Loading...
HomeMy WebLinkAboutA00-42 - ACCESSIBILITY DETAILSGRAB BAR NOT REQUIREDWHEN REINFORCEMENT IS INSTALLED LAVATORY ARE PERMITTED TO ENCROACH ON CLEARANCE BATH TUB GRAB BAR REINFORCEMENT REQUIRED NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH4' - 8"4' - 0" 1' - 5" MIN.1' - 6" 3' - 0"6" 3' - 8"2" FRONT OF LAVATORY AND SINK SHALL BE 34" MAX. ABOVE THE FINISHED FLOOR SURFACE MEASURED TO THE HIGHER OF THE FIXTURE RIM OR THE COUNTER SURFACE LAVATORY, NO KNEE SPACE REQUIRED WATER CLOSET 30" X 48" REQUIRED CLEARANCE FOR PARALLEL APPROACH NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH2' - 6"2' - 0"2' - 0" 1' - 5" MIN. HATCHED AREA REPRESENTSMIN. REINFORCED AREA BACK WALL CONTROL AND HEAD WALL NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS, REFER TO SECTION 609.8 FOR BLOCKING DESIGN REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH BASED ON GUIDELINES P.9510 FEDERAL REGISTER 3/6/91 PART OF SAFE HARBOR USING 2003 ANSI A117.16"4' - 0"6" 8" 2' - 6"1' - 10"8"2' - 6"3' - 2" MIN.VERTICAL BLOCKING ONLY REQUIRED AT CONTROL WALL 1' - 2"2' - 0" MIN.1' - 2"CL CL HATCHED AREA REPRESENTS MIN. REINFORCED AREA VERTICAL BLOCKING REQD. AT PUBLIC AREAS ONLY. (RE:10:A00.33) NOT REQD. IN TYPE A AND B UNITS NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS; REFER TO SECTION 609.8 FOR BLOCKING DESIGN REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH MIN. 1' - 2" MIN. 1' - 2" 2' - 0" MIN.2' - 0" MIN.8"2' - 6"8"2' - 6"8"2' - 6"5' - 0"5' - 0" 3' - 1"8" GRAB BAR REINFORCEMENT REQUIRED GRAB BAR NOT REQUIRED WHEN REINFORCEMENT IS INSTALLED A SWING UP GRAB BAR SHALL BE INSTALLED PER ANSI SECTION 604.5.3 NOTE: DETAIL APPLIES TO SWING UP GRAB BAR AS DEFINED IN ANSI SECTION 604.5.3 AT LOCATIONS WHERE WALL MOUNTED GRAB BARS ARE NOT FEASIBLE NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH 1' - 3 3/4"1' - 3 3/4" 3' - 10"2' - 4"MIN. 1' - 6"1' - 6" TOILET FLUSH CONTROLS BETWEEN 15" AND 36" A.F.F. AND OPERABLE WITH 5 LBS OF PRESSURE OR LESS, LOCATE FLUSH CONTROL ON THE OPEN SIDE OF WATER CLOSET PER ANSI 117.1 SECTION 309 AND 604.6 INTERIOR EXTERIOR PATIO SWING DOOR THRESHOLD 1 2 IMPERVIOUS BALCONY MATERIAL IN LINE WITH INTERIOR FINISH FLOOR ELEVATION. SLOPED AT 1/8" / FT. MAX. NOTE: DESIGN BASED UPON 2009 ANSI 117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH1/2" MAX.PROVIDE BEVELED TRANSITION STRIP WHERE THRESHOLD EXCEED 1/4" INTERIOR EXTERIOR PATIO SWING DOOR THRESHOLD 1 2 IMPERVIOUS BALCONY MATERIAL IN LINE WITH INTERIOR FINISH FLOOR ELEVATION. SLOPED AT 1/8" / FT. MAX. NOTE: DESIGN BASED UPON 2009 ANSI 117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH1/2" MAX.3" MAX.PROVIDE BEVELEDTRANSITION STRIP WHERE THRESHOLD EXCEED 1/4" FLUSH CONTROLS SHALL COMPLY WITH ANSI SEC. 309 MAXIMUM 17" RIM HEIGHT ABOVE FINISH FLOOR 30X48 CLEAR FLOOR SPACE CENTERED ON URINAL URINAL SCREEN OR WALL NOTE: DESIGN BASED UPON 2009 ANSI 117.1 REQUIREMENTS AND 2010 ADA STANDARDS FOR ACCESSIBILITY NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH NOTE: IF MORE THAN ONE URINAL IS PROVIDED, A MINIMUM OF ONE URINAL MUST HAVE A 48" MIN. CLEAR FORWARD APPROACH WIDTH. 4' - 0" MIN.2' - 6"13 1/2" MIN.2' - 8" MIN.4' - 0"2' - 6" 6" MAX.8" MIN.27" MIN.29" MIN.34" MAX.TO REFLECTIVE SURFACE40" MAX.LAVATORY 30" X 48" CLEAR FLOOR AREA CENTERED ON LAVATORY MIRROR APRON IF NEEDED PROVIDE PIPE WRAP INSULATION IF APRON IS NOT PROVIDED NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS AND 2010 ADA STANDARDS FOR ACCESSIBILITY NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH INCLUDING FINISH FLOOR ELEVATION NOTE: GUARDRAILS OR OTHER BARRIERS SHALL BE PROVIDED WHERE OBJECT PROTRUSION IS BEYOND THE LIMITS ALLOWED BY ANSI SECTION 307.2 AND 307.3 NOTE: INFORMATION BASED UPON ANSI 117.1 2003 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH SECTION 2'-3" MAX.3' - 0"X < 7' - 0" OR 84"GUARDRAILS OR OTHER BARRIERS MUST BE PROVIDED WHERE VERTICAL CLEARANCES ARE LESS THAN 84" ABOVE THE FLOOR. THE LEADING EDGE OF SUCH GUARDRAIL SHALL BE 27" MAX A.F.F. PER ANSI SECTION 307.4 NOTE: INFORMATION BASED UPON 2010 ADA ACCESSIBILITY GUIDELINES AND 2009 ANSI 117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH6' - 8" MIN. HEADROOM 6' - 8" MAX.2' - 3" MIN.4" MAX. OBJECTS WITH LEADING EDGES STARTING MORE THAN 27" A.F.F. WITH A HEIGHT NOT MORE THAN 80" MAX. ARE PERMITTED TO PROTRUDE 4" HORIZONTALLY INTO A CIRCULATION PATH PER ANSI 307.2, PROTRUDING OBJECTS CANNOT REDUCE THE CLEAR WIDTH REQUIRED FOR ACCESSIBLE ROUTES. NOTE: HANDRAILS ARE PERMITTED TO PROTRUDE 4" MAX NOTE: DOOR CLOSERS AND DOOR STOPS ARE PERMITTED TO BE 78" MIN. A.F.F. NOTE: GUARDRAILS AND OTHER BARRIERS SHALL BE PROVIDED WHERE OBJECTS PROTRUSION IS BEYOND THE LIMITS ALLOWED BY ANSI SECTION 307.2 AND 307.3 3'-9" MAX - CL OF HIGHEST DEVICE1'-4" MIN.CL OF LOWEST DEVICEALL ENVIRONMENTAL CONTROLS, ELECTRICAL OUTLETS, LIGHT SWITCHES AND USER CONTROLS FOR SECURITY OR INTERCOM SYSTEMS ARE TO BE POSITIONED IN ACCESSIBLE LOCATIONS PROVIDE 30" X 48" CLEAR FLOOR SPACE PERPENDICULAR TO WALL FOR FORWARD APPROACH PROVIDED BOTTOM OF LOWEST OUTLET OF RECEPTACLE AT MIN. / MAX. DIMENSIONS GIVEN PLACE TOP OF HIGHEST OUTLET OF RECEPTACLE AT MAX. DIMENSIONS GIVEN AT KITCHEN COUNTER OR OTHER OBSTRUCTIONS 20"-25" DEPTH. ALL KITCHEN OUTLETS SHALL BE INSTALLED 45" MAX. A.F.F. MEASURED TO THE CENTERLINE OF THE HIGHEST DEVICE OUTLET (NOT TO THE CENTERLINE OF THE OUTLET BOX). KITCHEN OUTLETS SHALL BE INSTALLED 36" MIN. FROM CORNER COUNTERTOP CONDITIONS. NOTE: AT ANSI TYPE A UNITS REACH RANGES ALSO APPLY TO APPLIANCE CONTROLS, OPERATING HARDWARE FOR OPERABLE WINDOWS AND PLUMBING FIXTURES NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH NOTE: INFORMATION BASED UPON ANSI 117.1 2003 REQUIREMENTS NOTE: AT ANSI TYPE A UNITS REACH RANGES ALSO APPLY TO APPLIANCE CONTROLS,OPERATING HARDWARE FOR OPERABLE WINDOWS AND PLUMBING FIXTURES NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH NOTE: INFORMATION BASED UPON ANSI 117.1 2003 REQUIREMENTS ROOMNAME . .. ... NOTE: TEXT TO BE READ PER APPLICABLE ROOM DESIGNATION NOTE: BRAILLE TO BE READ PER APPLICABLE ROOM DESIGNATION SIGN REPRESENTATIONAL ONLY LOWEST TACTILE CHARACTER4'-0" MIN. TO BASELINE OFHIGHEST BASELINE CHARACTER60" MIN. TO BASELINE OFSIGN NOTES: 1. IDENTIFICATION SIGNS SHALL BE PROVIDED AS REQUIRED BY 2012 ADA DESIGN GUIDLINES CHAPTER 4. 2. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED THAT A CLEAR FLOOR AREA 18" MIN. X 18" MIN. CENTERED ON THE TACTILE CHARACHTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. 3. TACTILE CHARACTER SHALL BE 5/8" MIN. AND 2" MAX. 4. TACTILE CHARACHTERS SHALL BE RAISED 1/32", BRAILLE DOTS SHALL BE RAISED 1/40". CL CL CLCL CL CL CL CL CL CL 1 1/2" DIA. GRAB BAR TOILET TISSUE DISPENSER.DISPENSER SHALL NOT BE WITHIN 1 1/2" OF ANY GRAB BAR OR OTHER OBSTRUCTION 1 1/2" DIA. GRAB BAR TOILET FLUSH CONTROLS BETWEEN 15" AND 36" A.F.F AND OPERABLE WITH 5 LBS. OF PRESSURE OR LESS. LOCATE FLUSH CONTROLS ON THE OPEN SIDE OF WATER CLOSETS PER ANSI SEC. 604.10.6 NOTE: DESIGN BASED UPON ADA ACCESSIBILITY GUIDELINES AND 2009 ANSI 117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH 1'-0" 6"3' - 0"19" MAX.17" MIN.3' - 0"39" TO 41" 1' - 0"3' - 6"19" MAX.17" MIN.8"19" MIN.33" TO 36"1' - 6" MIN.39" TO 41"1' - 6" HATCHED AREA REPRESENTS MIN. REINFORCED AREA4"4"CL CL CL CL 1 1/2" DIA. GRAB BAR NOTE: DESIGN BASED UPON 2009 ANSI REQUIREMENTSAND ADA STANDARDS FOR ACCESSIBILITY NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH 1'-6" 2' - 0" MIN. 1' - 0" MIN.4' - 8" MIN.5' - 0" MIN.3' - 6" MIN.1' - 0" MAX.GRAB BAR NOT REQUIREDWHEN REINFORCEMENT IS INSTALLED LAVATORY ARE PERMITTEDTO ENCROACH ON CLEARANCE BATH TUB GRAB BAR REINFORCEMENT REQUIRED NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH 1' - 5" MIN.1' - 6"5' - 6"4' - 0" 3' - 0"6" 3' - 8"2" GRAB BAR REINFORCEMENT REQUIRED GRAB BAR NOT REQUIRED WHEN REINFORCEMENT IS INSTALLED GRAB BAR NOT REQUIRED WHEN REINFORCEMENT IS INSTALLED LAVATORY ARE PERMITTED TO ENCROACH ON CLEARANCE 4'-0"5'-6"NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH 1'-6"1'-5" MIN.3' - 6"1' - 0"8"4' - 2"3' - 0"6" 3' - 8"2" GRAB BAR REINFORCEMENT REQUIRED GRAB BAR NOT REQUIRED WHEN REINFORCEMENT IS INSTALLED GRAB BAR NOT REQUIRED WHEN REINFORCEMENT IS INSTALLED LAVATORY ARE PERMITTED TO ENCROACH ON CLEARANCE NOTE: DESIGN BASED UPON 2009 ANSI A117.1 REQUIREMENTS NOTE: ALL DIMENSIONS ARE TO FACE OF FINISH 1'-6"1'-5" MIN.3' - 6"1' - 0"8"4' - 2"3' - 0"6" 3' - 8"2"4' - 8"4' - 0" NOTE: DESIGN BASED UPON 2003 117.1 ANSI REQUIREMENTS AND 2010 ADA STANDARDS FOR ACCESSIBILITY 32" MIN. CLEAR WIDTH OPENING PROVIDE 9" MIN. TOE CLEARANCE BENEATH TOILET PARTITIONS, TYP. 1/2" = 1'-0"5 CODE TYPE B / OPTION A - TUB 1/2" = 1'-0"6 CODE TYPE B - LAVATORY1 1/2" = 1'-0"7 TUB / SHOWER BLOCKING - ALL UNITS 1/2" = 1'-0"8 WATER CLOSET BLOCKING 1/2" = 1'-0"9 CODE TYPE A/B - WATER CLOSET1 3" = 1'-0"10 CODE TYPE A - PATIO DOOR SWING 3" = 1'-0"11 CODE TYPE B - PATIO DOOR SWING1 1/2" = 1'-0"15 PUBLIC URINAL 1/2" = 1'-0"16 PUBLIC LAVATORY 1/2" = 1'-0"17 PUBLIC REDUCED VERTICAL CLEARANCE 1/2" = 1'-0"18 PUBLIC PROTRUDING OBJECTS N.T.S.19 OUTLET / SWITCHES / CONTROLS1 N.T.S.20 ROOM SIGNAGE PUBLIC / CODE TYPE A / CODE TYPE B: PROJECT COPYRIGHT BY JOHNSON NATHAN STROHE (JNS). ALL DRAWN AND WRITTEN INFORMATION APPEARING HEREIN SHALL NOT BE MODIFIED, DUPLICATED, DISCLOSED, USED FORANOTHER PROJECT, OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT AND INDEMNIFICATION OF JNS SHEET TITLE ISSUES/REVISIONS STAMP SHEET NUMBER PRINTED ON1600 Wynkoop St., Suite 100 | Denver, CO 80202303.892.7062WWW.JNS.DESIGN9/29/2016 1:49:37 PMP:\1611\05-Design Drawings\08-Local Workstation\Kevin\1611_Black Olive_KEVIN.rvtA00.42BLACK & OLIVE, LLCBLACK OLIVE #1611 ACCESSIBILITY DETAILS 202 SOUTH BLACK AVENUE, BOZEMAN, MONTANA 59715 1/2" = 1'-0"14 PUBLIC WATER CLOSET 1/2" = 1'-0"13 PUBLIC WATER CLOSET 1/2" = 1'-0"3 CODE TYPE B - WATER CLOSET 1/2" = 1'-0"2 CODE TYPE B - WATER CLOSET 1/2" = 1'-0"1 CODE TYPE B - WATER CLOSET 1/2" = 1'-0"4 PUBLIC TOILET COMPARTMENT # Date Description 09/12/2016 100% SCHEMATIC DESIGN 10/04/2016 SITE PLAN