Loading...
HomeMy WebLinkAboutA00-41 - ACCESSIBILITY ANALYSIS AND DETAILSA."CODE TYPE A" AND "CODE TYPE B" DETAILS APPLY TO ALL RESIDENTIAL UNITS AND ARE BASED ON IBC, ANSI 117.1, AND FHA REQUIREMENTS. B. "PUBLIC" DETAILS APPLY TO PUBLICLY ACCESSIBLE SPACES INCLUDING LEASING, AMENITY, COURTYARD, AND RETAIL SPACES AND ARE BASED ON IBC AND 2010 ADA. Specification AIf Specification A is used it applies to all bathrooms, and all fixtures in those bathrooms must be usable. Specification B If Specification B is used, it applies to one bathroom, and only one of each type of fixture must be usable; additional bathrooms in the unit are exempt only from maneuvering and clear floor space requirements at fixtures. Usable bathroom specifications include: 1. an accessible route to and into the bathroom with a nominal 32-inch clear door opening (Requirements 3 and 4), 2. switches, outlets, and controls in accessible locations (Requirement 5), 3. reinforced walls to allow for the later installation of grab bars around the toilet, tub, and shower stall; under certain conditions provisions for reinforcing must be made in shower stalls to permit the installation of a wall-hung bench seat (Requirement 6), 4. maneuvering space within the bathroom to permit a person using a mobility aid to enter the room, close and reopen the door, and exit (Requirement 7), and5. maneuvering and clear floor space within the bathroom to permit a person using a mobility aid to approach and use fixtures; fixture dimensions and placement are specified only under certain conditions (Requirement 7). Bathroom Requirements for Covered Dwelling Units All bathrooms as defined in the Guidelines must: 1. be on an accessible route (Requirement 4), 2. have 32-inch nominal clear width doorways (Requirement 3), 3. have switches, outlets, and controls in accessible locations (Requirement 5), 4. have reinforcing around toilets, tubs, and showers (Requirement 6), and 5. meet Requirement 7, Specification A or B: Specification A If Specification A is used it applies to all bathrooms, and all fixtures in those bathrooms must be usable. Specification BIf Specification B is used, it applies to one bathroom, and only one of each type of fixture must be usable; additional bathrooms in the unit are exempt only from maneuvering and clear floor space requirements at fixtures. Powder Room Requirements for Covered Dwelling Units Powder rooms must: 1. be on an accessible route (Requirement 4), 2. have 32-inch nominal clear width doorways (Requirement 3), and 3. have switches, outlets, and controls in accessible locations (Requirement 5). Exception When the powder room is the only toilet facility on the entry level of a multi-story unit in a building with one or more elevators, it must, in addition to Requirements 3, 4, and 5, meet the reinforcing specifications of Requirement 6 and the maneuvering and clear floor specifications of Requirement 7. Maximum Allowable Height Difference Between Interior Floor Level and Exterior Floor Level level difference at primary entry door: 0'' pervious construction (e.g., wood decking with spaces) 1/2'' impervious construction (e.g., concrete, brick, or flagstone) level difference at secondary door: 1/2'' pervious construction 4'' impervious construction Walks on Accessible Routes Walks that are part of accessible routes become ramps when their slope exceeds 5% (1 in 20). Handrails are not required on walks with slopes between 0% and 5%, but they are required on those steeper than 5% and up to 8.33% (1 in 12). Slopes steeper than 8.33% are not usable by most people with disabilities and cannot be considered part of an accessible route.Handrail requirements for walks differ, depending upon which buildings the walks connect. This is addressed in the following sections. FAUCET CONTROLS SHALL COMPLY WITH ANSI SEC. 309.4, PROVIDE FORWARD APPROACH WITH REMOVABLE BASE CABINET PER ANSI SEC. 1003.12.4.1, PROVIDE KNEE SPACE COMPLIANT WITH SEC.306, PLUMBING PIPING AND DISPOSAL ARE NOT PERMITTED TO ENCROACH ON KNEE SPACE SINK 33 1/2" MAX. A.F.F. TO TOP OF SINK RIM OR COUNTERTOP AND ONE BOWL SHALL HAVE A MAX. DEPTH OF 6 1/2" FROM TOP OF COUNTERTOP REFRIGERATOR SIDE BY SIDE CONFIGURATION, SHALL COMPLY WITH ANSI SEC. 1003.12.6.6 WORK SURFACE 34" MAX. A.F.F. WITH REMOVABLE BASE CABINET, FINISH WALL, FLOOR AND END PANELS OF SIDE CABINETS RANGE WITH FRONT ACCESSIBLE CONTROLS, RANGE HOOD ABOVE SHALL HAVE CONTROLS FOR LIGHT AND EXHAUST FAN WITHIN ACCESSIBLE REACH RANGE NOTE: DESIGN BASED ON 2009 ANSI A117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH NOTE: ALL 30"X48" CLEARANCES SHALL BE CENTERED ON THE APPLIANCE FOR PARALLEL APPROACH, UNLESS NOTED OTHERWISE REFRIGERATOR RANGE WITH RANGE HOOD ABOVE 30"X48" 30"X48" 30"X48" 30"X48" 30"X48"40" MIN.54".30" MIN. 30" MIN. SHOWER SPRAY UNIT WITH 59" LONG MIN. HOSE THAT CAN BE USED AS A FIXED OR HAND-HELD SHOWER HEAD. THE HAND-HELD PORTION MUST BE MOUNTED NO HIGHER THAN 48" PER ANSI SEC. 607.6 CONTROL LOCATION, EXCLUDING DRAIN STOPPERS18" MIN.6" MAX.3" MIN.3'-0" MAX.CL 1' - 6"1' - 6" 3' - 0"NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH. NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS 3' - 0"2' - 6"6"4' - 0"6"4' - 0"GRAB BAR REINFORCEMENT REQUIRED. REFER TO TUB/SHOWER BLOCKING DETAIL GRAB BAR NOT REQUIRED WHEN REINFORCEMENT IS INSTALLED 30" X 48" CLEARANCE FOR PARALLEL APPROACH PER ANSI SEC. 1004.11.3.1.3.1 30 "X 48" 30" X 48" REFRIGERATOR DISH WASHER NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH NOTE: ALL 30 X 48 CLEARANCES SHALL BE CENTERED ON THE APPLIANCE OR PLUMBING FIXTURE FOR PARALLEL APPROACH 30 "X 48" 30 "X 48"4' - 6"40" MIN. CLR.40" MIN. CLR.GRAB BAR REINFORCEMENT REQUIRED GRAB BAR NOT REQUIRED WHEN REINFORCEMENT IS INSTALLED LAVATORY COMPLYING WITH ANSI SEC. 1003.11.5 ARE PERMITTED TO ENCROACH ON CLEARANCE GRAB BAR NOT REQUIRED WHEN REINFORCEMENT IS INSTALLED TOILET FLUSH CONTROLS BETWEEN 15" AND 36" A.F.F. AND OPERABLE WITH 5 LBS OF PRESSURE OR LESS. LOCATE FLUSH CONTROL ON THE OPEN SIDE OF WATER CLOSET PER ANSI 117.1 SEC 309 AND 604.6 4'-2"NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH5' - 6"5' - 0"8"4' - 2"3' - 6"1' - 0"3' - 8"2" 3' - 0"6" 1' - 6" MIN.1' - 6" FAUCET CONTROLS SHALLCOMPLY WITH ANSI SEC. 309.4 AT LEAST 1 SINK BOWL SHALL HAVE A MAX. DEPTH OF 6 1/2" FROM TOP OF COUNTERTOP TOP OF COUNTERTOP OR SINK SHALL BE 33 1/2" A.F.F. MAX. EXPOSED PLUMBING PIPES SHALL BE INSULATED AND COMPLY WITH ANSI SEC. 306.4 REMOVABLE SINK BASE CABINET - AFTER BASE IS REMOVED, REMAINING CABINET SHALL PROVIDE CLEAR KNEE SPACE PER ANSI SEC. 306.4 FINISH WALL, END PANELS OF CABINETS AND EXTEND FLOOR FINISH BENEATH REMOVABLE BASE CABINET NOTE: DESIGN BASED ON 2009 ANSI A117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH3' - 0"2' - 9 1/2" MAX.2' - 3" MIN.33" MIN.6 1/2"30" X 48" CLEARANCE FOR PARALLEL APPROACH GRAB BAR NOT REQUIRED WHEN REINFORCEMENT IS INSTALLED GRAB BAR REINFORCEMENT REQUIRED. REFER TO TUB/SHOWER BLOCKING DETAIL NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH. NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS 2' - 8"2' - 6"6"4' - 0"6"2' - 8"4' - 0"TOILET TISSUE DISPENSER SHALL NOT BE WITHIN 1 1/2" OF ANY GRAB BAR OR OTHER OBSTRUCTION TOILET, FLUSH CONTROLS BETWEEN 15" AND 36" A.F.F. AND OPERABLE WITH 5 LBS. OF PRESSURE OR LESS. LOCATE FLUSH CONTROLS ON THE OPEN SIDE OF WATER CLOSETS PER ANSI 117.1 SEC. 309 AND 604.6 NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH. NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS. 7"-9"19" MAX.15" MIN.48" MAX.15" MIN.REMOVABLE BASE CABINET - AFTER CABINET IS REMOVED, REMAINING BASE CABINET SHALL PROVIDE CLEAR KNEE SPACE PER ANSI SEC. 306.4 FINISH WALL, END PANELS OF SIDE CABINETS AND EXTEND FLOOR FINISH BENEATH REMOVABLE BASE CABINET TOP OF COUNTER SHALL BE 33 1/2" A.F.F. MAX. NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH. NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS.3' - 0"33 1/2" MAX.27" MIN.33" MIN. 30" X WIDTH OF TUB REQUIRED CLEARANCE FOR PARALLEL APPROACH GRAB BAR NOT REQUIRED WHEN REINFORCEMENT IS INSTALLED GRAB BAR REINFORCEMENT REQUIRED. REFER TO TUB/SHOWER BLOCKING DETAIL NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH 2' - 8"2' - 6"6"4' - 0"6"2' - 8"LENGTH OF TUB48" X 60" CLEARANCE FOR FORWARD APPROACH PER ANSI SEC. 1004.11.3.1.3.2 NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH. NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS 3' - 0"5' - 0"6"4' - 0"6"4' - 0"GRAB BAR REINFORCEMENT REQUIRED. REFER TO TUB/SHOWER BLOCKING DETAIL GRAB BAR NOT REQUIRED WHEN REINFORCEMENT IS INSTALLED FAUCET CONTROLS SHALL COMPLY WITH ANSI SEC. 309.4, PROVIDE FORWARD APPROACHWITH REMOVABLE BASE CABINET PER ANSI SEC. 1003.12.4.1, PROVIDE KNEE SPACE COMPLIANT WITH SEC. 306, PLUMBING PIPING AND DISPOSAL ARE NOT PERMITTED TO ENCROACH ON KNEE SPACE SINK 33 1/2" MAX. A.F.F. TO TOP OF SINK RIM OR COUNTERTOP AND ONE BOWL SHALL HAVE A MAX. DEPTH OF 6 1/2" FROM TOP OF COUNTERTOP REFRIGERATOR SIDE BY SIDE CONFIGURATION, SHALL COMPLY WITH ANSI SEC. 1003.12.6.6 WORK SURFACE 34" MAX. A.F.F. WITH REMOVABLE BASE CABINET, FINISH WALL, FLOOR AND END PANELS OF SIDE CABINETS RANGE WITH FRONT ACCESSIBLE CONTROLS, RANGE HOOD ABOVE SHALL HAVE CONTROLS FOR LIGHT AND EXHAUST FAN WITHIN ACCESSIBLE REACH RANGE NOTE: DESIGN BASED ON 2009 ANSI A117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH NOTE: ALL 30"X48" CLEARANCES SHALL BE CENTERED ON THE APPLIANCE FOR PARALLEL APPROACH, UNLESS NOTED OTHERWISE 30"X48" 30"X48" 30"X48" 30"X48" 30"X48" 30" MIN.60" MIN. CLR.74".30" MIN. 30"X48" REFRIGERATOR DISH WASHER NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH NOTE: ALL 30 X 48 CLEARANCES SHALL BE CENTERED ON THE APPLIANCE OR PLUMBING FIXTURE FOR PARALLEL APPROACH6' - 2"60" MIN. CLR.30"X48" 30"X48" 30"X48" GRAB BAR NOT REQUIRED WHEN REINFORCEMENT IS INSTALLED GRAB BAR REINFORCEMENT REQUIRED. REFER TO TUB/SHOWER BLOCKINGDETAIL NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH. NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS6"4' - 0"6"2' - 8"4' - 0"2' - 6"1' - 6"5' - 0" MIN.Accessibility Analysis Black & Olive is an apartment building with 5 stories above grade with a parking garage at the 1st floor. The building is equipped with one elevator providing accessible access to all floors. Of the 56 units, 16 are studio units, 24 are one bedroom units and 16 are two bedroom units. Level 1 of the buildng contains accessible parking, leasing office, fitness, mailroom, and 943 SF of Retail space. Floors two - five each contain 14 residential units each. All required parking will be contained on site in the parking garage and on street parking. Applicable Codes2012 International Building Code (Chapter 11) 2009 ICC/ANSI A117.1, as referenced by the 2009 IBC 1998 Fair Housing Act Design Manual 1986 ANSI A117.1, as referenced by the FHA Design Manual 2010 ADA Standards for Accessible Design Safe Harbor for Compliance The Fair Housing Act Design Manual (1998) Scoping 2012 IBC Section 1107.6.2.1.1 requires that 2% of the total unit count be Type A accessible dwelling units. The remaining units shall be Type B accessible units. 2% of 56 units = 1.12 units (2 units) Type A dwelling units 6 pts each 6 pts x 2 Type A units = 12 pts Type B dwelling units 4 pts each 4 pts x 54 Type B units =216 pts Total points provided 228 pts 2 Type A dwelling units will be provided per 2012 IBC Section 1107.6.2.1.1 Total 1 bedroom Type A units 1 (1 required) Total 2 bedroom Type A units 1 (1 required) Total Type A units 2 Refer to the Accessibility Plans for locations of Type A dwelling units. 2012 IBC Analysis Accessible Route Accessible routes within the site shall be provided from public transportation stops, accessible 1104 parking, accessible passenger loading, and public streets or sidewalks to the accessible building entrance served. At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements and accessible spaces that are on the same site. An accessible path of travel has been provided throughout the building and site. Refer to the accessibility plans for travel within the building and to Civil drawings for accessible paths of travel throughout the site. Employee Work Areas Common use circulation paths within employee work areas shall be accessible routes. A 36" 1104.3.1 wide accessible path of travel has been provided to all employee work areas.--- Multilevel Buildings At least one accessible route shall connect each accessible level. One accessible elevators have 1104.4 been provided within the building. Accessible Entrances At least 60% of all public entrances shall be accessible. 1105 Accessible Parking Two percent of each type of parking space shall be accessible. Per IBC Table 1106.1, 2 total accessible parking stalls shall be provided including 1 Van parking stall. There are (1) van spaces, (1) accessible space and (1) accessible car share space being provided for a total of (2) accessible spaces provided. Accessible parking is provided at the shortest accessible route to the accessible building entrances and Type A dwelling units. Refer to Accessibility drawings on A00.40 for quantityand location of accessible parking stalls at each level. Dwelling Units Dwelling units that are required to be accessible Type A or Type B units shall 1107.2 comply with the applicable portions of the ICC/ANSI 117.1. Refer to the scoping information stated earlier in this analysis for quantity and type of accessible units. Storage Facilities Self-service storage facilities shall provide accessible individual self-storage spaces in accordance 1108.3 with Table 1108.3. 41 storage lockers are provided. Per Table 1108.3, 5% of storage spaces are required to be accessible (1 lockers). 1 accessible storage lockers are provided. Public Toilet and Toilet and bathing facilities shall be accessible. At least one of each type of Bathing Facilities fixture, element, control, or dispenser in each accessible toilet room shall be 1109.2 accessible. Water Closet Where water closet compartments are provided, at least one wheelchair Compartment accessible compartment shall be provided. Accessible compartments shall comply 1109.2.2 with ICC/ANSI 117.1. Sinks Where sinks are provided, at least 5% shall comply with ICC/ANSI 117.1. 1109.3 Kitchens Where kitchens are provided in accessible spaces, they shall comply with ICC/ANSI 117.1. 1109.4 Drinking Fountains One drinking fountain shall be provided per exception at wheelchair elevation. 1109.5 Elevators Elevators shall comply with ICC/ANSI 117.1 per Section 3001.3. 1109.7 Lifts Platform (wheelchair) lifts are permitted to be a part of a required accessible route to spaces 1109.8 that are not open to the general public with an occupant load of not more than 5 [residential units]. Storage Where fixed or built-in storage elements are provided, at least one of each type 1109.9 shall comply with ICC/ANSI 117.1. Work Surface Heights Where counters or work surfaces are provided, at least 5% of the seating and 1109.11 standing spaces, but not less than one, shall be accessible. Controls Controls, mechanisms, and hardware intended for operation by the occupant 1109.13 shall be accessible. Exceptions: 1.Operable parts intended for use only by maintenance personnel. 2.Electrical or communication receptacles serving a dedicated use. 3.Floor electrical receptacles. 4.HVAC diffusers. Operable Windows Where operable windows are provided within accessible spaces, at least one 1009.13.1 operable window shall be accessible. Exception: Accessible windows are not required in kitchens or bathrooms. Recreational Fac.Recreational facilities shall be provided with accessible features per Section 1109.15 1109.14.1 through 1109.14.4. Signage Accessible signage shall be provided per Section 1110 and IIC/ANSI 117.1. 1110 Fire Extinguisher Where provided along accessible routes, surface mounted extinguishers / cabinets projecting more Cabinets\than 4" from wall must have bottom of cylinder / cabinet not exceeding maximum 27" AFF or cane detection device must be provided. If cabinets are partially recessed, cabinet must not project more than 4" from wall or cabinet base must not exceed max. 27" AFF or cane detection device must be provided. WATER CLOSET FRONT OF LAVATORY AND SINK SHALL BE 34" MAX. ABOVE THE FINISHED FLOOR SURFACE MEASURED TO THE HIGHER OF THE FIXTURE RIM OR THE COUNTER SURFACE, OPERABLE FAUCET SHALL COMPLY WITH SECTION 309 LAVATORY SHALL COMPLY WITH ANSI SEC. 606 AND 306. A REMOVABLE BASE CABINET IS PERMITTED PER ANSI 1003.11.5 EXCEPTION 30" X 48" REQUIRED CLEARANCE FOR PARALLEL AND FORWARD APPROACH WITH KNEE SPACE NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH. NOTE: DESIGN BASED UPON 1998 ANSI REQUIREMENTS. ACCESSIBLE LAVATORIES AND SINKS SHALL COMPLY WITH SECTION 608.4' - 0"2' - 6"1' - 3"1' - 3" 2' - 0"2' - 0" 1'-6" MIN. MIRROR SHALL BE INSTALLED AT 40" MAX. ABOVE THE FLOOR TO THE BOTTOM EDGE OF THE REFLECTING SURFACE PROJECT COPYRIGHT BY JOHNSON NATHAN STROHE (JNS). ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE MODIFIED, DUPLICATED, DISCLOSED, USED FOR ANOTHER PROJECT, OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT AND INDEMNIFICATION OF JNS SHEET TITLE ISSUES/REVISIONS STAMP SHEET NUMBER PRINTED ON1600 Wynkoop St., Suite 100 | Denver, CO 80202303.892.7062WWW.JNS.DESIGN12/28/2016 8:53:05 AMP:\1611\05-Design Drawings\08-Local Workstation\Kevin\1611_Black Olive_KEVIN.rvtA00.41BLACK & OLIVE, LLCBLACK OLIVE #1611 ACCESSIBILITY ANALYSIS AND DETAILS 110 E. OLIVE STREET, BOZEMAN, MONTANA 59715ACCESSIBILITY ANALYSIS GENERAL ACCESSIBILITY NOTES 1/2" = 1'-0"2 CODE TYPE A - GALLEY KITCHEN1 1/2" = 1'-0"6 CODE TYPE A - TUB/SHOWER1 1/2" = 1'-0"14 CODE TYPE B / OPTION A - TUB 1/2" = 1'-0"11 CODE TYPE B - GALLEY KITCHEN1 1/2" = 1'-0"7 CODE TYPE A - WATER CLOSET 1/2" = 1'-0"3 CODE TYPE A - KITCHEN SINK1 1/2" = 1'-0"12 CODE TYPE B / OPTION B - TUB 1/2" = 1'-0"8 CODE TYPE A -WATER CLOSET1 1/2" = 1'-0"4 CODE TYPE A - WORK SURFACE1 1/2" = 1'-0"5 CODE TYPE A - TUB 1/2" = 1'-0"13 CODE TYPE B / OPTION A - TUB 1/2" = 1'-0"1 CODE TYPE A - U SHAPED KITCHEN1 1/2" = 1'-0"10 CODE TYPE B - U SHAPED KITCHEN1 1/2" = 1'-0"15 CODE TYPE B / OPTION C - TUB 1/2" = 1'-0"9 CODE TYPE A - LAVATORY1 1/4" = 1'-0"16 IBC STRETCHER COMPLIANCE # Date Description 09/12/2016 100% SCHEMATIC DESIGN 10/04/2016 SITE PLAN 1 11/30/2016 SITE PLAN - REV 1 2 01/04/2017 REV 2