIREMENTS
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH
MIN.
1' - 2"
MIN.
1' - 2"
2' - 0" MIN.2' - 0" MIN.8"2' - 6"8"2' - 6"8"2' - 6"5' - 0"5' - 0"
3' - 1"8"
GRAB BAR REINFORCEMENT
REQUIRED
GRAB BAR NOT REQUIRED
WHEN REINFORCEMENT
IS INSTALLED
A SWING UP GRAB BAR SHALL
BE INSTALLED PER ANSI
SECTION 604.5.3
NOTE: DETAIL APPLIES TO SWING UP GRAB BAR AS DEFINED IN ANSI SECTION 604.5.3
AT LOCATIONS WHERE WALL MOUNTED GRAB BARS ARE NOT FEASIBLE
NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH
1' - 3 3/4"1' - 3 3/4"
3' - 10"2' - 4"MIN.
1' - 6"1' - 6"
TOILET FLUSH CONTROLS BETWEEN
15" AND 36" A.F.F. AND OPERABLE
WITH 5 LBS OF PRESSURE OR LESS,
LOCATE FLUSH CONTROL ON THE
OPEN SIDE OF WATER CLOSET PER
ANSI 117.1 SECTION 309 AND 604.6
INTERIOR EXTERIOR
PATIO SWING DOOR
THRESHOLD
1 2
IMPERVIOUS BALCONY
MATERIAL IN LINE WITH
INTERIOR FINISH FLOOR
ELEVATION. SLOPED AT
1/8" / FT. MAX.
NOTE: DESIGN BASED UPON 2009 ANSI 117.1 REQUIREMENTS
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH1/2" MAX.PROVIDE BEVELED
TRANSITION STRIP WHERE
THRESHOLD EXCEED 1/4"
INTERIOR EXTERIOR
PATIO SWING DOOR
THRESHOLD
1 2
IMPERVIOUS BALCONY MATERIAL IN LINE
WITH INTERIOR FINISH FLOOR ELEVATION.
SLOPED AT 1/8" / FT. MAX.
NOTE: DESIGN BASED UPON 2009 ANSI 117.1 REQUIREMENTS
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH1/2" MAX.3" MAX.PROVIDE BEVELEDTRANSITION STRIP WHERE
THRESHOLD EXCEED 1/4"
FLUSH CONTROLS SHALL COMPLY WITH ANSI SEC. 309
MAXIMUM 17" RIM HEIGHT ABOVE FINISH FLOOR
30X48 CLEAR FLOOR SPACE CENTERED ON URINAL
URINAL SCREEN OR WALL
NOTE: DESIGN BASED UPON 2009 ANSI 117.1 REQUIREMENTS AND 2010 ADA STANDARDS FOR ACCESSIBILITY
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISHNOTE: IF MORE THAN ONE URINAL IS PROVIDED, A MINIMUM OF ONE URINAL MUST HAVE A 48" MIN.
CLEAR FORWARD APPROACH WIDTH.
4' - 0" MIN.2' - 6"13 1/2" MIN.2' - 8" MIN.4' - 0"2' - 6"
6" MAX.8" MIN.27" MIN.29" MIN.34" MAX.TO REFLECTIVE SURFACE40" MAX.LAVATORY
30" X 48" CLEAR FLOOR AREA
CENTERED ON LAVATORY
MIRROR
APRON IF NEEDED
PROVIDE PIPE WRAP
INSULATION IF APRON IS NOT
PROVIDED
NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS AND 2010 ADA STANDARDS FOR ACCESSIBILITY
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH INCLUDING FINISH FLOOR ELEVATION
NOTE: GUARDRAILS OR OTHER BARRIERS SHALL BE PROVIDED WHERE OBJECT PROTRUSION IS
BEYOND THE LIMITS ALLOWED BY ANSI SECTION 307.2 AND 307.3
NOTE: INFORMATION BASED UPON ANSI 117.1 2003 REQUIREMENTS
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH
SECTION 2'-3" MAX.3' - 0"X < 7' - 0" OR 84"GUARDRAILS OR OTHER BARRIERS MUST BE PROVIDED
WHERE VERTICAL CLEARANCES ARE LESS THAN 84" ABOVE
THE FLOOR. THE LEADING EDGE OF SUCH GUARDRAIL
SHALL BE 27" MAX A.F.F. PER ANSI SECTION 307.4
NOTE: INFORMATION BASED UPON 2010 ADA ACCESSIBILITY GUIDELINES
AND 2009 ANSI 117.1 REQUIREMENTS
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH6' - 8" MIN. HEADROOM 6' - 8" MAX.2' - 3" MIN.4" MAX.
OBJECTS WITH LEADING EDGES STARTING
MORE THAN 27" A.F.F. WITH A HEIGHT NOT
MORE THAN 80" MAX. ARE PERMITTED TO
PROTRUDE 4" HORIZONTALLY INTO A
CIRCULATION PATH PER ANSI 307.2,
PROTRUDING OBJECTS CANNOT REDUCE
THE CLEAR WIDTH REQUIRED FOR
ACCESSIBLE ROUTES.
NOTE: HANDRAILS ARE PERMITTED TO
PROTRUDE 4" MAX
NOTE: DOOR CLOSERS AND DOOR STOPS ARE
PERMITTED TO BE 78" MIN. A.F.F.
NOTE: GUARDRAILS AND OTHER BARRIERS
SHALL BE PROVIDED WHERE OBJECTSPROTRUSION IS BEYOND THE LIMITS ALLOWED
BY ANSI SECTION 307.2 AND 307.3 3'-9" MAX - CL OF HIGHEST DEVICE1'-4" MIN.CL OF LOWEST DEVICEALL ENVIRONMENTAL CONTROLS, ELECTRICAL OUTLETS, LIGHT SWITCHES
AND USER CONTROLS FOR SECURITY OR INTERCOM SYSTEMS ARE TO BE
POSITIONED IN ACCESSIBLE LOCATIONS
PROVIDE 30" X 48" CLEAR FLOOR SPACE PERPENDICULAR TO WALL FOR
FORWARD APPROACH
PROVIDED BOTTOM OF LOWEST OUTLET OF RECEPTACLE AT MIN. / MAX.
DIMENSIONS GIVEN
PLACE TOP OF HIGHEST OUTLET OF RECEPTACLE AT MAX. DIMENSIONS
GIVEN AT KITCHEN COUNTER OR OTHER OBSTRUCTIONS 20"-25" DEPTH.
ALL KITCHEN OUTLETS SHALL BE INSTALLED 45" MAX. A.F.F. MEASURED TO
THE CENTERLINE OF THE HIGHEST DEVICE OUTLET (NOT TO THE
CENTERLINE OF THE OUTLET BOX). KITCHEN OUTLETS SHALL BE
INSTALLED 36" MIN. FROM CORNER COUNTERTOP CONDITIONS.
NOTE: AT ANSI TYPE A UNITS REACH RANGES ALSO APPLY TO APPLIANCE CONTROLS,
OPERATING HARDWARE FOR OPERABLE WINDOWS AND PLUMBING FIXTURES
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH
NOTE: INFORMATION BASED UPON ANSI 117.1 2003 REQUIREMENTS
NOTE: AT ANSI TYPE A UNITS REACH RANGES ALSO APPLY TO APPLIANCE CONTROLS,
OPERATING HARDWARE FOR OPERABLE WINDOWS AND PLUMBING FIXTURES
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH
NOTE: INFORMATION BASED UPON ANSI 117.1 2003 REQUIREMENTS
ROOM
NAME
. .. ...
NOTE: TEXT TO BE READ PER APPLICABLE ROOM DESIGNATION
NOTE: BRAILLE TO BE READ PER APPLICABLE ROOM DESIGNATION
SIGN REPRESENTATIONAL ONLY
LOWEST TACTILE CHARACTER4'-0" MIN. TO BASELINE OFHIGHEST BASELINE CHARACTER60" MIN. TO BASELINE OFSIGN NOTES:
1. IDENTIFICATION SIGNS SHALL BE PROVIDED
AS REQUIRED BY 2012 ADA DESIGN GUIDLINES
CHAPTER 4.
2. SIGNS CONTAINING TACTILE CHARACTERS
SHALL BE LOCATED THAT A CLEAR FLOOR AREA
18" MIN. X 18" MIN. CENTERED ON THE TACTILE
CHARACHTERS, IS PROVIDED BEYOND THE ARC
OF ANY DOOR SWING BETWEEN THE CLOSED
POSITION AND 45 DEGREE OPEN POSITION.
3. TACTILE CHARACTER SHALL BE 5/8" MIN. AND
2" MAX.
4. TACTILE CHARACHTERS SHALL BE RAISED
1/32", BRAILLE DOTS SHALL BE RAISED 1/40".
CL CL
CLCL
CL
CL
CL
CL
CL
CL
1 1/2" DIA. GRAB BAR
TOILET TISSUE DISPENSER.
DISPENSER SHALL NOT BE
WITHIN 1 1/2" OF ANY GRAB
BAR OR OTHER OBSTRUCTION
1 1/2" DIA. GRAB BAR
TOILET FLUSH CONTROLS
BETWEEN 15" AND 36" A.F.F AND
OPERABLE WITH 5 LBS. OF
PRESSURE OR LESS. LOCATE
FLUSH CONTROLS ON THE OPEN
SIDE OF WATER CLOSETS PER
ANSI SEC. 604.10.6
NOTE: DESIGN BASED UPON ADA ACCESSIBILITY
GUIDELINES AND 2009 ANSI 117.1 REQUIREMENTS
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH
1'-0"
6"3' - 0"19" MAX.17" MIN.3' - 0"39" TO 41"
1' - 0"3' - 6"19" MAX.17" MIN.8"19" MIN.33" TO 36"1' - 6" MIN.39" TO 41"1' - 6"
HATCHED AREA REPRESENTS
MIN. REINFORCED AREA4"4"CL CL
CL
CL
1 1/2" DIA. GRAB BAR
NOTE: DESIGN BASED UPON 2009 ANSI REQUIREMENTS
AND ADA STANDARDS FOR ACCESSIBILITY
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH
1'-6"
2' - 0" MIN.
1' - 0" MIN.4' - 8" MIN.5' - 0" MIN.3' - 6" MIN.1' - 0" MAX.GRAB BAR NOT REQUIRED
WHEN REINFORCEMENT
IS INSTALLED
LAVATORY ARE PERMITTED
TO ENCROACH ON CLEARANCE
BATH TUB
GRAB BAR REINFORCEMENT
REQUIRED
NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH
1' - 5" MIN.1' - 6"5' - 6"4' - 0"
3' - 0"6"
3' - 8"2"
GRAB BAR REINFORCEMENT
REQUIRED
GRAB BAR NOT REQUIRED
WHEN REINFORCEMENT
IS INSTALLED
GRAB BAR NOT REQUIRED
WHEN REINFORCEMENT
IS INSTALLED
LAVATORY ARE PERMITTED
TO ENCROACH ON CLEARANCE
4'-0"5'-6"NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH
1'-6"1'-5" MIN.3' - 6"1' - 0"8"4' - 2"3' - 0"6"
3' - 8"2"
GRAB BAR REINFORCEMENT
REQUIRED
GRAB BAR NOT REQUIRED
WHEN REINFORCEMENT
IS INSTALLED
GRAB BAR NOT REQUIRED
WHEN REINFORCEMENT
IS INSTALLED
LAVATORY ARE PERMITTED
TO ENCROACH ON CLEARANCE
NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS
NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH
1'-6"1'-5" MIN.3' - 6"1' - 0"8"4' - 2"3' - 0"6"
3' - 8"2"4' - 8"4' - 0"
NOTE: DESIGN BASED UPON 2003 117.1 ANSI REQUIREMENTS
AND 2010 ADA STANDARDS FOR ACCESSIBILITY
32" MIN. CLEAR WIDTH OPENING
PROVIDE 9" MIN. TOE
CLEARANCE BENEATH
TOILET PARTITIONS, TYP.
1/2" = 1'-0"5 CODE TYPE B / OPTION A - TUB
1/2" = 1'-0"6 CODE TYPE B - LAVATORY1
1/2" = 1'-0"7 TUB / SHOWER BLOCKING - ALL UNITS
1/2" = 1'-0"8 WATER CLOSET BLOCKING
1/2" = 1'-0"9 CODE TYPE A/B - WATER CLOSET1
3" = 1'-0"10 CODE TYPE A - PATIO DOOR SWING
3" = 1'-0"11 CODE TYPE B - PATIO DOOR SWING1
1/2" = 1'-0"15 PUBLIC URINAL
1/2" = 1'-0"16 PUBLIC LAVATORY
1/2" = 1'-0"17 PUBLIC REDUCED VERTICAL CLEARANCE
1/2" = 1'-0"18 PUBLIC PROTRUDING OBJECTS
N.T.S.19 OUTLET / SWITCHES / CONTROLS1
N.T.S.20 ROOM SIGNAGE
PUBLIC / CODE TYPE A / CODE TYPE B:
PROJECT
COPYRIGHT BY JOHNSON
NATHAN STROHE (JNS). ALL
DRAWN AND WRITTEN
INFORMATION APPEARING
HEREIN SHALL NOT BE
MODIFIED, DUPLICATED,
DISCLOSED, USED FOR
ANOTHER PROJECT, OR
OTHERWISE USED WITHOUT
THE WRITTEN CONSENT AND
INDEMNIFICATION OF JNS
SHEET TITLE
ISSUES/REVISIONS
STAMP
SHEET NUMBER
PRINTED ON1600 Wynkoop St., Suite 100 | Denver, CO 80202303.892.7062WWW.JNS.DESIGN12/28/2016 8:53:13 AMP:\1611\05-Design Drawings\08-Local Workstation\Kevin\1611_Black Olive_KEVIN.rvtA00.42BLACK & OLIVE, LLCBLACK OLIVE #1611
ACCESSIBILITY
DETAILS 110 E. OLIVE STREET, BOZEMAN, MONTANA 59715 1/2" = 1'-0"14 PUBLIC WATER CLOSET
1/2" = 1'-0"13 PUBLIC WATER CLOSET
1/2" = 1'-0"3 CODE TYPE B - WATER CLOSET
1/2" = 1'-0"2 CODE TYPE B - WATER CLOSET
1/2" = 1'-0"1 CODE TYPE B - WATER CLOSET
1/2" = 1'-0"4 PUBLIC TOILET COMPARTMENT
# Date Description
09/12/2016 100% SCHEMATIC
DESIGN
10/04/2016 SITE PLAN
1 11/30/2016 SITE PLAN - REV 1
2 01/04/2017 REV 2