Loading...
HomeMy WebLinkAboutL03.01 - LANDSCAPE AND IRRIGATION DETAILS2L03.013/4"=1'Shrub Planting DetailPRUNE SHRUB TO REMOVEDEAD OR DAMAGED LEAVESAND BRANCHESELEVATION OF SHRUBCROWN TO BE 3" ABOVEFINISHED GRADE ELEVATIONCIRCULAR SWALE TO RING SHRUB,2' DIAMETER WITH 3" HIGHMOUNDED RING OF SOILALL CONTAINMENT MATERIALSAROUND ROOTS TO BE REMOVEDPRIOR TO INSTALLATION13 NATIVE SOIL WITH 13 SANDY LOAMAND 13 DEBRIS FREE TOPSOIL.EXCAVATE HOLE AS SHOWN,3X DIAMETER OF ROOT BALL1L03.013/8"=1'Ball and Burlap Deciduous Tree Planting DetailPRUNE TREE TO REMOVEDEAD OR DAMAGED LIMBS ANDBRANCHESTREE STAKES AND TIESAS SHOWN. STAKES SHALLBE DRIVEN INTO EXISTING,UNDISTURBED SOIL ANDSHALL NOT PENETRATE THEROOT BALL. STAKES TO BEREMOVED AFTER TWO YEARS.FINISHED ELEVATION OF TREECROWN TO BE MIN 3" ANDMAX 6" ABOVE FINISHED GRADECIRCULAR SWALE TO RING TREE,4' DIAMETER WITH 3" HIGHMOUNDED RING OF SOILBURLAP TO BE REMOVEDFROM TOP 13 OF ROOT BALL.REMOVE WIRE CAGE FOLLOWINGPLANTING.13 NATIVE SOIL WITH 13 SANDY LOAMAND 13 DEBRIS FREE TOPSOIL.EXCAVATE HOLE AS SHOWN,3X DIAMETER OF ROOT BALL3L03.011/2"=1'Perennial Planting DetailX XXYBED EDGING ANDMULCH AS SPECIFIEDTILL NATIVE SOIL TO 12" DEPTH, ADDING ORGANIC SOILAMDENDMENT SO AS TO REACH MIN. 15% ORGANIC CONTENT IN SOIL.X = PLANT SPACING. REFER TO PLANT LEGEND FORSPACINGY = SPACING BETWEEN ROWS. 86% OF XO = PLANT LOCATIONTRIANGULAR SPACING4L03.011/2"=1'Ornamental Grass Planting DetailTRIANGULAR SPACING= PLANT LOCATIONX XXYY = SPACING BETWEEN ROWS, 86% OF X.X = PLANT SPACING. REFER TO PLANT LEGEND FOR SPACING REQUIREMENTS.TILL NATIVE SOIL TO 12" DEPTH. ADD ORGANICMATERIAL AS NECESSARY TO ACHIEVE 15% ORGANICCONTENT IN SOIL.BED EDGING AND MULCHAS SPECIFIED6L03.013/4"=1'Sod Planting at Pavement EdgePAVEMENT EDGE - SEE PLANSAND PAVING DETAILS FORADDITIONAL INFORMATION.SEE ALSO EDGING DETAILS ASAPPLICABLE.34" MINUS WASHED AGGREGATEBASE MATERIAL UNLESSOTHERWISE NOTED. SEEPAVING DETAILS FOR BASEMATERIAL DEPTHPREPARED SUBGRADE. REMOVEALL STONES OR OTHER DEBRISGREATER THAN 1" DIA. AND TILLEXISTING SOIL MIN. 4" BEFOREADDING TOPSOIL ORAMENDMENTS.1"REVEAL - SEE NOTE 2NOTE:1.SLOPE PLANTED AREAS AWAY FROM PAVED AREAS2.FINISH GRADES AT PAVEMENT EDGES MUST BE AT A LEVEL SUCH THATTHE ESTABLISHED TURF SURFACE WILL BE ONE (1) INCH BELOW TOP OFPAVEMENT FOR A MINIMUM DISTANCE OF SIX (6) FEET FROM THE EDGE.3.CONTRACTOR SHALL PROVIDE A 3" MINIMUM COMPACTED, DEPTH OFTOPSOIL ON ALL LAWN AREAS. TOPSOIL SHALL BE DRUM ROLLED ORTRACK-PACKED AND GRADED SMOOTHLY AND EVENLY.3" MIN. TOPSOIL. SEE NOTE 3SLOPESOD PER PLAN7L03.011"=1'Boulder DetailBOULDER PER PLAN.POSITION BOULDERWITH SMOOTHESTSIDE UP AND LEVELFOR USE AS A BENCHFINISHED GRADECOMPACT AGGREGATEBASE, 3" DEPTHNATIVE SOILMULCH PER PLAN1/2 TO 1/3 OF BOULDERTO BE BURIED BELOWFINISHED GRADE.5L03.011"=1'Edging Detail14" NATURAL STEEL EDGINGMULCH MATERIAL PER PLANMIN 3" DEEP.FINAL ELEVATION MIN 1" BELOWTOP OF STEEL EDGING1" FACE REVEAL#4 REBAR, 24" OC, MIN. 18" DEPTH SPOT WELD ON SITETO STEEL EDGINGWEED FABRIC PER PLAN4" STAPLES, 18" OCINTERIOR OREXTERIOR WALL15 1/2"CONTROLLER MODEL PER PLANMINIMUM CLEARANCEFOR DOOR OPENINGCONTROL WIRE CONDUIT,UP TO 2 1/2" SIZE.3/4" POWER SUPPLY CONDUITJ-BOX INSIDE CONTROLLERCONNECT PER LOCAL CODEADDITIONAL CONTROL WIRECONDUIT, UP TO 2" SIZE.SUPPLEMENTAL GROUND WIREINSTALL PER ASIC GUIDELINES8L03.01NTSIrrigation Controller Detail9L03.01NTSBackflow Preventer(1)FINISHED GRADENOTES1.1 12" BACKFLOW ASSEMBLY, PER LOCAL CODES AND ORDINANCES2.PRESSURE VACUUM BREAKERS MUST BE INSTALLED AT LEAST 12" ABOVEDOWNSTREAM PIPING3.ALL NIPPLES AND VALVES TO BE COPPER OR BRASSMANUAL BRASS SHUTOFFBALL VALVEMANUAL BRASS SHUTOFFBALL VALVEWINTERIZATION ASSEMBLY TO BEINSTALLED AS CLOSE TO BACKFLOW PREVENTER AS POSSIBLE.1"x4" CEDAR PANEL BACKFLOWENCLOSURENOTE:FOR MOST ACCURATE TEMPERATURESENSING, ROTATE THE MWS SO THAT THETHERMOSTAT PORTION POINTS SOUTH.THE MWS IS DESIGNED TO MOUNT ON A POSTOF 2" PIPE, ANY COMBINATION OF PIPE ANDFITTINGS MAY BE USED.2" PIPEMOUNT TO POST OR WALLWITH CONDUIT CLAMPSMODEL MWS-FR OR SIMILAROPTIMUM MOUNTINGHEIGHT 6' ABOVE GRADERUN LEAD WIRESTO CONTROLLER10L03.01NTSMini Weather Station - Hunter or Equivalent11L03.01NTSQuick CouplerNOTE:FINISH GRADES AT VALVE BOXES MUST BE AT A LEVEL SUCH THAT THEESTABLISHED TURF OR MULCH SURFACE WILL FLUSH WITH THE TOPOF THE BOX.QUICK COUPLING VALVE:RAINBIRD HQ44-RC OR EQUIVALENT34" ROUND VALVE BOX WITHLOCKING LID3 INCH MINIMUM DEPTH OF34" WASHED GRAVELBRICK (1 OF 2)PVC SCH. 80 NIPPLEPVC 1X1 TXT COUPLING LASCOG132212 SWING JOINTPVC OR POLY MAINLINE PIPEPER PLAN36" #4 REBAR WITH STAINLESSSTEEL GEAR CLAMPSFINISH GRADE.18"12"18"12"18"18"12L03.01NTSTrenching DetailsFINISH GRADELATERALLATERALMAIN LINEBEDDINGLOW VOLTAGE WIRELOW VOLTAGE WIRESECTIONSPLANSSNAKE ALLLATERAL PIPEIN TRENCHTAPE AND BUNDLE ALL WIRING AT 10'INTERVALS. USE 6" WIDE MARKING TAPE 6"ABOVE ALL DIRECT BURIAL WIRING. ALLSPLICES SHALL BE MADE IN VALVE BOXESAND LOCATED ON AS-BUILT PLANS.ALL 120V. WIRING SHALL BE IN CONDUIT WITHMARKER TAPE AS ABOVE. ALL WIRING UNDERPAVEMENT AND THROUGH SLEEVES SHALL BEIN CONDUIT.TIE A LOOSE 20" LOOP IN WIRING AT ALLCHANGES IN DIRECTION GREATER THAN 30DEGREES. UNTIE ALL LOOPS AFTER MAKINGCONNECTIONSFINISH GRADEMARKING TAPETIESLOOPDIRECT BURYSECTIONCONDUITSECTIONDIRECT BURY PLANCONDUIT PLANFINISH GRADESCH. 40 PVC SLEEVE - 4" MIN. OR 2X THE O.D.OF THE IRRIGATION PIPINGWRAP 12 GAUGE WIRE AROUND EACH ENDOF THE SLEEVE AND EXTEND TO THESURFACEWASHED AND GRADED MORTARSAND BACKFILL IN ROCKY SOIL.PAVEMENT EDGE13L03.01NTSIrrigation SleeveNOTE:1.CAP SLEEVES UNTIL USE.2.4" MIN. HORIZONTAL SEPARATION REQUIRED BETWEEN SLEEVESIN THE SAME TRENCH.3.IRRIGATION PIPE AND CONTROL WIRES SHALL BE SLEEVEDSEPARATELY.4.SOIL AROUND SLEEVE BACKFILLED AND COMPACTED TO THESAME DENSITY AS THE SURROUNDING SOIL.DEPTH PER TRENCHING DETAILEQ.EQ.14L03.01NTSValve Box LayoutIRRIGATION CONTROLVALVE BOXPROVIDE EQUAL SPACINGBETWEEN BOXESEDGE OF PAVEMENTALIGN BOXES PARALLEL TO THEEDGE OF PAVEMENTPLACE BOXES A MINIMUM OFONE (1) FOOT FROM EDGE OFPAVEMENTNOTE:GROUP SIMILAR BOX TYPES AND SIZES TOGETHER, I.E. PLACERECTANGULAR OR ROUND BOXES TOGETHER.1' MIN.NIBCO T-113 BRONZE GATEVALVE OR EQUIVALENTSCH 40 MALE ADAPTORFINISH GRADE10" VALVE BOX W/LOCKING LIDSCH 40 PVC MAIN LINE15L03.01NTSIsolation ValveNOTE:FINISH GRADES AT VALVE BOXES MUST BE AT A LEVEL SUCHTHAT THE ESTABLISHED TURF OR MULCH SURFACE WILLFLUSH WITH THE TOP OF THE BOX.T CHRISTY ID. TAGREMOTE CONTROL VALVESCH 80 PVC SOLVENT WELDED UNIONSSDR 21 PVC LATERAL PIPE16L03.01NTSIrrigation Control Valve - TURFVALVE BOX WITH LOCKING LIDFINISH GRADE - SEE NOTEWATERPROOF CONNECTIONS (2)18-24" COILED WIRESCH. 80 TOE NIPPLESCH. 40 FITTINGSBRICK SUPPORTS (4)34" MINUS WASHED GRAVELNOTE:FINISH GRADES AT VALVE BOXES MUST BE AT A LEVEL SUCH THAT THEESTABLISHED TURF OR MULCH SURFACE WILL FLUSH WITH THE TOPOF THE BOX.19L03.01NTSDrip for Trees and Large ShrubsGALVANIZED TIEDOWN STAKE:PRESSURECOMPENSATINGEMITTER MODULE14" VINYLDISTRIBUTION TUBINGDIFFUSER BUG CAPTREEXERI-TUBE 700COMPRESSIONADAPTERPVC FITTING AND RISERPVC LATERAL PIPECOMPRESSION FLUSHTREE PLANDIFFUSER BUG CAP:14" TUBING STAKE:MULCH AS SPECIFIEDWEED CONTROL FABRIC14" VINYL DISTRIBUTIONTUBINGXERI-TUBE 700SINGLE-OUTLET EMITTERTREE SECTIONNOTE:1.DIRECT (2) EMITTERS PER SHRUB AND (3) PERTREE2.EMITTERS SHOULD BE PLACED INSIDE TREEWELL, HALFWAY BETWEEN THE BASE OF THETREE AND EDGE OF ITS CANOPY.3.RUN XERI-TUBE 700 DISTRIBUTION TUBINGNO MORE THAN 250' LENGTH4.RUN 14" VINYL DISTRIBUTION TUBING NOMORE THAN 5' LENGTH20L03.01NTSEmitter on Stake14" TUBING DRIP EMITTERTUBING STAKEAMENDED SOIL 17MM BLANK PLD TUBING14" BARBED CONNECTORSUPER JUMBO VALVE BOXFINISH GRADE -SEE NOTE18-24" COILED WIREWATERPROOF CONNECTORS (2)BRICK SUPPORTS (7)SCH 80 T.O.E. NIPPLEMAIN LINE PIPE & FITTINGS3/4" MINUS WASHED GRAVELDRIP ZONE KITLATERAL PIPE AND FITTINGSPVC SLIP UNIONS (2)17L03.01NTSIrrigation Control Valve - DRIPNOTE:FINISH GRADES AT VALVE BOXES MUST BE AT A LEVEL SUCH THAT THEESTABLISHED TURF OR MULCH SURFACE WILL FLUSH WITH THE TOP OF THEBOX.LATERAL PIPEFINISH GRADELATERAL TEE OR ELLSWING JOINT:HUNTER SJ-506 OR EQUIVALENT18L03.01NTSHunter Pro Spray or EquivalentNOTE:FINISH GRADES AT VALVE BOXES MUST BE AT A LEVELSUCH THAT THE ESTABLISHED TURF OR MULCH SURFACEWILL FLUSH WITH THE TOP OF THE BOX.MODEL PROS-04-PRS40-CV OR EQUIVALENTWITH MP ROTATOR NOZZLESHEET TITLEISSUES/REVISIONSSTAMPSHEET NUMBERZ:\Clients\Black and Olive\Autocad\01_Sheets BLACK & OLIVE, LLC BLACK OLIVE 110 EAST OLIVE STREET, BOZEMAN, MONTANA 59715NOT FORCONSTRUCTION#DateDescription10/04/2016SITE PLAN#DateDescription111/30/2016SITE PLAN REV 1L03.01LANDSCAPEAND IRRIGATIONDETAILS1