HomeMy WebLinkAboutA01-05 - LEVEL 5 PLANA03.021
A03.02
A03.01
A03.01
1
2
2
B
C
D
A
1 2 5 7
E
98643
UNIT B-1b
502
UNIT A-1b
504
UNIT A-1b
506 UNIT S-1b
512
UNIT A-1b
513
UNIT B-2b
514
UNIT B-2a
511
UNIT A-1a
509
UNIT S-1c
507
UNIT A-1c
505
UNIT B-1a
501
STAIR 1
005-01
STAIR 2
005-02
TELECOM
515
TRASH
516 TELECOM517STORAGE
518
ELEV
05
UNIT S-1a
508
UNIT S-1d
510
147' - 0"
147' - 0"
PROPERTY LINEPROPERTY LINETYP.23.12
TYP.14.11
6' - 0"14' - 0"12' - 1"17' - 8"7' - 2"11' - 7"12' - 6"9' - 0"2' - 6"12' - 6"18' - 1"9' - 6"11' - 7"12' - 6"11' - 6"25' - 0"
32' - 1"17' - 8"7' - 2"33' - 1"33' - 1"9' - 6"24' - 1"36' - 6"5' - 10"34' - 0"6' - 0"34' - 0"5' - 10"5' - 6"28' - 6"6' - 0"28' - 6"5' - 6"32' - 1"17' - 8"7' - 2"33' - 1"33' - 1"9' - 6"24' - 1"36' - 6"5' - 10"5' - 0"5' - 0"24' - 0"6' - 0"24' - 0"5' - 0"5' - 0"5' - 10"34' - 0"6' - 0"34' - 0"4' - 10"1' - 0"5' - 0"2' - 6"2' - 6"2' - 8"15' - 7"4' - 6"1' - 3"3' - 0"3' - 0"2' - 2"7' - 0 5/8"11' - 6 3/8"3' - 3"2' - 6"2' - 6"5' - 0"1' - 0"4' - 10"1' - 0"5' - 6"7' - 9"5' - 7"14' - 3"11"3' - 0"3' - 0"3' - 5"13' - 8 1/8"8' - 6"2' - 11"5' - 6"1' - 0"TYP.14.6
TYP.8.26
150 SF
BALCONY
501a
UNIT A-1a
503
100 SF
BALCONY
509a
163 SF
BALCONY
511a
164 SF
BALCONY
514a
105 SF
BALCONY
508a
100 SF
BALCONY
506a
100 SF
BALCONY
504a
150 SF
BALCONY
502a
6' - 0"4' - 1 1/2"5' - 6"4' - 4 1/2"5' - 8"6' - 5"2' - 6"8' - 7 1/2"6' - 6 5/8"1' - 4"5' - 10"6' - 0"5' - 7"7' - 7"4' - 11"5' - 11"3' - 1"10' - 1"4' - 11"4' - 3"7' - 8"6' - 2"9' - 6"6' - 0"5' - 7"7' - 7"4' - 11"5' - 8 1/2"5' - 9 1/2"7' - 10"5' - 6"7' - 0"4' - 8"
100 SF
BALCONY
513a100 SF
BALCONY
512a
100 SF
BALCONY
510a
100 SF
BALCONY
505a 105 SF
BALCONY
507a
100 SF
BALCONY
503a
CORRIDOR
500
6' - 0"14' - 0"12' - 1"12' - 5"5' - 3"6' - 4"10"11' - 7"11' - 6"10' - 0"8' - 0"17' - 4"7' - 9"9' - 6"1"11' - 6"12' - 6"11' - 6"25' - 0"
3' - 0"3' - 0"4' - 1 1/2"6' - 2"3' - 8 1/2"6' - 0 3/8"6' - 0 5/8"4' - 10"7' - 7"5' - 0 1/2"2 1/2"6' - 4"10"4' - 0"7' - 7"5' - 11"5' - 7"4' - 3"5' - 9"1' - 5"6' - 7"3' - 7"7' - 2"6' - 7"3' - 7"4' - 2"3' - 0"6' - 6"1"5' - 5 1/2"6' - 0 1/2"7' - 7"4' - 11"5' - 8"5' - 10"7' - 10"5' - 6"7' - 0"4' - 8"
GENERAL NOTES
A. ALL DIMENSIONS SHOWN ON FLOOR PLANS ARE TO FACE OF
STUD, FACE OF CONCRETE OR CENTERLINE OF STRUCTURE.
B. "ALIGN" AS USED IN THESE DOCUMENTS SHALL MEAN TO
ACCURATELY LOCATE FINISH FACES IN THE SAME PLANE. THE
CONNECTION OF ALIGNED PLANES SHALL BE WITHOUT VISIBLE
JOINTS OR SURFACE IRREGULARITIES UNLESS NOTED
OTHERWISE.
C. PROVIDE BLOCKING IN PARTITIONS AS REQUIRED FOR ALL
ITEMS ATTACHED TO WALLS INCLUDING ITEMS PROVIDED BY
OWNER.
D. ALL GYPSUM BOARD TO BE 5/8" TYPE "X". MOISTURE AND
MILDEW RESISTANT GYP AT ALL BATHROOM WET AREAS, RE:
PLANS.
E. ALL PENETRATIONS AND JOINT AT DEMISING WALLS, CORRIDOR
WALLS AND EXTERIOR WALLS SHALL BE ACOUSTICALLY SEALED.
F. DETAILS ARE USUALLY KEYED ONLY ONCE THROUGHOUT THE
SET (ON PLANS OR ELEVATIONS) WHERE THEY OCCUR FIRST AND
ARE TYPICAL FOR SIMILAR CONDITIONS UNLESS NOTED
OTHERWISE.
G. "TYPICAL" MEANS FOR ALL SIMILAR CONDITIONS UNLESS NOTED
OTHERWISE
H. VERIFY ALL CONDITIONS IN FIELD. NOTIFY ARCHITECT OF ANY
DISCREPANCIES PRIOR TO PROCEEDING WITH CONSTRUCTION
I. DRYWALL SUBCONTRACTOR SHALL BE REQUIRED TO REPAIR
AND REFINISH ALL DRYWALL WHICH MAY HAVE BEEN DAMAGED,
CUT AWAY, OR REMOVED BY OTHER TRADES INCLUDING
MECHANICAL, PLUMBING, ELECTRICAL AND FIRE PROTECTION.
J. ALL WORK SHALL BE CONSTRUCTED IN COMFORMANCE WITH
THE RECOMMENDATIONS OF THE GEOTECHNICAL REPORT.
K. MECHANICAL EQUIPMENT PLACED ON ROOFING SHALL BE
SUPPORTED ON 8 INCH CURBS OR LEGS, WHICH SHALL BE
FLASHED TO THE ROOFING AND MADE WATERTIGHT.
L. ALL PROJECTIONS THROUGH THE ROOF SURFACE SHALL BE
PROPERLY FLASHED TO PREVENT MOISTURE ENTRY.
M. CONTRACTOR SHALL COMPLY WITH THE NATIONAL ROOFING
CONTRACTORS ASSOCIATION MANUAL (NRCA), AND THE SHEET
METAL AND AIR CONDITIONING CONTRACTORS NATIONAL
ASSOCIATION (SMACNA).
PROJET MATRIX
1
1
PROJECT
COPYRIGHT BY JOHNSON
NATHAN STROHE (JNS). ALL
DRAWN AND WRITTEN
INFORMATION APPEARING
HEREIN SHALL NOT BE
MODIFIED, DUPLICATED,
DISCLOSED, USED FOR
ANOTHER PROJECT, OR
OTHERWISE USED WITHOUT
THE WRITTEN CONSENT AND
INDEMNIFICATION OF JNS
SHEET TITLE
ISSUES/REVISIONS
STAMP
SHEET NUMBER
PRINTED ON1600 Wynkoop St., Suite 100 | Denver, CO 80202303.892.7062WWW.JNS.DESIGN11/29/2016 1:57:28 PMP:\1611\05-Design Drawings\08-Local Workstation\Kevin\1611_Black Olive_KEVIN.rvtA01.05BLACK & OLIVE, LLCBLACK OLIVE #1611
LEVEL 5 PLAN 110 E. OLIVE STREET, BOZEMAN, MONTANA 59715 1/8" = 1'-0"1 LEVEL 5 PLAN
KEYNOTES
8.26 METAL ROOF ALTERNATING TREAD DEVICE
14.6 HYDRAULIC ELEVATOR; MACHINE ROOM-LESS, STRETCHER
CAPABLE
14.11 TRASH CHUTE - 36"
23.12 MECH CHASE
NORTH
# Date Description
09/12/2016 100% SCHEMATIC
DESIGN
09/22/2016 100% SCHEMATIC
DESIGN (ARCH
UPDATE)
10/04/2016 SITE PLAN
1 11/30/2016 SITE PLAN - REV 1